Protein-losing enteropathy in association with constrictive pericarditis.

Although acute pericarditis is a common and usual benign disorder, sometimes evolution to constrictive pericarditis may occur. We present a case of constrictive pericarditis late after coronary bypass grafting, complicated by right sided heart failure. Edema formation was aggravated due to protein-losing enteropathy, resulting in hypoalbuminemia. Imaging of constrictive pericarditis was done by ultrasound as well as simultaneous pressure recording of the right and left ventricle. Imaging of intestinal protein loss was possible using intravenous Technetium-99m-labelled human serum albumin.

Aged↗

Balloon sizing and transcatheter closure of acute atrial septal defects guided by magnetic resonance fluoroscopy: assessment and validation in a large animal model.

PURPOSE: To quantitatively assess atrial septal defects (ASDs) with small shunts using MRI followed by transcatheter closure monitored by MR fluoroscopy. MATERIALS AND METHODS: Acute ASDs were created in 14 pigs under x-ray fluoroscopy. Six animals were studied in order to select MR-compatible delivery systems and imaging strategies. ASDs in eight animals were examined with balloon sizing under MR fluoroscopy, flow measurements, and contrast media injections, after which transcatheter closure was performed under MR fluoroscopy. The delivery system was assembled from commercially available materials. RESULTS: The ratio of pulmonary to systemic flow (Qp/Qs) was reduced from 1.23 +/- 0.15 before ASD closure to 1.07 +/- 0.11 after ASD closure (P < 0.001). In two out of eight animals Qp/Qs was close to 1.0 before closure despite the presence of defects >15 mm. The ASDs were measurable with MR balloon sizing in all of the animals. Balloon sizing was identical with MR (16.9 +/- 2.3 mm) and x-ray fluoroscopy (17.1 +/- 1.3 mm). The in-house-assembled delivery system allowed successful placement of closure devices under MR guidance. CONCLUSION: Assessment and closure of small shunts with MR fluoroscopy is feasible. A barrier to the rapid implementation of transcatheter closure in patients is uncertainty about the MR safety of guidewires and device delivery systems.

Acute Disease↗

Long-term oral treatment with nicorandil prevents the progression of left ventricular hypertrophy and preserves viability.

Left ventricular (LV) hypertrophy and myocardial infarction play important roles in the progressive LV dysfunction. We hypothesized that the potassium-channel opener and nitrate-like vasodilator nicorandil prevents the development of LV hypertrophy and preserves myocardial viability. Twenty-four rats were subjected to aortic stenosis for 8 weeks to produce LV hypertrophy and assigned to non-treated and nicorandil-treated (3 mg/kg/d) groups. A third group (n = 12) without stenosis or treatment served as control. All 36 animals were subjected to reperfused infarction by 25-minute occlusion of the left coronary artery followed by 3 hours of reperfusion. Spin-echo magnetic resonance (MR) images were acquired to measure infarction size, LV mass, volumes, ejection fraction, and wall thickness. A necrosis-specific contrast agent, Gadophrin-3, was used to delineate necrotic myocardium. Aortic and LV pressures were measured invasively. At postmortem, LV mass and infarction size were determined and compared with MR findings. Nicorandil prevented the development of LV hypertrophy. Infarction size of nicorandil-treated animals was similar to control animals. Non-treated animals with aortic banding had higher LV mass (P < 0.001), lower ejection fraction (P = 0.006), and larger infarction size (P < 0.001) than treated and control animals. MR and postmortem data showed close agreement. Nicorandil therapy prevented the development of cardiac hypertrophy and protected myocardium against ischemia.

Administration, Oral↗

Accentuation of high susceptibility of hypertrophied myocardium to ischemia: complementary assessment of Gadophrin-enhancement and left ventricular function with MRI.

The aim of the study was to compare infarction size and left ventricular (LV) function in normal and hypertrophied hearts after brief ischemia using Gadophrin-enhancement and functional assessment by MRI. Rats (n = 20) were assigned to aortic banding to induce LV hypertrophy or control. Eight weeks later, rats were subjected to 25 min of regional myocardial ischemia followed by 3 hr of reperfusion. The necrosis-specific agent Gadophrin-3 was injected to delineate infarcted myocardium on MRI. Effects of aortic banding and ischemia on LV mass and function were determined. At postmortem, areas at risk and infarction were measured. Close correlation was found between LV mass measured with MRI and at postmortem (r = 0.98). LV mass measured with MRI was significantly greater (0.81 +/- 0.02 g) in animals with aortic banding compared to control (0.62 +/- 0.02 g; P < 0.001). Infarction size was larger in hypertrophied hearts (19.0 +/- 1.4% / 18.3 +/- 1.5%) than in control (9.8 +/- 1.7% / 9.2 +/- 2.0%) on Gadophrin-enhanced MRI and at postmortem, respectively. Similarly, greater impairment in ejection fraction was observed in hypertrophied hearts with MRI (39 +/- 4% vs. 49 +/- 2%; P = 0.02). Gadophrin-3 provides accurate estimation of infarct size in hypertrophied hearts. Hypertrophied hearts are more sensitive to ischemia than nonhypertrophied hearts. The complementary assessment of Gadophrin-enhancement and LV function with MRI provides unique information about myocardium sensitivity to ischemia.

