PubMed Health⌕ Search

Biomedical subjects

Soo-Hong Lee

Publications and source records attributed to Soo-Hong Lee.

5 recordsLinked to original sources

Synthetic biomimetic hydrogels incorporated with ephrin-A1 for therapeutic angiogenesis.

Eph receptors and ephrin ligands are essential for vascular development and angiogenic remodeling. In this work, we developed biomimetic poly(ethylene glycol)-diacrylate hydrogels incorporated with ephrin-A1 and examined their angiogenic properties. Ephrin-A1 was covalently immobilized on the surface of hydrogels by chemical modification and photopolymerization. Ephrin-A1 immobilized on hydrogels was found to retain its capacity to stimulate endothelial cell adhesion in a dose-dependent manner as similar findings were observed on polystyrene culture wells pre-adsorbed with ephrin-A1. Cell adhesion stimulated by ephrin-A1 was abolished by treatment with soluble RGDS and anti-alpha(v)beta3 integrin but not anti-alpha(v)beta5 integrin antibodies, suggesting that ephrin-A1 activates cell adhesion through alpha(v)beta3 integrins. Also, surface immobilized ephrin-A1 was found to induce endothelial tubule formation with luminal diameters ranging 5-30 microm on hydrogels. The results of these studies demonstrate that pro-angiogenic properties of ephrin-A1 are preserved in hydrogels and suggest potential applications of this hydrogel system in regenerative medicine and tissue engineering.

Biocompatible Materials↗

Thermally produced biodegradable scaffolds for cartilage tissue engineering.

A novel process was developed to fabricate biodegradable polymer scaffolds for tissue engineering applications, without using organic solvents. Solvent residues in scaffolds fabricated by processes involving organic solvents may damage cells transplanted onto the scaffolds or tissue near the transplantation site. Poly(L-lactic acid) (PLLA) powder and NaCl particles in a mold were compressed and subsequently heated at 180 degrees C (near the PLLA melting temperature) for 3 min. The heat treatment caused the polymer particles to fuse and form a continuous matrix containing entrapped NaCl particles. After dissolving the NaCl salts, which served as a porogen, porous biodegradable PLLA scaffolds were formed. The scaffold porosity and pore size were controlled by adjusting the NaCl/PLLA weight ratio and the NaCl particle size. The characteristics of the scaffolds were compared to those of scaffolds fabricated using a conventional solvent casting/particulate leaching (SC/PL) process, in terms of pore structure, pore-size distribution, and mechanical properties. A scanning electron microscopic examination showed highly interconnected and open pore structures in the scaffolds fabricated using the thermal process, whereas the SC/PL process yielded scaffolds with less interconnected and closed pore structures. Mercury intrusion porosimetry revealed that the thermally produced scaffolds had a much more uniform distribution of pore sizes than the SC/PL process. The utility of the thermally produced scaffolds was demonstrated by engineering cartilaginous tissues in vivo. In summary, the thermal process developed in this study yields tissue-engineering scaffolds with more favorable characteristics, with respect to, freedom from organic solvents, pore structure, and size distribution than the SC/PL process. Moreover, the thermal process could also be used to fabricate scaffolds from polymers that are insoluble in organic solvents, such as poly(glycolic acid). Cartilage tissue regenerated from thermally produced PLLA scaffold.

Animals↗

Elastic biodegradable poly(glycolide-co-caprolactone) scaffold for tissue engineering.

