Corrosion of tungsten coils after peripheral vascular embolization therapy: influence on outcome and tungsten load.

The purpose of this study was to evaluate coil corrosion and the long-term outcome after peripheral vascular embolization therapy performed with tungsten coils. We studied 14 patients who received tungsten coils on an average of 26 months prior to follow-up. The protocol included plain radiography and contrast-enhanced magnetic resonance angiography to investigate corrosion of tungsten coils and recanalization of the embolized vessels. Whole blood, hair, and urine tungsten levels were assayed when available. Corrosion of tungsten coils was detected in 9 of 14 patients by plain radiography. No evidence of recanalization of the embolized vessel and no adverse clinical effects of tungsten resorption were detected. Blood levels of tungsten were elevated in 6 of 14 patients and urine levels of tungsten were elevated in all 12 patients tested. Tungsten coil corrosion and elevated tungsten levels in blood, hair, and urine were found in most patients, although no adverse clinical effects of tungsten resorption were detected. Since the overall effect of high tungsten blood levels remains unclear, its use as an implant should be avoided.

Adult↗

Abdominal MRI after enteroclysis or with oral contrast in patients with suspected or proven Crohn's disease.

BACKGROUND & AIMS: Diagnostic results of magnetic resonance (MR) enteroclysis correlate highly with those from conventional enteroclysis; nevertheless, intubation of the patient and positioning of an intestinal tube is still necessary for the examination, which is often remembered as the most embarrassing part of the examination by the patient. A more comfortable and highly sensitive examination of the small bowel therefore would increase patient acceptance for recurring examinations, which are often necessary, for example, in patients with Crohn's disease. This study evaluates the diagnostic efficacy of abdominal MR imaging (MRI) of the small bowel after drinking contrast agent only compared with conventional enteroclysis and abdominal MRI performed after enteroclysis in patients with suspected or proven Crohn's disease. METHODS: Twenty-one patients with Crohn's disease referred for conventional enteroclysis underwent abdominal MRI after enteroclysis. Additionally, 1 to 3 days before or after these examinations, abdominal MRI was performed using only orally administered contrast. All MRI examinations were performed using a 1.5T scanner. RESULTS: All pathological findings on conventional enteroclysis were shown correctly with MRI after enteroclysis and MRI after oral contrast only. Additional information by MRI was obtained in 6 of 21 patients. No statistically significant differences were found in assessing the diagnostic efficacy of the 3 examinations. CONCLUSIONS: Abdominal MRI with oral contrast only can be used as a diagnostic tool for evaluation of the small bowel in patients with Crohn's disease and has the potential to replace conventional enteroclysis as follow-up.

Administration, Oral↗

Early regression of left ventricular hypertrophy after aortic valve replacement by the Ross procedure detected by cine MRI.

AIM: The primary objective of our study was to assess the time course of left ventricular remodeling after the Ross procedure with the use of cine magnetic resonance imaging (MRI). METHODS: In a prospective study, 10 patients with isolated aortic valve disease were examined prior to aortic valve surgery, as well as at early follow-up (mean 4 weeks) and at late follow-up (mean 8 months) after pulmonary autograft aortic valve replacement (Ross procedure). The heart was imaged with a 1.5 T MR scanner along the short and long axes using a breath-hold, electrocardiogram (ECG)-triggered, cine gradient-echo sequence (FLASH). Myocardial mass and ventricular function were assessed. RESULTS: After aortic valve replacement, left ventricular myocardial mass (LVM) decreased by 13% (261 +/- 74 g to 230 +/- 65 g, p < 0.05) in the early postoperative period and by a further 16% in the late postoperative period to 192 +/- 31 g (p < 0.05). In addition, left ventricular end-diastolic and end-systolic volumes decreased from preoperative 187 +/- 89 mL (LV EDV) and 73 +/- 59 mL (LV ESV) to 119 +/- 55 mL and 56 +/- 42 mL, respectively, in the early postoperative period. In the late postoperative period, there was a further decrease to 98 +/- 30 (p < 0.05) and 33 +/- 19 mL, respectively. Ejection fraction did not change markedly after surgery (preoperatively 61 +/- 13% vs. 56 +/- 14% postoperatively). Patients with leading aortic stenosis were characterized by predominant regression of LVM and patients with leading aortic regurgitation by predominant regression of LV EDV (each p < 0.05). CONCLUSION: Cine MRI allows accurate assessment of left ventricular structure and geometry before and after aortic valve replacement with pulmonary autograft and is very sensitive in detecting relatively small changes of left ventricular myocardial mass and volumes early after hemodynamic relief as well as during serial assessment.

