Pseudolinear gradient ultrahigh-pressure liquid chromatography using an injection valve assembly.

The use of ultrahigh pressures in liquid chromatography (UHPLC) imposes stringent requirements on hardware such as pumps, valves, injectors, connecting tubing, and columns. One of the most difficult components of the UHPLC system to develop has been the sample injector. Static-split injection, which can be performed at pressures up to 6900 bar (100,000 psi), consumes a large sample volume and is very irreproducible. A pressure-balanced injection valve provided better reproducibility, shorter injection time, reduced sample consumption, and greater ease of use; however, it could only withstand pressures up to approximately 1000 bar (15,000 psi). In this study, a new injection valve assembly that can operate at pressures as high as 2070 bar (30,000 psi) was evaluated for UHPLC. This assembly contains six miniature electronically controlled needle valves to provide accurate and precise volumes for introduction into the capillary LC column. It was found that sample volumes as small as several tenths of a nanoliter can be injected, which are comparable to the results obtained from the static-split injector. The reproducibilities of retention time, efficiency, and peak area were investigated, and the results showed that the relative standard deviations of these parameters were small enough for quantitative analyses. Separation experiments using the UHPLC system with this new injection valve assembly showed that this new injector is suitable for both isocratic and gradient operation modes. A newly designed capillary connector was used at a pressure as high as 2070 bar (30,000 psi).

Journal Article↗

Partial modulation method via pulsed flow modulator for comprehensive two-dimensional gas chromatography.

A partial modulation method by using a pulsed-flow modulator for comprehensive two-dimensional gas chromatography is proposed. The method is based on the fact that when a pulsed flow of inert gas is introduced into the conjunction between a primary and a secondary column, the concentration of analyte is disturbed, and a plug of higher or lower concentration is created. The plug, which forms a spike signal coupled to the primary GC signal, is then separated in a secondary column, creating a new dimension of GC information. The modulation is partial because only a fraction of the primary signal is modulated and converted into the secondary signal; the remaining primary signal stays unchanged. Therefore, this method yields a comprehensive two-dimensional chromatogram and a primary one-dimensional chromatogram in a single GC run. In this study, the modulation mode, modulation index, and modulation percentage are discussed and the reproducibility of peak areas and retention time are investigated. With a 5.8% modulation percentage and a primary peak half-width 1.7 times wider than the modulation time, the standard deviation for the peak areas are 0.15% for the primary and 0.78% for the secondary chromatograms. Chromatograms of laboratory-mixed hydrocarbons and of high-temperature fuel oil no. 6 standard are demonstrated.

Journal Article↗