PubMed Health⌕ Search

Biomedical subjects

Simone Giannerini

Publications and source records attributed to Simone Giannerini.

3 recordsLinked to original sources

Chaotic phenomena of charged particles in crystal lattices.

In this article, we have applied the methods of chaos theory to channeling phenomena of positive charged particles in crystal lattices. In particular, we studied the transition between two ordered types of motion; i.e., motion parallel to a crystal axis (axial channeling) and to a crystal plane (planar channeling), respectively. The transition between these two regimes turns out to occur through an angular range in which the particle motion is highly disordered and the region of phase space spanned by the particle is much larger than the one swept in the two ordered motions. We have evaluated the maximum Lyapunov exponent with the method put forward by Rosenstein et al. [Physica D 65, 117 (1993)] and by Kantz [Phys. Lett. A 185, 77 (1994)]. Moreover, we estimated the correlation dimension by using the Grassberger-Procaccia method. We found that at the transition the system exhibits a very complex behavior showing an exponential divergence of the trajectories corresponding to a positive Lyapunov exponent and a noninteger value of the correlation dimension. These results turn out to be linked to a physical interpretation. The Lyapunov exponents are in agreement with the model by Akhiezer et al. [Phys. Rep. 203, 289 (1991)], based on the equivalence between the ion motion along the crystal plane described as a "string of strings" and the "kicked" rotator. The nonintegral value of the correlation dimension can be explained by the nonconservation of transverse energy at the transition.

Journal Article↗

Accuracy rates of US-guided vacuum-assisted breast biopsy.

A prospective study designed to measure the accuracy of mammography (MRx), ultrasound (US), fine-needle aspiration cytology (FNAC) and one of the most recently introduced techniques, vacuum biopsy (VB), in the diagnosis of breast cancer is reported. A sample of 146 breast lesions on 135 patients were examined. The design of the study made it possible to compare MRx, US, FNAC and VB directly, because it excluded several confounding variables. Statistical indicators--sensitivity, specificity, predictive values (PPV and NPV), false-negative and false-positive rates (FN and FP), suspicious plus indeterminate rate and likelihood ratios (LR)--were calculated. The NPV of MRx and US were remarkably high (92.4% and 97.9%, respectively), confirming previous reports. The complete sensitivity of FNAC was 80%, while specificity was 99.1% and LR of positive tests 88.8. The combined score of FNAC, US and MRx resulted in a good increase in complete sensitivity (97.1%), when compared with the results of the single diagnostic tests evaluated separately. The absolute sensitivity of VB was 97.1% and specificity was 100%. In conclusion, considered together, MRx, US and FNAC appear to be reliable diagnostic procedures and, when they are all negative, the possibility of a cancer is extremely low, although it cannot be completely ruled out. The VB test had the highest absolute sensitivity among all the methods compared. Therefore, this technique could be considered conclusive in diagnostically doubtful cases, avoiding open surgical biopsy.

Adult↗