PubMed Health⌕ Search

Biomedical subjects

Sigmar Mello Rode

Publications and source records attributed to Sigmar Mello Rode.

5 recordsLinked to original sources

Increases in intrapulpal temperature during polymerization of composite resin.

STATEMENT OF PROBLEM: The polymerization of dental composite resins can generate increases in intrapulpal temperature that may damage the pulp. The development of new polymerization devices such as the argon laser makes the assessment of these temperatures important. PURPOSE: This study compared increases in temperature generated by argon laser and halogen light when polymerizing a bonding system and a composite resin, and also sought to determine whether both types of polymerization lights generate temperature increases below the safe limit of 5.5 degrees C. MATERIAL AND METHODS: Thermocouples linked to a temperature reading system were positioned in the pulp chamber of 10 extracted bovine incisors. Class V cavities were prepared, etched, and filled with a 1-bottle bonding system (Single Bond) and composite resin (Z-100). The test groups were as follows (n = 5 for all groups): halogen light for bonding system (HB); halogen light for composite resin (HC); argon laser for bonding system (LB), and argon laser for composite resin (LC). The polymerization parameters were halogen light operated at 600 mW/cm2 for 40 seconds, which served as control, and argon laser operated at 200 mW for 10 seconds. Data were analyzed by a 2-way (light versus material) analysis of variance (ANOVA) (alpha = .05). RESULTS: The average temperature increases were 2.35 degrees C (HB), 2.69 degrees C (HC), 1.25 degrees C (LB), and 1.5 degrees C (LC). Significant differences between halogen light and argon laser (P = .002), but not between composite and bonding system, were demonstrated. CONCLUSIONS: The argon laser produced significantly lower increases in pulpal temperature than the halogen light, independent of the thickness of the polymerized material.

Analysis of Variance↗

Water flow in high-speed handpieces.

OBJECTIVES: This study measured the water flow commonly used in high-speed handpieces to evaluate the water flow's influence on temperature generation. Different flow speeds were evaluated between turbines that had different numbers of cooling apertures. METHOD AND MATERIALS: Two water samples were collected from each high-speed handpiece at private practices and at the School of Dentistry at São José dos Campos. The first sample was collected at the customary flow and the second was collected with the terminal opened for maximum flow. The two samples were collected into weighed glass receptacles after 15 seconds of turbine operation. The glass receptacles were reweighed and the difference between weights was recorded to calculate the water flow in mL/min and for further statistical analysis. RESULTS: The average water flow for 137 samples was 29.48 mL/min. The flow speeds obtained were 42.38 mL/min for turbines with one coolant aperture; 34.31 mL/min for turbines with two coolant apertures; and 30.44 mL/min for turbines with three coolant apertures. There were statistical differences between turbines with one and three coolant apertures (Tukey-Kramer multiple comparisons test with P < .05). CONCLUSION: Turbine handpieces with one cooling aperture distributed more water for the burs than high-speed handpieces with more than one aperture.

Body Temperature↗

Effects of copper vapor laser irradiation (lambda = 510.6 nm) on the enamel and dentine of human teeth: an ultra-structural morphologic study.

OBJECTIVE: A morphological and ultra-structural study of copper vapor laser (lambda = 510.6 nm) effects on enamel and dentine was performed to show the effects of this radiation. METHODS: A total of 15 human molars were cut in half; 15 pieces were separated for irradiation on enamel and 15 for dentine. These two groups were further divided into five experimental groups, including a control group, comprised of three half-sections each, irradiated by a CVL laser with a power of 7 W, a repetition rate of 15,000 pulses/sec and exposed at 500, 600, and 800 msec and 1 sec irradiation times with a 5-sec interval between irradiations. RESULTS: In an ultra-structural SEM exam, we observed that on the enamel surfaces irradiated for 1 sec there was morphological alteration that consisted of catering, flaking, and melting on the surfaces. There was no alteration for the other exposure times. On the dentine teeth irradiated for 1 sec, we observed an evident ultra-structural alteration of melted tissue and loss of morphological characteristics. In the dentine group irradiated by 800 msec, we observed ablation and a partial loss of morphological characteristics. In the dentine groups irradiated by 500 and 600 msec, no alteration was observed. CONCLUSIONS: The results showed that irradiation with CVL promoted morphologic changes in the enamel as well as in the dentine and demonstrated a need for future studies in order to establish a safe protocol for further use in the odontological practice.

Copper↗

Pulpal temperature increases with Er:YAG laser and high-speed handpieces.

STATEMENT OF PROBLEM: During tooth preparation, both high-speed handpieces and lasers generate heat, which, if not controlled, can cause pulpal necrosis. PURPOSE: The aim of this study was to compare temperature increases produced by a high-speed dental handpiece with those produced by a relatively new instrument, the Er:YAG (erbium: yttrium-aluminum-garnet) laser. MATERIALS AND METHODS: Thirty bovine mandibular incisors were reduced to an enamel/dentin thickness of 2.5 mm. Class V preparations were completed to a depth of 2.0 mm, measured with a caliper or by a mark on the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (degrees C). Analysis was performed on the following groups (n=10): Group I, high-speed handpiece without water cooling, Group II, high-speed handpiece with water cooling (30 mL/min), and Group III, the noncontact Er:YAG laser (2.94 microm at 350 mJ/10 Hz) with water cooling (4.5 mL/min). The temperature increases were recorded by a computer linked to the thermocouples. The data were analyzed using the Kruskal-Wallis test. The Dunn multiple comparison test was used as post hoc test (alpha=.05). RESULTS: The average temperature rises were: 11.64 degrees C (+/- 4.35) for Group I, 0.96 degrees C (+/- 0.71) for Group II, and 2.69 degrees C (+/- 1.12) for Group III. There were no statistical differences between Groups II and III; both II and III differed from Group I significantly (P=.000 and P=.002, respectively). CONCLUSION: The preparations made with the high-speed and the laser instrument generated similar heat increases under water cooling. Water cooling was essential to avoid destructive temperature increases when using both the high-speed handpiece and laser.

Aluminum Silicates↗

High-speed cavity preparation techniques with different water flows.

STATEMENT OF PROBLEM: Cavity and tooth preparations generate heat because the use of rotary cutting instruments on dental tissues creates friction. Dental pulps cannot survive temperature increases greater than 5.5 degrees C. PURPOSE: This study evaluated the efficiency of 3 different water flows for 2 different tooth preparation techniques to determine which are safe for use. MATERIAL AND METHODS: Thermocouples were placed in the pulpal chambers of 30 bovine teeth, and 1 of 2 tooth preparation techniques was used: a low-load intermittent tooth preparation technique or a high-load tooth preparation technique without intervals. Water flows of 0, 30, and 45 mL/min were associated with each technique, for a total of 6 different groups. The results were analyzed with a 2-factor analysis of variance (P<.05). RESULTS: Temperature increases with the high-load technique were 16.40 degrees C without cooling (group I), 11.68 degrees C with 30 mL/min air-water spray cooling (group III), and 9.96 degrees C with 45 mL/min cooling (group V). With the low-load tooth preparation technique, a 9.54 degrees C increase resulted with no cooling (group II), a 1.56 degrees C increase with 30 mL/min air-water spray cooling (group IV), and a 0.04 degrees C decrease with 45 mL/min cooling (group VI). The low-load technique was associated with more ideal temperature changes. CONCLUSION: The results of this study confirm the necessity of using a low-load technique and water coolants during cavity and tooth preparation procedures.

Animals↗