Linac-integrated 4D cone beam CT: first experimental results.

A new online imaging approach, linac-integrated cone beam CT (CBCT), has been developed over the past few years. It has the advantage that a patient can be examined in their treatment position directly before or during a radiotherapy treatment. Unfortunately, respiratory organ motion, one of the largest intrafractional organ motions, often leads to artefacts in the reconstructed 3D images. One way to take this into account is to register the breathing phase during image acquisition for a phase-correlated image reconstruction. Therefore, the main focus of this work is to present a system which has the potential to investigate the correlation between internal (movement of the diaphragm) and external (data of a respiratory gating system) information about breathing phase and amplitude using an inline CBCT scanner. This also includes a feasibility study about using the acquired information for a respiratory-correlated 4D CBCT reconstruction. First, a moving lung phantom was used to develop and to specify the required methods which are based on an image reconstruction using only projections belonging to a certain moving phase. For that purpose, the corresponding phase has to be detected for each projection. In the case of the phantom, an electrical signal allows one to track the movement in real time. The number of projections available for the image reconstruction depends on the breathing phase and the size of the position range from which projections should be used for the reconstruction. The narrower this range is, the better the inner structures can be located, but also the noise of the images increases due to the limited number of projections. This correlation has also been analysed. In a second step, the methods were clinically applied using data sets of patients with lung tumours. In this case, the breathing phase was detected by an external gating system (AZ-733V, Anzai Medical Co.) based on a pressure sensor attached to the patient's abdominal region with a fixation belt. The comparison of the reconstructed 4D CBCT images and the corresponding 4D CT images used for the treatment planning provides the required information for the calculation of possible setup errors. So, a repositioning of the patient is feasible even though the patient moves due to respiration. In addition to the external signal, the position of the diaphragm in the cranial-caudal direction could be extracted from each projection. Both independent sources of information show a very good agreement of the phase and even the amplitude of the movement and the external signal respectively. This suggests the usability of such a system for a gated dose delivery approach. However, more studies involving patients with different incidences have to be carried out to confirm these first results.

Algorithms↗

Correction of patient positioning errors based on in-line cone beam CTs: clinical implementation and first experiences.

BACKGROUND: The purpose of the study was the clinical implementation of a kV cone beam CT (CBCT) for setup correction in radiotherapy. PATIENTS AND METHODS: For evaluation of the setup correction workflow, six tumor patients (lung cancer, sacral chordoma, head-and-neck and paraspinal tumor, and two prostate cancer patients) were selected. All patients were treated with fractionated stereotactic radiotherapy, five of them with intensity modulated radiotherapy (IMRT). For patient fixation, a scotch cast body frame or a vacuum pillow, each in combination with a scotch cast head mask, were used. The imaging equipment, consisting of an x-ray tube and a flat panel imager (FPI), was attached to a Siemens linear accelerator according to the in-line approach, i.e. with the imaging beam mounted opposite to the treatment beam sharing the same isocenter. For dose delivery, the treatment beam has to traverse the FPI which is mounted in the accessory tray below the multi-leaf collimator. For each patient, a predefined number of imaging projections over a range of at least 200 degrees were acquired. The fast reconstruction of the 3D-CBCT dataset was done with an implementation of the Feldkamp-David-Kress (FDK) algorithm. For the registration of the treatment planning CT with the acquired CBCT, an automatic mutual information matcher and manual matching was used. RESULTS AND DISCUSSION: Bony landmarks were easily detected and the table shifts for correction of setup deviations could be automatically calculated in all cases. The image quality was sufficient for a visual comparison of the desired target point with the isocenter visible on the CBCT. Soft tissue contrast was problematic for the prostate of an obese patient, but good in the lung tumor case. The detected maximum setup deviation was 3 mm for patients fixated with the body frame, and 6 mm for patients positioned in the vacuum pillow. Using an action level of 2 mm translational error, a target point correction was carried out in 4 cases. The additional workload of the described workflow compared to a normal treatment fraction led to an extra time of about 10-12 minutes, which can be further reduced by streamlining the different steps. CONCLUSION: The cone beam CT attached to a LINAC allows the acquisition of a CT scan of the patient in treatment position directly before treatment. Its image quality is sufficient for determining target point correction vectors. With the presented workflow, a target point correction within a clinically reasonable time frame is possible. This increases the treatment precision, and potentially the complex patient fixation techniques will become dispensable.

