PubMed Health⌕ Search

Biomedical subjects

Stefan Delorme

Publications and source records attributed to Stefan Delorme.

At least 19 recordsLinked to original sources

Contrast-enhanced ultrasound for examining tumor biology.

This paper reviews the potential of ultrasound for assessing the viability and biological behavior of tumors. Unlike color Doppler sonography, modern techniques for contrast-enhanced ultrasound permit the measurement of tissue perfusion irrespective of vessel size or flow velocity. Perfusion can also be assessed quantitatively, using replenishment kinetics or derivates thereof. The perfusion of tumors is a surrogate parameter of their viability and may mirror their response to therapy. Furthermore, the degree of vascularity in a tumor may express its aggressiveness and help to predict its response to treatment. In animal models, a decrease in blood flow has been shown to precede a shrinkage of tumors treated with anti-angiogenic compounds. In liver metastases, arterial and portal blood supply can be assessed separately, and a response to stereotactic radiotherapy was found to go along with a decrease in arterial perfusion. Moreover, a relatively high arterial perfusion of liver metastases may predict a response to chemotherapy. Contrast-enhanced ultrasound may be a potent tool for assessing the effects of anti-angiogenic treatment in patients.

Air↗

In vitro drug sensitivity predicts response and survival after individualized sensitivity-directed chemotherapy in metastatic melanoma: a multicenter phase II trial of the Dermatologic Cooperative Oncology Group.

PURPOSE: In vitro sensitivity assays are promising tools to predict the individual outcome of different chemotherapy regimens. However, a direct association between in vitro and in vivo chemosensitivity has to be shown by clinical studies. This multicenter phase II trial was aimed to investigate the efficacy of a sensitivity-directed, first-line chemotherapy in metastasized melanoma patients, and to prove an association between in vitro sensitivity and therapy outcome. PATIENTS AND METHODS: The primary study end point was objective response; secondary end points were safety, overall survival, and progression-free survival. Viable tumor cells obtained from metastatic lesions were tested for chemosensitivity to seven single drugs and five drug combinations using an ATP-based luminescence viability assay. RESULTS: Out of 82 recruited patients (intention-to-treat), 57 received assay-directed chemotherapy and 53 were evaluable for all study end points (per protocol). The drug combinations used were gemcitabine+treosulfan, paclitaxel+cisplatin, paclitaxel+doxorubicin, and gemcitabine+cisplatin. The per protocol population could be divided into 22 (42%) chemosensitive and 31 (58%) chemoresistant patients by an arbitrary chemosensitivity index. Objective response was 36.4% in chemosensitive patients compared with 16.1% in chemoresistant patients (P=0.114); progression arrest (complete response+partial response+stable disease) was 59.1% versus 22.6% (P=0.01). Chemosensitive patients showed an increased overall survival of 14.6 months compared with 7.4 months in chemoresistant patients (P=0.041). CONCLUSION: In vitro chemosensitivity testing may be worthy of further exploration to see if it could be a useful tool to predict the outcome of melanoma patients treated with a sensitivity-directed chemotherapy. Therefore, these preliminary results will be evaluated by a planned phase III trial using a randomized, standard-regimen controlled setting.

Adult↗

Age related changes of human aortic distensibility: evaluation with ECG-gated CT.

Aortic distensibility is a parameter to grade vascular diseases and age-related effects because it is related to the elastic properties of the vessel wall. In this study vascular cross-sectional area changes have been determined using ECG-gated CT to analyse the age dependency of aortic distensibility. Distensibility measurements of the aorta were performed in 31 subjects (28 to 85 years). Time-resolved images were acquired either with a 4- or 16-detector row CT system using a modified CT angiography protocol. Cross-sectional area changes of the aorta were calculated by semiautomatic segmentation, and distensibility values were obtained using additional systemic blood pressure measurements. The aorta could be segmented successfully in all subjects. A decrease of aortic distensibility with age was found (r=0.50). Below (above) the renal arteries, the annual decrease was Delta D ( infrarenal ) =(-2.1+/-0.7).10(-7 )Pa(-1)a(-1), (D ( suprarenal ) Delta=(-3.5+/-1.1).10(-7 )Pa(-1)a(-1)). Differences between the ages, the youngest third and oldest third studied, were found to be significant (P( suprarenal )=0.003; P( infrarenal )=0.025). An age-dependent decrease of aortic wall elasticity can be determined in a modified routine CT angiography study.