Adult↗

Modern imaging using computer tomography and magnetic resonance imaging for inflammatory bowel disease (IBD) AU1.

Radiologic imaging--especially of the small bowel--plays an important role in the diagnosis and management of patients with inflammatory bowel disease. The radiographic examination of the small intestine with barium either as enteroclysis or as small bowel follow through are still the mainstays in small bowel imaging. However, abdominal CT or MRI, which has the advantage of not utilizing ionizing radiation, or the techniques of CT- or MR-enteroclysis, are overall comparable with regard to the sensitivity and specificity in detecting intestinal pathologies and have already replaced the conventional techniques in centers dedicated to the management of inflammatory bowel disease. Additionally, these cross-sectional imaging techniques provide, in a sense, a "one stop abdominal imaging workup," the diagnosis of extraluminal disease manifestations or complications. Future developments of CT- or MR-based virtual colonography and endoscopy in patients with inflammatory bowel disease are currently being investigated, but should momentarily be considered as purely experimental approaches.

Colonoscopy↗

Contrast-enhanced magnetic resonance angiography of the carotid arteries: influence of injection rates and volumes on arterial-venous transit time.

RATIONALE AND OBJECTIVES: To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evaluated. MATERIALS AND METHODS: In 60 patients a CM injection was necessary to investigate suspected cranial disease. All patients were prospectively assigned to 6 protocol groups with varying volumes of gadolinium dimeglumine (2, 10, 20 mL) and injection rates (0.5, 1, 2, 4 mL/s). Simultaneously to the CM injection, 50 repetitive transverse measurements (1/s) were acquired at the level of the common carotid artery. Based on the resulting signal-time curves, the arrival time of the contrast material in the common carotid artery and the jugular vein, the resulting arterial-venous transit time, the peak enhancement and the extent of a CM-plateau were calculated as a function of the injection parameters. RESULTS: Smaller flow rates (0.5 mL/s) resulted in a longer arrival time in the common carotid artery (mean value 22,6 seconds +/- 2.3) and the jugular vein (mean value 32.6 seconds +/- 2.6) and resulted in longer arterial-venous transit time (mean value 10.1 second +/- 1.9). The volume showed no effect on these parameters. The peak arterial and venous signal intensity and a consistent CM-plateau after 50 seconds were dependent on the volume, but not on the injection rate. CONCLUSION: The injection rate showed an influence to the arrival time in the common carotid artery and the jugular vein and also to the arterial-venous transit time. The injected volume only affected the extent of the contrast plateau. A flow rate of 1 to 2 mL/s and a minimum of 20 mL gadolinium dimeglumine are recommended to achieve optimal image quality without venous overlay.

Adolescent↗

Amorphous silicon, flat-panel, x-ray detector: reliability of digital image fusion regarding angle and distance measurements in long-leg radiography.

