A multicenter, site-independent, blinded study to compare the diagnostic accuracy of contrast-enhanced magnetic resonance angiography using 1.0M gadobutrol (Gadovist) to intraarterial digital subtraction angiography in body arteries.

PURPOSE: Prospective evaluation of diagnostic accuracy of single field-of-view contrast-enhanced MR Angiography (ceMRA) with 1.0M gadobutrol compared to intraarterial DSA in body arteries. MATERIALS AND METHODS: In an European multicenter study 179 patients underwent ceMRA and DSA. For each indication five prospectively defined vessel segments were evaluated by local investigators onsite and by three site-independent blinded readers (BR) independently. RESULTS: The agreement between ceMRA and DSA diagnosis was statistically significant in the onsite (96.6%) and blinded reader (86.6-90.2%) evaluation. Sensitivity, specificity, accuracy, positive (PPV) and negative predictive values (NPV) for detection of relevant stenosis (>50%) were calculated for the right and left internal carotid arteries, and common and external iliac arteries: Sensitivity was 95-98% (onsite) and 76-96% (BR), specificity 94-96% (onsite) and 86-94% (BR), accuracy 96% (onsite) and 87-93% (BR), NPV 98-99% (onsite) and 84-98% (BR), and PPV 79-93% (onsite) and 44-91% (BR), respectively. CONCLUSION: CeMRA of body arteries using 1.0M gadobutrol provides diagnostic information comparable to intraarterial DSA.

Adult↗

Indirect MR lymphangiography of the head and neck using conventional gadolinium contrast: a pilot study in humans.

PURPOSE: To evaluate indirect magnetic resonance lymphangiography (MR-LAG) using interstitial injection of conventional gadolinium contrast (gadoteridol and gadopentetate dimeglumine) for delineating the primary lymphatic drainage of head-and-neck sites. METHODS AND MATERIALS: We performed head-and-neck MR-LAG in 5 healthy volunteers, with injection of dermal and mucosal sites. We evaluated the safety of the procedure, the patterns of enhancement categorized by injection site and nodal level, the time course of enhancement, the optimal concentration and volume of contrast, and the optimal imaging sequence. RESULTS: The worst side effects of interstitial contrast injection were brief, mild pain and swelling at the injected sites that were self-limited. MR-LAG resulted in consistent visualization of the primary lymphatic drainage pattern specific to each injected site, which was reproducible on repeated examinations. The best enhancement was obtained with injection of small volumes (0.3-0.5 mL) of either agent diluted, imaging within 5-15 min of injection, and a three-dimensional fast spoiled gradient echo sequence with magnetization transfer. CONCLUSIONS: We found head-and-neck MR-LAG to be a safe, convenient imaging method that provides functional information about the lymphatic drainage of injected sites. Applied to head-and-neck cancer, it has the potential to identify sites at highest risk of occult metastatic spread for radiotherapy or surgical planning, and possibly to visualize micrometastases.

Adult↗

MR imaging with remote control: feasibility study in cardiovascular disease.

The institutional review board approved this HIPAA-compliant study and waived informed consent. The purpose was to retrospectively evaluate remote control magnetic resonance (MR) imaging in complex cardiovascular procedures, whereby operational expertise was made available locally from a remote location. Thirty patients underwent cardiac (12 patients) and/or vascular (30 patients) 1.5-T MR imaging with a remote operator by using a personal computer. All patient studies were compared with 30 control studies obtained with conventional local imaging. Cardiac cine, myocardial delayed enhancement, and MR angiograms were assessed for overall image quality and motion artifact. MR angiograms were evaluated for vascular definition. Image quality was excellent in 90% (38 of 42) of remote images versus 60% (25 of 42) of control group images (P < .01). Scores for motion artifact were not significantly different (P = .11). Interactive MR imaging was successfully implemented with remote control in complex cardiovascular cases; diagnostic quality of images was superior to that of images obtained locally.

Adolescent↗

Magnetic resonance imaging of renal disease: recent developments and future applications.