Adult↗

Contrast-enhanced ultrasound in dermatomyositis- and polymyositis.

OBJECTIVE: To evaluate prospectively contrast-enhanced ultrasound (CEUS) in patients suspected of having dermatomyositis or polymyositis. METHODS: In 35 patients (23 women, 12 men; mean age, 51 years+/-16 years) who were suspected of having dermatomyositis or polymyositis, perfusion in clinically affected skeletal muscles was quantified with contrast-enhanced intermittent power Doppler ultrasound. By applying a modified model that analyzed the replenishment kinetics of microbubbles, the perfusion-related parameters blood flow, local blood volume and blood flow velocity were measured. Findings were compared with muscle biopsy appearances and with the results of MRI that was performed with a 1.5-Tesla unit. Receiver operating characteristic analysis was performed and optimum thresholds for diagnosis of myositis were determined. RESULTS: Eleven patients had histologically confirmed dermatomyositis or polymyositis and showed significantly higher blood flow velocity (P=.01 for dermato- and P<.001 for polymyositis), blood flow (P<.001 for dermato- and polymyositis), and blood volume (P=.007 for dermato- and P<.001 for polymyositis) on contrast-enhanced ultrasound than those who did not have myositis. An increase in signal intensity on T2-weighted MR images was found in all patients with myositis. MRI had a sensitivity, specificity, positive (PPV), and negative predicting values (NPV) of 100%, 88%, 77%, and 100% for diagnosis of myositis, respectively. CEUS blood flow was the best ultrasound measure for diagnosis of dermato- or polymyositis with sensitivity, specificity, PPV, and NPV of 73%, 91%, 80%, and 88%, respectively. CONCLUSIONS: Increased skeletal muscle perfusion measured by CEUS could serve as an additional measurer for the diagnosis of an inflammatory myopathy.

Adult↗

Absence of tissue reaction after focal high-dose irradiation of rabbit liver.

BACKGROUND: A focal reaction of the liver is radiologically seen after stereotactic high dose radiotherapy of liver tumors. The histological counterpart of this reaction should be clarified using an animal model. MATERIALS AND METHODS: Six New Zealand white rabbits were positioned on a special stereotactic set-up. Parts of the liver (1.5-8 ml) were irradiated with either 20-24 Gy/80% (n = 3) or 36 Gy/80% (n = 3). The animals were followed by CT examination up to 2 years after radiotherapy. Finally, the animals were sacrificed and the liver macroscopically and microscopically inspected. RESULTS: No focal reaction could be observed in any liver at any time by CT examination. The liver macroscopically and microscopically showed no changes 6 months or 2 years after radiotherapy. CONCLUSION: Up to a single dose of 36 Gy/80%, rabbits seem to show no focal tissue reaction after high dose radiation therapy of small parts of the liver.

Animals↗

Relationship of skeletal muscle perfusion measured by contrast-enhanced ultrasonography to histologic microvascular density.

