PubMed Health⌕ Search

Biomedical subjects

Siegfried Jank

Publications and source records attributed to Siegfried Jank.

11 recordsLinked to original sources

A reason for the use of toluidine blue staining in the presurgical management of patients with oral squamous cell carcinomas.

Verification of oral cancer relies on histopathological diagnosis of suspect or malignant lesions. There is evidence for further pre-surgical screening procedures to localize tumor borders and define other malignant lesions. Important methods are: visual examination, including pan-endoscopy, fluorescence imaging, and brush biopsy, as well as radiologic techniques such as conventional radiography, computed tomography, magnetic resonance imaging, scintigraphy, and ultrasonography, which may reduce the mortality rate associated with oral cancer. In addition, toluidine blue staining is a simple, inexpensive, and excellent diagnostic tool. Herein we show that the clinical use of in vivo staining is effective to define the superficial tumor borders and to detect malignant or pre-malignant cells in the surrounding area of the tumor following detection of a malignancy of the oral cavity. In our reported case, the main tumor mass was surrounded by layers of an intact mucosa, yet in a distance of more than 1 cm a group of malignant or pre-malignant cells in the surrounding area required a resection of the tumor in a size that would have been unaddressed during visual examination alone followed by clinical routine program of presurgical examinations after the detection of a malignancy of the oral cavity.

Carcinoma, Squamous Cell↗

High EGFR expression predicts poor prognosis in patients with squamous cell carcinoma of the oral cavity and oropharynx: a TMA-based immunohistochemical analysis.

This retrospective study was designed to investigate the prognostic significance of EGFR overexpression in human oral squamous cell carcinoma on a long-term follow-up. EGFR expression was examined immunohistochemically on a tissue microarray (TMA) of paraffin embedded tissue specimens from 109 patients who underwent surgical treatment for squamous cell carcinoma of the oral cavity and oropharynx in the period between 1980 and 1997. High EGFR expression was found in 80 (73.42%) of the tumour samples. Kaplan-Meier curves showed that EGFR overexpression was significantly related to decreased overall survival (p=0.05). Multivariate analysis showed that EGFR overexpression is an independent prognostic marker in these patients (p=0.02, RR 3.6). These results confirm that EGFR overexpression is an independent prognostic marker in patients with squamous cell carcinoma of the oral cavity and oropharynx. The EGFR antigen represents an attractive target for targeted therapies with monoclonal antibodies or specific tyrosine-kinase inhibitors in these patients.

Adult↗

Intrarater reliability in the ultrasound diagnosis of medial and lateral orbital wall fractures with a curved array transducer.

PURPOSE: The aims of the study were to document the effectiveness of ultrasound (US) in diagnosing orbital wall fractures when compared with computed tomography (CT) and to measure the intraobserver reliability of US using a curved array transducer. MATERIALS AND METHODS: From December 2003 to March 2004, 13 patients with the clinical diagnosis of an orbital trauma were investigated prospectively by CT (reference) and 2 US investigators. Both orbits were investigated. Sensitivity, specificity, accuracy, and positive and negative predictive value were calculated. The statistical difference between the 2 US investigators was calculated by a chi-square test. The interrater reliability was calculated using the lambda coefficient. Values below 0.4 represent poor reliability, between 0.4 and 0.75 represent fair to good reliability, and a score > 0.75 is graded as excellent reliability. RESULTS: The comparison of the results of the 2 US investigators by the chi-square test showed P values of .385 for the medial orbital wall and .638 for the lateral orbital wall, which shows no significant difference. The lambda-value for the investigation of the medial orbital wall reached 0.429, 0.714, and 0.750. The lambda-value for the investigation of the lateral orbital wall yielded 0.647, 0.750, and 0.882. These values show a good and excellent inter-rater reliability. CONCLUSION: The US investigation does not yet reach the diagnostic quality of CT. US could be a helpful diagnostic imaging tool in cases with clear clinical symptoms. The results of the current study and the previously published results imply that US has the potential to reach the same diagnostic quality as CT in the future, but further studies must be performed to improve the diagnostic quality of the method.

Adolescent↗

Interrater reliability of sonographic examinations of orbital fractures.

OBJECTIVE: The purpose of this study is to determine whether there are statistically significant variations among different observers when examining fractures of the orbital walls. MATERIAL AND METHODS: From December 2003 to April 2004, 28 patients with clinically suspected orbital fractures were examined by ultrasound prospectively. The US images of the infra-orbital margins, the orbital floors, the medial and lateral orbital walls of each patient were reexamined by two independent investigators. RESULTS: Computed tomography revealed fractures of the orbital floor in 28 out of 31 patients (90.3%). The infra-orbital margins showed fractures of 14 of 31 patients (45.2%). The ultrasound examinations of the orbits by the three examiners presented satisfactory correlation regarding sensitivity and specificity. There were no significant differences between investigators. There was good agreement among the ultrasound examiners regarding the infra-orbital margins. This was not the case for the orbital floors. CONCLUSIONS: If there are clear cut clinical findings ultrasound examination could represent an alternative to computed tomography. If the clinical findings were indeterminate, computed tomography was essential as implicated by this study. Accordingly, further evaluation of ultrasound examinations of fractures of the orbital margins and floors are necessary.