Magnetic resonance imaging (MRI) offers the ability to non-invasively assess parenchymal and vascular renal disease. Indications for renal MRI include the evaluation of renal masses, urinary obstruction and infection, renal vasculature, and the health of transplant kidneys. The potential of MR angiography to replace invasive conventional x-ray angiography has been recognized for many years. Recent developments in MRI resulting from fast MR systems with faster gradients, new surface coil designs and the latest sequence developments coupled with innovative contrast agent administration strategies have prompted substantial progress of MRI in the diagnosis of renal disease. The goal of this article is to present the current state of MRI in diagnosing renal disease, with an emphasis on the latest developments in the evaluation of renal vascular disease.

Forecasting↗

Evaluation of living liver donors with an all-inclusive 3D multi-detector row CT protocol.

PURPOSE: To prospectively assess parenchymal, vascular, and biliary anatomy of potential living liver donors with an all-inclusive multi-detector row computed tomographic (CT) approach. MATERIALS AND METHODS: A total of 250 potential living liver donors (112 women, 138 men; mean age, 37 years) underwent three-phase, dual-enhancement multi-detector row CT to delineate biliary, vascular, and parenchymal morphology according to an institutional review board-approved protocol. Informed consent was obtained from all subjects. For display of the biliary system, the first CT image set was collected after the infusion of a biliary contrast agent. CT angiography was subsequently performed, after automated injection of a conventional iodinated contrast agent, to display the arterial and portal-hepatic venous systems. All data sets were reconstructed in 1-mm sections. Data analysis was based on source images, multiplanar reconstructions, and three-dimensional postprocessing images; was performed in consensus by two radiologists; and was focused on the detection of biliary and vascular variants, exclusion of focal liver lesions, and determination of hepatic volumes. Preoperative findings were correlated with intraoperative findings (available in 62 subjects). RESULTS: Technical failures were experienced in 10 of 250 examinations. Twenty-seven subjects had moderate adverse reactions related to the biliary contrast agent. Benign hepatic lesions were detected in 61 candidates; one candidate had a renal cell carcinoma. Underlying biliary and vascular anatomy was displayed at least to the second intrahepatic branch in all but seven patients. Detected anatomic variants involved the biliary (38.8%), arterial (40.0%), portal venous (21.4%), and hepatic venous (43.5%) systems. Correlation with intraoperative findings was excellent. Some biliary (n = 4), arterial (n = 5), portal venous (n = 1), and hepatic venous (n = 6) variants were missed or misinterpreted at initial reading of preoperative data; however, variants could be retrospectively depicted in all but one biliary case and one hepatic venous case. CONCLUSION: The outlined three-phase, dual-enhancement multi-detector row CT protocol represents an all-inclusive approach to evaluate potential living liver donors in a single diagnostic step.

Adolescent↗

MR colonography for the assessment of colonic anastomoses.

PURPOSE: To assess colonic anastomoses in patients after surgical treatment by means of MR colonography (MRC) in comparison with conventional colonoscopy (CC). MATERIALS AND METHODS: A total of 39 patients who had previously undergone colonic resection and end-to-end-anastomosis were included in the study. MRI was based on a dark-lumen approach. Contrast-enhanced T1-weighted (T1w) three-dimensional (3D) images were collected following the rectal administration of water for colonic distension. The MRC data were evaluated by two radiologists. The criteria employed to evaluate the anastomoses included bowel wall thickening and increased contrast uptake in this region. Furthermore, all other colonic segments were assessed for the presence of pathologies. RESULTS: In 23 and 20 patients the anastomosis was rated to be normal by MRC and CC, respectively. In three patients CC revealed a slight inflammation of the anastomosis that was missed by MRI. A moderate stenosis of the anastomosis without inflammation was detected by MRC in five patients, which was confirmed by CC. In the remaining 11 patients a relevant pathology of the anastomosis was diagnosed by both MRC and CC. Recurrent tumor was diagnosed in two patients with a history of colorectal carcinoma. In the other nine patients inflammation of the anastomosis was seen in seven with Crohn's disease (CD) and two with ulcerative colitis. MRC did not yield any false-positive findings, resulting in an overall sensitivity/specificity for the assessment of the anastomosis of 84%/100%. CONCLUSION: MRC represents a promising alternative to CC for the assessment of colonic anastomoses in patients with previous colonic resection.

Adult↗

Magnetic resonance imaging of experimental atherosclerotic plaque: comparison of two ultrasmall superparamagnetic particles of iron oxide.