Animals↗

Myocardial perfusion imaging using OMNISCAN: a dose finding study for visual assessment of stress-induced regional perfusion abnormalities.

BACKGROUND: Different doses of contrast agent are applied for magnetic resonance perfusion studies and mainly semiquantitative approaches have been reported for analysis. We aimed to determine the optimal dose for a visual detection of perfusion defects. METHODS: 49 patients (59+/-8 years; 33 male) scheduled for invasive angiography were examined at stress (0.14 mg adenosine/kg body weight/minute) and rest using a TFE-EPI hybrid sequence (Philips ACS NT; 1.5 T). Patients were assigned to three different dose groups of gadodiamide (0.05, 0.1, and 0.15 mmol/kg body weight) injected as a bolus via a peripheral vein. Visual assessment was used to detect a regional reduction of peak signal intensity or speed of contrast agent inflow at stress in comparison to rest. RESULTS: Prevalence for coronary artery disease was 67%. The highest diagnostic accuracy was reached for a dose of 0.1 mmol gadodiamide/kg body weight (86% p=nonsignificant vs. 0.15 and 0.05 mmol gadodiamide/kg). At this dose, no major artifacts related to the contrast agent were found. CONCLUSIONS: Visual assessment of myocardial perfusion using a high-flow rate contrast agent bolus injection and a TFE-EPI sequence can be best achieved with a dose of gadodiamide 0.1 mmol/kg bodyweight.

Aged↗

Transendocardial delivery of extracellular myocardial markers by using combination X-ray/MR fluoroscopic guidance: feasibility study in dogs.

PURPOSE: To demonstrate the feasibility of using a combination of x-ray fluoroscopic and magnetic resonance (MR) fluoroscopic (ie, x-ray/MR fluoroscopy) guidance for left ventricular (LV) catheterization and transendocardial delivery of extracellular tissue markers. MATERIALS AND METHODS: Experiments were performed in six dogs by using an x-ray/MR fluoroscopy system. The arterial guide wire and catheter were advanced into the heart with x-ray fluoroscopic guidance. The dogs were injected with 0.5, 1.0, and 2.0 mL of iohexol. For passive catheter tracking, a steady-state free precession MR imaging sequence was used. A steerable dual-lumen catheter was used to transendocardially inject a mixture of gadodiamide (0.05 mol/L) plus Evans blue dye (3%). An electrocardiographically gated dual-inversion-recovery MR imaging sequence was used to visualize the myocardial delivery of the gadodiamide-blue dye mixture. A high concentration of gadodiamide (0.5 mol/L) was used to demarcate the borders of the area of interest, or "hit the target." Blood pressure, heart rate, and oxygen saturation were measured before and after the intervention. Analysis of variance, Scheffé, and paired Student t tests were used for data analysis. RESULTS: LV catheterization via arterial access was feasible with two-dimensional x-ray fluoroscopic and three-dimensional MR fluoroscopic guidance. Delivery of the gadodiamide-blue dye mixture and the consequences of the procedure were monitored with MR imaging. Gadolinium-enhanced regions were bright on T1-weighted MR images, but they varied in size as a function of injectant volume. The mean sizes of these regions were 1.5% +/- 0.6 of the LV after the 0.5-mL injection of the mixture and 7.0% +/- 0.5 of the LV after the 2.0-mL injection (P <.001, Scheffé test). The corresponding mean sizes of the blue dye-enhanced regions were 2.3% +/- 0.6 and 8.3% +/- 0.4, respectively (P <.001). A high concentration of gadodiamide caused signal intensity loss around the gadolinium-enhanced regions. CONCLUSION: Transendocardial delivery of potential therapeutic solutions is feasible with x-ray/MR fluoroscopic guidance. The injection catheter can be navigated with MR imaging guidance to hit the target.

