PubMed Health⌕ Search

Biomedical subjects

Slav Yartsev

Publications and source records attributed to Slav Yartsev.

5 recordsLinked to original sources

A comparison of prostate IMRT and helical tomotherapy class solutions.

The purpose of this study was to assess a variety of potential IMRT class solutions as compared to a helical tomotherapy (HT) class solution for localized prostate cancer. Target and critical structures were contoured on 10 prostate cancer patient CT datasets. HT treatment plans were compared to four different IMRT approaches by paired t-tests. HT prostate planning generally provided treatment plans with excellent target homogeneity and favorable critical structure sparing when compared to conventional IMRT.

Humans↗

Comparative planning evaluation of intensity-modulated radiotherapy techniques for complex lung cancer cases.

BACKGROUND AND PURPOSE: Lung cancer treatment can be one of the most challenging fields in radiotherapy. The aim of the present study was to compare different modalities of radiation delivery based on a balanced scoring scheme for target coverage and normal tissue avoidance. PATIENTS AND METHODS: Treatment plans were developed for 15 patients with stage III inoperable non-small cell lung cancer using 3D conformal technique and intensity-modulated radiotherapy (IMRT). Elective nodal irradiation was included for all cases to create the most challenging scenarios with large target volumes. A 2 cm margin was used around the gross tumour volume (GTV) to generate PTV2 and 1cm margin around elective nodes for PTV1 resulting in PTV1 volumes larger than 1000 cm(3) in 13 of the 15 patients. 3D conformal and IMRT plans were generated on a commercial treatment planning system (TheraPlan Plus, Nucletron) with various combinations of beam energies and gantry angles. A 'dose quality factor' (DQF) was introduced to correlate the plan quality with patient specific parameters. RESULTS: A good correlation was found between the quality of the plans and the overlap between PTV1 and lungs. The patient feature factor (PFF), which is a product of several pertinent characteristics, was introduced to facilitate the choice of a particular technique for a particular patient. CONCLUSIONS: This approach may allow the evaluation of different treatment options prior to actual planning, subject to validation in larger prospective data sets.

Carcinoma, Non-Small-Cell Lung↗

Tomotherapy planning of small brain tumours.

Helical tomotherapy (HT) combines a rotating intensity modulated fan beam with integrated CT imaging for high precision radiotherapy. HT plans for 12 patients with small brain tumours were compared with five other radiotherapy techniques. Proton techniques gave overall the best results, while HT was shown to produce better target dose uniformity (average SD=1.3%) and kept irradiation of organs at risk as good as other photon methods.

Adenoma↗

Planning evaluation of radiotherapy for complex lung cancer cases using helical tomotherapy.

Lung cancer treatment is one of the most challenging fields in radiotherapy. The aim of the present study was to investigate what role helical tomotherapy (HT), a novel approach to the delivery of highly conformal dose distributions using intensity-modulated radiation fan beams, can play in difficult cases with large target volumes typical for many of these patients. Tomotherapy plans were developed for 15 patients with stage III inoperable non-small-cell lung cancer. While not necessarily clinically indicated, elective nodal irradiation was included for all cases to create the most challenging scenarios with large target volumes. A 2 cm margin was used around the gross tumour volume (GTV) to generate primary planning target volume (PTV2) and 1 cm margin around elective nodes for secondary planning target volume (PTV1) resulting in PTV1 volumes larger than 1000 cm3 in 13 of the 15 patients. Tomotherapy plans were created using an inverse treatment planning system (TomoTherapy Inc.) based on superposition/convolution dose calculation for a fan beam thickness of 25 mm and a pitch factor between 0.3 and 0.8. For comparison, plans were created using an intensity-modulated radiation therapy (IMRT) approach planned on a commercial treatment planning system (TheraplanPlus, Nucletron). Tomotherapy delivery times for the large target volumes were estimated to be between 4 and 19 min. Using a prescribed dose of 60 Gy to PTV2 and 46 Gy to PTV1, the mean lung dose was 23.8+/-4.6 Gy. A 'dose quality factor' was introduced to correlate the plan outcome with patient specific parameters. A good correlation was found between the quality of the HT plans and the IMRT plans with HT being slightly better in most cases. The overlap between lung and PTV was found to be a good indicator of plan quality for HT. The mean lung dose was found to increase by approximately 0.9 Gy per percent overlap volume. Helical tomotherapy planning resulted in highly conformal dose distributions. It allowed easy achievement of two different dose levels in the target simultaneously. As the overlap between PTV and lung volume is a major predictor of mean lung dose, future work will be directed to control of margins. Work is underway to investigate the possibility of breath-hold techniques for tomotherapy delivery to facilitate this aim.

Carcinoma, Non-Small-Cell Lung↗