OBJECTIVE: The purpose of this study was to compare skeletal muscle perfusion measured by contrast-enhanced ultrasonography (CEUS) with microvascular density in muscle biopsies. METHODS: Power Doppler sonography after intravenous bolus injection of Levovist (SH U 508A; Schering AG, Berlin, Germany) was used to examine perfusion of vastus lateralis muscle in 23 healthy volunteers. Local blood volume (B), blood flow velocity (v), and blood flow (f) were calculated by analyzing replenishment kinetics. CEUS perfusion was compared with vascularization of biopsy samples from vastus lateralis muscle. Subjects were selected such that their aerobic capacity (maximal oxygen uptake [VO(2)max]) per body weight ranged between 23 and 66 mL . min(-1) . kg(-1) to render a large variability of skeletal muscle capillarization. Moreover, subjects' venous blood hematocrit (Hkt) was determined to estimate the plasmatic intravascular volume fraction (1-Hkt=PVF) in which the microbubbles can distribute. RESULTS: Median capillary density was 331/mm(2) (range, 207-469/mm(2)), and median capillary fiber contacts (CFC) were 3.6 (range, 2.3-6.5). CFC was correlated with VO(2)max (r=0.59; P<.01). Among CEUS parameters, B showed the closest correlation to CFC (r=0.53; P<.01). When CFC was normalized for PVF, correlation of B to CFC was r=0.64 (P<.01). CEUS could depict the physiologic large variability of vastus lateralis muscle perfusion at rest (median [range]: B, 2.5 [0.1-12.3] approximately mL; v, 0.3 [0.1-3.7] mm/s; f, 0.7 [0.1-5.3] approximately mL . min(-1) . 100 g tissue(-1)). CONCLUSIONS: B is significantly related to fiber-adjacent capillarization and may represent physiologic capillary recruitment (eg, through metabolic fiber-related signals). CEUS is feasible for skeletal muscle perfusion quantification.

Adult↗

Magnetic resonance blood flow measurements in the follow-up of pediatric patients with aortic coarctation - a re-evaluation.

BACKGROUND: Previous studies have suggested the feasibility of a non-invasive quantification of vascular trans-stenotic pressure gradients (DeltaP) by phase-contrast MR imaging (PC-MRI). Our purpose was to assess the value of MRI estimated pressure gradients as a screening tool for assessing hemodynamically significant (re-)coarctation of the aorta (CoA) in pediatric patients. METHODS: Forty-three patients (median age (range), 16 (5-25) years) with CoA (38 postoperative and 5 native) and clinically suspected hemodynamically significant stenosis underwent quantitative and semi-quantitative PC-MRI blood flow measurements and 3D MR-angiography, Doppler ultrasound (US) and conventional catheter angiography (CCA, n=20). Estimated DeltaP for each modality was correlated with percent stenosis. RESULTS: The percent stenosis correlated only moderately with DeltaP(MRI) (r=0.55, p<0.001) and DeltaP(CCA) (r=0.48, p<0.001). Only moderate correlations were observed between DeltaP(MRI) vs. DeltaP(CCA) (r=0.54, p=0.02) and vs. DeltaP(US) (r=0.40, p=0.01). In contrast, semi-quantitative analysis of PC-MRI flow profiles predicted with good sensitivity (88%) and specificity (88%) who would be operated on. Thirteen patients met hemodynamic and percent stenosis criteria by CCA for surgical intervention. CONCLUSION: Measured pressure gradients using PC-MRI should be used cautiously when assessing patients for recoarctation of the aorta. The analysis of blood flow profiles by PC-MRI might be a promising alternative in assessing the hemodynamic significance of CoA.

Adolescent↗

Pathologic skeletal muscle perfusion in patients with myositis: detection with quantitative contrast-enhanced US--initial results.