Automation↗

The influence of breathing motion on intensity modulated radiotherapy in the step-and-shoot technique: phantom measurements for irradiation of superficial target volumes.

For intensity modulated radiotherapy (IMRT) of deep-seated tumours, dosimetric variations of the original static dose profiles due to breathing motion can be primarily considered as blurring effects known from conventional radiotherapy. The purpose of this dosimetric study was to clarify whether these results are transferable to superficial targets and to quantify the additional effect of fractionation. A solid polystyrene phantom and an anthropomorphic phantom were used for film and ion chamber dose measurements. The phantoms were installed on an electric driven device and moved with a frequency of 6 or 12 cycles per minute and an amplitude of 4 mm or 10 mm. A split beam geometry of two adjacent asymmetric fields and an IMRT treatment plan with 12 fields for irradiation of the breast were investigated. For the split beam geometry the dose modifications due to unintended superposition of partial fields were reduced by fractionation and completely smoothed out after 20 fractions. IMRT applied to the moving phantom led to a more homogeneous dose distribution compared to the static phantom. The standard deviation of the target dose which is a measure of the dose homogeneity was 10.3 cGy for the static phantom and 7.7 cGy for a 10 mm amplitude. The absolute dose values, measured with ionization chambers, remained unaffected. Irradiation of superficial targets by IMRT in the step-and-shoot technique did not result in unexpected dose perturbations due to breathing motion. We conclude that regular breathing motion does not jeopardize IMRT of superficial target volumes.

Breast↗

Linac-integrated kV-cone beam CT: technical features and first applications.

One of the most prominent imaging techniques in image-guided radiotherapy (IGRT) is the acquisition of cone beam computed tomographies (CBCTs) at the linac with the patient in treatment position. CBCTs provide accurate 3-dimensional (3D) knowledge about the patient's anatomy for every treatment fraction and are therefore well suited for all adaptive corrections of errors related to interfractional uncertainties of the treatment process. In this paper, we first describe the technical development and implementation of this new imaging technique at our linac, i.e., the hardware components and their operating parameters are discussed in detail for a standard image acquisition of CBCTs. Then, an extension of this approach for the acquisition of complete images for extended field of views--the "shifted detector" technique--is presented followed by a first investigation of how CBCTs can be reliably used for adaptive dose calculations. Finally, a first clinical application, the process of automatic patient positioning based on CBCT images, is discussed. From our investigations, we conclude that the technical development of linac-integrated CBCTs bears an enormous potential for the correction of interfractional treatment errors. However, image quality and reconstruction speed of the images leave room for improvement. The development of clinical strategies for the optimal application of this new image modality in a clinical environment is one the major tasks for the future.

Humans↗

Online correction for respiratory motion: evaluation of two different imaging geometries.

One aim of adaptive radiotherapy (ART) is the observation of organ motion followed by a subsequent adaptation of the treatment plan. One way of achieving this goal is a kV x-ray source mounted at a linear accelerator in combination with a flat-panel imager. Two imaging hardware configurations were evaluated for their potential for online tracking and the subsequent correction of organ motion by using fluoroscopic images: x-ray tube positioned with (A) 90 degrees and (B) 180 degrees offset to the MV beam. For one lung case two IMRT plans with five coplanar beams and the table positioned at 0 degrees were optimized for two multileaf collimators (MLCs) with 10 mm and 2.75 mm leaf width. Respiratory motion, modelled by rigid transformation in the lungs, was investigated for different amplitudes. The 3D dose distributions for different cases (no movement, uncorrected movement, correction for the movement perpendicular to the respective kV beam) were evaluated with the help of dose volume histograms (DVHs) and a modified conformity (Baltas et al 1998 Int. J. Radiat. Oncol. Biol. Phys. 40 515-24) and coverage index using the 90% isodose. For the corrected treatment plans the influence of the observed displacement vector caused by organ movement was accounted for by a respective displacement of the target point. For the simulated movement with a small amplitude (3 mm) in the anterior-posterior (AP) direction the dose distributions resulting from the correction of the displacement vector using imaging system A or B showed similar results for both systems and were in good agreement with the dose distribution of the static (not moving) patient. Increasing the amplitude in the AP direction to 6 mm or even 9 mm leads for both amplitudes and both MLCs to almost the same conformity and coverage index as the static dose distribution if imaging system B is used for the online correction. For the dose distribution obtained with correction based on imaging system A the deviation between the optimal and the corrected dose distribution is increasing with increasing amplitude. For the MLC with the smaller leaf width the difference between the optimal and the corrected dose distributions is always significantly larger than for the less conformal dose distributions created by the MLC with the 10 mm leaves. These results can be explained by the fact that system A cannot observe movement in the AP-LR plane perpendicular to the MV beam and therefore cannot correct for these movements whereas system B only fails to observe the motion in the beam direction which for photon irradiation has less impact on the dose distribution.