Cyclic mechanical strain has been demonstrated to enhance the development and function of engineered smooth muscle (SM) tissues, and it would be necessary for the development of the elastic scaffolds if one wishes to engineer SM tissues under cyclic mechanical loading. This study reports on the development of an elastic scaffold fabricated from a biodegradable polymer. Biodegradable poly(glycolide-co-caprolactone) (PGCL) copolymer was synthesized from glycolide and epsilon-caprolactone in the presence of stannous octoate as catalyst. The copolymer was characterized by (1)H-NMR, gel permeation chromatography and differential scanning calorimetry. Scaffolds for tissue engineering applications were fabricated from PGCL copolymer using the solvent-casting and particle-leaching technique. The PGCL scaffolds produced in this fashion had open pore structures (average pore size = 250 microm) without the usual nonporous skin layer on external surfaces. Mechanical testing revealed that PGCL scaffolds were far more elastic than poly(lactic-co-glycolic acid) (PLGA) scaffolds fabricated using the same method. Tensile mechanical tests indicated that PGCL scaffolds could withstand an extension of 250% without cracking, which was much higher than withstood by PLGA scaffolds (10-15%). In addition, PGCL scaffolds achieved recoveries exceeding 96% at applied extensions of up to 230%, whereas PLGA scaffolds failed (cracked) at an applied strain of 20%. Dynamic mechanical tests showed that the permanent deformation of the PGCL scaffolds in a dry condition produced was less than 4% of the applied strain, when an elongation of 20% at a frequency of 1 Hz (1 cycle per second) was applied for 6 days. Moreover, PGCL scaffolds in a buffer solution also had permanent deformations less than 5% of the applied strain when an elongation of 10% at a frequency of 1 Hz was applied for 2 days. The usefulness of the PGCL scaffolds was demonstrated by engineering SM tissues in vivo. This study shows that the elastic PGCL scaffolds produced in this study could be used to engineer SM-containing tissues (e.g. blood vessels and bladders) in mechanically dynamic environments.

Absorbable Implants↗

Proteolytically degradable hydrogels with a fluorogenic substrate for studies of cellular proteolytic activity and migration.

We have developed proteolytically degradable hydrogels with covalently immobilized fluorogenic protease substrates to visualize extracellular proteolytic activity and cell migration in three dimensions. Dye quenched-bovine serum albumin (DQ-BSA), a quenched, proteolytically activated fluorogenic substrate, was conjugated to poly(ethylene glycol) (PEG)-monoacrylate, and the product (DQ-BSA-PEG) was then covalently incorporated into proteolytically degradable and cell adhesive PEG hydrogels via photopolymerization. The DQ-BSA-PEG substrate in solution and incorporated into hydrogels exhibited significantly enhanced fluorescence after exposure to enzymes. Fibroblasts seeded within this hydrogel spread in three dimensions and extended lamellipodia. Cell migration and proteolytic activity were visualized using confocal microscopy. Proteolytic activity was concentrated near cell surfaces and remained present in the tracks where cell migration had occurred.

Animals↗

Influence of implant abutment type on stress distribution in bone under various loading conditions using finite element analysis.

PURPOSE: The purpose of this study was to investigate the effect of 3 different abutment types on the stress distribution in bone with inclined loads using finite element analysis. MATERIALS AND METHODS: The 1-body, internal-hex, and external-hex implant systems were modeled to study the effect of abutment type on stress distribution in bone. The bone model used in this study comprised compact and spongious bone assumed to be homogeneous, isotropic, and linearly elastic. RESULTS: In the case of the 1-piece implant, the load was transferred evenly not only in the implant system but also in bone. However, the maximum Von Mises stress generated in bone with the 1-piece implant was always higher than that generated with the internal-hex implant, regardless of load angle inclination. In the case of the internal-hex implant, the contact condition with friction between abutment and implant in the tapered joints and at abutment neck reduced the effect of bending caused by horizontal component of inclined load. The maximum Von Mises stress in bone was the highest for the external-hex implant. DISCUSSION: It was found that the internal-hex implant system generated the lowest maximum Von Mises stresses for all loading conditions because of reduction of the bending effect by sliding in the tapered joints between the implant and abutment. CONCLUSIONS: It was concluded that abutment type has significant influence on the stress distribution in bone because of different load transfer mechanisms and the differences in size of the contact area between the abutment and implant.

Alveolar Process↗