PubMed Health⌕ Search

Biomedical subjects

Song-I Han

Publications and source records attributed to Song-I Han.

9 recordsLinked to original sources

DURABLE: A Workflow for Determining Corrosion-Driving and Protective Microbial Mechanisms.

Microbiologically influenced corrosion (MIC) threatens global infrastructure, causing billions of dollars in annual losses. Its persistence stems from unresolved mechanisms─particularly the metabolites produced by microorganisms that drive or inhibit corrosion─and the microbial community structures. Progress has been hindered by the absence of systematic workflows to rapidly and accurately identify MIC-relevant microorganisms and their functions. Here, we present DURABLE (Detection of Unique Corrosion Resistant or Accelerating Biologics in a Laboratory Environment), a pipeline that couples high-throughput microbial screening with genomic and metabolic workflows. We applied the DURABLE workflow to six diesel tank samples and revealed fuel-dependent microbial community structures, which showed greater diversity and evenness in bacterial communities than their fungal counterparts. The workflow used carbon steel beads to rapidly screen over 80 bacterial isolates for corrosive activity, reducing assay time to approximately 2 days compared with the conventional 30-day metal coupon test. More than 40 isolates were identified as corrosive. Further testing using mass spectrometry analysis revealed corrosion-associated metabolites, which were further validated using electrochemical assays. Thus, DURABLE achieved a ∼15-fold increase in screening speed and provided a scalable and mechanistic framework for dissecting MIC dynamics. We expect this advance will enable the development of precision mitigation strategies in hydrocarbon fuel infrastructure.

Bacteria↗

Sensitivity enhancement by exchange mediated magnetization transfer of the xenon biosensor signal.

Hyperpolarized xenon associated with ligand derivatized cryptophane-A cages has been developed as a NMR based biosensor. To optimize the detection sensitivity we describe use of xenon exchange between the caged and bulk dissolved xenon as an effective signal amplifier. This approach, somewhat analogous to 'remote detection' described recently, uses the chemical exchange to repeatedly transfer spectroscopic information from caged to bulk xenon, effectively integrating the caged signal. After an optimized integration period, the signal is read out by observation of the bulk magnetization. The spectrum of the caged xenon is reconstructed through use of a variable evolution period before transfer and Fourier analysis of the bulk signal as a function of the evolution time.

Algorithms↗

NMR velocity mapping of gas flow around solid objects.

We present experimental visualizations of gas flow around solid blunt bodies by NMR imaging. NMR velocimetry is a model-free and tracer-free experimental means for quantitative and multi-dimensional flow visualization. Hyperpolarization of (129)Xe provided sufficient NMR signal to overcome the low density of the dilute gas phase, and its long coherence time allows for true velocity vector mapping. In this study, the diverging gas flow around and wake patterns immediately behind a sphere could be vectorally visualized and quantified. In a similar experiment, the flow over an aerodynamic model airplane body revealed a less disrupted flow pattern.

Journal Article↗

SQUID-detected microtesla MRI in the presence of metal.

In magnetic resonance imaging performed at fields of 1 T and above, the presence of a metal insert can distort the image because of susceptibility differences within the sample and modification of the radiofrequency fields by screening currents. Furthermore, it is not feasible to perform nuclear magnetic resonance (NMR) spectroscopy or acquire a magnetic resonance image if the sample is enclosed in a metal container. Both problems can be overcome by substantially lowering the NMR frequency. Using a microtesla imaging system operating at 2.8 kHz, with a superconducting quantum interference device as the signal detector, we have obtained distortion-free images of a phantom containing a titanium bar and three-dimensional images of an object enclosed in an aluminum can; in both cases high-field images are inaccessible.

Aluminum↗

Microfluidic gas-flow profiling using remote-detection NMR.

We have used nuclear magnetic resonance (NMR) to obtain spatially and temporally resolved profiles of gas flow in microfluidic devices. Remote detection of the NMR signal both overcomes the sensitivity limitation of NMR and enables time-of-flight measurement in addition to spatially resolved imaging. Thus, detailed insight is gained into the effects of flow, diffusion, and mixing in specific geometries. The ability for noninvasive measurement of microfluidic flow, without the introduction of foreign tracer particles, is unique to this approach and is important for the design and operation of microfluidic devices. Although here we demonstrate an application to gas flow, extension to liquids, which have higher density, is implicit.

Diffusion↗

NMR-based biosensing with optimized delivery of polarized 129Xe to solutions.

