PubMed Health⌕ Search

Biomedical subjects

Simon K Warfield

Publications and source records attributed to Simon K Warfield.

At least 19 recordsLinked to original sources

Reduction in cerebellar volumes in preterm infants: relationship to white matter injury and neurodevelopment at two years of age.

A substantial number of prematurely born infants will experience later neurodevelopmental challenges. Abnormal development of the cerebellum may be related to some of the impairments exhibited by preterm children. To test the hypothesis that cerebellar development is structurally impaired in preterm infants and associated with adverse outcomes, we studied 83 preterm infants and 13 term controls using volumetric magnetic resonance imaging techniques to obtain cerebellar volumes (CV) at term corrected and subsequent neurodevelopmental assessment at 2 y of age. The preterm group had smaller mean CV at term compared with the term control infants [mean (SD) CV, 22.0 (5.0) versus 23.5 (5.0) cc; mean difference (95% confidence interval), 1.5 (-1.5, 4.4)] although this did not reach statistical significance. Within the preterm group, there was evidence of a reduction in CV related to the presence of white matter injury (WMI) after adjusting for intracranial volume (ICV) [WMI grade 1 versus grade 2: mean (SD) CV, 23.6 (5.0) versus 21.6 (4.5); p = 0.01; WMI grade 1 versus grade 3 and 4: 23.6 (5.0) versus 20.8 (5.6); p = 0.07]. Within the preterm infants, there was no apparent relationship between CV at term and gestational age at birth after adjusting for ICV. At 2 y of age, CV showed a weak correlation with cognitive and motor development, although this was principally mediated by WMI. In conclusion, we found no evidence for a primary impairment in cerebellar development in relation to prematurity, although there was evidence for a secondary effect of cerebral WMI on cerebellar development independent of immaturity.

Aging↗

Patient-specific model of brain deformation: application to medical image registration.

This contribution presents finite element computation of the deformation field within the brain during craniotomy-induced brain shift. The results were used to illustrate the capabilities of non-linear (i.e. accounting for both geometric and material non-linearities) finite element analysis in non-rigid registration of pre- and intra-operative magnetic resonance images of the brain. We used patient-specific hexahedron-dominant finite element mesh, together with realistic material properties for the brain tissue and appropriate contact conditions at boundaries. The model was loaded by the enforced motion of nodes (i.e. through prescribed motion of a boundary) at the brain surface in the craniotomy area. We suggest using explicit time-integration scheme for discretised equations of motion, as the computational times are much shorter and accuracy, for practical purposes, the same as in the case of implicit integration schemes. Application of the computed deformation field to register (i.e. align) the pre-operative images with the intra-operative ones indicated that the model very accurately predicts the displacements of the tumour and the lateral ventricles even for limited information about the brain surface deformation. The prediction accuracy improves when information about deformation of not only exposed (during craniotomy) but also unexposed parts of the brain surface is used when prescribing loading. However, it appears that the accuracy achieved using information only about the deformation of the exposed surface, that can be determined without intra-operative imaging, is acceptable. The presented results show that non-linear biomechanical models can complement medical image processing techniques when conducting non-rigid registration. Important advantage of such models over the previously used linear ones is that they do not require unrealistic assumptions that brain deformations are infinitesimally small and brain stress-strain relationship is linear.

Brain↗

Accrual of MRI white matter abnormalities in elderly with normal and impaired mobility.

