Determination of thigh muscle stiffness using magnetic resonance elastography.

PURPOSE: To measure the elastic properties of the vastus lateralis (VL), vastus medialis (VM), and sartorius (Sr) muscles using magnetic resonance elastography (MRE). MATERIALS AND METHODS: To obtain a normative database of the aforementioned muscles, oblique scan directions were prescribed passing through each muscle. Shear waves were induced into the muscles using pneumatic and mechanical drivers at 90 and 120 Hz, respectively. These drivers were attached to the distal end of the right thigh with the knee flexed at 30 degrees . The foot was placed in a footplate containing MR-compatible load cells to record the force during a contraction (10% and 20% of the maximum voluntary contraction). RESULTS: The shear moduli measured at rest in the VL (N = 12), VM (N = 14), and Sr (N = 13) were 3.73 +/- 0.85 kPa, 3.91 +/- 1.15 kPa, and 7.53 +/- 1.63 kPa, respectively. The stiffness of both vasti increased with the level of contraction, while the stiffness of the Sr remained the same. CONCLUSION: The MRE technique was able to approximate the stiffness of different thigh muscles. Furthermore, the wave length was sensitive to the morphology (unipennate or longitudinal) and fiber composition (type I or II) in each muscle.

Adult↗

Differential effects of pre-tension on shear wave propagation in elastic media with different boundary conditions as measured by magnetic resonance elastography and finite element modeling.

Magnetic resonance elastography (MRE) can non-invasively determine material stiffness based on the propagating shear wavelength. Shear wave propagation in a finite homogenous isotropic material can be affected by multiple factors. In this study we examined the effects of pre-tension and frequency on MRE shear measurements of gel phantoms with different boundary conditions, frequencies, and geometries. Results from MRE measurements were compared to wave motion theory in elastic solids and qualitatively to a finite element (FE) model. Results indicated that boundary conditions, geometry and pre-tension are important factors to be considered when performing MRE tests on a finite material, and that FE modeling can help explore how the shear wave propagation is affected under various boundary conditions and axial stresses, among other potential factors.

Biocompatible Materials↗

Quantitative shear wave magnetic resonance elastography: comparison to a dynamic shear material test.

Magnetic resonance elastography (MRE), a phase contrast MRI technique, images the propagation of applied mechanical waves in tissue, allowing shear stiffness to be quantified in vivo. This MRE technique has been validated with static mechanical compression tests. Dynamic mechanical analysis (DMA) may be a more appropriate comparison to MRE because it directly measures the shear modulus dynamically, while compression tests convert the measured elastic modulus to shear modulus with an assumed Poisson ratio. This study compared the shear stiffness estimated with various MRE inversion algorithms (i.e., manual calculation, local frequency estimate, phase gradient, direct inversion, and matched filter) to the dynamic mechanical test. The shear stiffness of five agarose gels with concentrations ranging from 1.5 to 3.5% were measured using MRE and DMA. The phase gradient inversion algorithm overestimated the shear modulus at higher concentrations (i.e., 3-3.5% agar), while the results from the other techniques correlated well with the dynamic mechanical test.

Agar↗

Identification of the testing parameters in high frequency dynamic shear measurement on agarose gels.

Dynamic mechanical analysis (DMA) on agarose gels can be used to validate magnetic resonance elastography (MRE) measurements as well as to provide better understanding for the biological responses of cells to the dynamic loadings in cell culture studies. Various parameters potentially affecting the repeatability and accuracy of the DMA shear modulus measurements were investigated systematically in the present study, including sample thickness, shear strain, testing frequency, and compressive clamping strain. The study showed that the thickness of the agarose gel sample must be sufficiently small (1 mm) to prevent the erroneous fluctuation in the measured modulus. The appropriate levels of shear strain (< or = 0.5%) and compressive clamping strain (5-10%) must be applied to overcome the slippage at the gel-clamp interface without causing significant boundary and stress non-uniformity or micro-cracks in the agarose gel sample.

Cell Culture Techniques↗

A finite element model for analyzing shear wave propagation observed in magnetic resonance elastography.

Magnetic resonance elastography (MRE) is a novel non-invasive approach to determine material stiffness by using a conventional magnetic resonance imaging (MRI) system incorporated with an oscillating motion-sensitizing gradient to detect nodal displacements produced by a shear excitation wave. The effects of material properties, excitation frequency, boundary conditions, and applied tension on shear wavelength measurement must be examined before MRE can become a useful diagnostic tool. We propose finite element (FE) modeling as a robust method to systematically study the effects of these parameters. An axisymmetric FE model was generated with ABAQUS to simulate agarose gel phantoms. The effects of material stiffness, density, and excitation frequency on propagating shear wavelength were examined individually. The effect of the boundary conditions on shear wavelength was also demonstrated. Results of shear wavelength from MRE measurement were compared with the results of FE model, which showed good agreement between the methods.

Biomechanical Phenomena↗