PubMed Health⌕ Search

Biomedical subjects

Simon Wildermuth

Publications and source records attributed to Simon Wildermuth.

At least 19 recordsLinked to original sources

Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography.

We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 +/- 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 +/- 0.39 mm versus 2.49 +/- 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 +/- 6.2 mm, correlating well with CT (18.5 +/- 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 +/- 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA.

Adult↗

Visualization of congenital thoracic vascular anomalies using multi-detector row computed tomography and two- and three-dimensional post-processing.

Anomalies of the vascular system are caused by false embryogenesis and are therefore present from birth. Single-detector row spiral computed tomography angiography (CTA) and multi-detector row computed tomography angiography (MDCTA) have gained increasing importance in the non-invasive assessment of vascular pathologies and replace conventional angiography in many cases. High-resolution volumetric datasets that are acquired during a single breath-hold give the possibility of two- (2D) and three-dimensional (3D)-post-processing. Due to post-processing, even complex vascular malformations are visualized in an understandable way. Furthermore, CTA, in contrast to conventional angiography, depicts not only the vascular structures but also allows assessment of the surrounding anatomical structures. We present cases of rare congenital anomalies of the thoracic vessels using MDCT with special respect to 2D- and 3D-post-processing.

Algorithms↗

Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality.

PURPOSE: To evaluate prospectively the effect of average heart rate and heart rate variability on image quality at 64-section computed tomographic (CT) coronary angiography. MATERIALS AND METHODS: The study protocol had local ethics committee approval; written informed consent was obtained. There were 125 patients (45 women, 80 men; mean age, 59.9 years +/- 12.9 [standard deviation]; 79 receiving beta-blockers) who underwent 64-section CT coronary angiography with retrospective electrocardiographic gating. Data sets were reconstructed in 5% steps from 20% to 80% of R-R interval. Heart rate variability was calculated as 1 standard deviation from mean rate during scanning. Two observers rated image quality of each coronary segment at least 1.5-mm diameter (1 = no motion artifacts, 5 = not evaluative). Repeated analysis of variance measurements were performed to evaluate quantitative parameters. Pearson correlation analysis was performed to compare image quality in each patient with average heart rate and heart rate variability. RESULTS: Average heart rate was 63.3 beats per minute +/- 13.1, with variability of 3.2 beats per minute +/- 2.1. Diagnostic image quality (score < or = 3) was attained in 1821 of 1836 segments at the best reconstruction interval. There was no correlation between mean heart rate and image quality for all segments of the right coronary and left anterior descending arteries, but there was a significant correlation for left circumflex artery (r = 0.33, P < .05). Heart rate variability was correlated with image quality overall (r = 0.75, P < .001) and for each coronary artery. Heart rate was less variable and image quality was better (P < .05) in patients receiving beta-blockers. Best image quality was obtained in diastole with heart rate less than 80 beats per minute and in systole with faster heart rate. CONCLUSION: Coronary angiography with 64-section CT provides diagnostic image quality within a wide range of heart rates. Reducing average heart rate and heart rate variability is beneficial for reducing artifacts.

Adult↗

Coronary artery imaging with 64-slice computed tomography from cardiac surgical perspective.

INTRODUCTION: 64-Slice computed tomography (CT) has been introduced with high expectations. This study illustrates the value of 64-slice CT for the diagnosis of significant coronary artery stenoses when images are analysed by cardiovascular surgeons. METHODS: Fifty patients (39 males, 11 females) underwent invasive coronary angiography and 64-slice CT. In these patients, 40 had coronary artery disease and 10 patients had valvular disease. Evaluation of right coronary artery (RCA), left main (LM), left anterior descending artery (LAD), diagonal branch 1 (D1), circumflex branch (CX), and 1st marginal branch was performed by two cardiovascular surgeons. All vessels with a diameter >/=1.5 mm were analysed and a lumen restriction of >50% was considered a significant stenosis. CT image quality was classified as excellent, reduced but still diagnostic, and not assessable. Invasive coronary angiography was taken as gold standard for calculations of diagnostic accuracy. RESULTS: Mean heart rate during CT scan was 65+/-11 beats per minute (bpm). Image quality of 92% (506/550) of all segments was rated as excellent, 5% (27/550) were rated as being of reduced quality but still diagnostic, and 3% (17/550) were considered not assessable. The sensitivity for diagnosing a significant stenosis with CT when including all reliably evaluated segments was 93% (106/114), specificity was 97% (381/392), positive predictive value was 91% (106/117), and negative predictive value was 98% (381/389). CONCLUSION: 64-Slice CT provides a high diagnostic accuracy in assessing significant coronary artery stenosis. Nevertheless, still exist some disadvantages such as strong vessel wall calcifications reducing the reliability for image interpretation. At the moment, 64-slice CT should be used as a complementary imaging modality to invasive coronary angiography.

