PubMed Health⌕ Search

Biomedical subjects

Simone J H Wielders

Publications and source records attributed to Simone J H Wielders.

6 recordsLinked to original sources

Synergistic effect of thrombin on collagen-induced platelet procoagulant activity is mediated through protease-activated receptor-1.

OBJECTIVE: In the blood coagulation process, the rate of thrombin formation is critically dependent on phosphatidylserine (PtdSer) at the surface of activated platelets. Thrombin synergistically enhances the collagen-induced platelet procoagulant response. The objective of this study is to elucidate the mechanism of this synergistic action with a focus on the intracellular Ca2+ concentration ([Ca2+]i) and the various platelet receptors for thrombin. METHODS AND RESULTS: We demonstrate that procoagulant activity is related to a sustained increased [Ca2+]i, which in turn depends on extracellular Ca2+ influx. Increased PtdSer exposure coincides with increased [Ca2+]i and was observed in a subpopulation (approximately 14%) of the platelets after stimulation with thrombin plus collagen. 2D2-Fab fragments against the thrombin binding site on GPIbalpha made clear that this receptor did not signal for platelet procoagulant activity. Inhibition of protease-activated receptor 1 (PAR-1) and PAR-4 by selective intracellular inhibitors and selective desensitization of these receptors revealed that PAR-1, but not PAR-4, activation is a prerequisite for both sustained elevations in [Ca2+]i and procoagulant activity induced by collagen plus thrombin. CONCLUSIONS: The interaction of thrombin with PAR-1 mediates a synergistic effect on collagen-induced procoagulant activity by inducing a sustained elevation in [Ca2+]i in a subpopulation of platelets.

Apoptosis Regulatory Proteins↗

Factor XI-dependent reciprocal thrombin generation consolidates blood coagulation when tissue factor is not available.

OBJECTIVE: Feedback activation of factor XI by thrombin is a likely alternative for tissue factor-dependent propagation of thrombus formation. However, the hypothesis that thrombin can initiate and propagate its formation in a factor XI-dependent and platelet-dependent manner has not been tested in a plasma milieu. METHODS AND RESULTS: We investigated thrombin generation in recalcified platelet-rich plasma activated with varying amounts of thrombin or factor VIIa. Thrombin initiates and propagates dose-dependently thrombin generation only when platelets and plasma factor XI are present. Incubation of thrombin-activated platelets with a tissue factor neutralizing antibody had no effect on thrombin formation, indicating that platelet-associated tissue factor, if present at all, is not involved. In the absence of factor VIII, thrombin could not initiate its own formation, whereas factor VIIa-induced thrombin generation was reduced. Collagen strongly stimulated both thrombin-initiated and factor VIIa-initiated thrombin generation. CONCLUSIONS: These findings support the notion that platelet-localized feedback activation of factor XI by thrombin plays an important role in maintaining normal hemostasis as well as in sustaining thrombus formation when the TF pathway is inhibited by tissue factor pathway inhibitor.

Adult↗

Covalently-bound heparin makes collagen thromboresistant.

OBJECTIVE: Blood compatibility of artificial surfaces depends on their immunogenic and thrombogenic properties. Collagen's weak antigenicity makes it an attractive candidate for stent coatings or fabrication of vascular grafts. However, the thrombogenic nature of collagen limits its application. We examined whether heparinization can make collagen more thromboresistant. METHODS AND RESULTS: Collagen was heparinized by crosslinking collagen with extensively periodate oxidized heparin and/or by covalently bonding of mildly periodate oxidized heparin. Both ways of heparinization have no effect on platelet adhesion and could not abolish induction of platelet procoagulant activity. However, thrombin generation was completely prevented under static and flow conditions. The functionality of immobilized heparin was confirmed by specific uptake of antithrombin, 13.5+/-4.7 pmol/cm2 and 1.95+/-0.21 pmol/cm2 for mildly and heavily periodated heparin, respectively. CONCLUSIONS: These results indicate that immobilization of heparin on collagen, even as a crosslinker, is a very effective way to prevent surface thrombus formation. These data encourage the application of heparinized collagen as stent-graft material in animal and eventually human studies.

Animals↗

Coils and tubes releasing heparin. Studies on a new vascular graft prototype.