White matter signal abnormality (WMSA) is often present in the MRIs of older persons with mobility impairment. We examined the relationship between impaired mobility and the progressive accrual of WMSA. Mobility was assessed with the Short Physical Performance Battery (SPPB) and quantitative measures of gait and balance. Fourteen subjects had baseline and follow-up MRI scans performed 20 months apart. WMSA was detected and quantified using automated computer algorithms. In the control subjects, WMSA volume increased by 0.02+/-0.05% ICCV (percent intracranial cavity volume)/year while the WMSA of mobility impaired subjects increased five-times faster (0.10+/-0.10 ICCV/year, p=0.03). WMSA volume was related to some of the mobility measures and was sensitive to change which was not true of the other MRI variables. The study demonstrates the sensitivity of longitudinal automated volumetric analysis of WMSA to differentiate differences in the accrual rate of WMSA in groups selected on the basis of mobility. Based on these results, we propose that a subset of subjects with mobility impairment have accelerated, disease related WMSA accrual, thus explaining the rapid progression of mobility impairment in some older persons without apparent cause. This study demonstrates that quantitative MRI and performance measures can provide valuable insight into the rate of progression and pathophysiologic abnormalities underlying mobility impairment.

Aged↗

Non-rigid registration of a 3D ultrasound and a MR image data set of the female pelvic floor using a biomechanical model.

BACKGROUND: The visual combination of different modalities is essential for many medical imaging applications in the field of Computer-Assisted medical Diagnosis (CAD) to enhance the clinical information content. Clinically, incontinence is a diagnosis with high clinical prevalence and morbidity rate. The search for a method to identify risk patients and to control the success of operations is still a challenging task. The conjunction of magnetic resonance (MR) and 3D ultrasound (US) image data sets could lead to a new clinical visual representation of the morphology as we show with corresponding data sets of the female anal canal with this paper. METHODS: We present a feasibility study for a non-rigid registration technique based on a biomechanical model for MR and US image data sets of the female anal canal as a base for a new innovative clinical visual representation. RESULTS: It is shown in this case study that the internal and external sphincter region could be registered elastically and the registration partially corrects the compression induced by the ultrasound transducer, so the MR data set showing the native anatomy is used as a frame for the US data set showing the same region with higher resolution but distorted by the transducer CONCLUSION: The morphology is of special interest in the assessment of anal incontinence and the non-rigid registration of normal clinical MR and US image data sets is a new field of the adaptation of this method incorporating the advantages of both technologies.

Algorithms↗

Automated atlas-based clustering of white matter fiber tracts from DTMRI.

A new framework is presented for clustering fiber tracts into anatomically known bundles. This work is motivated by medical applications in which variation analysis of known bundles of fiber tracts in the human brain is desired. To include the anatomical knowledge in the clustering, we invoke an atlas of fiber tracts, labeled by the number of bundles of interest. In this work, we construct such an atlas and use it to cluster all fiber tracts in the white matter. To build the atlas, we start with a set of labeled ROIs specified by an expert and extract the fiber tracts initiating from each ROI. Affine registration is used to project the extracted fiber tracts of each subject to the atlas, whereas their B-spline representation is used to efficiently compare them to the fiber tracts in the atlas and assign cluster labels. Expert visual inspection of the result confirms that the proposed method is very promising and efficient in clustering of the known bundles of fiber tracts.

Algorithms↗

Combining classifiers using their receiver operating characteristics and maximum likelihood estimation.

In any medical domain, it is common to have more than one test (classifier) to diagnose a disease. In image analysis, for example, there is often more than one reader or more than one algorithm applied to a certain data set. Combining of classifiers is often helpful, but determining the way in which classifiers should be combined is not trivial. Standard strategies are based on learning classifier combination functions from data. We describe a simple strategy to combine results from classifiers that have not been applied to a common data set, and therefore can not undergo this type of joint training. The strategy, which assumes conditional independence of classifiers, is based on the calculation of a combined Receiver Operating Characteristic (ROC) curve, using maximum likelihood analysis to determine a combination rule for each ROC operating point. We offer some insights into the use of ROC analysis in the field of medical imaging.

Artificial Intelligence↗

Spectral clustering algorithms for ultrasound image segmentation.