Animals↗

Effect of potassium-channel opener therapy on reperfused infarction in hypertrophied hearts: demonstration of preconditioning by using functional and contrast-enhanced magnetic resonance imaging.

Effects of therapy with the potassium-channel opener and vasodilator nicorandil were studied in reperfused infarction of hypertrophied hearts by using magnetic resonance imaging (MRI), hemodynamic measurements, and histochemical staining. Aortic banding was performed on 22 Sprague-Dawley rats to induce left ventricular (LV) hypertrophy; 11 were the controls. Eight weeks later, the left coronary artery was occluded for 25 minutes in all 33 animals, followed by 3 hours of reperfusion. During occlusion, 11 rats with LV hypertrophy received nicorandil (0.1 mg/kg bolus and 1.5 mg/kg/h for 3 hours). The new necrosis-specific contrast agent Gadophrin-3 was administered to all animals to delineate infarction on multislice T1-weighted spin-echo MRI. Nicorandil increased ischemic tolerance of LV hypertrophy as shown by the reduction of infarction size from 19.3% +/- 1.3% to 10.0% +/- 2.5% LV (P = .005). Infarction size in treated animals was identical to control (9.3% +/- 1.6%). Close correlation was found between MRI and postmortem findings. Functional MRI revealed an improvement in ejection fraction in nicorandil-treated hearts (48.5% +/- 3.4% vs 38.1% +/- 3.2%, P = .04). LV end-diastolic volume and pressure, aortic pressure, and peripheral vascular resistance were highest in untreated hypertrophied hearts. Brief ischemia caused severe injury in hypertrophied hearts. Infusing nicorandil increased the tolerance of hypertrophied hearts to ischemia. MRI is a suitable technique for the evaluation of new therapies in LV hypertrophy.

Animals↗

Magnetic resonance--guided cardiac catheterization in a swine model of atrial septal defect.

BACKGROUND: Radiation exposure during cardiac catheterization, limited image planes, and poor soft tissue definition are disadvantages of x-ray fluoroscopy that could be overcome with the use of MRI. This study evaluates the feasibility of real-time MRI (MR fluoroscopy) to guide left and right heart catheterization. METHODS AND RESULTS: Anesthetized pigs (n=7) with defects of the atrial septum were catheterized using venous and arterial access. A prototype active tracking catheter was used to obtain blood pressures and samples from cardiac chambers and great vessels using antegrade, transseptal, and retrograde approaches. MR fluoroscopy was used for catheter steering. Velocity-encoded cine MRI was used to measure pulmonary and aortic blood flow to calculate vascular resistances. Image planes used during catheter manipulation used rapid sequencing to planes directed by the operator to include the tip of the catheter and the chamber to be entered. All areas of interest were effectively entered, and samples were obtained. In the presence of an acute atrial septal defect, a Qp/Qs ratio of 1.3+/-0.2 was measured, and no significant differences in pressure between inferior vena cava, right atrium, and left atrium were found. Pulmonary and aortic flow were 4.9+/-0.6 and 3.7+/-0.4 L/min, and pulmonary and systemic vascular resistance were 312+/-134 and 2006+/-336 dyne x s x cm(-5). CONCLUSIONS: Left and right heart catheterization using MR guidance is feasible. The combination of hemodynamic catheterization data with anatomic and functional MRI may significantly improve the evaluation of patients with congenital heart disease while avoiding radiation exposure.

Animals↗

Noninvasive determination of coronary blood flow velocity with cardiovascular magnetic resonance in patients after stent deployment.

BACKGROUND: In patients with coronary artery stents, no direct noninvasive coronary artery imaging is possible with magnetic resonance (MR). A well-established method for the assessment of the functional significance of a coronary lesion is the measurement of coronary flow reserve by invasive intracoronary Doppler. The purpose of the study was to determine coronary flow velocity reserve (CFVR) with MR after stent deployment. METHODS AND RESULTS: Thirty-eight patients after successful PTCA and stent deployment were included. CFVR was measured perpendicular to the artery distal to the stent using phase-contrast velocity quantification at rest and during adenosine-stimulated hyperemia with a 1.5T MR tomograph (ACS NT, Philips). Measurements were repeated after 3 months and compared with invasive coronary angiography. In 18 patients, additional invasive Doppler flow measurements were obtained. CFVR could be determined in 29 of 38 (76%) of the patients. After 3 months, significant differences were obtained between coronary arteries with and without restenosis. Using a threshold of 1.2, a sensitivity of 83% with a specificity of 94% was achieved for > or =75% stenoses. CFVR with CMR was similar to Doppler results (r=0.87), with a mean relative difference of 7.5%. CONCLUSIONS: In patients with preserved coronary microcirculating vasoreactivity that are suitable for MR coronary angiography and flow assessments, CMR measures of coronary blood flow velocities reserve may be used to detect in-stent restenosis.