Aged↗

Aortic stenosis: comparative evaluation of 16-detector row CT and echocardiography.

PURPOSE: To prospectively evaluate whether planimetric measurements of aortic valve area (AVA) with 16-detector row computed tomography (CT) allow classification of aortic stenosis (AS). MATERIALS AND METHODS: The study had institutional review board approval; patients gave informed consent. Twenty patients (11 men, nine women; mean age, 63 years) with AS and 20 patients (10 men, 10 women; mean age, 65 years) without underwent transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and retrospectively electrocardiographically gated 16-detector row CT. Twenty CT data sets were reconstructed in 5% steps of R-R interval; data analysis was performed with four-dimensional software. Maximum AVA in systole planimetrically measured with CT (AVA(CT)) was compared with AVA planimetrically measured with TEE (AVA(TEE)), AVA calculated with the continuity equation and TTE (AVA(TTE)), and transvalvular pressure gradients determined with the Bernoulli equation and TTE. Correlations among AVA(CT), AVA(TTE), AVA(TEE), and transvalvular pressure gradients were tested with bivariate regression analysis; agreement between methods was assessed with the Bland-Altman method. RESULTS: In patients without AS, mean AVA(CT) was 3.56 cm2 +/- 0.66 and mean AVA(TEE) was 3.43 cm2 +/- 0.69. In patients with AS, mean AVA(CT) was 0.89 cm2 +/- 0.35; mean AVA(TEE), 0.86 cm2 +/- 0.35; and mean AVA(TTE), 0.83 cm2 +/- 0.33. Mean transvalvular pressure gradient was 51 mm Hg +/- 22. Significant correlations were present between AVA(CT) and AVA(TEE) (r = 0.99, P < .001), AVA(CT) and AVA(TTE) (r = 0.95, P < .001), and AVA(CT) and transvalvular pressure gradients (r = -0.74, P < .01). Mean differences were -0.08 cm2 (limits of agreement: -0.32, 0.16) for AVA(CT) versus AVA(TEE) and 0.06 cm2 (limits of agreement: -0.15, 0.26) for AVA(CT) versus AVA(TTE). CONCLUSION: Planimetric measurements of AVA with retrospectively electrocardiographically gated 16-detector row CT allow classification of AS that is similar to that achieved with measurements by using echocardiographic methods.

Aged↗

Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography.

The purpose of this study was to evaluate the influence of ejection fraction (EF), stroke volume (SV), heart rate, and cardiac output (CO) on coronary artery opacification with 64-slice computed tomography (CT). Sixty patients underwent, retrospectively, electrocardiography-gated 64-slice CT coronary angiography. Left ventricular EF, SV, and CO were calculated with semi-automated software. Attenuation values were measured and contrast-to-noise ratios (CNRs) were calculated in the proximal right coronary artery (RCA) and left main artery (LMA). Mean EF during scanning was 61.5+/-12.4%, SV was 63.2+/-15.6 ml, heart rate was 62.5+/-11.8 beats per minute (bpm), and CO was 3.88+/-1.06 l/min. There was no significant correlation between the EF and heart rate and the attenuation and CNR in either coronary artery. A significant negative correlation was found in both arteries between SV and attenuation (RCA r=-0.26, P<0.05; LMA r=-0.34, P<0.01) and between SV and CNR (RCA r=-0.26, P<0.05; LMA r=-0.26, P<0.05). Similarly, a significant negative correlation was found between the CO and attenuation (RCA r=-0.42, P<0.05; LMA r=-0.56, P<0.001) and between the CO and CNR (RCA r=-0.39, P<0.05; LMA r=-0.44, P<0.001). The actual hemodynamic status of the patient influences the coronary artery opacification with 64-slice CT, in that vessel opacification decreases as SV and CO increase.

Adult↗

CT angiography of peripheral arterial bypass grafts: Accuracy and time-effectiveness of quantitative image analysis with an automated software tool.

