Images in clinical medicine. Salt-and-pepper retinopathy of rubella.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Srinivas R Sadda.
Explore the source record for details and available documents.
Stimulus threshold and response latencies were measured for electrically elicited retinal ganglion cell responses in retina isolated from the eyes of normal and retinal degenerate (rd1) mice. Stimulation of the ganglion cell-side in normal retina yielded a significantly lower mean threshold and shorter latency when compared with stimulation of the photoreceptor side in normal retina. The latency of the ganglion cell-side stimulation in normal retina also proved to be significantly shorter than the latency for stimulation of the ganglion cell side in rd1 retina. Thus both the electrode positioning as well as the health of the retinal tissue play a role in the stimulating current required to elicit a retinal response.
OBJECTIVE: To compare the detection of clinically significant diabetic macular edema (DME) by an optical coherence tomography (OCT) grid scanning protocol and biomicroscopic examination. DESIGN: Retrospective case series. PARTICIPANTS: Outpatients at the Doheny Eye Institute. METHODS: The clinical and imaging records of a consecutive series of 71 eyes of 40 patients referred for DME who underwent OCT using the both the Macular Grid 5 (MG5) scanning protocol (to allow a more evenly distributed sampling of points in the macula) and the standard Fast Macular Thickness Map (FMTM) pattern were reviewed. An automated algorithm was developed to generate a retinal thickness map using the MG5 data, which was then compared with a normative database to identify presumed areas of retinal edema. Clinically significant macular edema (CSME) was also identified by clinical examination and stereoscopic fundus photographs for comparison with the results of the OCT protocols. MAIN OUTCOME MEASURES: Sensitivity and specificity of scanning protocols. RESULTS: Optical coherence tomograms were inspected visually, and automatically detected retinal boundaries were found to be correct in 69 of 71 MG5 scans and in 65 of 71 FMTM scans. Macular Grid 5 scanning was performed twice in each eye, and the repeatability (pooled standard deviation) of the total area of edema was 0.48 mm2 (coefficient of variation, 6.8%). Sensitivity and specificity of the MG5 for detection of CSME relative to the clinical examination were 89% and 86%, respectively, with kappa being 0.74. Macular Grid 5 and FMTM assessment of foveal CSME also showed good agreement, with kappa being 0.68. CONCLUSIONS: The analysis algorithm for the OCT MG5 grid scan seems to be accurate and repeatable. Automated detection of CSME by the MG5 analysis correlated well with the clinical grading and standard OCT analysis (FMTM). Macular Grid 5 provides more information regarding the perifoveal macula than FMTM and may be of value to clinicians in planning treatment and in future studies of macular edema.
OBJECTIVE: To report the frequency and severity of optical coherence tomography (OCT) retinal thickness measurement errors and to describe parameters that predict these errors. DESIGN: Observational case series. PARTICIPANTS: Two hundred consecutive patients undergoing OCT imaging. METHODS: One eye (primary) from each of 200 consecutive patients undergoing Stratus OCT imaging (Carl Zeiss Meditec, Dublin, CA) with radial lines or fast macular thickness-based acquisition protocols was selected for review by 2 graders. On each of the line scans, graders evaluated the position of the automated retinal boundary lines (inner retinal surface and retinal pigment epithelium band) used by the OCT machine for thickness calculations and graded the positioning on a 6-point subjective, categorical error scale to generate an error score. The presence of thickness errors was correlated with various parameters, including the analysis confidence assessment reported by the OCT software, disease diagnosis, retinal morphologic features, the foveal center thickness standard deviation (FCTSD), and the FCTSD-to-foveal center thickness (FCT) ratio. MAIN OUTCOME MEASURE: Average OCT retinal thickness error score. RESULTS: Errors of retinal boundary detection and thickness measurement were observed in 92% of eyes, but were severe in only 13.5% of eyes. The identification of an error or low analysis confidence by the OCT software was strongly associated with the severity of the retinal thickness errors. A higher FCTSD-to-FCT ratio and presence of subretinal fluid also were associated with more severe errors. Retinal cysts and a diagnosis of retinal vascular disease such as diabetic macular edema were less likely to be associated with significant errors. CONCLUSIONS: Retinal thickness measurement errors occur frequently with current OCT segmentation and analysis algorithms. Severe errors are more frequent in eyes with subretinal pathologic features, but generally are detected by the OCT software. A high FCTSD-to-FCT ratio (>0.1) also may alert the clinician to the possibility of thickness errors. Clinical studies, particularly those pertaining to subretinal diseases, should consider these errors when incorporating OCT imaging in the study design.