Body Burden↗

Compensation for respiratory motion by gated radiotherapy: an experimental study.

Respiratory organ motion is known to be one of the largest intrafractional organ motions. Therefore, it is important to investigate the potential benefit of gated dose delivery approaches which aim to account for the respective dose uncertainties. In this study respiration is simulated by a moving lung phantom; the movement is not restricted to a normal sinusoidal progression and simulates the one of the embedded lung tumour in the cranial-caudal direction. An IMRT plan with a total of 29 beam segments was designed for the treatment of this tumour. It was irradiated in its resting position-which is the position at exhalation-and during movement. Furthermore the irradiation was triggered using different amplitude thresholds, which means that the irradiation only proceeded if the deviation of the tumour's position from its resting position is smaller than the given threshold. We determined the gating-related increase of the treatment time for various gating procedures. We also measured the resulting dose distribution in specific slices of the phantom perpendicular to the direction of the movement using film dosimetry and compared it to the dose distribution of the static case. Since these film measurements cannot be done inside the whole tumour, additionally the movement and gating was simulated using the planning software to calculate the 3D dose distribution inside the tumour and to generate dose volume histograms for different treatment modalities. The total treatment time was observed to increase by 20%-100% depending on the individual gating threshold and can be calculated easily. The analysis of the films showed that irradiation without gating leads to significant underdosages up to 33%, especially at the edge of the tumour. With gating it is possible to considerably reduce this underdosage down to 9% depending on the trigger threshold. The calculation of the dose volume histograms makes it possible to find a reasonable compromise between the improvement of the dose distribution and the increase of the treatment time.

Artifacts↗

Intensity modulated radiation therapy with multileaf collimators of different leaf widths: a comparison of achievable dose distributions.

PURPOSE: A planning study to analyze the impact of different leaf widths on the achievable dose distributions with intensity modulated radiation therapy (IMRT). METHODS: Five patients (3 intra- and 2 extra-cranial) with projected planning target volume (PTV) sizes smaller than 10 cm by 10 cm were re-planned with four different multileaf collimators (MLC). Two internal collimators with an isocentric leaf width of 4 and 10 mm and two add-on collimators with an isocentric leaf width of 2.75 and were evaluated. The inverse treatment planning system KonRad (Siemens Medical Solutions) was used to create IMRT 'step & shoot' plans. For each patient the same arrangement of beams and the same parameters for the optimization were used for all MLCs. The beamlet size for all treatment plans was chosen to coincide with the leaf width of the respective MLC. To evaluate the treatment plans 3D dose distributions and dose volume histograms were analyzed. As indicators for the quality of the PTV dose distribution the minimum dose, maximum dose and the standard deviation were used. For the organs at risk (OAR) the equivalent uniform dose (EUD) was calculated. To measure the dose coverage of the PTV the volume (V(90)) that received doses higher than 90% of the prescribed dose was calculated where for the conformity the dose conformity index given by Baltas et al. was determined. RESULTS: The MLC with the smallest leaf width yields the best mean value of all five patients for the PTV coverage and for the conformity. For the MLCs with the same leaf width, the add-on MLC leads to superior treatment plans than the internal MLC. This is due to the sharper penumbra of the add-on MLC. The number of IMRT field segments to deliver increased by approximately a factor of two if 2. MLC leafs are used instead of the standard 10 mm leafs. In case of the para-spinal patients the EUD value for the spinal cord is only reduced slightly by using MLCs with leaf widths smaller than 5 mm. For the intra-cranial the EUD value for some organs improved with reduced leaf widths while for some organs the 10 mm MLC leafs give comparable values. CONCLUSION: As expected the MLC with the smallest leaf width always yields the best PTV coverage. Reducing the leaf width from 4 to 2.75 mm results in a slight enhancement of the PTV coverage. With the selected organ parameters no significant improvement for most OAR was found. The disadvantage of the reduction of the leaf width is the increasing number of segments due to the more complex fluence patterns and therefore an increased delivery time.