RATIONALE AND OBJECTIVES: Qualitative analysis of computed tomography (CT) angiography data often is limited by intra- and interobserver variability. The purpose of this study was to evaluate the time-effectiveness and accuracy of a quantitative CT angiography data analysis using automated software in comparison with qualitative axial and coronal CT image reading in patients with peripheral bypass grafts. MATERIALS AND METHODS: Twenty-eight patients with 33 saphenous bypass grafts underwent 4-channel (n = 21) and 16-channel (n = 7) CT angiography. Two readers evaluated in consensus the CT data qualitatively on axial and coronal reconstructions and with the software regarding the presence of graft stenoses, aneurysmal changes, and arteriovenous fistulas. The time for data analysis was taken and the accuracy was compared with the results from digital subtraction angiography (DSA). RESULTS: No significant difference was present between data analysis time using axial and coronal CT images (4.9 +/- 1.5 minutes) and when using the software tool (5.5 +/- 1.4 minutes). Good (kappa = 0.652) to excellent (kappa = 1.000) intermodality agreement was present between qualitative and quantitative CT analysis regarding graft-related abnormalities. Sensitivity and specificity for diagnosing stenoses, aneurysms, and fistula did not differ significantly (P > .025) between qualitative CT image reading and the automated software tool. CONCLUSIONS: CT angiography analysis of peripheral bypass grafts using an automated software tool is similar regarding time-effectiveness and accuracy when compared with qualitative CT data analysis on axial and coronal images. It may assist in determining the significance of an abnormality and can yield objective morphometric data of vessel calibers.

Algorithms↗

Sixteen-channel multidetector row computed tomography versus coronary angiography in a surgical view.

BACKGROUND: Invasive coronary angiography (ICA) is the gold standard for the diagnosis of coronary artery disease and also for imaging procedures for preoperative planning of coronary artery bypass grafting (CABG). Sixteen-multidetector row computed tomography (MDCT) represents an alternative depiction of coronary vessels. METHODS: Preoperative exams included ICA and MDCT in 50 patients. Two blinded surgical readers independently investigated both diagnostic modalities regarding location, severity, and morphology of the stenoses. The right coronary artery, left anterior descending branch, and circumflex branch--each divided in 3 sections--and the left main artery with a diameter (3) 1.5 mm were rated in both procedures, and the percentage of complete evaluations by MDCT was assessed. RESULTS: Heart rate was 72 +/- 8 bpm. Forty-six percent of patients received a complete MDCT evaluation, and 54% received an incomplete MDCT evaluation. In 62% of these incompletely examined patients, 1 branch was not completely analyzable, in 31% 2 branches; and in 7% all 3 branches. In total, 9% of all segments were incompletely assessed. Investigators detected coronary stenoses in complete evaluations with a sensitivity of 94% and a specificity of 95%. Positive predictive value was 87% and negative predictive value was 98%. Plaque classification in soft and hard plaques was possible. CONCLUSION: Sixteen-MDCT is not a viable alternative diagnostic tool at present. However, although the percentage of incomplete evaluated patients is more then 50%, only 9% of all segments were incompletely assessable. If this technology can be further improved, especially its software, it will become a valid diagnostic tool for coronary artery disease.

Coronary Angiography↗

Segmental arterial mediolysis: CTA findings at presentation and follow-up.

OBJECTIVE: Segmental arterial mediolysis is a rare noninflammatory vascular disease of the abdominal splanchnic arteries. The purpose of our study was to retrospectively describe the CT angiography (CTA) findings of this disease and the evolution of those findings over time in five patients. CONCLUSION: Comparison of CTA and digital subtraction angiography suggests that CTA is useful to diagnose symptomatic segmental arterial mediolysis. Midterm CTA follow-up (median, 3 years) indicates that segmental arterial mediolysis lesions may resolve or remain unchanged.

Aged↗

Mitral regurgitation: quantification with 16-detector row CT--initial experience.

