PubMed Health⌕ Search

Biomedical subjects

Sigita Burneikiene

Publications and source records attributed to Sigita Burneikiene.

6 recordsLinked to original sources

Back and neck pain in triathletes.

OBJECT: As the sport of triathlon has continued to grow, increasing numbers of triathletes have presented in the neurosurgery clinics with various spinal disorders. This epidemiological study was undertaken to establish the lifetime incidence of neck and back pain, to gauge the prevalence of discogenic pain, and to identify risk factors among triathletes in the Boulder, Colorado, area. METHODS: A live online questionnaire was developed that was used to collect information about physical characteristics, training habits, athletic status, number of races completed, and back pain among triathletes. The incidence of cervical and/or lumbar discogenic back pain was defined according to the duration of symptoms for the most recent pain episode. The lifetime incidence of low-back pain was 67.8%, with 23.7% of cases possibly being discogenic in origin. The number of triathlons in which the respondents had participated and the presence of previous sports-related injuries were predictive of low-back pain (p = 0.02 and p < 0.00001, respectively). The lifetime incidence of neck pain was 48.3%, with 21.4% of cases being consistent with intervertebral disc involvement. The number of previous sports-related injuries was predictive of neck pain (p < 0.00001), and a strong tendency toward neck pain was observed for athletes with more total years of participation in sports (p = 0.06). CONCLUSIONS: The two main risk factors for long-term spinal problems include sports-related injuries and overuse. The study results definitely support the influence of both mechanisms for low-back pain. Neck pain was associated with an injury event, and a strong (although not statistically significant) tendency toward neck pain was observed in respondents with overuse injuries.

Adolescent↗

Perioperative complications in transforaminal lumbar interbody fusion versus anterior-posterior reconstruction for lumbar disc degeneration and instability.

OBJECTIVES: Multiple different approaches are used to treat lumbar degenerative disc disease and spinal instability. Both anterior-posterior (AP) reconstructive surgery and transforaminal lumbar interbody fusion (TLIF) provide a circumferential fusion and are considered reasonable surgical options. The purpose of this study was to quantitatively assess clinical parameters such as surgical blood loss, duration of the procedure, length of hospitalization, and complications for TLIF and AP reconstructive surgery for lumbar fusion. METHODS: A retrospective analysis was completed on 167 consecutive cases performed between January 2002 and March 2004. TLIF surgical procedure was performed on 124 patients, including 73 minimally invasive and 51 open cases. AP surgery was performed on 43 patients. Patients were treated for painful degenerative disc disease, facet arthropathy, degenerative instability, and spinal stenosis. RESULTS: The mean operative time for AP reconstruction was 455 minutes, for minimally invasive TLIF 255 minutes, and open TLIF 222 minutes. The mean blood loss for AP fusion surgery was 550 mL, for minimally invasive TLIF 231 mL, and open TLIF 424 mL. The mean hospitalization time for AP reconstruction was 7.2 days, for minimally invasive TLIF 3.1 days, and open TLIF 4.1 days. The total rate of complications was 76.7% for AP reconstruction, including 62.8% major and 13.9% minor complications. The minimally invasive TLIF patients group had the total 30.1% rate of complications, 21.9% of which were minor and 8.2% major complications. There were no major complications in the open TLIF patients group, with 35.3% minor complications. CONCLUSIONS: AP lumbar interbody fusion surgery is associated with a more than two times higher complication rate, significantly increased blood loss, and longer operative and hospitalization times than both percutaneous and open TLIF for lumbar disc degeneration and instability.

Adult↗

CyberKnife radiosurgery for idiopathic trigeminal neuralgia.

OBJECT: Gamma knife surgery is an accepted treatment option for trigeminal neuralgia (TN). The safety and efficacy of CyberKnife radiosurgery as a treatment option for TN, however, has not been established. METHODS: Forty-one patients were treated between May 2002 and September 2004 for idiopathic TN at Stanford University and the Rocky Mountain CyberKnife Center. Patients with atypical pain, multiple sclerosis, or previous radiosurgical treatment or a follow-up duration of less than 6 months were excluded. Patients were evaluated for the level of pain control, response rate, time to pain relief, occurrence of hypesthesia, and time to pain recurrence with respect to the length of the nerve treated and the maximum and the minimum dose to the nerve margin. Thirty-eight patients (92.7%) experienced initial pain relief at a median of 7 days after treatment (range, 24 hours-4 months). Pain control was ranked as excellent in 36 patients (87.8%), moderate in two (4.9%), and three (7.3%) reported no change. Six (15.8%) of the 38 patients with initial relief experienced a recurrence of pain at a median of 6 months (range 2-8 months). Long-term response after a mean follow-up time of 11 months was found in 32 (78%) of 41. Twenty-one patients (51.2%) experienced numbness after treatment. CONCLUSIONS: CyberKnife radiosurgery for TN has high rates of initial pain control and short latency to pain relief compared with those reported for other radiosurgery systems. The doses used for treatment were safe and effective. Higher prescribed doses were not associated with improvement in pain relief or recurrence rate. The hypesthesia rate was related to the length of the trigeminal nerve treated.

Adult↗

Intraoperative three-dimensional fluoroscopy-based computerized tomography guidance for percutaneous kyphoplasty.

