Biomechanical characterization of needle piercing into peripheral nervous tissue.

Several neural interfaces have been developed to control neuroprostheses and hybrid bionic systems. Among them, intraneural electrodes are very promising because they represent an interesting trade-off between the needs for high selectivity and for reduced invasiveness. However, in most of the cases, no particular attention has been devoted so far to the design of these systems starting from the mechanical properties of the system to be interfaced. The aim of this paper was to study and characterize in a quantitative way the piercing of peripheral nervous tissue in order to gather useful information to design intraneural interfaces able to reduce (as much as possible) the damages provoked by this task. In particular, attention has been paid to determine the values of force and pressure to carry out the piercing task in different velocity conditions. From the experimental data it was possible to characterize indirectly the tissue sinking under the needle tip. For each experimental velocity (ranging from 1 to 2000 mm/min) a threshold, under which the tissue cannot be pierced, has been calculated. The force magnitude required for piercing was shown to be in the range 0.3-25 mN for the different velocities. Moreover, differences between piercing carried out at very low velocity (multi-piercing) and at low velocity (mono-piercing) have been characterized and correlated with the physical characteristics of the nervous tissue. Experimental data have been integrated with a theoretical analysis of the neural interfaces piercing structures. The problem of buckling, representing for these structures the main cause of tissue piercing impossibility, has been analyzed. The nonlinear theoretical model allows to compare different needle geometries and materials with regard to piercing possibility at different velocities. Moreover, an optimization of piercing elements geometry with regard to amount of used material and space has been provided.

Animals↗

On the development of a biomechatronic system to record tendon sliding movements.

The main goal of this paper is to study the feasibility of a novel implantable micro-system able to record information about tendon sliding movements by using contactless measurement devices (magnetic sources and sensors). The system, named "Biomechatronic Position Transducer" (BPT), can be used for the implementation of advanced control strategies in neuroprostheses. After a preliminary analysis based on finite element model simulations, an experimental setup was developed in order to simulate the recording conditions (the sensors fixed to the bones and the magnetic sources placed on the tendons). In order to limit the number of implanted components of the system, a fuzzy Mamdani-like architecture was developed to extract the information from the raw data. The results confirm the possibility of using the presented approach for developing an implantable micro-sensor able to extract kinematic information useful for the control of neuroprostheses. Future works will go in the direction of integrating and testing the sensors and the electronic circuitry (to provide power supply and to record the data) during in vitro and in situ experiments.

Biomechanical Phenomena↗

Robotic techniques for upper limb evaluation and rehabilitation of stroke patients.

This paper presents two robot devices for use in the rehabilitation of upper limb movements and reports the quantitative parameters obtained to characterize the rate of improvement, thus allowing a precise monitoring of patient's recovery. A one degree of freedom (DoF) wrist manipulator and a two-DoF elbow-shoulder manipulator were designed using an admittance control strategy; if the patient could not move the handle, the devices completed the motor task. Two groups of chronic post-stroke patients (G1 n = 7, and G2 n = 9) were enrolled in a three week rehabilitation program including standard physical therapy (45 min daily) plus treatment by means of robot devices, respectively, for wrist and elbow-shoulder movements (40 min, twice daily). Both groups were evaluated by means of standard clinical assessment scales and a new robot measured evaluation metrics that included an active movement index quantifying the patient's ability to execute the assigned motor task without robot assistance, the mean velocity, and a movement accuracy index measuring the distance of the executed path from the theoretic one. After treatment, both groups improved their motor deficit and disability. In G1, there was a significant change in the clinical scale values (p < 0.05) and range of motion wrist extension (p < 0.02). G2 showed a significant change in clinical scales (p < 0.01), in strength (p < 0.05) and in the robot measured parameters (p < 0.01). The relationship between robot measured parameters and the clinical assessment scales showed a moderate and significant correlation (r > 0.53 p < 0.03). Our findings suggest that robot-aided neurorehabilitation may improve the motor outcome and disability of chronic post-stroke patients. The new robot measured parameters may provide useful information about the course of treatment and its effectiveness at discharge.

Aged↗

A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems.