RATIONALE AND OBJECTIVES: To evaluate composed long-leg images acquired with a large-area, flat-panel x-ray detector with regard to angle and distance measurements. METHODS: Radiographs of a long-leg phantom were acquired at 13 different angle settings with a 43-cm x 43-cm digital x-ray detector based on cesium iodide (CsI) and amorphous silicon (a-Si) technology. Three overlapping single images of the phantom were reconstructed at a workstation using a generalized correlation method. Four blinded observers were instructed to determine the angle of the axis of the long-legs as well as the length of "femur" and "tibia" on soft-copy displays. For that, the angle and distance measurement software integrated in the workstation was used. The images were analyzed with and without prior manual fine tuning of the primary composition result according to a mapped scale. Standard of reference was angle and distance determination at the phantom. RESULTS: On average, the difference between the observers' angle measurements and the standard of reference was 0.4 degrees for both images with and without prior manual correction. Regarding distance measurements, the average discrepancies to the standard were 0.2 cm (femur) and 0.1 cm (tibia) when analyzing images that had undergone manual fine tuning and 0.5 cm and 0.7 cm, respectively, for images without manual correction. CONCLUSIONS: The evaluated image fusion algorithm in conjunction with a 43-cm x 43-cm flat-panel detector is feasible regarding angle and distance measurements on long-leg images. In the case of inaccurate primary composition, results can be corrected easily by manual fine tuning.

Algorithms↗

Contrast-detail phantom study for x-ray spectrum optimization regarding chest radiography using a cesium iodide-amorphous silicon flat-panel detector.

RATIONALE AND OBJECTIVES: The purpose of this study evaluating a cesium iodide-amorphous silicon-based flat-panel detector was to optimize the x-ray spectrum for chest radiography combining excellent contrast-detail visibility with reduced patient exposure. MATERIALS AND METHODS: A Lucite plate with 36 drilled holes of varying diameter and depth was used as contrast-detail phantom. For 3 scatter body thicknesses (7.5 cm, 12.5 cm, 21.5 cm Lucite) images were obtained at 113 kVp, 117 kVp, and 125 kVp with additional copper filter of 0.2 and 0.3 mm, respectively. For each setting, radiographs acquired with 125 kVp and no copper filter were taken as standard of reference. On soft-copy displays, 3 observers blinded to the exposure technique evaluated the detectability of each aperture in each image according to a 5-point scale. The number of points given to all 36 holes per image was added. The scores of images acquired with filtration were compared with the standard images by means of a multivariate analysis of variance. Radiation burden was approximated by referring to the entrance dose and calculated using Monte Carlo method. RESULTS: All 6 evaluated x-ray spectra resulted in a statistically equivalent contrast-detail performance when compared with the standard of reference. The combination 125 kVp with 0.3 mm copper was most favorable in terms of dose reduction (approximately 33%). CONCLUSION: Within the constraints of the presented contrast-detail phantom study simulating chest radiography, the CsI/a-Si system enables an addition of up to 0.3 mm copper filtration without the need for compensatory reduction of the tube voltage for providing constant image quality. Beam filtration reduces radiation burden by about 33%.

Cesium↗

Intraarterial contrast material-enhanced magnetic resonance angiography of the aortoiliac system.

In a period of 4 months, 10 patients were examined prospectively with intraarterial magnetic resonance (MR) angiography after digital subtraction angiography. Intraarterial MR angiography was performed with use of a 1.5-T MR imaging system. Contrast agent (gadodiamide) was injected with a conventional angiography catheter placed in the proximal abdominal aorta. The increase in vascular signal intensity was determined and the diagnostic value of the MR angiograms was scored according to a five-point scale by four investigators. The MR angiograms were judged good to excellent, and all were scored as diagnostic. In conclusion, this study shows that intraarterial MR angiography is feasible. Intraarterial MR angiography is appropriate to support MR-guided vascular intervention.

Adult↗

Iliac artery stent placement: clinical experience and short-term follow-up regarding a self-expanding nitinol stent.