Image segmentation algorithms derived from spectral clustering analysis rely on the eigenvectors of the Laplacian of a weighted graph obtained from the image. The NCut criterion was previously used for image segmentation in supervised manner. We derive a new strategy for unsupervised image segmentation. This article describes an initial investigation to determine the suitability of such segmentation techniques for ultrasound images. The extension of the NCut technique to the unsupervised clustering is first described. The novel segmentation algorithm is then performed on simulated ultrasound images. Tests are also performed on abdominal and fetal images with the segmentation results compared to manual segmentation. Comparisons with the classical NCut algorithm are also presented. Finally, segmentation results on other types of medical images are shown.

Algorithms↗

Hybrid formulation of the model-based non-rigid registration problem to improve accuracy and robustness.

We present a new algorithm to register 3D pre-operative Magnetic Resonance (MR) images with intra-operative MR images of the brain. This algorithm relies on a robust estimation of the deformation from a sparse set of measured displacements. We propose a new framework to compute iteratively the displacement field starting from an approximation formulation (minimizing the sum of a regularization term and a data error term) and converging toward an interpolation formulation (least square minimization of the data error term). The robustness of the algorithm is achieved through the introduction of an outliers rejection step in this gradual registration process. We ensure the validity of the deformation by the use of a biomechanical model of the brain specific to the patient, discretized with the finite element method. The algorithm has been tested on six cases of brain tumor resection, presenting a brain shift up to 13 mm.

Algorithms↗

Brain shift computation using a fully nonlinear biomechanical model.

In the present study, fully nonlinear (i.e. accounting for both geometric and material nonlinearities) patient specific finite element brain model was applied to predict deformation field within the brain during the craniotomy-induced brain shift. Deformation of brain surface was used as displacement boundary conditions. Application of the computed deformation field to align (i.e. register) the preoperative images with the intraoperative ones indicated that the model very accurately predicts the displacements of gravity centers of the lateral ventricles and tumor even for very limited information about the brain surface deformation. These results are sufficient to suggest that nonlinear biomechanical models can be regarded as one possible way of complementing medical image processing techniques when conducting nonrigid registration. Important advantage of such models over the linear ones is that they do not require unrealistic assumptions that brain deformations are infinitesimally small and brain tissue stress-strain relationship is linear.

Biomechanical Phenomena↗

Three-dimensional assessment of MR imaging-guided percutaneous cryotherapy using multi-performer repeated segmentations: the value of supervised learning.

RATIONALE AND OBJECTIVES: Accurate and reproducible segmentations of two-dimensional images are an important prerequisite for assessing tumor ablations three dimensionally (3D). We evaluated whether supervised learning methods would improve multiperformer repeated segmentations of magnetic resonance images (MRI) obtained before and after MRI-guided cryotherapy of renal cell carcinoma. MATERIALS AND METHODS: Three medical students independently performed five manual segmentations of a biopsy-proven renal cell carcinoma that was treated with percutaneous MRI-guided cryotherapy. Using pretreatment (T2-weighted fast recovery fast spin echo [FRFSE]) and posttreatment (T1-weighted, fat-suppressed, dynamically enhanced) MRIs, regions of tumor cryonecrosis were segmented. The same tasks were repeated after an experienced abdominal radiologist provided supervised learning. Segmentation sensitivity was compared with an estimated 3D-ground truth via voxel counts for regions of tumor, both before and after treatment, and for the regions of cryonecrosis. The sensitivity of each repeated segmentation was compared against the estimated ground truth using sensitivity, overlap index, and volume (mL). RESULTS: Supervised learning significantly improved posttreatment segmentation sensitivity (P = .03). With supervised learning, the ranges of the performance metrics over the segmentation performers were: pretreated tumor, sensitivity 0.902-0.999, overlap index 0.935-0.961, and volume 19.15-23.71 mL; posttreated tumor, sensitivity 0.923-0.991, overlap index 0.952-0.981, and volume 20.67-22.70 mL; in the ablation zone, sensitivity 0.938-0.969, overlap index 0.940-0.962, and volume 31.79-32.36 mL. CONCLUSIONS: Supervised learning improved multiperformer repeated segmentations of MRIs obtained before and after MRI-guided percutaneous cryotherapy of renal cell carcinoma. These methods may prove useful in aiding the 3D assessment of percutaneous tumor ablations.