Blood Flow Velocity↗

Improvement of image quality of non-invasive coronary artery imaging with magnetic resonance by the use of the intravascular contrast agent Clariscan (NC100150 injection) in patients with coronary artery disease.

PURPOSE: To assess the feasibility of Clariscan, an intravascular contrast agent, for free breathing, navigator assisted, high resolution, three-dimensional-magnetic resonance coronary angiography (MRCA) in patients, as extracellular contrast agents are unfavorable for the improvement of image quality. MATERIALS AND METHODS: MRCA was performed in 10 patients with known coronary artery disease (CAD) with (1-5 mg Fe/kg body weight) and without contrast agent. RESULTS: Compared to unenhanced images, Clariscan did not improve signal-to-noise (SNR) or contrast-to-noise ratios (CNR) compared to fat or myocardium in the proximal parts of the coronary arteries. However, when analyzing the peripheral parts (>4 cm from origin), CNR(fat) and CNR(myo) improved up to a factor of 1.81 and 5.85, respectively, at a dose of 3 mg Fe/kg body weight, while SNR did not reach statistical significance. The visible length of the coronary arteries was improved from 49 +/- 18 mm to 73 +/- 33 mm. The proximal diameter was reduced from 3.6 +/- 0.8mm to 3.2 +/- 0.8 mm, representing more closely the diameter of 3.1 +/- 0.7 mm measured by quantitative coronary angiography. Of 11 significant stenoses (>50%), eight were identified in the enhanced compared to six in the unenhanced images. CONCLUSION: The use of Clariscan at a dose of 2-3 mg Fe/kg body weight improves image quality of three-dimensional-MRCA, especially in the peripheral segments, and, thus, the diagnostic accuracy for the detection of CAD.

Analysis of Variance↗

Real-time MR image acquisition during high-dose dobutamine hydrochloride stress for detecting left ventricular wall-motion abnormalities in patients with coronary arterial disease.

PURPOSE: To compare the accuracy of real-time magnetic resonance (MR) imaging with that of standard echo-planar MR imaging for detecting myocardial wall-motion abnormalities at rest and during dobutamine hydrochloride-induced stress in patients with coronary arterial disease. MATERIALS AND METHODS: In 22 patients with coronary arterial disease, left ventricular wall motion was examined at rest and during dobutamine hydrochloride stress, by using echo-planar MR imaging and a new technique with real-time segmented k-space turbo gradient-echo echo-planar MR imaging (repetition time, 16.5 msec; echo time, 6.8 msec). Wall-motion abnormalities were determined visually for each perfusion territory, and Cohen kappa coefficients were calculated for real-time imaging in comparison with echo-planar imaging. Coronary angiography was performed in all patients. Sensitivity and specificity for real-time and echo-planar imaging were calculated for detecting significant coronary arterial stenosis. RESULTS: kappa values for detecting wall-motion abnormalities at real-time imaging, in comparison with echo-planar MR imaging, were 0.97 at rest and 0.94 at maximum dobutamine hydrochloride stress. At comparison with those of angiography, the sensitivity and specificity for detecting significant coronary arterial stenosis were 88% (14 of 16 patients) and 83% (five of six patients), respectively, for echo-planar imaging and 81% (13 of 16 patients) and 83% (five of six patients), respectively, for real-time imaging. CONCLUSION: Real-time MR imaging is possible under stress conditions and allows accurate detection of wall-motion abnormalities.

Cardiotonic Agents↗

Contrast agents for cardiovascular magnetic resonance imaging. Current status and future directions.

Magnetic resonance imaging (MRI) can provide a non-invasive combined diagnostic examination of different modalities including visualisation of vascular and cardiac anatomy and measurements of blood flow and left ventricular mass, function, perfusion and viability. Contrast agents for cardiovascular imaging are used to enhance the capability of MRI in assessing perfusion, tissue viability, infarction and vascular stenosis. Furthermore, contrast agents may be used for guiding procedures and therapies in the evolving field of interventional MRI such as angioplasty and delivery of genes and growth factors. Targeted MR contrast agents are needed to further improve the specificity of MRI and to monitor pathophysiological processes including necrosis, inflammation or angiogenesis. The research and development of MR contrast agents will continue at the cellular and molecular levels in the next decade.

Animals↗