PURPOSE: To evaluate the effectiveness, safety, and short-term patency rates of a self-expandable nitinol stent (JostentSelfX; Abbott Laboratories, Chicago, IL) for treatment of iliac artery stenoses. MATERIALS AND METHODS: In a prospective study, 34 chronic iliac artery stenoses were primarily treated in 27 patients (mean age, 61.7 years +/- 9.4) by placement of a JostentSelfX. Handling and visibility of the stent was scored on a 4-point scale. Before stent placement, within 3 days after stent placement and at 6 months follow-up, the clinical history, clinical stage according to the Rutherford classification, and the ankle-brachial index (ABI) were assessed. Intra-arterial digital subtraction angiography including measurement of the mean pressure gradient was performed at the time of stent placement and at 6 months follow-up or in case of recurrence of symptoms. The Wilcoxon signed rank test and Kaplan-Meier method were applied for statistical analysis. RESULTS: The immediate technical success rate was 94%. The clinical success rate immediately after the procedure was 96% and 85% at 6 months follow-up. Stent placement significantly decreased the severity of stenoses as well as the mean pressure gradients and significantly increased the ABI. Handling of the stent was judged good. No misplacement occurred. Foreshortening during deployment was negligible and no stent migration was seen. However, visibility of the stent during fluoroscopy was ranked as moderate to bad. Follow-up at 6 months revealed the cumulative angiographic primary patency rate (<50% restenosis and <10 mm Hg mean pressure gradient) to be 0.96. CONCLUSION: The evaluated self-expandable nitinol stent is an effective tool in treating iliac artery stenoses. Apart from poor visibility, handling was good. The angiographic patency rate is comparable with data reported in other stent trials.

Alloys↗

Safety and efficacy of the Perclose suture-mediated closure device following carotid artery stenting under clopidogrel platelet blockade.

The aim of this study was evaluation of a closure device (Perclose, Menlo Park, Calif.) for closure of the femoral artery access site in patients undergoing aggressive anticoagulation and platelet blockade after carotid stenting. Fifty-five patients who received clopidogrel in addition to aspirin and heparin as medication for carotid stenting were included for suture of the femoral access site after using 7- or 8-F guide catheters. The technical success, the time for suture, the clotting parameters, and complications were examined. Follow-up investigations, including ultrasound and clinical examinations, were performed. The groin was checked for possible hematoma, pseudoaneurysm, arteriovenous fistula, and local infection. Technical success was obtained in 51 of 54 patients (94%) after a mean procedure time of 6 min (range 5-10 min). The suture device was not used in one patient (2%) for anatomical reasons and failed to obtain hemostasis in 3 of 54 (6%) patients. In 4 of 54 patients (7%) bleeding was observed at the punctured site 4-6 h after intervention which was treated by a compression bandage. The mean dedicated activated clotting time was 137 s (range 29-287 s) before intervention and 349 s (150-958 s) just before deploying the Perclose device. During follow-up after 2 days (range 2-6 days) and 6 months no further complications of the puncture site were observed except for two large groin hematomas. No major complications occurred. Closure of the femoral access site after carotid stenting using a Perclose closure device is safe and effective even in patients receiving an aggressive anticoagulation and antiplatelet therapy.

Aged↗

Digital image composition in long-leg radiography with a flat-panel detector: first clinical experiences.

RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate the image quality of composed long-leg examinations with a large-area, flat-panel x-ray detector. METHODS: Thirty-five consecutive patients were included in this study. All images were obtained with a kilovoltage setting identical with conventional radiographies of speed class 400; amperage values were reduced by 50% compared with standard dose. After acquisition, the images were transferred to a workstation where the whole image was reconstructed using a generalized correlation method. Images were presented to 3 observers. Examination quality was ranked on a 3-point scale: 1 = no manual adjustment necessary; 2 = composition required manual correction; 3 = no composition possible. RESULTS: Patient rankings were 31/35 (88.6%) in category 1, 3/35 (8.6%) in category 2, and 1/35 (2.8%) in category 3 (primarily due to an application error). CONCLUSIONS: The analysis of the first clinical examinations of long-leg radiographies with a 43 cm x 43 cm flat-panel detector demonstrates very good reliability of the digital image composition.

Cesium↗

Amorphous silicon, flat-panel, x-ray detector versus storage phosphor-based computed radiography: contrast-detail phantom study at different tube voltages and detector entrance doses.