Equipment Design↗

Inverse planned stereotactic intensity modulated radiotherapy (IMRT) in the palliative treatment of malignant mesothelioma of the pleura: the Heidelberg experience.

Intensity modulated radiation therapy (IMRT) is a new promising treatment technique, which allows a more conformal application of the dose to the tumor volume, as compared to conventional radio-oncological approaches, while protecting the surrounding normal tissue more accurately. This manuscript presents the final results of IMRT in the treatment of unresectable pleural mesothelioma in Heidelberg.

Aged↗

Does electron and proton therapy reduce the risk of radiation induced cancer after spinal irradiation for childhood medulloblastoma? A comparative treatment planning study.

The aim of this treatment planning comparison study was to explore different spinal irradiation techniques with respect to the risk of late side-effects, particularly radiation-induced cancer. The radiotherapy techniques compared were conventional photon therapy, intensity modulated x-ray therapy (IMXT), conventional electron therapy, intensity/energy modulated electron therapy (IMET) and proton therapy (IMPT).CT images for radiotherapy use from five children, median age 8 and diagnosed with medulloblastoma, were selected for this study. Target volumes and organs at risk were defined in 3-D. Treatment plans using conventional photon therapy, IMXT, conventional electron therapy, IMET and IMPT were set up. The probability of normal tissue complication (NTCP) and the risk of cancer induction were calculated using models with parameters-sets taken from published data for the general population; dose data were taken from dose volume histograms (DVH). Similar dose distributions in the targets were achieved with all techniques but the absorbed doses in the organs-at-risk varied significantly between the different techniques. The NTCP models based on available data predicted very low probabilities for side-effects in all cases. However, the effective mean doses outside the target volumes, and thus the predicted risk of cancer induction, varied significantly between the techniques. The highest lifetime risk of secondary cancers was estimated for IMXT (30%). The lowest risk was found with IMPT (4%). The risks associated with conventional photon therapy, electron therapy and IMET were 20%, 21% and 15%, respectively. This model study shows that spinal irradiation of young children with photon and electron techniques results in a substantial risk of radiation-induced secondary cancers. Multiple beam IMXT seems to be associated with a particularly high risk of secondary cancer induction. To minimise this risk, IMPT should be the treatment of choice. If proton therapy is not available, advanced electron therapy may provide a better alternative.

Child↗

Evaluation of salivary gland function after treatment of head-and-neck tumors with intensity-modulated radiotherapy by quantitative pertechnetate scintigraphy.

PURPOSE: To evaluate salivary gland function after inversely planned stereotactic intensity-modulated radiotherapy (IMRT) for tumors of the head-and-neck region using quantitative pertechnetate scintigraphy. METHODS AND MATERIALS: Since January 2000, 18 patients undergoing IMRT for cancer of the head and neck underwent pre- and posttherapeutic scintigraphy to examine salivary gland function. The mean dose to the primary planning target volume was 61.5 Gy (range 50.4-73.2), and the median follow-up was 23 months. In all cases, the parotid glands were directly adjacent to the planning target volume. The treatment planning goal was for at least one parotid gland to receive a mean dose of <26 Gy. Two quantitative parameters (change in maximal uptake and change in the relative excretion rate before and after IMRT) characterizing the change in salivary gland function after radiotherapy were determined. These parameters were compared with respect to the dose thresholds of 26 and 30 Gy for the mean dose. In addition, dose-response curves were calculated. RESULTS: Using IMRT, it was possible in 16 patients to reduce the dose for at least one parotid gland to < or =26 Gy. In 7 patients, protection of both parotid glands was possible. No recurrent disease adjacent to the protected parotid glands was observed. Using the Radiation Therapy Oncology Group/European Organization for the Research and Treatment of Cancer scoring system, only 3 patients had Grade 2 xerostomia. No greater toxicity was seen for the salivary glands. The change in the relative excretion rate was significantly greater, if the parotid glands received a mean dose of > or =26 Gy or > or =30 Gy. For the change in maximal uptake, a statistically significant difference was seen only for the parotid glands and a dose threshold of 30 Gy. For the end point of a reduction in the parotid excretion rate of >50% and 75%, the dose-response curves yielded a dose at 50% complication probability of 34.8 +/- 3.6 and 40.8 +/- 5.3 Gy, respectively. CONCLUSION: Using IMRT, it is possible to protect the parotid glands and reduce the incidence and severity of xerostomia in patients. Doses <26-30 Gy significantly preserve salivary gland function. The results support the hypothesis that application of IMRT does not lead to increased local failure rates.