Adolescent↗

Ultrasound versus computed tomography in the imaging of orbital floor fractures.

PURPOSE: The aim of the study was to investigate whether orbital ultrasonography (US) with a curved-array transducer could be an alternative imaging method to computed tomography (CT) to detect orbital wall fractures and fractures of the infraorbital rim. MATERIALS AND METHODS: Fifty-eight patients with the clinical ophthalmologic or radiologic diagnosis of an orbital trauma were investigated prospectively by US and CT. The reference method was the intraoperative findings. RESULTS: CT evaluation of the infraorbital rim yielded a sensitivity of 79%, a specificity of 90%, and an accuracy of 94%. The positive predictive value (PPV) and the negative predictive value (NPV) of the infraorbital rim reached 69% and 83%, respectively. CT evaluation of the orbital floor showed a sensitivity of 96%, a specificity of 71%, and an accuracy of 96%. PPV and NPV resulted in 71% and 93%, respectively. US investigation of the infraorbital rim yielded a sensitivity of 77%, a specificity of 89%, and an accuracy of 97%, whereas PPV and NPV reached 65% and 83%, respectively. US investigation of the orbital floor reached a sensitivity of 94%, a specificity of 57%, and an accuracy of 96%, whereas PPV and NPV yielded 57% and 91%, respectively. No significant difference was found between US and CT in the investigation of the infraorbital rim (P =.809) and the orbital floor (P =.729). CONCLUSIONS: US with a curved-array transducer appears to be a useful alternative method in the investigation of orbital floor fractures. Further studies have to be conducted to reduce the presence of false-negative results.

Adolescent↗

Effectiveness of ultrasonography in determining medial and lateral orbital wall fractures with a curved-array scanner.

PURPOSE: The purpose of the study was to evaluate the diagnostic value of ultrasonography to determine medial and lateral orbital wall fractures. MATERIALS AND METHODS: Sixty-two patients with the clinical diagnosis of an orbital trauma underwent coronal computed tomography (CCT) and ultrasonographic investigation (US). Inclusion criteria were clinically suspected orbital injuries defined by reduced bulbus motility, diplopia, or additional traumatic injuries of the orbit or the globe. US and CCT were used as imaging diagnostic methods. RESULTS: Ultrasonography showed a sensitivity of 56%, a specificity of 95%, and an accuracy of 88% at the medial orbital rim. Regarding the lateral orbital rim, ultrasonography showed a sensitivity of 92%, a specificity of 88%, and an accuracy of 90% using CCT as a reference method. CONCLUSION: Ultrasonography with a curved-array scanner seems to be a valuable method in the detection of lateral orbital wall fractures. Further studies have to be done to improve sensitivity in the interpretation of medial orbital wall fractures.

Adolescent↗

Clinical signs of orbital wall fractures as a function of anatomic location.

OBJECTIVE: The objective of this study was to see whether clinical signs of medial orbital wall fractures distinguished these fractures from fractures of the lateral orbital wall and the orbital floor. STUDY DESIGN: The orbital fractures of 424 patients were analyzed. The patients were divided into 2 groups: (1) patients with orbital fractures with a medial orbital wall component and (2) patients with orbital fractures without a medial orbital wall component. RESULTS: Orbital fractures with involvement of the medial orbital wall showed a significantly higher incidence (P =.001) of diplopia and exophthalmos (P =.039) than fractures without involvement of the medial wall. CONCLUSION: Posttraumatic orbital clinical signs are associated with a higher incidence of medial orbital wall component fracture. Apparent lack of involvement of the medial orbital wall should not be an exclusion criterion for a surgical intervention when clinical orbital signs exist.

Chi-Square Distribution↗

Orbital floor reconstruction with flexible Ethisorb patches: a retrospective long-term follow-up study.

