PubMed Health⌕ Search

Biomedical subjects

Spyros Karampekios

Publications and source records attributed to Spyros Karampekios.

7 recordsLinked to original sources

Dosimetric characteristics of a 16-slice computed tomography scanner.

Standard CT dose measurements were performed on a Siemens Sensation 16 scanner. CT dose indices, free-in-air (CTDI(F)) and weighted (CTDI(W)), were measured in all available axial and helical beam collimations of the head and body scanning modes. The effect of tube current, high voltage, rotation time, beam collimation and pitch on the CT doses was investigated. CT doses increased as a power function of high voltage. The kVp exponent n varied with beam collimation from 2.7 to 3.1 for CTDI(W), and from 2.4 to 2.6 for CTDI(F). Automatic change of the focal spot size increased radiation doses up to a factor of 1.18. Measured small-focus CTDI(W) values differed from those displayed at the console from -24 to 14%. Peripheral doses in the head phantom were higher compared to the body phantom by a factor of 1.5 to 2. Central doses are 2.7 to 4.1 times higher. Differences in beam collimation resulted in 50% variation in the CTDI(W) in the body phantom and 60% in the head phantom. In conclusion, our study has confirmed the great impact of technique factors and acquisition parameters on CT doses. The provided comprehensive dosimetric data will facilitate the dose-effective use of the scanner studied.

Computer Simulation↗

Fractional anisotropy and mean diffusivity measurements on normal human brain: comparison between low-and high-resolution diffusion tensor imaging sequences.

Non-invasive in vivo visualization of white matter fiber tracts is currently feasible by means of diffusion tensor imaging (DTI) techniques. DTI-derived metrics, like fractional anisotropy (FA) and mean diffusivity (MD), have the potential to improve tissue characterization. Technical optimization of diffusion tensor sequences, including signal-to-noise ratio and spatial resolution, was performed for 20 normal subjects. High- and low-resolution DTI sequences were applied on all subjects and FA, MD parametric maps were reconstructed for both protocols. Voxel-based statistical analysis revealed regions with significantly different FA and MD values between the two sequences, while the same type of analysis was performed to illustrate regions with significantly different signal-to-noise ratio. In conclusion, optimized DTI sequences may be applied routinely in clinical practice with a standard MR scanner, while accurate quantification of FA and MD may improve lesion characterization.

Adolescent↗

Quantification of magnetization transfer rate and native T1 relaxation time of the brain: correlation with magnetization transfer ratio measurements in patients with multiple sclerosis.

The purpose of this paper is to perform quantitative measurements of the magnetization transfer rate (Kfor) and native T1 relaxation time (T1free) in the brain tissue of normal individuals and patients with multiple sclerosis (MS) by means of multiple gradient echo acquisitions, and to correlate these measurements with the magnetization transfer ratio (MTR). Quantitative magnetization transfer imaging was performed in five normal volunteers and 12 patients with relapsing-remitting MS on a 1.5 T magnetic resonance (MR) scanner. The T1 relaxation time under magnetization transfer irradiation (T1sat) was calculated by means of fitting the signal intensity over the flip angle in several 3D spoiled gradient echo acquisitions (3 degrees , 15 degrees , 30 degrees , and 60 degrees ), while a single acquisition without MT irradiation (flip angle of 3 degrees ) was utilized to calculate the MTR. The Kfor and T1free constants were quantified on a pixel-by-pixel basis and parametric maps were reconstructed. We performed 226 measurements of Kfor, T1free, and the MTR on normal white matter (NWM) of healthy volunteers (n=50), and normal-appearing white matter (NAWM) and pathological brain areas of MS patients (n=120 and 56, respectively). Correlation coefficients between Kfor-MTR, T1free-MTR, and T1free-Kfor were calculated. Lesions were classified, according to their characteristics on T1-weighted images, into isointense (compared to white matter), mildly hypointense (showing signal intensity lower than white matter and higher than gray matter), and severely hypointense (revealing signal intensity lower than gray matter). "Dirty" white matter (DWM) corresponded to areas with diffused high signal, as identified on T2-weighted images. Strong correlation coefficients were obtained between MTR and Kfor for all lesions studied (r2=0.9, p<0.0001), for mildly hypointense plaques (r2=0.82, p<0.0001), and for DWM (r2=0.78, p=0.0007). In contrast, comparison between MTR and T1free values yielded rather low correlation coefficients for all groups assessed. In severely hypointense lesions, an excellent correlation was found between Kfor and T1free measurements (r2=0.98, p<0.0001). Strong correlations between Kfor and T1free were found for the rest of the subgroups, except for the NAWM, in which a moderate correlation was obtained (r2=0.5, p<0.0001). We conclude that Kfor and T1free measurements are feasible and may improve our understanding of the pathological brain changes that occur in MS patients.