RATIONALE AND OBJECTIVES: Evaluation of the contrast-detail performance of an active-matrix flat-panel x-ray detector in comparison with a storage phosphor system with special regard to the potential of dose reduction. METHODS: A digital x-ray detector based on cesium iodide (CsI) and amorphous silicon (a-Si) technology was compared with a fifth-generation storage phosphor system. A lucite plate with 36 drilled holes of varying diameters and depths was used as contrast-detail phantom. At 45 kVp, 70 kVp, and 113 kVp, images at 8 different detector entrance doses ranging between 0.3 microGy and 40 microGy were obtained. On soft-copy displays, 3 masked observers evaluated the detectability of each aperture in each image according to a 5-point scale. The mean sum scores of corresponding images were compared. RESULTS: For all tube voltages and detector entrance doses, the images obtained with the CsI/a-Si detector resulted in better observer contrast-detail performance as compared with the images of the storage phosphor system. The CsI/a-Si system allowed a calculated dose reduction of 39% at 45 kVp, 68% at 70 kVp, and 81% at 113 kVp as compared with the storage phosphor system, without loss of contrast-detail detectability. CONCLUSIONS: Under the conditions of the chosen experimental design, the CsI/a-Si system provided a superior contrast-detail performance as compared with the storage phosphor system. The potential of dose reduction increased with rising tube voltage.

Cesium↗

Routine skeleton radiography using a flat-panel detector: image quality and clinical acceptance at 50% dose reduction.

RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate image quality and clinical acceptance of a large-area, flat-panel X-ray detector for routine skeleton examinations at 50% dose reduction. METHODS: A total of 153 examinations (307 images) of 100 consecutive patients were evaluated. The cesium iodide-amorphous silicon active-matrix imager had a panel size of 43 x 43 cm, a matrix of 3000 x 3000, and a pixel pitch of 143 microm. All images were obtained with a kilovoltage setting identical to conventional radiographies of speed class 400. The amperage values were reduced by 50% compared with standard dose. Images were presented to 3 radiologists, who subjectively rated image quality on a 4-point scale according to 5 criteria (bone cortex, bone trabecula, soft tissue, overall contrast, and overall impression). Three trauma surgeons rated the clinical acceptance on a 4-point scale. Clinical acceptance was defined as directly derived consequences or therapy based on the presented image quality. For both evaluations, 1 represented excellent, 2 represented good, 3 represented moderate, and 4 represented nondiagnostic image quality/clinical acceptance. Intermediate scores at 0.5 intervals were allowed. RESULTS: The mean values for all 5 image quality criteria were rated good or excellent (< or = 2). A total of 4.2% (13 of 307) of the images were rated 2.5 to 3.5 concerning the overall impression. None of the imaging features was ranked more than 3.5 by any radiologist. The mean value of the clinical acceptance was between good and excellent (1.47). A total of 98.7% (151 of 153) of the examinations were rated < or = 2.5; 1.3% (2 of 153) of examinations were of moderate clinical acceptance (< or = 3.5). None of the examinations was of nondiagnostic image quality or clinical acceptance (>3.5); therefore, no study had to be repeated. CONCLUSION: Routine skeleton images with 50% dose reduction yield good image quality and good clinical acceptance. In cases with abundant soft tissue, less dose reduction or standard dose is required.

Adult↗

Peripheral arterial balloon angioplasty: effect of short versus long balloon inflation times on the morphologic results.