PURPOSE: To prospectively determine whether contrast material-enhanced ultrasonography (US) can depict inflammation-induced changes in muscle perfusion for patients suspected of having dermatomyositis or polymyositis and to compare these findings with those of magnetic resonance (MR) imaging and muscle biopsy. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Perfusion in skeletal muscles was quantified with contrast-enhanced intermittent power Doppler US by applying a modified model that analyzed the replenishment kinetics of microbubbles. In 22 patients (16 women, six men; mean age, 52 years +/- 17) who were suspected of having myositis and in 10 healthy volunteers (two women, eight men; mean age, 28 years +/- 4), contrast-enhanced US of the clinically affected right biceps muscle was performed to measure blood flow, blood volume, and blood flow velocity. Additionally, the right upper arm was examined with a 1.5-T unit by using three different MR imaging techniques. Findings were compared with the results of clinical examinations and muscle biopsy. Data for perfusion-related parameters obtained at contrast-enhanced US were analyzed by using a nonparametric Mann-Whitney U test. RESULTS: Eight patients had histologically confirmed myositis and showed significantly higher blood flow velocity (P = .01), blood flow (P = .001), and blood volume (P = .002) at contrast-enhanced US than did patients who did not have myositis. Blood flow velocity (P = .001) and blood flow (P = .002) were significantly higher in patients with myositis than in volunteers. An increase in signal intensity on T2-weighted MR images was found in all patients with myositis, while contrast material enhancement on fat-suppressed T1-weighted MR images was found in only four of seven patients with myositis. CONCLUSION: Initial results show that contrast-enhanced US is a feasible method for noninvasively demonstrating increased perfusion in the involved muscle groups in patients with myositis.

Biopsy↗

Dynamic contrast-enhanced MRI for assessing the disease activity of multiple myeloma: a comparative study with histology and clinical markers.

PURPOSE: To examine whether parameters of dynamic, contrast-enhanced MRI (DCE MRI) reflect the degree of infiltration and vessel density in corresponding bone marrow biopsy specimens. MATERIALS AND METHODS: The pelvis of 24 patients with multiple myeloma (MM) was examined using contrast-enhanced DCE MRI. Biopsy was obtained from the spina iliaca posterior superior. Using a two-compartment model (assuming one intravascular and one interstitial compartment), the parameters amplitude (A, the maximum, relative signal increase over baseline) and the exchange rate constant (k(ep), describing the redistribution of contrast agent from the interstitial into the intravascular compartment) in the biopsied region were calculated and compared with the histological and clinical data. RESULTS: DCE MRI parameters were significantly higher in lesions with marked infiltration than with mild or no infiltration (P < 0.05). The amplitude normalized to that in the iliac artery (A(n)), but not k(ep), was higher in lesions with high vessel-density at histology (P = 0.01). Higher k(ep) levels were found in presence of increased serum immunoglobulins. CONCLUSION: Increased contrast uptake in the bone marrow of MM patients indicates at least moderate tumor involvement. Furthermore, the contrast enhancement correlates with vessel-density and serum markers of disease activity.

Biomarkers↗

Computed tomography in various fields outside medicine.

CT has been widely used for non-medical purposes, for which, as in medicine, it has the advantage of being non-destructive and having a high spatial and density resolution. CT may help to generate 3-D views which could otherwise be obtained only by dissecting the object. There is almost no limitation with regard to X-ray exposure and scanning time. Dedicated techniques, e.g., rotating the specimen between stationary tube and detector, have been developed. Micro-CT may provide a spatial resolution up to 1 microm. Fields where CT has been successfully applied are archaeology, soil science, the timber industry, biology, industrial X-ray inspection and aviation security.

Archaeology↗

Improved vascular opacification in cerebral computed tomography angiography with 80 kVp.

PURPOSE: We sought to intraindividually compare computed tomography angiographies (CTAs) acquired at 80 kVp and 120 kVp with respect to vessel contrast, noise level, and radiation dose. MATERIAL AND METHODS: CTA was performed on a single-slice CT scanner using tube voltages of 80 kVp and 120 kVp in 29 patients with arteriovenous malformations. Mean Hounsfield Units (HU) were evaluated for different vessels and brain parenchyma. To determine contrast-to-noise ratios (CNRs), noise levels were estimated from phantom measurements. RESULTS: The calculated effective dose to male/female patients was 0.4/0.5 mSv for 80 kVp and 0.7/0.8 mSv for 120 kVp. CT density in blood vessels was between 297 and 458 HU for 80 kVp and 152 and 229 HU for 120 kVp (P<0.0001). Despite an increased noise level in the low-voltage images, the CNR was 26-59% higher at 80 kVp than at 120 kVp (P<0.05). CONCLUSION: The use of a reduced tube potential leads to improved CNR in CTA of the cerebral vasculature and a markedly reduced radiation exposure to patients.