Coiled metallic guidewires find widespread use, for instance in interventional cardiology. It is known that release of heparin from the surface of guidewires is advantageous to prevent formation of thrombotic emboli. New coiled tubular structures, having larger inner and outer diameter as compared to guidewires, are presented. In theory these tubes can be used as interposition vascular grafts. Ten coiled tubes with an internal diameter of 690 microm were made. Five different adherent polymeric coatings with increasing hydrophilicity were used. Five tubes contained heparin in the coating and the other five were unheparinised controls. The five tubes containing heparin were studied with respect to heparin release in vitro (amount released, kinetics), and immobilised heparin that is exposed at the surface. All tubes were studied with a direct cell contact assay using 3T3 mouse fibroblast cells, a dynamic thrombin generation test, and endothelial cell growth onto the coils. It was found that the heparinised tubes lead to very little thrombin formation. It is argued that this is due to heparin that is immobilised and exposed at the inner surface of such tubes. Furthermore the coils showed to be cytocompatible and endothelial cells adhere and proliferate well onto the coils. This concept is believed to hold promise for further development of small vascular grafts.

3T3 Cells↗

Thrombogenicity of polysaccharide-coated surfaces.

Heparinization of artificial surfaces has been proven to reduce the intrinsic thrombogenicity of such surfaces. The mechanism by which immobilized heparin reduces thrombogenicity is not completely understood. In the present study heparin-, alginic acid- and chondroitin-6-sulphate-coated surfaces were examined for protein adsorption, platelet adhesion and thrombin generation. The protein-binding capacity from solutions of purified proteins was significantly higher for heparin-coated surfaces when compared with alginic acid- and chondroitin sulphate-coated surfaces. Yet, when the surfaces were exposed to flowing plasma, only the heparinized surface adsorbed significant amounts of antithrombin. None of the surfaces adsorbed fibrinogen under these conditions, and as a result no platelets adhered from flowing whole blood. Our results indicate that protein adsorption and platelet adhesion from anticoagulated blood cannot be used to assess the thrombogenicity of (coated) artificial surfaces. Indeed, the thrombin generation potentials of the different surfaces varied remarkable: while non-coated surface readily produced thrombin, alginic acid- and chondroitin sulphate-coated surfaces showed a marked reduction and virtually no thrombin was generated in flowing whole blood passing by heparinized surfaces.

Adsorption↗

Fibrinogen adsorption, platelet adhesion and thrombin generation at heparinized surfaces exposed to flowing blood.

Thrombus formation at an artificial surface in contact with blood is a complex process that encompasses accretion of platelets from flowing blood and fibrin deposition. Platelet adhesion and fibrin formation are intimately intertwined reactions that are triggered by different sets of surface adsorbed plasma proteins. To dissect the contribution of protein adsorption and platelet adhesion to thrombin formation, a coherent study was performed with non-coated (NC) and heparin-coated (HC) surfaces. Thrombin production in whole blood, platelet adhesion and protein adsorption were studied using an amidolytic thrombin assay, a dynamic platelet adhesion assay and ellipsometry, respectively. Thrombin generation in flowing whole blood exposed to HC surfaces was greatly diminished when compared with NC surfaces. However, separate platelet adhesion and protein adsorption studies with anticoagulated whole blood revealed that platelets do not adhere because fibrinogen is not available in the protein layer that was deposited during the perfusion. These findings indicate that the in vitro thrombogenicity of a material cannot be predicted from platelet adhesion and protein adsorption data when these measurements are performed with anti-coagulated blood or platelet rich plasma. Preincubation of NC and HC surfaces with fibrinogen or 2000-fold diluted plasma resulted in similar amounts of surface-bound fibrinogen and mediated massive platelet adhesion from flowing whole blood. These results indicate that a) platelet adhesion correlates with the availability of surface-bound fibrinogen and b) NC and HC surfaces are indistinguishable with respect to protein (fibrinogen) adsorption and platelet adhesion. It is apparent that the heparinized surface used in our studies exerts its anti-thrombogenic properties by neutralizing locally formed thrombin and not by reducing fibrinogen-dependent platelet adhesion.

Adsorption↗