Adult↗

Intensity modulated radiation therapy with electrons using algorithm based energy/range selection methods.

BACKGROUND AND PURPOSE: In recent years photon intensity modulated radiation therapy (IMRT) has gained attention due to its ability to improve conformity of dose distributions. A potential advantage of electron-IMRT is that the dose fall off in the depth dose curve makes it possible to modulate the dose distribution in the direction of the beam by selecting different electron energies. This paper examines the use of a computer based energy selection in combination with the IMRT technique to optimise the electron dose distribution. MATERIALS AND METHODS: One centimetre square electron beamlets ranging from 2.5 to 50 MeV were pre-calculated in water using Monte Carlo methods. A modified IMRT optimisation tool was then used to find an optimum mix of electron energies and intensities. The main principles used are illustrated in some simple geometries and tested on two clinical cases of post-operated ca. mam. RESULTS: It is clearly illustrated that the energy optimisation procedure lowers the dose to lung and heart and makes the dose in the target more homogeneous. Increasing the energy at steep gradients compensates for lack of target coverage at beam edges and steep gradients. Comparison with a clinically acceptable four segment plan indicates the advantage of the used electron IMRT technique. CONCLUSIONS: Using an intensity optimised mix of computer selected electron energies has the potential to improve electron treatments for mastectomy patients with good target coverage and reduced dose to normal tissue such as lung and heart.

Algorithms↗

Inverse planning of intensity modulated proton therapy.

A common requirement of radiation therapy is that treatment planning for different radiation modalities is devised on the basis of the same treatment planning system (TPS). The present study presents a novel multi-modal TPS with separate modules for the dose calculation, the optimization engine and the graphical user interface, which allows to integrate different treatment modalities. For heavy-charged particles, both most promising techniques, the distal edge tracking (DET) and the 3-dimensional scanning (3D) technique can be optimized. As a first application, the quality of optimized intensity-modulated treatment plans for photons (IMXT) and protons (IMPT) was analyzed in one clinical case on the basis of the achieved physical dose distributions. A comparison of the proton plans with the photon plans showed no significant improvement in terms of target volume dose, however there was an improvement in terms of organs at risk as well as a clear reduction of the total integral dose. For the DET technique, it is possible to create a treatment plan with almost the same quality of the 3D technique, however with a clearly reduced number (factor of 5) of beam spots as well as a reduced optimization time. Due to its modular design, the system can be easily expanded to more sophisticated dose-calculation algorithms or to modeling of biological effects.

Humans↗

Stereotactic intensity-modulated radiation therapy (IMRT) and inverse treatment planning for advanced pleural mesothelioma. Feasibility and initial results.

BACKGROUND AND PURPOSE: Complex-shaped malignant pleural mesotheliomas (MPMs) with challenging volumes are extremely difficult to treat by conventional radiotherapy due to tolerance doses of the surrounding normal tissue. In a feasibility study, we evaluated if inversely planned stereotactic intensity-modulated radiation therapy (IMRT) could be applied in the treatment of MPM. PATIENTS AND METHODS: Eight patients with unresectable lesions were treated after failure of chemotherapy. All patients were positioned using noninvasive patient fixation techniques which can be attached to the applied extracranial stereotactic system. Due to craniocaudal extension of the tumor, it was necessary to develop a special software attached to the inverse planning program KonRad, which can connect two inverse treatment plans and consider the applied dose of the first treatment plan in the area of the matchline of the second treatment plan. RESULTS: Except for one patient, in whom radiotherapy was canceled due to abdominal metastasis, treatment could be completed in all patients and was well tolerated. Median survival after diagnosis was 20 months and after IMRT 6.5 months. Therefore, both the 1-year actuarial overall survival from the start of radiotherapy and the 2-year actuarial overall survival since diagnosis were 28%. IMRT did not result in clinically significant acute side effects. By using the described inverse planning software, over or underdosage in the region of the field matchline could be prevented. Pure treatment time ranged between 10 and 21 min. CONCLUSION: This study showed that IMRT is feasible in advanced unresectable MPM. The presented possibilities of stereotactic IMRT in the treatment of MPM will justify the evaluation of IMRT in early-stage pleural mesothelioma combined with chemotherapy in a study protocol, in order to improve the outcome of these patients. Furthermore, dose escalation should be possible by using IMRT.