Considerable scientific and technological efforts have been devoted to develop neuroprostheses and hybrid bionic systems that link the human nervous system with electronic or robotic prostheses, with the main aim of restoring motor and sensory functions in disabled patients. A number of neuroprostheses use interfaces with peripheral nerves or muscles for neuromuscular stimulation and signal recording. Herein, we provide a critical overview of the peripheral interfaces available and trace their use from research to clinical application in controlling artificial and robotic prostheses. The first section reviews the different types of non-invasive and invasive electrodes, which include surface and muscular electrodes that can record EMG signals from and stimulate the underlying or implanted muscles. Extraneural electrodes, such as cuff and epineurial electrodes, provide simultaneous interface with many axons in the nerve, whereas intrafascicular, penetrating, and regenerative electrodes may contact small groups of axons within a nerve fascicle. Biological, technological, and material science issues are also reviewed relative to the problems of electrode design and tissue injury. The last section reviews different strategies for the use of information recorded from peripheral interfaces and the current state of control neuroprostheses and hybrid bionic systems.

Animals↗

Automated assessment of cervical dystonia.

We developed an automated and objective method to measure posture and voluntary movements in patients with cervical dystonia using Fastrack, an electromagnetic system consisting of a stationary transmitter station and four sensors. The junction lines between the sensors attached to the head produced geometrical figures on which the corresponding aspects of the head were superimposed. The head position in the space was reconstructed and observed from axial, sagittal, and coronal planes. Four patients with cervical dystonia and 6 healthy subjects were studied. Each patient was representative of one of the typical patterns of cervical dystonia. The study allowed the authors to collect quantitative data on posture and range of motion of the head. This pilot study demonstrates the efficacy of the Fastrack system to objectively measure the head position in cervical dystonia patients.

Adult↗

On the intersubject generalization ability in extracting kinematic information from afferent nervous signals.

In the recent past, many efforts have been carried out in order to evaluate the feasibility of implementing closed-loop controlled neuroprostheses based on the processing of sensory electroneurographic (ENG) signals. The success of these techniques mostly relies on the development of processing algorithms capable of extracting the necessary kinematic information from these signals. Soft-computing algorithms can be very useful when dealing with the complexity of the neuromuscular system because of their generalization ability and model-free structure. In this paper, these techniques were used to extract angular position information from the ENG signals recorded from muscle afferents in animal model using cuff electrodes. Specifically, a genetic algorithm-based dynamic nonsingleton fuzzy logic system (named GA-DNSFLS) was developed and tested on different types of angular trajectories (characterized by small or large angular excursions). In particular, two different Takagi-Sugeno-Kang (TSK)-like structures were used in the consequent part of the neuro-fuzzy model in order to verify which one could improve the generalization abilities (intrasubject and intersubject). The results showed that the GA-DNSFLS was able to reconstruct the trajectories giving interesting results in terms of correlation between the actual and the predicted trajectories for small excursion movements during intrasubject and intersubject tests. Particularly, one of the TSK models showed better results in terms of intersubject generalization. The simulations conducted with the large excursion movements led in some cases to interesting results but further experiments are necessary in order to analyze this point more in deep.

Action Potentials↗

A sensorized thumb for force closed-loop control of hand neuroprostheses.

In this paper, we presented a sensorized thumb based on a matrix of piezoresistive force sensors, with an acquisition unit and a special wearing support. The sensor was calibrated and then the device was tested during different tasks simulating activities of daily living performed by seven able-bodied subjects. By means of these experiments, we verified that the device proposed can be used to extract force information during grasp. In fact, the device was able to provide useful force information in the 98% of the trials with a good repeatability during all the different conditions. Moreover, we evaluated the patterns obtained during the different grasping tasks. The palmar grasps were performed in a similar manner, whereas the lateral pinch and the spherical volar grip were more different. This device can provide force information with good performance and acceptability and it can be used for force closed-loop control of hand neuroprostheses.

Activities of Daily Living↗

On the analysis of hand synergies during grasping in weightlessness.

The aim of this paper was to analyse how the strategies implemented by the Central Nervous System to control the hand during grasping are modified under microgravity conditions. Two right-handed subjects carried out simple grasping tasks during parabolic flights. The trajectories of the fingers of the hand were recorded using a sensorised glove and processed in order to extract a variable (here indicated as K) which can indicated the degree of synergies existing among the fingers. The results showed that K was quite small during the trial at 1g while becoming significantly greater than 1 during the first parabolas. Then, the value k decreased to the values at 1 g after some parabolas. These results suggested a possible adaptation process of the manipulation abilities during the permanence at 0g conditions. Future extensive trials will be performed in order to confirm these preliminary results.

Journal Article↗