PubMed Health⌕ Search

Biomedical subjects

Simon J Hickman

Publications and source records attributed to Simon J Hickman.

4 recordsLinked to original sources

Application of a B-spline active surface technique to the measurement of cervical cord volume in multiple sclerosis from three-dimensional MR images.

PURPOSE: To evaluate the ability of a B-spline active surface technique to detect cervical spinal cord atrophy due to multiple sclerosis (MS) compared with intensity-based contouring. MATERIALS AND METHODS: In a previously reported study, the cervical spinal cords of 28 MS patients and 13 age-matched controls were imaged with a volume-acquired inversion-prepared fast spoiled gradient echo sequence at baseline and after one year. The images were reanalyzed using the B-spline technique and the results compared with the results obtained in the original report using intensity-based contouring. RESULTS: The mean cervical spinal cord volume determined by the active surface programme was 6487 mm(3) in 28 patients compared with 7117 mm(3) in controls (P = 0.002, corrected for age and gender). The patients' cervical spinal cord volumes were associated with expanded disability status scale scores (parameter estimate = -1.21 x 10(-3), r(2) = 0.39, P = 0.001). The patients' cervical spinal cord volumes did not decrease significantly over one year, unlike the mean cervical spinal cord areas at C2/3 calculated using intensity-based contouring. CONCLUSION: The active surface technique can detect cervical spinal cord atrophy due to MS, which has functional significance. However, this methodology is less sensitive at detecting small serial changes compared with the previously reported method.

Atrophy↗

Application of the new McDonald criteria to patients with clinically isolated syndromes suggestive of multiple sclerosis.

Traditionally, multiple sclerosis (MS) has been diagnosed on the basis of clinical evidence of dissemination in time and space. Previously, it could not be diagnosed in patients with single clinical episodes of demyelination known as clinically isolated syndromes. New diagnostic criteria from the International Panel of McDonald and colleagues incorporate MRI evidence of dissemination in time and space to allow a diagnosis of MS in patients with clinically isolated syndromes. From clinical and MRI examinations performed prospectively at baseline, 3 months, 1 year, and 3 years of follow-up, the frequency of developing MS was ascertained by the application of both the new McDonald criteria and the Poser criteria for clinically definite MS. The specificity, sensitivity, positive and negative predictive value, and accuracy of the new criteria for the development of clinically definite MS were assessed. At 3 months, 20 of 95 (21%) patients had MS with the McDonald criteria, whereas only 7 of 95 (7%) had developed clinically definite MS. After 1 year, the corresponding figures were 38 of 79 (48%) and 16 of 79 (20%), and after 3 years, they were 29 of 50 (58%) and 19 of 50 (38%). The development of MS with the new MRI criteria after 1 year had a high sensitivity (83%), specificity (83%), positive predicative value (75%), negative predictive value (89%), and accuracy (83%) for clinically definite MS at 3 years. Use of the new McDonald criteria more than doubled the rate of diagnosis of MS within a year of presentation with a clinically isolated syndrome. The high specificity, positive predictive value, and accuracy of the new criteria for clinically definite MS support their clinical relevance.

Adolescent↗

ADC mapping of the human optic nerve: increased resolution, coverage, and reliability with CSF-suppressed ZOOM-EPI.

The mean apparent diffusion coefficient (ADC) of the human optic nerve (ON) has been quantified in vivo, and mean ADC maps are shown along the complete length of the nerve from the globe to the optic chiasm. The mean ADC, over the whole nerve, is shown to be 1058 x 10(-6) mm(2) s(-1) (standard deviation (SD), over nine 3-mm slices, 101x10(-6) mm(2) s(-1); range (833-1178)x10(-6) mm(2) s(-1)). The robustness of the method relies on acquisition of high-resolution coronal images of the ON using the ZOOM-EPI technique, which makes use of a shortened echo train length for increased resolution with decreased susceptibility-induced distortions. Suppression of the cerebrospinal fluid (CSF) and fat signals from tissues that surround the ON also helps successful identification and delineation of the nerve. Averaging of magnitude images is used to compensate for the inherently low signal-to-noise ratio (SNR) of the acquired images; the effects of the Rayleigh distributed noise in such images are allowed for during ADC calculations.

Cerebrospinal Fluid↗

Investigating cervical spinal cord structure using axial diffusion tensor imaging.

This study describes a new technique for Diffusion Tensor Imaging (DTI) that acquires axial (transverse) images of the cervical spinal cord. The DTI images depict axonal fiber orientation, enable quantification of diffusion characteristics along the spinal cord, and have the potential to demonstrate the connectivity of cord white matter tracts. Because of the high sensitivity to motion of diffusion-weighted magnetic resonance imaging and the small size of the spinal cord, a fast imaging method with high in-plane resolution was developed. Images were acquired with a single-shot EPI technique, named ZOOM-EPI (zonally magnified oblique multislice echo planar imaging), which selects localized areas and reduces artefacts caused by susceptibility changes between soft tissue and the adjacent vertebrae. Cardiac gating was used to reduce pulsatile flow artefacts from the surrounding cerebrospinal fluid. Voxel resolution was 1.25 x 1.25 mm(2) in-plane with 5-mm slice thickness. Both the mean diffusivity (MD) and the fractional anisotropy (FA) indices of the cervical spinal cord were measured. The FA index demonstrated high anisotropy of the spinal cord with an average value of 0.61 +/- 0.05 (highest value of 0.66 +/- 0.03 at C3), comparable to white matter tracts in the brain. The diffusivity components parallel and orthogonal to the longitudinal axes of the cord were lambda( parallel) = (1648 +/- 123) x 10(-6) mm(2)s(-1) and lambda( perpendicular) = (570 +/- 47) x 10(-6) mm(2) s(-1), respectively. The high axial resolution allowed preliminary evaluation of fiber connectivity using the fast-marching tractography algorithm, which generated traces of fiber paths consistent with the well-known cord anatomy.

Algorithms↗