INTRODUCTION: To evaluate whether eyes with longer axial lengths are associated more often with clinically significant cataracts than eyes with shorter axial lengths. MATERIAL AND METHODS: Charts of consecutive patients who underwent cataract surgery by 4 resident surgeons at Los Angeles County Hospital from July 2001 through May 2002 were retrospectively reviewed. Those patients whose axial lengths were significantly different between the 2 eyes (>or=0.30 mm) and who had no pathology (other than cataracts) affecting visual acuity were included in the study. The 2 eyes in each patient were compared for preoperative best-corrected visual acuity and severity of cataracts. RESULTS: Thirty-four of 353 patients had interocular axial length differences of at least 0.3 mm and were included in this study. Thirty-one patients had worse, 1 had equal, and 2 had better preoperative vision in the eye with longer versus the shorter axial length. Fourteen patients had more severe, 11 had the same, and 1 had less severe posterior subcapsular cataract (PSC) in the eye with longer axial length. In 8 patients, PSC severity could not be assessed due to obscuring nuclear sclerosis. Twenty-four patients had more severe, 7 patients had equal, and 3 patients had less severe nuclear sclerosis in the longer eye. Overall, longer axial lengths correlated with worse visual acuity, posterior subcapsular cataracts, and nuclear sclerosis. Diabetic status did not affect the correlation. The correlations were stronger with greater axial length asymmetry. CONCLUSIONS: Eyes with longer axial lengths have a higher prevalence of cataracts.
Multi-unit visual responses to light intensities ranging from -6.46 to 0.81 logcd/m2 were recorded from the surface of the superior colliculus of dark-adapted normal pigmented and normal albino rats. Light sensitivity was significantly higher in albinos. The response onset latency was inversely proportional to the stimulus intensity. The progression of the stimulus intensity versus response onset latency curve showed a considerable difference between pigmented and albino rats. At low light levels, longer response onset latencies were recorded in pigmented rats than in albinos. This can be attributed to the transmission of rod-driven responses. The differences observed in the light response characteristics of albino rats may be indicative of their visual abnormalities.
Optical coherence tomography (OCT), a non-invasive method, was used for qualitative assessment of fetal retinal sheet transplants by non-invasive imaging. Rhodopsin-mutant S334ter-line-3 rats with fast retinal degeneration (28-37-day old) were transplanted with fetal retinal sheets from embryonic day (E) 18-19 pigmented normal rats. Retinal thickness measurements from transplanted (n = 51), no surgery control (n = 8), and normal pigmented rat eyes (n = 6) were obtained using a Zeiss stratus OCT-3 scanning instrument. Frozen retinal sections were stained with hematoxylin/eosin. S334ter-line-3 rats showed significant reduction in OCT retinal thickness (p<0.001) compared to normal pigmented rats at the age of 21 days. In 62% of the transplanted rats, OCT scanning revealed the presence of a subretinal graft, which was confirmed by subsequent histology. Retinal thickness in the transplant area was significantly increased compared to the area outside the transplant and to non-transplanted eyes (p<0.001). While most of the transplants with single-band OCT images (87%) had rosetted transplants, a considerable proportion of transplants having a multi-band OCT image were found to have well-laminated areas in the graft after histological evaluation. Following retinal transplantation in rodents, OCT imaging data correlated mostly with transplant morphology. OCT is a useful technique for in vivo screening and evaluation of retinal transplants. This technique determines surgical outcomes at a much earlier stage.
OBJECTIVE: To report the recurrence of geographic atrophy (GA) in a patient with nonexudative age-related macular degeneration (AMD) after full macular translocation. DESIGN: Observational case report. METHODS: Review of the clinical, photographic, and angiographic records of a patient with GA who underwent full macular translocation. MAIN OUTCOME MEASURES: Progression of GA. RESULTS: A 73-year-old man with GA secondary to nonexudative AMD underwent a macular translocation with 360 peripheral retinectomy (MT 360) in his left eye. On postoperative month 4, fundus photography showed subtle alterations of the pigment underneath the translocated foveal region. On postoperative month 9, the visual acuity worsened to preoperative levels and there was frank retinal pigment epithelium atrophy involving the new macular region. CONCLUSIONS: The rapid recurrence and development of GA in the translocated fovea after MT 360 raise new questions regarding the pathogenesis of GA. They also raise concerns regarding the use of MT 360 in the management of nonexudative AMD.