PURPOSE: To prospectively determine if retrospectively electrocardiographic (ECG)-gated multi-detector row computed tomography (CT) with a 16-detector row CT scanner can depict mitral regurgitation and enable quantification of the severity of the disease. MATERIALS AND METHODS: The study had institutional review board approval, and patients gave informed consent. Nineteen patients with mitral regurgitation (10 men, nine women; mean age, 66 years +/- 9 [standard deviation]; range, 41-83 years) and 25 patients without mitral regurgitation (14 men, 11 women; mean age, 68 years +/- 9; range, 43-83 years) as determined with transesophageal color Doppler echocardiography and ventriculography underwent retrospectively ECG-gated 16-detector row CT. Twenty CT data sets covering the entire mitral valve apparatus were reconstructed in 5% steps of the R-R interval for each patient, and data analysis was performed with four-dimensional software. Using planimetry, two readers measured in consensus the area of the regurgitant orifice during systole. These measurements were compared with semiquantitative data from transesophageal echocardiography and ventriculography by using Spearman rank order correlation coefficients. RESULTS: In the 25 patients without mitral regurgitation, no regurgitant orifice during systole could be detected with multi-detector row CT. In the 19 patients with mitral regurgitation, a regurgitant orifice could be visualized in all cases. The mean regurgitant orifice area at CT-45 mm(2) +/- 34 (range, 10-148 mm(2))-correlated significantly with the results at transesophageal echocardiography (r = 0.807, P < .001) and ventriculography (r = 0.922, P < .001). CONCLUSION: Planimetric measurements of the regurgitant orifice area at retrospectively ECG-gated 16-detector row CT enable quantification of mitral regurgitation.

Adult↗

Coronal thick CT reconstruction: an alternative for initial chest radiography in trauma patients.

It has been proposed that the imaging workup of trauma patients be accelerated by omitting the initial chest radiography (CR) and directly performing a computed tomography (CT); however, the baseline CR is then lacking. The purpose of this study was to assess if coronal thick reconstructions generated from chest CT could present an adequate alternative for CR. Sixty trauma patients underwent bedside CR and multidetector row chest CT in the emergency room. The image quality of thoracic anatomical structures, the diagnostic accuracy for chest pathology, and the depiction of indwelling devices were assessed on both modalities. Main pulmonary arteries and perihilar bronchi were equally visualized with both modalities. Central bronchi, retrocardial lung parenchyma, diaphragm, descending aorta, and vertebral pedicles were better visualized on thick CT reconstructions, whereas peripheral lung vessels were better depicted on CR (p<0.05). The accuracy to delineate various pathological findings did not differ between both modalities, except for a higher sensitivity to diagnose bronchial cuffing on CR (p<0.05). The location of indwelling devices was similarly and correctly depicted with both modalities. Coronal thick CT reconstructions provide a similar image quality and diagnostic accuracy compared with CR. These reconstructions may serve as an equivalent baseline image in trauma patients in whom emergency radiological evaluation has to be accelerated.

Adolescent↗

Comparison of retrospectively ECG-gated and nongated MDCT of the chest in an emergency setting regarding workflow, image quality, and diagnostic certainty.

PURPOSE: This study aims to assess the influence of ECG-gated acquisition on workflow and to compare image quality and diagnostic certainty for retrospectively ECG-gated and nongated multidetector computed tomography of the chest in the emergency suite. MATERIALS AND METHODS: Thirty-two consecutive patients were referred for both an ECG-gated and a nongated CT to rule out traumatic thoracic injury (n=15) or acute aortic dissection (n=17). The time from the start of the transportation from the emergency suite to the CT room until the start of the CT scan was recorded. Using a scoring system, the image quality of axial images and multiplanar reformats, the presence of disease, and the subjective diagnostic certainty were assessed with regard to the vascular structures, the bone structures, and the lung parenchyma. RESULTS: The time needed for transportation and patient preparation was 12.1+/-1.7 min (8.1-14.5 min). The motion artifacts of the thoracic aorta and the supra-aortic vessels were significantly reduced in the ECG-gated data acquisition compared with the nongated technique (P<0.001). Subjective diagnostic certainty for assessment of the aorta was significantly better using ECG gating. The image quality of the lung parenchyma (P<0.005), the spine (P<0.005), and the ribs (P<0.002) was inferior in the ECG-gated data sets but did not compromise the detection rate of traumatic lesions and fractures. CONCLUSION: Performing ECG gating in the emergency room did not slow down the diagnostic workup. ECG-gated acquisition performed better in the assessment of the aorta, but image quality for lung and bone structures was slightly reduced. Further studies are required to assess the influence of the imaging technique on the diagnostic outcome.

Aorta, Thoracic↗

Multi-detector computed tomography of acute abdomen.

Acute abdominal pain is one of the most common causes for referrals to the emergency department. The sudden onset of severe abdominal pain characterising the "acute abdomen" requires rapid and accurate identification of a potentially life-threatening abdominal pathology to provide a timely referral to the appropriate physician. While the physical examination and laboratory investigations are often non-specific, computed tomography (CT) has evolved as the first-line imaging modality in patients with an acute abdomen. Because the new multi-detector CT (MDCT) scanner generations provide increased speed, greater volume coverage and thinner slices, the acceptance of CT for abdominal imaging has increased rapidly. The goal of this article is to discuss the role of MDCT in the diagnostic work-up of acute abdominal pain.