Aged↗

Efficient multi-modal dense field non-rigid registration: alignment of histological and section images.

We describe a new algorithm for non-rigid registration capable of estimating a constrained dense displacement field from multi-modal image data. We applied this algorithm to capture non-rigid deformation between digital images of histological slides and digital flat-bed scanned images of cryotomed sections of the larynx, and carried out validation experiments to measure the effectiveness of the algorithm. The implementation was carried out by extending the open-source Insight ToolKit software. In diagnostic imaging of cancer of the larynx, imaging modalities sensitive to both anatomy (such as MRI and CT) and function (PET) are valuable. However, these modalities differ in their capability to discriminate the margins of tumor. Gold standard tumor margins can be obtained from histological images from cryotomed sections of the larynx. Unfortunately, the process of freezing, fixation, cryotoming and staining the tissue to create histological images introduces non-rigid deformations and significant contrast changes. We demonstrate that the non-rigid registration algorithm we present is able to capture these deformations and the algorithm allows us to align histological images with scanned images of the larynx. Our non-rigid registration algorithm constructs a deformation field to warp one image onto another. The algorithm measures image similarity using a mutual information similarity criterion, and avoids spurious deformations due to noise by constraining the estimated deformation field with a linear elastic regularization term. The finite element method is used to represent the deformation field, and our implementation enables us to assign inhomogeneous material characteristics so that hard regions resist internal deformation whereas soft regions are more pliant. A gradient descent optimization strategy is used and this has enabled rapid and accurate convergence to the desired estimate of the deformation field. A further acceleration in speed without cost of accuracy is achieved by using an adaptive mesh refinement strategy.

Algorithms↗

An EM algorithm for shape classification based on level sets.

In this paper, we propose an expectation-maximization (EM) approach to separate a shape database into different shape classes, while simultaneously estimating the shape contours that best exemplify each of the different shape classes. We begin our formulation by employing the level set function as the shape descriptor. Next, for each shape class we assume that there exists an unknown underlying level set function whose zero level set describes the contour that best represents the shapes within that shape class. The level set function for each example shape in the database is modeled as a noisy measurement of the appropriate shape class's unknown underlying level set function. Based on this measurement model and the judicious introduction of the class labels as the hidden data, our EM formulation calculates the labels for shape classification and estimates the shape contours that best typify the different shape classes. This resulting iterative algorithm is computationally efficient, simple, and accurate. We demonstrate the utility and performance of this algorithm by applying it to two medical applications.

Algorithms↗

Robust nonrigid registration to capture brain shift from intraoperative MRI.

We present a new algorithm to register 3-D preoperative magnetic resonance (MR) images to intraoperative MR images of the brain which have undergone brain shift. This algorithm relies on a robust estimation of the deformation from a sparse noisy set of measured displacements. We propose a new framework to compute the displacement field in an iterative process, allowing the solution to gradually move from an approximation formulation (minimizing the sum of a regularization term and a data error term) to an interpolation formulation (least square minimization of the data error term). An outlier rejection step is introduced in this gradual registration process using a weighted least trimmed squares approach, aiming at improving the robustness of the algorithm. We use a patient-specific model discretized with the finite element method in order to ensure a realistic mechanical behavior of the brain tissue. To meet the clinical time constraint, we parallelized the slowest step of the algorithm so that we can perform a full 3-D image registration in 35 s (including the image update time) on a heterogeneous cluster of 15 personal computers. The algorithm has been tested on six cases of brain tumor resection, presenting a brain shift of up to 14 mm. The results show a good ability to recover large displacements, and a limited decrease of accuracy near the tumor resection cavity.

Algorithms↗

Realistic simulation of the 3-D growth of brain tumors in MR images coupling diffusion with biomechanical deformation.