Adult↗

Classification of signal-time curves obtained by dynamic magnetic resonance mammography: statistical comparison of quantitative methods.

OBJECTIVE: This study compares the performance of quantitative methods for the characterization of signal-time curves acquired by dynamic contrast-enhanced magnetic resonance mammography from 253 females. MATERIALS AND METHODS: Signal-time curves obtained from 105 parenchyma, 162 malignant, and 91 benign tissue regions were examined (243 lesions were histopathologically validated). A neural network, a nearest-neighbor, and a threshold classifier were applied to either the entire signal-time curve or pharmacokinetic and descriptive parameters calculated from the curves to differentiate between 2 (malignant or benign) or 3 tissue classes (malignant, benign, or parenchyma). The classifiers were tuned and evaluated according to their performance on 2 distinct subsets of the curves. RESULTS: The accuracy determined for the neural network and the nearest-neighbor classifiers was nearly identical (approximately 80% in case of 3 tissue classes, and approximately 76% in case of the 2 classes). In contrast, the accuracy of the threshold classifier applied to the discrimination of 3 classes was low (65%). CONCLUSION: Quantitative classifiers can support the radiologist in the diagnosis of breast lesions.

Breast↗

Assessment of skeletal muscle perfusion using contrast-enhanced ultrasonography.

OBJECTIVE: The purpose of this study was to develop a clinically applicable examination method to assess perfusion of the skeletal muscle using contrast-enhanced ultrasonography (CEUS) analyzing replenishment kinetics of microbubbles. METHODS: Power Doppler sonography (7 MHz) after intravenous bolus injection of 10 mL of a microbubble contrast agent was used to repeatedly examine the perfusion of the right biceps muscle at rest and after defined exercise in 10 healthy volunteers. Parameters of perfusion, such as local blood volume, blood flow velocity, and perfusion, were calculated by a modified analysis of replenishment kinetics. For validation, CEUS was correlated with venous occlusion plethysmography (VOP) examining the right forearm flexor muscles at rest and after defined exercise. RESULTS: The CEUS examination was easily feasible and was able to depict the physiologic large variability of the right biceps muscle perfusion at rest (mean +/- SD, 3.0 +/- 2.3 [approximately mL/s x 100 mg]) compared with the results after exercise (22.9 +/- 11.0 [approximately mL/s x 100 mg]). The perfusion calculated with VOP significantly correlated with the CEUS parameters perfusion (r = 0.81; P < .001) and blood volume (r = 0.82; P < .001). The calculated mean blood flow velocity in the right forearm flexor muscles raised from 0.41 +/- 0.24 mm/s at rest to 0.64 +/- 0.39 mm/s after exercise, showing a significant correlation with the CEUS perfusion (r = 0.72; P < .001). CONCLUSIONS: Muscle perfusion can be easily and quantitatively assessed with CEUS. Compared with VOP, CEUS allows for a separate analysis of different muscle groups, unaffected by skin perfusion. Its application may be of particular interest in the diagnosis and monitoring of pathologic microvascularization in myositis or diabetic obstructive disease.

Arm↗

Simple models improve the discrimination of prostate cancers from the peripheral gland by T1-weighted dynamic MRI.