Aged↗

Stereotactic intensity modulated radiation therapy and inverse treatment planning for tumors of the head and neck region: clinical implementation of the step and shoot approach and first clinical results.

PURPOSE/OBJECTIVE: The aim of this analysis is to evaluate the feasibility of inverse treatment planning and intensity modulated radiation therapy (IMRT) for head and neck cancer in daily clinical routine. A step and shoot IMRT approach was developed which allows the treatment of large target volumes without the need to use a split beam technique. By using the IMRT approach better protection of different organs at risk in the head and neck region may be achieved and an escalation of the dose in the tumor should be possible. We evaluated the feasibility of the treatment technique and the patient tolerance to the treatment. First clinical results are reported. MATERIALS AND METHODS: Between 1999 and 2002, 48 patients with a carcinoma of the head and neck region were treated with curative intention. All patients were treated in a patient-specific Scotch-Cast mask. Patients who required treatment of the lymph node levels I-VI, were additionally positioned by a vacuum pillow in order to immobilize the upper part of the thorax. For inverse treatment planning, the software module KonRad was used which was integrated into the VIRTUOS planning system. Each treatment plan was verified using quantitative film dosimetry in a head and neck phantom. The step and shoot IMRT technique with a multileaf collimator integrated in a Primus (Siemens) accelerator was used for treatment. For all target volumes the whole target including the lymph nodes were covered completely by the IMRT treatment. RESULTS: The mean total dose for the target volumes of macroscopic disease ranged between 63.0 and 64.1 Gy. The mean total dose of microscopic disease ranged between 55.2 and 60.1 Gy. The mean percentage of planning target volume receiving <90% of the prescribed dose ranged between 3.0 and 11.5%. For the treatment, the median number of beams was seven (range: five to nine). The time to deliver the treatment ranged between 9 and 18 min. The results of the verification revealed a mean deviation between measured and calculated absolute doses for the 48 patients of 0.1+/-1.4%. Including the phantom verification the IMRT treatment of the patients could be started approximately after five working days. The treatment was well tolerated by all patients. The 2-year actuarial overall survival was 92% and the 2-year actuarial local control rate was 93%. According to the Radiation Therapy Oncology Group (RTOG), no higher acute toxicity than Grade 3 was seen. Observation of the late effects revealed only one transient Grade 4 toxicity of the bone and only four patients had a xerostomia higher than Grade 1. CONCLUSION: The use of an inversely-planned and intensity-modulated step and shoot approach is feasible in clinical routine for head and neck tumors. Treatment could be applied as planned and no increased toxicity was found. Compared to other IMRT approaches for the head and neck region the used technique allows the treatment of the primary tumor and the lymph nodes level I-VI with only one intensity modulated treatment volume. The presented technique avoids to match conventional radiotherapy fields and IMRT fields, and therefore, reduce the risk of overdosage or underdosage at the matching line. Compared to conventional treatment techniques IMRT shows advantages in tumor dose and dose at the organs at risk.

Adult↗

Comparison of IMRT optimization based on a pencil beam and a superposition algorithm.

To investigate the role of sophisticated dose calculation methods for treatment planning, we compared conventional pencil beam optimized 6 and 15 MV intensity-modulated treatment plans with optimizations based on the superposition technique. Five lung and five head and neck IMRT cases with spatial resolutions of bixels and dose voxels usually employed in clinical practice were considered for tumor volumes between 15 and 500 cm3. We investigated the systematic error of the pencil beam algorithm and the pencil beam induced error to the optimal solution of bixel weights. For the lung cases, the pencil beam overestimated the mean dose deposited inside the planning target volume (PTV) by about 8%, for small lung tumors even up to 20.6%. In the head and neck cases only a slight overestimation in mean PTV dose of 1.5% was observed. The optimization with the superposition method substantially improved the dose coverage of the considered radiation targets. Additionally, for the head and neck cases, the brainstem was significantly spared by about 4% mean PTV dose through the use of the superposition technique. Our studies showed that, in target regions with intricate tissue inhomogeneities, superposition or Monte Carlo techniques have to be used for the optimization and the final dose calculation of intensity-modulated treatment plans.