PURPOSE: To evaluate the effect of different balloon inflation times on angiographic results in peripheral angioplasty. MATERIALS AND METHODS: Seventy-four infrainguinal arteriosclerotic lesions were randomized prospectively to undergo balloon dilation for 30 seconds (group I) or 180 seconds (group II). Each group consisted of 37 patients. Postinterventional angiograms were evaluated by two blinded readers. Dissections were graded as follows: 1 = no dissection; 2 = minor flap; 3 = extensive dissection membrane, not flow limiting; or 4 = flow-limiting flap. The rate of major-grade dissections (grades 3 and 4), residual stenosis (>30%), and further interventions were compared with the two-tailed chi(2) test. RESULTS: In group I, major dissections were noted in 16 patients (43%) compared with five patients (14%) in group II (P =.009). Residual stenoses were found in 12 patients (32%) in group I compared with five patients (14%) in group II (P =.096). The rate of additional interventions was significantly higher in group I than in group II (20 of 37 vs nine of 37; P =.017). CONCLUSION: A prolonged inflation time of 180 seconds improves the immediate angioplasty result of infrainguinal lesions compared to a short dilation strategy. Significantly fewer major dissections and a modest reduction of residual stenoses are observed. The requirement of costly and time-consuming further interventions is significantly reduced.

Aged↗

3D modeling and virtual endoscopy of the small bowel based on magnetic resonance imaging in patients with inflammatory bowel disease.

RATIONALE AND OBJECTIVES: Small bowel MRI (MR imaging) is a new imaging modality that excellently depicts small intestine pathology in patients with inflammatory bowel disease. Virtual endoscopy based on sectional imaging is a recently introduced technique to create endoscopy like views. The aim of this study was to evaluate the feasibility of virtual small bowel endoscopy based on MR imaging in patients with Crohn disease. MATERIALS AND METHODS: Thirty consecutive patients with Crohn disease were scanned after oral application of pineapple juice for contrasting the small bowel. Dedicated high resolution T1 weighted 3D-FLASH sequences with fat suppression were used for volume scanning. Volume-rendered 3D models of the small bowel were created and virtual endoscopy was performed. The feasibility and quality of this new visualization method was assessed. RESULTS: In nine of 30 patients virtual endoscopy was considered as good quality (flight through the entire small bowel was possible, typical folds were revealed). In 18 patients fair quality (at least 4/5 of the small bowel were depicted adequately) was assessed. In three of 30 patients virtual endoscopy was not sufficiently possible because of inadequate bowel filling or breathing artifacts. Three fistulae diagnosed on 2D MRI were visualized on the virtual endoscopic view. CONCLUSION: Virtual endoscopy of the small bowel is feasible based on high resolution MR imaging. Vivid insight views and 3D models provide an interesting addition to sectional MR findings.

Adolescent↗

Time-resolved contrast-enhanced magnetic resonance angiography of the carotid arteries: diagnostic accuracy and inter-observer variability compared with selective catheter angiography.

RATIONALE AND OBJECTIVES: To assess the diagnostic accuracy and interobserver variability of contrast-enhanced magnetic resonance angiography (CE-MRA) in a time-resolved technique compared with digital subtraction angiography (x-ray DSA) in patients with suspected stenoses of the internal carotid artery. MATERIALS AND METHODS: A total of 43 patients were enrolled in this prospective study. All patients underwent selective x-ray DSA involving a total of 84 carotid arteries. CE-MRA was performed in a time-resolved technique with a fast gradient-echo sequence on a 1.5 T MR scanner: TR 3.8 milliseconds, TE 1.49 milliseconds. Four consecutive measurements, each a duration of 10 seconds, were performed with omission of measuring bolus transit time. Four independent radiologists scored the degree of stenosis. The interobserver variability was calculated for CE-MRA and x-ray DSA. RESULTS: In the 43 cases, at least one MRA measurement showed arterial contrast without venous degradation. Compared with x-ray DSA the mean sensitivity and specificity for grading stenosis > or = 70% were 98% and 86%, respectively. The interobserver agreement was substantial with no significant difference between CE-MRA (kappa value 0.794) and x-ray DSA (kappa value 0.786). CONCLUSIONS: The short acquisition time of a fast CE-MRA sequence allows a selective visualization of the internal carotid arteries without degradation from venous enhancement. It is a reliable method with a good interobserver agreement.

Adult↗