OBJECT: Percutaneous kyphoplasty is an established method for the treatment of pathological vertebral compression fractures (VCFs). This procedure is usually performed with the aid of biplanar fluoroscopic image guidance. There are currently no published clinical studies in which the use of three-dimensional (3D) image guidance to facilitate this technique has been evaluated. The purpose of this study was to evaluate the efficacy of isocentric fluoroscopy-based navigation for the kyphoplasty procedure, with special reference to operating time and the amount of radiation exposure. METHODS: A prospective clinical study was performed in which 11 consecutive patients with painful pathological VCFs that did not respond to conservative treatment underwent the kyphoplasty procedure. During this procedure, cannulation of the pedicle and vertebral body was performed with the aid of isocentric 3D fluoroscopy visualization. Total operating time and intraoperative fluoroscopy time for this group was compared with a cohort of nine patients who underwent the procedure prior to the availability of isocentric fluoroscopy (only biplanar fluoroscopy was used). Possible complications such as cement extravasations were evaluated during the procedure and on postoperative computerized tomography scans. The mean duration of surgery for the 3D isocentric fluoroscopic guidance group was 60 minutes (range 36-89 minutes) for one-level and 68.5 minutes (range 65-75 minutes) for two-level cases. Because of a learning curve with the equipment, the operating time for the initial cases was significantly longer than with the later ones. Even with the initial cases included, the mean operating time was shorter compared with the biplanar fluoroscopy-assisted procedures, which averaged 69.2 minutes (range 44-113 minutes) for one-level procedures. This difference was not statistically significant. The mean fluoroscopy exposure time was 41.3 seconds (range 25-62 seconds) in the isocentric fluoroscopy-assisted procedures, with an additional 40 seconds of fluoroscopy time used for the 3D fluoroscopy "spin," compared with 293.2 seconds (range 180-400 seconds) in the biplanar fluoroscopy-assisted procedures. The difference was statistically significant (p = 0.02). All pedicles were accessed without difficulty and no complications were encountered in either group of patients. CONCLUSIONS: The main advantage of isocentric fluoroscopy is the significant reduction in radiation exposure for the patient and surgical staff without an increase in the mean operating time. This technique is a significant advancement over biplanar fluoroscopy in this setting.

Adult↗

Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques.

OBJECTIVE: The purpose of this study was to prospectively evaluate the clinical utility and accuracy of intraoperative three-dimensional fluoroscopy as an adjunct for the placement of a complex spinal instrumentation. METHODS: The Siemens Iso-C three-dimensional fluoroscopy unit in the combination with the Stealth Treon computer volumetric navigational system was used. A total of 279 spinal instrumentation screws or transpedicular cannulations were performed in 69 patients. Accuracy, operative time, and amount of fluoroscopy utilization time were assessed for transforaminal lumbar interbody fusion (TLIF) and kyphoplasty cases. RESULTS: Only 4 percutaneous transpedicular lumbar screws out of 265 total (1.5%) were malpositioned. Average operative time for TLIF cases was 185 minutes (range 114-311 minutes) for one-level and 292.6 minutes (range 173-390 minutes) for two-level procedures. Biplanar fluoroscopy utilization time was 93 seconds (range 27-280 seconds) for one-level procedures and 216 seconds (range 80-388 seconds) for two-level procedures. Average surgery duration for kyphoplasty was 60 minutes (range 36-79 minutes) for one-level procedures and 68.5 minutes (range 65-75 minutes) for two-level cases. Biplanar fluoroscopy utilization time was 41.3 seconds per case (range 25-62 seconds). CONCLUSIONS: Use of intraoperative three-dimensional fluoroscopy for image guidance in minimally invasive complex spinal instrumentation procedures is feasible and safe. This technique provides excellent visualization of three-dimensional relationships. This potentially results in improved accuracy of screw positioning and the ability to detect misplaced screws prior to wound closure. This technique also potentially results in a significant reduction in radiation exposure for both the patient and the staff.

Adult↗

Safety of transforaminal lumbar interbody fusion and intervertebral recombinant human bone morphogenetic protein-2.

OBJECT: Recombinant human bone morphogenetic protein-2 (rhBMP-2) is being increasingly used for spinal fusion. There are few data regarding its clinical safety, effectiveness, and clinical outcome when applied on an absorbable collagen sponge (ACS) in conjunction with allograft for transforaminal lumbar interbody fusion (TLIF). METHODS: Seventy-four consecutive patients undergoing TLIF for degenerative disc disease were divided into five groups depending on whether the patient underwent a minimally invasive or open approach, as well as the number of spinal levels surgically treated. Surgery-related data, fusion results, complications, and clinical outcome were evaluated. The mean follow-up duration was 20.6 months (range 14-28 months). The radiographic fusion rate was 100% at 12 and 24 months after the surgery. No bone overgrowth or other complications related to BMP use were demonstrated. CONCLUSIONS: Analysis of the results demonstrated that TLIF combined with a BMP-2-soaked ACS is a feasible, effective, and safe method to promote lumbar fusion. There were no significant intergroup differences in clinical outcome between patients who underwent open compared with minimally invasive procedures. Patient satisfaction rates, however, were higher in the minimally invasive procedure group. The efficacy of BMP-2 was not dependent on which approach was used or the number of spinal levels that were treated.

Absorbable Implants↗