PubMed Health⌕ Search

Biomedical subjects

Sorin Blendea

Publications and source records attributed to Sorin Blendea.

3 recordsLinked to original sources

Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching.

This study presents a clinical validation of postoperative measurements of acetabular cup alignment following total hip arthroplasty (THA). The methodology was based on concurrent anatomic three-dimensional (3D) measurements of both the acetabular cup alignment and pelvic orientation, using an original CT/X-ray matching algorithm named Xalign. The subjects were 19 patients who had undergone bilateral THA using CT-based surgical navigation. All patients had postoperative pelvic CT scans and multiple antero-posterior (AP) pelvic X-rays. Using a proprietary software algorithm, the X-rays included in the study were matched with the corresponding postoperative CT scans. The goal of this method was to allow 3D anatomic pelvic and acetabular measurements on two-dimensional AP X-rays. The postoperative cup abduction, version and pelvic flexion angles were determined in three different ways: using CT images directly, applying the Xalign method, and finally by performing conventional (abduction only) measurements on AP pelvic X-rays. The cup orientation measured on CT images was taken as the ground truth. The Xalign measurement errors were defined as the difference between the CT cup values and those obtained by applying the matching method. The mean cup abduction error was 0.85 degrees +/- 1.3 degrees (+/- standard deviation) and the mean version error was 0.01 degrees +/- 1.99 degrees . Conventionally measured cup abduction ranged from 44 degrees to 62 degrees and correlated significantly (p = 0.001, r = -0.5) with pelvic flexion angle, proving the linear negative correlation between pelvic flexion and the error in conventional radiographic cup measurements. The Xalign method offered reasonable accuracy for cup orientation, and allowed cup and pelvic 3D anatomic measurements at different times.

Acetabulum↗

Computer-assisted orthopaedic surgery: minimally invasive hip and knee reconstruction.

Joint reconstructive surgery is experiencing new and important developments. Less and minimally invasive techniques for hip and knee replacement have been described recently by several investigators. They have outlined not only the positive aspects, but also some of the difficult challenges. Accuracy and safety of the surgery could be increased, despite the smaller approaches, with navigation tools. Although promising,the initial clinical experience is limited and needs to be supported by further, prospective analysis.

Arthroplasty, Replacement, Hip↗

Less invasive total hip arthroplasty using navigational tools.

Although traditional total hip arthroplasty offers good visualization of bony landmarks and allows for the accurate orientation and fixation of implants, these benefits are achieved at the expense of extensive soft-tissue dissection and can result in postoperative complications and a delayed return to full function. To address these disadvantages, navigational tools were coupled with a mini-incision technique that allowed accurate bone preparation and orientation of the implant components without direct visualization of the bony landmarks. Additionally, image-guided systems provide three-dimensional information before and during surgery, making it possible to know, in real time, the orientation of implants and to visualize the full bony anatomy. This "computer-enhanced vision" allows surgeons to perform less invasive and eventually minimally invasive total hip arthroplasty with improved accuracy.

Arthroplasty, Replacement, Hip↗