Evaluation of the accuracy of descriptive and physiological parameters calculated from signal intensity-time curves using T1-weighted dynamic contrast enhanced MRI (DCE MRI) to differentiate prostate cancers from the peripheral gland. Twenty-seven patients with prostate cancers were examined with DCE MRI prior radical prostatectomy. Regions of interest were defined in tumors and non-affected areas in the peripheral zone. Dynamic data were parameterized in amplitude and exchange rate constant (kep) using a two-compartment model. Additionally, relative slope during 26, 39, 52 and 65 s, areas under the curve (AUC) and time to start of signal intensity increase (tlag) were determined. Vessel density (VD) of excised prostates was quantified in tumor areas using a CD34 stain. The parameter slope52 showed 20% higher values (P<0.001) in tumors than in the peripheral gland and compared with the other parameters the largest area under the ROC curve (0.81). The minimum total error rate was attained at a cut-point of 0.021, yielding a sample value of sensitivity and specificity of 70% and 88%, respectively, and a bias-corrected sum of sensitivity and specificity of 1.54. In addition, amplitude (P<0.001), kep (P=0.03) and AUC (P<0.001) were significantly higher in tumors. tlag did not discriminate carcinomas from glandular tissue. VD was higher in tumors than in the non-affected peripheral prostate (P=0.05). However, none of the dynamic parameters in carcinomas showed a significant correlation with VD or Gleason score. Although pharmacokinetic modeling in DCE MRI showed potential to discriminate prostate cancers from peripheral prostate tissue, descriptive parameters of the early signal enhancement after contrast media injection reached higher sensitivity and specificity.

Aged↗

Time-resolved contrast-enhanced three-dimensional pulmonary MR-angiography: 1.0 M gadobutrol vs. 0.5 M gadopentetate dimeglumine.

PURPOSE: To compare contrast characteristics and image quality of 1.0 M gadobutrol with 0.5 M Gd-DTPA for time-resolved three-dimensional pulmonary magnetic resonance angiography (MRA). MATERIALS AND METHODS: Thirty-one patients and five healthy volunteers were examined with a contrast-enhanced time-resolved pulmonary MRA protocol (fast low-angle shot [FLASH] three-dimensional, TR/TE = 2.2/1.0 msec, flip angle: 25 degrees, scan time per three-dimensional data set = 5.6 seconds). Patients were randomized to receive either 0.1 mmol/kg body weight (bw) or 0.2 mmol/kg bw gadobutrol, or 0.2 mmol/kg bw Gd-DTPA. Volunteers were examined three times, twice with 0.2 mmol/kg bw gadobutrol using two different flip angles and once with 0.2 mmol/kg bw Gd-DTPA. All contrast injections were performed at a rate of 5 mL/second. Image analysis included signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements in lung arteries and veins, as well as a subjective analysis of image quality. RESULTS: In patients, significantly higher SNR and CNR were observed with Gd-DTPA compared to both doses of gadobutrol (SNR: 35-42 vs.17-25; CNR 33-39 vs. 16-23; P < or = 0.05). No relevant differences were observed between 0.1 mmol/kg bw and 0.2 mmol/kg bw gadobutrol. In volunteers, gadobutrol and Gd-DTPA achieved similar SNR and CNR. A significantly higher SNR and CNR was observed for gadobutrol-enhanced MRA with an increased flip angle of 40 degrees. Image quality was rated equal for both contrast agents. CONCLUSION: No relevant advantages of 1.0 M gadobutrol over 0.5 M Gd-DTPA were observed for time-resolved pulmonary MRA in this study. Potential explanations are T2/T2*-effects caused by the high intravascular concentration when using high injection rates.

Adult↗

Microcirculation and microvasculature in breast tumors: pharmacokinetic analysis of dynamic MR image series.