Adult↗

Scleredema adultorum of Buschke presenting as periorbital edema: a diagnostic challenge.

Scleredema adultorum is a rare sclerotic disorder characterized by diffuse swelling and nonpitting induration of the skin. Its occurrence has been documented in association with infections, diabetes mellitus, paraproteinemia, multiple myeloma, and monoclonal gammopathy. We report an unusual case of a 48-year-old man with an asymptomatic bilateral eyelid edema of sudden onset. During a period of 6 months, the condition slowly progressed to extensive nonpitting edematous swelling restricted to the periorbital sites. The presumptive diagnosis of scleredema adultorum was confirmed by the presence of typical histologic findings. This case is unique in that the periorbital swelling remained as the sole clinical manifestation of scleredema during the 5-year follow-up and was complicated with partial vision blockage.

Collagen↗

Cerebral infections.

Despite the development of many effective antibiotic therapies and the general improvement in hygiene and health care systems all over the world, the incidence of central nervous system (CNS) infection has increased significantly in the past 15 years. This can be attributed primarily to the acquired immunodeficiency syndrome (AIDS) epidemic and its devastating effect on the immune system and secondarily to various immunosuppressive agents that are being used in aggressive cancer treatment and in organ transplantations. The brain particularly is protected from infection by the calvarium, meninges and blood brain barrier. However, different types of pathogens, including bacteria, viruses, fungi and parasites, can reach the brain hematogenously or, less likely, by direct extension from an adjacent infected focus. The early detection and specific diagnosis of infection are of great importance, since brain infections are potentially treatable diseases. Imaging studies play a crucial role in the diagnostic process, along with the history (exposure to infectious agents), host factors (open head trauma, CSF leak, sinusitis, otitis, immune status), physical examination and laboratory analysis of CSF.

Acquired Immunodeficiency Syndrome↗

Stereological estimation of total intracranial volume on CT images.

This study aims to investigate the possibility of generating stereological estimations of total intracranial volume (TIV) on CT scans. The study group included 16 consecutive patients referred for a cranial CT examination. The TIV was estimated using the stereological point counting technique. Volume measurements were optimized by systematically sampling CT sections and by defining an optimum spacing between test points of the grid. The intraobserver and interobserver variability of the optimized volumetric technique was determined. Stereological TIV estimations were compared with the respective planimetric measurements. The application of a test grid with a point spacing of 2.4 cm on 6-8 systematically sampled CT sections provided TIV estimations with a coefficient of error of less than 5%. The intraobserver and interobserver coefficient of variation values were found to be 2.4 and 4.0%, respectively. The 95% limits of agreement between stereological and planimetric TIV measurements were equal to -91.4 and 103.4 cm3. The mean time (+/- SD) needed to obtain stereological TIV estimations was 2.9 +/- 0.6 min. The application of the optimized stereological technique on CT scans enables the efficient estimation of TIV.

Aged↗

T2 relaxation time analysis in patients with multiple sclerosis: correlation with magnetization transfer ratio.

The aim of the current study was to perform T2 relaxation time measurements in multiple sclerosis (MS) patients and correlate them with magnetization transfer ratio (MTR) measurements, in order to investigate in more detail the various histopathological changes that occur in lesions and normal-appearing white matter (NAWM). A total number of 291 measurements of MTR and T2 relaxation times were performed in 13 MS patients and 10 age-matched healthy volunteers. Measurements concerned MS plaques (105), NAWM (80), and "dirty" white matter (DWM; 30), evenly divided between the MS patients, and normal white matter (NWM; 76) in the healthy volunteers. Biexponential T2 relaxation-time analysis was performed, and also possible linearity between MTR and mean T2 relaxation times was evaluated using linear regression analysis in all subgroups. Biexponential relaxation was more pronounced in "black-hole" lesions (16.6%) and homogeneous enhancing plaques (10%), whereas DWM, NAWM, and mildly hypointense lesions presented biexponential behavior with a lower frequency(6.6, 5, and 3.1%, respectively). Non-enhancing isointense lesions and normal white matter did not reveal any biexponential behavior. Linear regression analysis between monoexponential T2 relaxation time and MTR measurements demonstrated excellent correlation for DWM( r=-0.78, p<0.0001), very good correlation for black-hole lesions( r=-0.71, p=0.002), good correlation for isointense lesions( r=-0.60, p=0.005), moderate correlation for mildly hypointense lesions( r=-0.34, p=0.007), and non-significant correlation for homogeneous enhancing plaques, NAWM, and NWM. Biexponential T2 relaxation-time behavior is seen in only very few lesions (mainly on plaques with high degree of demyelination and axonal loss). A strong correlation between MTR and monoexponential T2 values was found in regions where either inflammation or demyelination predominates; however, when both pathological conditions coexist, this linear relationship is lost.

Adolescent↗