PURPOSE: To evaluate a new ultrasmall superparamagnetic particles of iron oxide (USPIO) compound, ferumoxytol, as a marker of macrophage activity in atherosclerotic plaques and to compare it to ferumoxtran-10. MATERIALS AND METHODS: Ten mature heritable hyperlipidemic (WHHL) female Watanabe rabbits served as the animal model for atherosclerosis, four coeval female New Zealand White (NZW) rabbits were the control group. Five WHHL and two NZW received a single intravenous injection (250 micromol/kg) of either ferumoxtran-10 or ferumoxytol and were subjected to daily MR examinations on a 1.5T whole body scanner for the next five days. Development of signal intensity changes and susceptibility effects was assessed. Statistical analysis was based on a nonparametric Wilcoxon-Mann-Whitney-U test by using a P value at the 0.05 significance level. On day 5, the rabbits were sacrificed and the aorta was referred to histopathology, distribution of iron particles in the vessel wall was analyzed. RESULTS: MRI was feasible in all animals. Three days after injection of ferumoxytol the highest luminal signal intensity measurements were observed in the ferumoxytol group; the highest measurements were five days after injection in the ferumoxtran-10 group (P < 0.05). In the WHHL, susceptibility effects presented as homogeneous dark lines parallel to the aortic wall after ferumoxytol and spotted areas void of signal after ferumoxtran-10. None of these findings were observed in the NZW control groups. CONCLUSION: Ferumoxtran-10 and ferumoxytol at a respective dose of 250 mumol/kg appear well suited for atherosclerotic plaque detection with MRI in experimental atherosclerosis. Ferumoxytol warrants further analysis in humans.

Animals↗

Strengths and weaknesses of dark-lumen MR colonography: clinical relevance of polyps smaller than 5 mm in diameter at the moment of their detection.

PURPOSE: To assess the clinical relevance of dark-lumen MR colonography (MRC) for the detection of colorectal lesions using conventional colonoscopy (CC) and histopathologic examinations as reference standard. MATERIALS AND METHODS: A total of 72 patients underwent MRC and CC. MRC was performed using a contrast-enhanced high spatial resolution T1 weighted 3D volumetric interpolated breathhold examination (VIBE)-sequence. All removed colorectal lesions were evaluated by an experienced pathologist. RESULTS: CC confirmed 65 polyps less than 5 mm in diameter. Non of those lesions could be detected using MRC. Just two (4%) of the 49 removed lesions smaller than 5 mm showed signs of dysplasia. Additionally, CC confirmed 25 polyps between 6-15 mm in diameter (MRC 22). All those 25 lesions were removed in CC. Only four (16%) of those polyps showed signs of dysplasia and malignancy (11, 13, 13 and 15 mm). CONCLUSION: Dark-lumen MRC failed to detect all polyps smaller than 5 mm in diameter which are generally not clinically relevant at the moment of their detection and thus can be kept under surveillance. However, MRC as a non-invasive imaging modality is a promising alternative to CC in the detection of clinically relevant polyps larger than 5 mm in diameter.

Adult↗

Renal perfusion: comparison of saturation-recovery TurboFLASH measurements at 1.5T with saturation-recovery TurboFLASH and time-resolved echo-shared angiographic technique (TREAT) at 3.0T.

PURPOSE: To investigate the dependence of semiquantitative renal perfusion parameters on the acquisition technique and field strength used. MATERIALS AND METHODS: After intravenous injection of 7-mL Gd-chelates, high-temporal-resolution turbo fast low-angle shot (TurboFLASH) renal perfusion measurements were performed on eight healthy volunteers at 1.5T and another eight healthy volunteers at 3.0T. Another eight healthy volunteers were examined at 3.0T using time-resolved echo-shared angiographic technique (TREAT) after bolus administration of 7-mL Gd-chelates with a temporal resolution of 1.4 seconds. Analysis of the first-pass perfusion data yielded the following semiquantitative renal perfusion indices: mean transit time (MTT), time to peak (TTP), maximal upslope (MUS), and maximal signal intensity (MSI). RESULTS: MTT and TTP did not show significant differences between the different techniques. MSI and MUS were significantly (P < or = 0.002) higher with TREAT (591.1 a.u./second and 103.5 a.u./second) than with TurboFLASH at both field strengths (1.5T: 400.5 a.u./second and 65.4 a.u./second; 3.0T: 362.2 a.u./second and 68.7 a.u./second). CONCLUSION: Semiquantitative renal perfusion measurements are feasible with time-resolved echo-shared sequences and TurboFLASH techniques. While MTT and TTP appear to be independent of the technique and field strength applied, MUS and MSI are higher with TREAT.