The purpose of this study was to quantify microcirculation and microvasculature in breast lesions by pharmacokinetic analysis of Gd-DTPA-enhanced MRI series. Strongly T1-weighted MR images were acquired in 18 patients with breast lesions using a saturation-recovery-TurboFLASH sequence. Concentration-time courses were determined for blood, pectoral muscle, and breast masses and subsequently analyzed by a two-compartment model to estimate plasma flow and the capillary transfer coefficient per unit of plasma volume (F/VP, KPS/VP) as well as fractional volumes of the plasma and interstitial space (fP, fI). Tissue parameters determined for pectoral muscle (fP = 0.04 +/- 0.01, fI = 0.09 +/- 0.01, F/VP = 2.4 +/- 1.3 min(-1), and KPS/VP = 1.2 +/- 0.5 min(-1)) and 10 histologically proven carcinomas (fP = 0.20 +/- 0.07, fI = 0.34 +/- 0.16, F/VP = 2.4 +/- 0.7 min(-1), and KPS/VP = 0.86 +/- 0.62 min(-1)) agreed reasonable well with literature data. Best separation between malignant and benign lesions was obtained by the ratio KPS/F (0.35 +/- 0.17 vs. 1.23 +/- 0.65). The functional imaging technique presented appears promising to quantitatively characterize tumor pathophysiology. Its impact on diagnosis and therapy management of breast tumors, however, has to be evaluated in larger patient studies.

Breast Neoplasms↗

Quantification of perfusion of liver tissue and metastases using a multivessel model for replenishment kinetics of ultrasound contrast agents.

Low-MI (mechanical index) ultrasound allows real-time observation of replenishment kinetics after destruction ("flash") of ultrasound contrast agents (USCA). We developed an examination protocol and a mathematical model to quantify perfusion of liver tissue and hepatic metastases. Using a modified multivessel model, we attempted a consistent, physiological description of microbubble replenishment in liver tissue. Perfusion parameters were calculated, separately for the arterial and portal venous phase of liver perfusion, using an i.v. bolus injection of 2 x 2.4 mL SonoVue. The model was evaluated for 10 examinations of liver metastases using flash/low-MI imaging. In contrast to the established, exponential model, the new model consistently describes the sigmoid replenishment of USCA measured in vivo, using flash/low-MI imaging. Parameters for blood volume, blood velocity and blood flow in liver tissue and metastases can be calculated during the arterial and the portal venous phase after a CA bolus injection. The median arterial perfusion in the examined liver metastases was more than 2.5 times higher than in normal liver tissue, whereas the median perfusion during the portal venous phase was more than five times higher in the liver tissue than that in metastases. Microbubble replenishment measured with flash/low-MI US techniques can be consistently analyzed using the multivessel model, even after a bolus injection of USCA. This allows for the quantification of perfusion of liver tissue and hepatic metastases and provides promising parameters of tissue viability and tumor characterization.

Arteries↗

Low mechanical index contrast-enhanced ultrasound better reflects high arterial perfusion of liver metastases than arterial phase computed tomography.

RATIONALE AND OBJECTIVES: We investigated whether observing the arterial vascularization of liver metastases by contrast-enhanced ultrasound with low mechanical index (low-MI) imaging offers additional diagnostic information for the characterization of the liver lesions. METHODS: Twenty nine patients with untreated liver metastases of different primaries were examined. Measurements were performed using a low frame rate, low-MI pulse inversion technique after injection of 2.4 mL SonoVue. The relative maximum signal intensity of the liver lesions related to the normal liver tissue was quantified. Ultrasound findings were compared with contrast-enhanced, dual-phase computed tomography (CT) using a pattern-based classification scheme. RESULTS: Compared with contrast-enhanced CT, this modality better detects arterial perfusion. Metastases, even those usually considered hypovascularized, often showed homogeneous enhancement (66%) and higher arterial vascularization than normal liver tissue. CT did not show a comparable vascularization pattern (P < 0.001) or any similarly early signal intensity (P < 0.001). CONCLUSIONS: Contrast-enhanced CT may not be able to visualize short-lasting but large differences of the arterial perfusion of liver metastases, as does contrast-enhanced low-MI ultrasound. This offers new methods for their characterization and for monitoring of therapeutic effects.

Contrast Media↗