We propose a new model to simulate the three-dimensional (3-D) growth of glioblastomas multiforma (GBMs), the most aggressive glial tumors. The GBM speed of growth depends on the invaded tissue: faster in white than in gray matter, it is stopped by the dura or the ventricles. These different structures are introduced into the model using an atlas matching technique. The atlas includes both the segmentations of anatomical structures and diffusion information in white matter fibers. We use the finite element method (FEM) to simulate the invasion of the GBM in the brain parenchyma and its mechanical interaction with the invaded structures (mass effect). Depending on the considered tissue, the former effect is modeled with a reaction-diffusion or a Gompertz equation, while the latter is based on a linear elastic brain constitutive equation. In addition, we propose a new coupling equation taking into account the mechanical influence of the tumor cells on the invaded tissues. The tumor growth simulation is assessed by comparing the in-silico GBM growth with the real growth observed on two magnetic resonance images (MRIs) of a patient acquired with 6 mo difference. Results show the feasibility of this new conceptual approach and justifies its further evaluation.

Algorithms↗

Reproducibility of functional MR imaging: preliminary results of prospective multi-institutional study performed by Biomedical Informatics Research Network.

PURPOSE: To prospectively investigate the factors--including subject, brain hemisphere, study site, field strength, imaging unit vendor, imaging run, and examination visit--affecting the reproducibility of functional magnetic resonance (MR) imaging activations based on a repeated sensory-motor (SM) task. MATERIALS AND METHODS: The institutional review boards of all participating sites approved this HIPAA-compliant study. All subjects gave informed consent. Functional MR imaging data were repeatedly acquired from five healthy men aged 20-29 years who performed the same SM task at 10 sites. Five 1.5-T MR imaging units, four 3.0-T units, and one 4.0-T unit were used. The subjects performed bilateral finger tapping on button boxes with a 3-Hz audio cue and a reversing checkerboard. In a block design, 15-second epochs of alternating baseline and tasks yielded 85 acquisitions per run. Functional MR images were acquired with block-design echo-planar or spiral gradient-echo sequences. Brain activation maps standardized in a unit-sphere for the left and right hemispheres of each subject were constructed. Areas under the receiver operating characteristic curve, intraclass correlation coefficients, multiple regression analysis, and paired Student t tests were used for statistical analyses. RESULTS: Significant factors were subject (P < .005), k-space (P < .005), and field strength (P = .02) for sensitivity and subject (P = .03) and k-space (P = .05) for specificity. At 1.5-T MR imaging, mean sensitivities ranged from 7% to 32% and mean specificities were higher than 99%. At 3.0 T, mean sensitivities and specificities ranged from 42% to 85% and from 96% to 99%, respectively. At 4.0 T, mean sensitivities and specificities ranged from 41% to 73% and from 95% to 99%, respectively. Mean areas under the receiver operating characteristic curve (+/- their standard errors) were 0.77 +/- 0.05 at 1.5 T, 0.90 +/- 0.09 at 3.0 T, and 0.95 +/- 0.02 at 4.0 T, with significant differences between the 1.5- and 3.0-T examinations and between the 1.5- and 4.0-T examinations (P < .01 for both comparisons). Intraclass correlation coefficients ranged from 0.49 to 0.71. CONCLUSION: MR imaging at 3.0- and 4.0-T yielded higher reproducibility across sites and significantly better results than 1.5-T imaging. The effects of subject, k-space, and field strength on examination reproducibility were significant.

Adult↗

An in vivo MRI study of prefrontal cortical complexity in first-episode psychosis.