OBJECTIVE: The purpose of the study was to investigate whether a flexible, biodegradable material (Ethisorb) shows better long-term results with regard to diplopia, bulbus motility, and exophthalmos/enophthalmos compared to the use of lyophilized dura-patches and polydioxanone (PDS) foils. METHODS: During a period of 6 years 435 patients with an orbital fracture were investigated retrospectively. Inclusion criteria were patients with fractures of the orbital floor with a maximum size of 2 x 2 cm. Bulbus motility, exophthalmos, enophthalmos, and diplopia were investigated during a period of 2 years. RESULTS: One hundred twenty orbital floors were reconstructed by lyophilized dura-patches, 81 by PDS, and 136 by Ethisorb. An exploration without an implantation was performed in 91 patients. The long-term investigation 12 to 15 months after surgery showed an exophthalmos and enophthalmos incidence of 1%, whereas a reduced bulbus motility and diplopia were found in 5% and 4%, respectively. Fifteen to 24 months after surgery 2% of the patients had an exophthalmos and 1% had an enophthalmos. A reduction of bulbus motility was found in 4% of the patients, and diplopia was found in 3%. The use of Ethisorb resulted in a significantly lower incidence of exophthalmos 3 months after surgery compared to PDS. CONCLUSION: The low rate of acquired bulbus motility demonstrates acceptable results in using Ethisorb in the floor of the orbit.

Absorbable Implants↗

Are high-resolution ultrasonographic signs of disc displacement valid?

PURPOSE: The study goal was to define the positive predictive value (PPV) for the diagnosis of disc displacement of the temporomandibular joint (TMJ) with the use of high-resolution ultrasonography (HR-US). MATERIALS AND METHODS: The HR-US reports for 29 patients aged 19 to 62 years who had a prospective clinical diagnosis of TMJ internal derangement were correlated with magnetic resonance results. RESULTS: For the prospective HR-US interpretation, the PPV for disc displacement was 97% at the closed-mouth position and 88% at the maximum-mouth opening position. CONCLUSION: The PPV for the HR-US diagnosis of disc displacement is high.

Adult↗

Error patterns and observer variations in the high-resolution ultrasonography imaging evaluation of the disk position of the temporomandibular joint.

OBJECTIVES: The purpose of this study was (1) to describe errors in the interpretation of high-resolution ultrasonography (HR-US) images of the temporomandibular joint (TMJ) and analyze the discrepancies between HR-US imaging and diagnostic magnetic resonance imaging findings, and (2) to measure interobserver and intraobserver variations with respect to reporting HR-US images of the TMJ. STUDY DESIGN: The sonographic reports of 208 patients aged 13 to 78 years who had a prospective clinical diagnosis of TMJ internal derangement were correlated with magnetic resonance imaging results. Prospective and retrospective readings were used to classify types of disk displacement. Assessment of observer variation was based on a set of 200 HR-US images in 50 randomly selected patients. The images were interpreted independently by 2 trained radiologists at 2 sessions, 1 to 2 weeks apart. RESULTS: Prospective interpretation of TMJ HR-US images at the closed-mouth position had a sensitivity of 80%, specificity of 87%, and accuracy of 82%. For images at the maximum mouth-opening position, the sensitivity was 68%, specificity 93%, and accuracy 82%. The number of diagnostic errors at retrospective analysis was 60.3% (n = 73) of the number at prospective analysis. The intraobserver agreement for reporting the disk position at the closed-mouth position was 93% and at the maximum mouth-opening position was 88%. The agreement between the 2 observers was 89% on the position of the disk at the closed-mouth position and 84% at the maximum mouth-opening position. CONCLUSIONS: The high diagnostic accuracy, together with the low observer variation reported in this study, suggest that HR-US of the TMJ is a valuable imaging technique for assessment of disk displacement. Many errors that occur at prospective analysis didn't occur at retrospective analysis.

Adolescent↗

Disk displacement of the temporomandibular joint: sonography versus MR imaging.

OBJECTIVE: The purpose of this study was to determine the value of dynamic sonography in the evaluation of internal derangements of a temporomandibular joint (TMJ) during maximal mandibular range of motion. SUBJECTS AND METHODS: Maximal mandibular range of motion was performed during high-resolution sonography of the TMJ in 64 consecutive patients (128 joints; nine males and 55 females; age range, 17-65 years; mean age, 35 years 6 months), all of whom subsequently underwent MR imaging. MR imaging confirmed disk displacement with reduction in 27 joints and disk displacement without reduction in 60 joints of the 128 examined. The high-resolution sonography and MR imaging findings for these 27 and 60 TMJs, respectively, were analyzed. RESULTS: Dynamic high-resolution sonography performed during the maximal range of motion helped to detect 81 instances (93%) of internal derangement, 22 instances (82%) of disk displacement with reduction, and 50 instances (83%) of disk displacement without reduction. There was one false-positive finding for internal derangement. The accuracy of prospective interpretation of high-resolution sonograms of internal derangement, disk displacement with reduction, and disk displacement without reduction was 95%, 92%, and 90%, respectively. CONCLUSION: When real-time images are interpreted by expert radiologists, dynamic sonography performed during maximal mandibular range of motion may provide valuable information about disk displacement of the TMJ.

Adolescent↗