Abdomen, Acute↗

Aortoiliac and lower extremity arteries assessed with 16-detector row CT angiography: prospective comparison with digital subtraction angiography.

PURPOSE: To prospectively compare the accuracy of 16-detector row computed tomographic (CT) angiography with conventional digital subtraction angiography (DSA) as the reference standard in the assessment of aortoiliac and lower extremity arteries in patients with peripheral arterial disease. MATERIALS AND METHODS: This study was approved by the institutional review board, and informed consent was obtained. A total of 39 consecutive patients (27 men [mean age, 66 years] and 12 women [mean age, 64 years]) with peripheral arterial disease underwent both conventional DSA and 16-detector row CT angiography. For data analysis, the arterial vascular system was divided into 35 segments. A total of 1365 arterial segments were analyzed for arterial stenosis by two independent blinded readers using a four-point grading system (grade 1, <10% luminal narrowing; grade 2, 10%-49% luminal narrowing; grade 3, 50%-99% luminal narrowing; grade 4, occlusion). Interobserver agreements were calculated by using kappa statistics. A third independent blinded reader assessed possible reasons for disagreements between 16-detector row CT angiographic findings and conventional DSA findings. Effective radiation dose was calculated for both imaging modalities. RESULTS: Sixteen-detector row CT angiographic and conventional DSA findings were diagnostic in all vascular segments. Compared with conventional DSA, the sensitivity and specificity of 16-detector row CT angiography with regard to detection of hemodynamically significant stenosis in all 35 arterial segments were 96% and 97%, respectively, for both readers. Readers 1 and 2 overestimated arterial stenosis in 42 (3%) and 34 (2%) arterial segments, respectively, and underestimated arterial stenosis in 13 (1%) and 10 (1%) arterial segments, respectively. Interobserver agreement was excellent (kappa = 0.84-1.00). Presence of anteroposteriorly located luminal narrowing and extensive vascular wall calcification were considered main reasons for disagreements between imaging modalities. Effective radiation dose was lower for 16-detector row CT angiography (1.6-3.9 mSv) than for conventional DSA (6.4-16.0 mSv). CONCLUSION: Sixteen-detector row CT angiography is an accurate and reliable noninvasive alternative to conventional DSA in the assessment of aortoiliac and lower extremity arteries in patients with peripheral arterial disease.

Adult↗

Accuracy of MSCT coronary angiography with 64-slice technology: first experience.

AIMS: The aim of our study was to investigate the accuracy of 64-slice computed tomography (CT) for assessing haemodynamically significant stenoses of coronary arteries. METHODS AND RESULTS: CT angiography was performed in 67 patients (50 male, 17 female; mean age 60.1+/-10.5 years) with suspected coronary artery disease and compared with invasive coronary angiography. All vessels > or =1.5 mm were considered for the assessment of significant coronary artery stenosis (diameter reduction >50%). Forty-seven patients were identified as having significant coronary stenoses on invasive angiography with 18% (176/1005) affected segments. None of the coronary segments needed to be excluded from analysis. CT correctly identified all 20 patients having no significant stenosis on invasive angiography. Overall sensitivity for classifying stenoses was 94%, specificity was 97%, positive predictive value was 87%, and negative predictive value was 99%. CONCLUSION: Sixty-four-slice CT provides a high diagnostic accuracy in assessing coronary artery stenoses.

Adult↗

Multislice CT in the pre- and postinterventional evaluation of mesenteric perfusion.

Multislice computed tomography angiography (CTA) has been found feasible for the evaluation of visceral vasculature. The development of multislice technology has overcome past limitations. First, the faster scanning speed increases volume coverage during a single breath-hold and improves the exploitation of contrast medium. Second, the better spatial resolution results in nearly isotropic voxels allowing reconstruction of high-resolution three-dimensional images with different algorithms. Volume rendering is capable of displaying the visceral vasculature from any external vantage point. Compared to conventional angiography, CTA not only delineates vessels but also depicts the anatomical relationship to adjacent structures and allows the evaluation of perfused organs. CTA also has become an emerging tool for the pre- and postinterventional assessment of vascular anatomy. The purpose of this pictorial essay is to present a spectrum of visceral vascular diseases and interventional and surgical therapies, and to highlight the role of postprocessing for their evaluation.

Adult↗