OBJECTIVE: The purpose of this study was to investigate abnormalities in the surface complexity of the prefrontal cortex and in the hemispheric asymmetry of cortical complexity in first-episode patients with schizophrenia. METHOD: An estimate of the surface complexity of the prefrontal cortex was derived from the number of voxels along the boundary between gray matter and CSF. Magnetic resonance imaging scans were acquired from patients with a first episode of schizophrenia (N=17), patients with a first episode of affective psychosis (N=17), and normal comparison subjects (N=17), age-matched within a narrow age range (18-29 years). This study group was the focus of a previous study that showed lower prefrontal cortical volume in patients with schizophrenia. RESULTS: Prefrontal cortical complexity was not significantly different among the groups. However, the schizophrenia patients differed significantly from the normal comparison subjects in asymmetry, with the schizophrenia patients showing less left-greater-than-right asymmetry in cortical complexity than the comparison subjects. CONCLUSIONS: An abnormal pattern of asymmetry in the prefrontal cortex of first-episode patients with schizophrenia provides evidence for a neurodevelopmental mechanism in the etiology of schizophrenia.

Adolescent↗

Talairach-based parcellation of neonatal brain magnetic resonance imaging data: validation of a new approach.

BACKGROUND AND PURPOSE: Talairach-based parcellation (TP) of human brain magnetic resonance imaging (MRI) data has been used increasingly in clinical research to make regional measurements of brain structures in vivo. Recently, TP has been applied to pediatric research to elucidate the changes in regional brain volumes related to several neurological disorders. However, all freely available tools have been designed to parcellate adult brain MRI data. Parcellation of neonatal MRI data is very challenging owing to the lack of strong signal contrast, variability in signal intensity within tissues, and the small size and thus difficulty in identifying small structures used as landmarks for TP. Hence the authors designed and validated a new interactive tool to parcellate brain MRI data from newborns and young infants. METHODS: The authors' tool was developed as part of a postprocessing pipeline, which includes registration of multichannel MR images, segmentation, and parcellation of the segmented data. The tool employs user-friendly interactive software to visualize and assign the anatomic landmarks required for parcellation, after which the planes and parcels are generated automatically by the algorithm. The authors then performed 3 sets of validation experiments to test the precision and reliability of their tool. RESULTS: Validation experiments of intra-and interrater reliability on data obtained from newborn and 1-year-old children showed a very high sensitivity of >95% and specificity >99.9%. The authors also showed that rotating and reformatting the original MRI data results in a statistically significant difference in parcel volumes, demonstrating the importance of using a tool such as theirs that does not require realignment of the data prior to parcellation. CONCLUSIONS: To the authors' knowledge, the presented approach is the first TP method that has been developed and validated specifically for neonatal brain MRI data. Their approach would also be valuable for the analysis of brain MRI data from older children and adults.

Brain↗

Diffusion tensor magnetic resonance imaging in multiple sclerosis.

Multiple sclerosis (MS), a demyelinating disease, occurs principally in the white matter (WM) of the central nervous system. Conventional magnetic resonance imaging (MRI) is sensitive to some, but not all, brain changes associated with MS. Diffusion-weighted imaging (DWI) provides information about water diffusion in tissue and diffusion tensor MRI (DT-MRI) about fiber direction, allowing for the identification of WM abnormalities that are not apparent on conventional MRI images. These techniques can quantitatively characterize the local microstructure of tissues. MS-associated disease processes lead to regions characterized by an increased amount of water diffusion and a decrease in the anisotropy of diffusion direction. These changes have been found to produce different patterns in MS patients presenting different courses of the disease. Changes in water diffusion may allow examination of the type, appearance, enhancement, and location of lesions not readily visible by other means. Ongoing studies of MS are integrating conventional MRI and DT-MRI measures with connectivity-based regional assessment, aiming to provide a better understanding of the nature and the location of WM lesions. This integration and the development of novel image-processing and visualization techniques may improve the understanding of WM architecture and its disruption in MS. This article presents a brief history of DWI, its basic principles and applications in the study of MS, a review of the properties and applications of DT-MRI, and their use in the study of MS. In addition, this article illustrates the methodology for the analysis of DT-MRI in ongoing studies of MS.

Anisotropy↗