PURPOSE: To compare the size of subfoveal lesions based on photographic documentation before and after submacular surgery of choroidal neovascularization (CNV) lesions. METHODS: Subfoveal lesion sizes at baseline and month 3 follow-up visits for patients assigned to surgery in the Submacular Surgery Trials (SST) Pilot Study were assessed categorically using Macular Photocoagulation Study (MPS) disc area (DA) circles. The Submacular Surgery Trials Pilot Study groups reviewed were as follows: Group N (age-related macular degeneration [AMD]; lesion <50% blood; classic CNV present; size < or =9 MPS DAs); Group R (AMD; prior nonfoveal laser; classic CNV present; size < or =9 MPS DAs); Group B (AMD; lesion > or =50% blood); and Group H (ocular histoplasmosis syndrome or idiopathic; classic CNV present; size < or =9 MPS DAs). RESULTS: Postoperative month 3 lesion size was at least 1 size category smaller than the preoperative lesion size in 6% (4/66) of Group N, 0 (0/31) of Group R, 6% (2/34) of Group H, and 45% (18/40) of Group B eyes. In Group H eyes, there was no size change in 50% (17/34), and enlargement was found in 44% (15/34). For eyes in Groups N and R, approximately one third remained stable (20/66, 30% and 12/31, 39%, respectively), whereas two thirds enlarged by at least 1 category (42/66, 64% and 19/31, 61%, respectively). CONCLUSIONS: The change in lesion size after submacular surgery was variable, with a tendency for Group H lesions to remain the same size or larger, Group B lesions to measure smaller, and Group N and Group R lesions to be larger.
A variety of disease processes can affect the retina and/or the optic nerve, including vascular or ischemic disease, inflammatory or infectious disease, and degenerative disease. These disease processes may selectively damage certain parts of the retina or optic nerve, and the specific areas that are damaged may have implications for the design of potential therapeutic visual prosthetic devices. Outer retinal diseases include age-related macular degeneration, pathologic myopia, and retinitis pigmentosa. Although the retinal photoreceptors may be lost, the inner retina is relatively well-preserved in these diseases and may be a target for retinal prosthetic devices. Inner retinal diseases include retinal vascular diseases such as diabetic retinopathy, retinal venous occlusive disease, and retinopathy of prematurity. Other retinal diseases such as ocular infections (retinitis, endophthalmitis) may affect all retinal layers. Because the inner retinal cells, including the retinal ganglion cells, may be destroyed in these diseases (inner retinal or whole retinal), prosthetic devices that stimulate the inner retina may not be effective. Common optic nerve diseases include glaucoma, optic neuritis, and ischemic optic neuropathy. Because the ganglion cell nerve fibers themselves are damaged, visual prosthetics for these diseases will need to target more distal portions of the visual pathway, such as the visual cortex. Clearly, a sound understanding of retinal and optic nerve disease pathophysiology is critical for designing and choosing the optimal visual prosthetic device.
PURPOSE: To determine whether transplantation of autologous retinal pigment epithelium (RPE) will prevent atrophy of the choriocapillaris and loss of photoreceptors in an area in which the RPE has been mechanically debrided from Bruch's membrane. METHODS: Abrasive debridement of RPE was performed with a metal cannula after localized retinal bleb detachments in two separate areas of the rabbit retina. The RPE cell suspension aspirated from one of the debridement sites was transplanted to the other. The debridement-only site served as control. The transplant and control sites were evaluated after 30 days by color fundus photography, fluorescein angiography, light microscopy and transmission electron microscopy. RESULTS: Compared with debridement only, debridement plus transplantation of RPE resulted in more complete repopulation of the bare Bruch's membrane surface with relative preservation of choriocapillaris and photoreceptors. CONCLUSION: Autologous transplantation of RPE onto an abrasively debrided Bruch's membrane decreases choriocapillaris atrophy and photoreceptor loss.
Explore the source record for details and available documents.
PURPOSE: To study the functional success of neural retinal transplantation by means of retinal surface ganglion cell recordings. METHODS: Eight-week-old C3H/HeJ (rd/rd) retinal degeneration mice received transplants (subretinal) in one eye only of neural retinal tissue isolated from newborn normal C57/BL6J mice. Four weeks after transplantation, ganglion cell responses were recorded directly from the retinal surface over the transplant, with a differential bipolar surface electrode. Measurements were performed, both with and without light stimulation. Similar recordings were performed in nontransplant areas of the transplant-recipient eyes, and in age-matched sham-treated and untreated control eyes. After the recordings, the eyes were processed for light and transmission electron microscopy. RESULTS: Histologic examination showed that in some areas, transplanted cells were organized into small sheets and differentiated into photoreceptors with outer segments in intimate contact with the host RPE. No light-driven ganglion cell responses were recordable from the transplant-recipient or control eyes. However, the spontaneous ganglion cell activity was higher in the transplant areas (mean: 10.8 +/-12.0 spikes/1.6 sec) compared with nontransplant areas of these recipient eyes (mean: 2.4 +/- 5.7spikes/1.6 sec; P < 0.001), sham-treated eyes (mean: 2.5 +/- 4.8 spikes/1.6 sec; P < 0.001), and the untreated control eyes (mean: 2.2 +/- 4.4 spikes/1.6 sec; P < 0.001). CONCLUSIONS: Subretinal transplantation of neural retinal tissue results in a local increase of spontaneous ganglion cell activity. The increased activity may be due to the release of neurochemically active substances as a result of the presence of the transplant. Although light responses were not recordable, the technique of retinal surface ganglion cell recording may be useful for assessing the functional success of transplantation.