Capillary zone electrophoresis method for the simultaneous determination of cations in honey.

A capillary electrophoresis system for the simultaneous determination of cations in honey samples has been developed. The complete separation and quantification of K+, Ca2+, Na+, Mg2+, Mn2+, Ni2+ and Li+, which represent more than 99% of the total content of cations in honey, can be achieved in 4 min with only a dilution and filtration of the honey sample. Electrolyte solution was composed by 10 mM imidazole as the carrier buffer and background absorbance provider and acetic acid as the complexing agent (pH 3.60). The running voltage was + 25 kV at 25 degree C. Indirect UV detection was achieved at 185 nm. Under the optimum conditions the detection limits ranged from 0.02 to 48.2 mg/kg and the quantification limits have ranged from 0.41 to 48.7 mg/kg. Precision data in honey samples analysed have shown repeatability and reproducibility RSD (%) lower than 2.84 and 6.62%, respectively. Recoveries of cations in honey samples analysed have ranged from 88.5 to 101.8%. These cations were identified by their relative migration times with regard to Ba2+ migration time used as reference standard and they were quantified by using an external standard calibration. Twenty-five honey samples were analysed to test the proposed method. Mean contents of 1.22 x 10(3), 93, 85, 54, 11, 1.9 and 2.3 mg/kg were found, respectively, for K+, Ca2+, Na+, Mg2+, Mn2+, Ni2+ and Li+ cations in analysed honeys. These results were similar than the obtained by other authors.

Calcium↗

Rapid determination of minority organic acids in honey by high-performance liquid chromatography.

A rapid high-performance liquid chromatographic method for the determination of organic acids in honey is reported. Malic, maleic, citric, succinic and fumaric acids were identified and quantified in 15 min. First time repeatibility, reproducibility and recoveries were determined out for these acids in honey samples. Maleic acid was also quantified for first time by a chromatographic method. The organic acids were removed from honey by using a solid-phase extraction procedure with anion-exchange cartridges. Previously, the solution of honey was adjusted to pH 10.50 with 0.1 M NaOH and stirred for 15 min at room temperature. Then, this solution was adjusted to pH 5.00 with 0.1 M H2SO4. This procedure was carried out to avoid interferences in the baseline. The chromatographic separation was achieved with only one Spherisorb ODS-2 S5 column thermostated at 25 degrees C. Metaphosphoric acid (pH 2.20) was used as mobile phase at a flow-rate of 0.7 ml/min. Organic acids were detected with a UV-vis detector (215 nm). The precision results showed that the relative standard deviations of the repeatability and reproducibility were < or =3.20% and < or =4.86%, respectively. The recoveries of the organic acids ranged from 62.9 to 99.4%. Under optimum conditions the detection limits ranged from 0.0064 to 7.57 mg/kg and the quantification limits ranged from 0.025 to 10.93 mg/kg.

Acids↗

Solid-phase extraction procedure to remove organic acids from honey.

A solid-phase extraction procedure was applied to remove organic acids from honey. Malic, maleic, citric, succinic and fumaric acids were isolated with an anion-exchange cartridge. The different parameters which affected the extraction procedure were studied and optimised to establish the optimal conditions for maximum recovery of organic acids and minimum extraction of interferences. The optimised procedure used a cartridge which was activated with 10 ml of 0.1 M sodium hydroxide solution (percolation rate 3 ml/min). A 10 ml volume of honey solution was passed at a flow-rate of 0.5 ml/min. The cartridge was washed with 10 ml of water (3 ml/min) and organic acids were eluted with 4 ml of 0.1 M sulfuric acid (0.5 ml/min). This solution was injected directly into the chromatograph. When this procedure was carried out on standard solutions of organic acids, recoveries between 99.2 and 103.4% were found. If this procedure was applied to honey samples these recoveries were also satisfactory and ranged from 62.9 to 99.4%.

Acids↗