Adult↗

Variability of preoperatively determined hepatic volumes in potential living liver donors.

RATIONALE AND OBJECTIVES: The aim of the study is to evaluate variability in hepatic volumes during the preoperative period in potential liver donors. MATERIALS AND METHODS: Eight potential living liver donors underwent preoperative multirow-detector computed tomographic assessment of hepatic transplant volumes twice. Intraindividual delay between the two examinations range was 3-62 days (mean, 30.1 days). Liver volumes were determined in a blinded fashion by an experienced radiologist and a transplantation surgeon. Results were compared and correlated with time of data acquisition during the day. RESULTS: Interobserver variability for assessments of liver volumes range was 6-32 mL (mean, 16 mL). Intraindividually, the difference between the two volume assessments ranged between -103 and +45 mL (mean, -19 mL), corresponding to percentages of alteration between -7.5% and +3.2%. There was no statistical correlation evident concerning volume alterations and specific time of data acquisition. CONCLUSION: Neither time of data acquisition nor waiting period for the surgical procedure seems to affect the accuracy of liver volume calculation. Apparent volume variations likely are in the range of the method error of the applied technique.

Adult↗

Analysis of cardiac function--comparison between 1.5 Tesla and 3.0 Tesla cardiac cine magnetic resonance imaging: preliminary experience.

PURPOSE: We sought to assess the feasibility of magnetic resonance imaging to evaluate cardiac function at 3.0 T compared with 1.5 T. MATERIAL AND METHODS: In a prospective intraindividual comparative study, 12 volunteers (range, 18-54 years), and 2 patients (range, 43-53 years) underwent cardiac cine magnetic resonance at both 3.0 T and 1.5 T. Data were acquired both with a steady-state free precession sequence (SSFP) and a spoiled gradient echo (SGE) sequence. If necessary, a frequency scout was used to correct for off-resonance artifacts. For both SSFP and SGE imaging, 6-mm thick retrospectively EKG-gated short axis views were acquired with equal matrix size (192 x 163) and comparable repetition time (TR). Cardiac function parameters were determined manually by a single investigator. Cardiac function parameters, signal to noise ratio (SNR), contrast to noise ratio (CNR), and the presence of artifacts were compared between the 2 magnetic field strengths. For statistical analysis, a Pearson's correlation coefficient was calculated, and a paired Student t test was used to test statistical significance. RESULTS: Very good correlations between cardiac function parameters at 1.5 T and 3.0 T (r > 0.84, P < 0.0011) were obtained. Compared with SGE, SSFP more frequently was prone to artifacts. With SSFP/SGE at 3.0 T, a SNR gain of 9.4/16% was achieved compared with 1.5 T. CONCLUSION: Functional cardiac cine magnetic resonance imaging can be regarded as equally accurate at 3.0 T compared with 1.5 T. Compared with SSFP imaging, the SGE sequence benefits more from higher field strengths and is less affected by artifacts.

Adolescent↗

High spatial-resolution CE-MRA of the carotid circulation with parallel imaging: comparison of image quality between 2 different acceleration factors at 3.0 Tesla.

