Assessment of external fixator reusability using load- and cycle-dependent tests.

No standard method has been established for investigating repeated use of an external fixator. The purpose of the current study was to establish a fatigue testing method for assessing fixator frame reuse. A unilateral DynaFix trade mark external fixator system was tested using high-load and low-cycle (900-150 N at 5 Hz) and low-load and high-cycle (450-100 N at 10 Hz) tests (assumed one use of 500,000 and 1 million cycles, respectively). These loading conditions were selected to simulate single clinical use and to satisfy Food and Drug Administration requirements. In the high-load low-cycle test, substantial failure of the serrated joint occurred before completion of the first simulated use. In the low-load high-cycle test, all fixators completed three simulated clinical uses without failure, although (1/4) of the serrated joint components had hairline cracks. The high-load low-cycle test identified the fixator components which should be examined and replaced if reuse of the fixator is to be considered. Wear and deformation of the set screw on the rotary joint and telescoping mechanisms were observed in the low-load high-cycle test but not in the high-load low-cycle test. Therefore, if the unilateral DynaFix trade mark fixators are being considered for reusability, the number of reuses should be limited as the whole structure of the device will experience fatigue damage as the loading cycle increases.

Analysis of Variance↗

Tibial interface wear in retrieved total knee components and correlations with modular insert motion.

BACKGROUND: Wear occurring at the interface between the polyethylene insert and metal baseplate of a modular tibial component has become an increasingly common finding at the time of revision total knee arthroplasty. Although this so-called backside wear on retrieved polyethylene inserts has been evaluated in prior studies, wear on retrieved metal baseplates has not been described, to our knowledge. The purposes of the present study were to characterize backside wear on retrieved polyethylene inserts and on the mating surfaces of their corresponding baseplates and to investigate if there is a relationship between backside wear and relative motion of the modular elements. METHODS: Twenty-nine retrieved modular tibial components of twelve fixed-bearing designs were analyzed in vitro with regard to backside wear and relative motion between the polyethylene insert and the metal baseplate. We graded the backside of each polyethylene insert and the mating surface of the metal baseplate for wear with use of a scoring system that consisted of three modes of wear and three levels of severity of wear. Relative motion between the insert and the baseplate was measured in the transverse plane with use of a mechanical testing machine. These measurements were used to compute the insert motion index, which served to quantify unrestricted motion of the insert with respect to the baseplate. RESULTS: The mean insert motion index for the tibial components was 416 micro m (range, 104 micro m to 760 micro m). On a wear-grading scale ranging from 0 to 54 (with 0 indicating no wear), the mean backside wear score was 30 (range, 12 to 48) for the inserts and 28 (range, 7 to 51) for the baseplates. Insert motion was positively correlated with backside polyethylene wear (p = 0.003) and baseplate wear (p < 0.001). Baseplate wear was strongly correlated with backside polyethylene wear (p < 0.001). CONCLUSIONS: Backside wear was correlated with the relative motion between the polyethylene insert and the metal baseplate. New locking mechanism designs directed toward better methods of securing the polyethylene insert to the tibial tray are needed to minimize the generation of particulate wear debris at the modular interface.

Adult↗