Algorithms↗

From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning.

Optimization algorithms in inverse radiotherapy planning need information about the desired dose distribution. Usually the planner defines physical dose constraints for each structure of the treatment plan, either in form of minimum and maximum doses or as dose-volume constraints. The concept of equivalent uniform dose (EUD) was designed to describe dose distributions with a higher clinical relevance. In this paper, we present a method to consider the EUD as an optimization constraint by using the method of projections onto convex sets (POCS). In each iteration of the optimization loop, for the actual dose distribution of an organ that violates an EUD constraint a new dose distribution is calculated that satisfies the EUD constraint, leading to voxel-based physical dose constraints. The new dose distribution is found by projecting the current one onto the convex set of all dose distributions fulfilling the EUD constraint. The algorithm is easy to integrate into existing inverse planning systems, and it allows the planner to choose between physical and EUD constraints separately for each structure. A clinical case of a head and neck tumor is optimized using three different sets of constraints: physical constraints for all structures, physical constraints for the target and EUD constraints for the organs at risk, and EUD constraints for all structures. The results show that the POCS method converges stable and given EUD constraints are reached closely.

Algorithms↗

IMRT-application with an add-on MMLC.

In order to provide automatic IMRT dose delivery with an add-on MMLC a technical integration of a MMLC system with a linear accelerator was realized. The principle of this integration and the changes and enhancements of the existing hard- and software are briefly described. The system was tested by the automatic delivery of an IMRT plan designed for a head and neck phantom. A verification of dose delivery was performed with film dosimetry. The plan consisting of 78 "step and shoot" segments could be delivered within 17 minutes. A high spatial accuracy of the fluence pattern at the isocentre was reached by a resolution of 2.75x2.75 mm(2). The measured dose profiles were within 3% of the maximum dose of the calculated profiles.

Humans↗

Inverse treatment planning and stereotactic intensity-modulated radiation therapy (IMRT) of the tumor and lymph node levels for nasopharyngeal carcinomas. Description of treatment technique, plan comparison, and case study.

PURPOSE: Inverse treatment planning and intensity-modulated radiation therapy (IMRT) promise advantages in the treatment of tumors of the head and neck region. Currently published studies use IMRT only in the treatment of the primary tumor. In these studies, the lymph nodes of the neck were treated using conventional techniques. The feasibility of an IMRT technique which allows treatment of the complete target volume, including the primary tumor and lymph nodes, without a beam split is described. PATIENT AND METHOD: For inverse treatment planning, the KonRad planning system was used. The primary as well as the secondary PTV (bilateral lymph node levels) were treated with one intensity-modulated primary plan. To increase the dose in the primary PTV and suspicious lymph nodes, an intensity-modulated boost plan was performed. The "step and shoot" IMRT technique was used. A plan comparison between the described IMRT approach and an IMRT approach using a split-beam technique was performed focusing on the treatment time. A patient with a carcinoma of the nasopharynx was treated with curative intent by a combined radiochemotherapy. RESULTS: The median total dose to the primary PTV was 70 Gy, to suspicious lymph nodes > or = 66.0 Gy, and to the secondary PTV 52 Gy. The defined maximum doses to the organs at risk were not exceeded, and the median dose to the protected parotid gland amounted to 21 Gy. Comparison of the treatment time between both IMRT approaches revealed only a slightly shorter treatment time (1-3 min) for the split-beam IMRT technique without considering the remaining conventional treatment parts of the split-beam IMRT technique. The patient achieved a complete response, and 18 months after treatment no signs of recurrent disease are visible. CONCLUSIONS: IMRT allows the treatment of the target volumes with high doses combined with an excellent sparing of the organs at risk. The IMRT approach presented here makes the treatment of the whole target volume with a single-beam arrangement feasible and does not increase the treatment time compared to a split-beam IMRT technique. Treatment time was comparable to a conventional three-field technique combined with electrons. This IMRT technique can prevent over- or underdosage at field matchlines in the head and neck region and, moreover, is able to spare parotid glands and therefore better avoid xerostomia compared to conventional techniques.

Algorithms↗