Laser-enhanced (LE) 129Xe nuclear magnetic resonance (NMR) is an exceptional tool for sensing extremely small physical and chemical changes; however, the difficult mechanics of bringing polarized xenon and samples of interest together have limited applications, particularly to biological molecules. Here we present a method for accomplishing solution 129Xe biosensing based on flow (bubbling) of LE 129Xe gas through a solution in situ in the NMR probe, with pauses for data acquisition. This overcomes fundamental limitations of conventional solution-state LE 129Xe NMR, e.g., the difficulty in transferring hydrophobic xenon into aqueous environments, and the need to handle the sample to refresh LE 129Xe after an observation pulse depletes polarization. With this new method, we gained a factor of >100 in sensitivity due to improved xenon transfer to the solution and the ability to signal average by renewing the polarized xenon. Polarized xenon in biosensors was detected at very low concentrations, </=250 nanomolar, while retaining all the usual information from NMR. This approach can be used to simultaneously detect multiple sensors with different chemical shifts and is also capable of detecting signals from opaque, heterogeneous samples, which is a unique advantage over optical methods. This general approach is adaptable for sensing minute quantities of xenon in heterogeneous in vitro samples, in miniaturized devices and should be applicable to certain in-vivo environments.

Biosensing Techniques↗

Bimetallic anilido-aldimine zinc complexes for epoxide/CO2 copolymerization.

Acyclic o-phenylene-bridged bis(anilido-aldimine) compounds, o-C(6)H(4){C(6)H(2)R(2)N=CH-C(6)H(4)-(H)N(C(6)H(3)R'(2))}(2) and related 30-membered macrocyclic compounds, o-C(6)H(4){C(6)H(2)R'(2)N=CH-C(6)H(4)-(H)N-C(6)H(2)R(2)}(2) (o-C(6)H(4)) are prepared. Successive additions of Me(2)Zn and SO(2) gas to the bis(anilido-aldimine) compounds afford quantitatively dinuclear mu-methylsulfinato zinc complexes, o-C(6)H(4){(C(6)H(2)R(2)N=CH-C(6)H(4)-N(C(6)H(3)R'(2))-kappa(2)-N,N)Zn(mu-OS(O)Me)}(2) (R = iPr and R' = iPr, 29; R = Et and R' = Et, 30; R = Me and R'= Me, 31; R = Me and R' = iPr, 32; R = Et and R' = Me, 33; R = Et and R' = iPr, 34; R = iPr and R' = Et, 35) and o-C(6)H(4){C(6)H(2)R'(2)N=CH-C(6)H(4)-N-C(6)H(2)R(2)-kappa(2)-N,N)Zn(mu-OS(O)Me)}(2) (o-C(6)H(4)) (R = Et and R'= Et, 36; R = Me and R' = Me, 37; R = iPr and R' = Me, 38; R = Et and R' = Me, 39; R = Me and R'= iPr, 40). Molecular structures of 34 and 40 are confirmed by X-ray crystallography. Complexes 30-35 show high activity for cyclohexene oxide/CO(2) copolymerization at low [Zn]/[monomer] ratio (1:5600), whereas the complex of mononucleating beta-diketiminate {[(C(6)H(3)Et(2))N=C(Me)CH=C(Me)N(C(6)H(3)Et(2))]Zn(mu-OS(O)Et)}(2) shows negligible activity in the same condition. Activity is sensitive to the N-aryl ortho substituents and the highest activity is observed with 32. Turnover number up to 2980 and molecular weight (M(n)) up to 284 000 are attained with 32 at such a highly diluted condition as [Zn]/[monomer] = 1:17 400. Macrocyclic complexes 36-40 show negligible activity for copolymerization.

Journal Article↗

Remotely detected high-field MRI of porous samples.

Remote detection of NMR is a novel technique in which an NMR-active sensor surveys an environment of interest and retains memory of that environment to be recovered at a later time in a different location. The NMR or MRI information about the sensor nucleus is encoded and stored as spin polarization at the first location and subsequently moved to a different physical location for optimized detection. A dedicated probe incorporating two separate radio frequency (RF)-circuits was built for this purpose. The encoding solenoid coil was large enough to fit around the bulky sample matrix, while the smaller detection solenoid coil had not only a higher quality factor, but also an enhanced filling factor since the coil volume comprised purely the sensor nuclei. We obtained two-dimensional (2D) void space images of two model porous samples with resolution less than 1.4 mm2. The remotely reconstructed images demonstrate the ability to determine fine structure with image quality superior to their directly detected counterparts and show the great potential of NMR remote detection for imaging applications that suffer from low sensitivity due to low concentrations and filling factor.

Environmental Monitoring↗

Amplification of xenon NMR and MRI by remote detection.

A technique is proposed in which an NMR spectrum or MRI is encoded and stored as spin polarization and is then moved to a different physical location to be detected. Remote detection allows the separate optimization of the encoding and detection steps, permitting the independent choice of experimental conditions and excitation and detection methodologies. In the initial experimental demonstration of this technique, we show that taking dilute 129Xe from a porous sample placed inside a large encoding coil and concentrating it into a smaller detection coil can amplify NMR signal. In general, the study of NMR active molecules at low concentration that have low physical filling factor is facilitated by remote detection. In the second experimental demonstration, MRI information encoded in a very low-field magnet (4-7 mT) is transferred to a high-field magnet (4.2 T) to be detected under optimized conditions. Furthermore, remote detection allows the utilization of ultrasensitive optical or superconducting quantum interference device detection techniques, which broadens the horizon of NMR experimentation.

Lasers↗