PURPOSE: We sought to evaluate and compare the image quality and vessel delineation of the carotid arteries with high spatial-resolution contrast-enhanced MRA (CE-MRA) at 3.0 T using integrated parallel acquisition (iPAT) with acceleration factors of 2 and 4. MATERIALS AND METHODS: Using an 8-channel neurovascular array coil, we performed prospective high-spatial resolution CE-MRA at 3.0 T of the head and neck on 24 patients (11 men, 13 women, ages 37-89) with suspected arterio-occlusive disease who were assigned randomly to 2 groups. Twelve patients (group A) were examined with a 3D-GRE sequence using iPAT with acceleration factor of 2. For the next 12 patients (group B) a near-identical sequence with an acceleration factor of 4 was applied. Higher iPAT factors were used to increase the spatial-resolution while keeping scan time unchanged. Two volunteers were scanned by both protocols. Phantom measurements were performed to assess the signal-to-noise ratio (SNR). The presence of artifact, noise, image quality of the arterial segments, and the presence and degree of arterial stenosis were evaluated independently by 2 radiologists. Statistical analysis of data was performed by using Wilcoxon rank sum test and 2-sample Student t test (P < 0.05 was indicative a statistically significant difference). The interobserver variability was tested by kappa coefficient. RESULTS: SNR values were significantly lower when iPAT with acceleration factor of 4 was used (P < 0.001). There was no significant difference between 2 groups in regards to image noise (P = 0.67) and artifact (P = 0.8). Both readers visualized the majority of carotid circulation with good image quality in both groups. For smaller intracranial arteries, such as the second-division of anterior and middle cerebral artery, anterior communicating artery, and superior cerebellar artery, the image quality and vessel delineation was significantly better at an iPAT factor of 4 (P < 0.01). The overall interobserver agreement for both the vessel depiction, and detection of arterial stenoses was higher in group B compared with group A. CONCLUSION: Use of parallel acquisition techniques with a high acceleration factor (iPAT-4) results in superior depiction of small intracranial arterial segments. Imaging at higher magnetic field strength, in addition to the use of an optimized 8-channel array coil, provides sufficient SNR to support faster parallel acquisition protocols, leading to improved spatial-resolution. More extensive clinical studies are warranted to establish the range of applications and confirm the accuracy of the technique.

Adult↗

High-spatial-resolution contrast-enhanced MR angiography of abdominal arteries with parallel acquisition at 3.0 T: initial experience in 32 patients.

OBJECTIVE: The objective of our study was to evaluate an isotropic high-spatial-resolution 3D contrast-enhanced MR angiography (CE-MRA) protocol with high acceleration parallel acquisition at 3.0 T for the display of the abdominal vasculature. SUBJECTS AND METHODS: Thirty-two consecutive patients (13 men, 19 women; age range, 28-88 years) with suspected abdominal arterial disease underwent abdominal 3D CE-MRA on a 3.0-T MR system, using a high-spatial-resolution (0.7 x 0.82 x 0.8 mm3) 3D gradient-refocused echo (GRE) sequence, integrated with a generalized autocalibrating partially parallel acquisitions (GRAPPA) technique with an acceleration factor of 3. Two vascular radiologists evaluated image quality and the presence and degree of arterial stenoses. Interobserver variability was calculated, using the kappa coefficient. The sensitivity and specificity of the technique were calculated and comparative analysis was performed with those of conventional catheter angiography (in eight patients) as the standard of reference. RESULTS: The abdominal arterial vasculature was visualized with diagnostic image quality in all subjects. Arterial stenoses were detected in 148 and 142 arterial segments by observer 1 and observer 2, respectively, with good interobserver agreement (kappa = 0.75; 95% confidence interval [CI]: 0.69-0.81). The sensitivity and specificity values for CE-MRA for the detection of significant (> 50%) arterial stenoses were 100% and 96% for observer 1 and 100% and 92% for observer 2, respectively. There was a significant correlation between CE-MRA and conventional angiography (R = 0.96 and 0.93 for observers 1 and 2, respectively) for the assessment of the degree of stenosis. CONCLUSION: The outlined MR angiography protocol at 3.0 T combined with parallel acquisition technique renders highly reliable and isotropic high-spatial-resolution imaging of the abdominal vasculature.

Abdomen↗

Total-body 3D magnetic resonance angiography influences the management of patients with peripheral arterial occlusive disease.

High-resolution total-body 3D MR angiography (MRA) has recently become available, revealing additional clinically relevant disease in patients with peripheral arterial occlusive disease (PAOD). However, the actual impact of total-body MRA on patient management in patients with PAOD has not been investigated so far. Two hundred forty-nine consecutive patients with angiographically proven PAOD were prospectively examined by means of contrast-enhanced total-body 3D MRA on a 1.5-T MR scanner. All correlative imaging studies performed within 60 days of total-body MRA were included in the efficacy analysis. Additional clinically relevant disease (luminal narrowing >50%, aneurysmal changes or dissections) was found in 73 segments (52 patients), including the renal arteries (36 segments), carotid arteries (28 segments), subclavian arteries (four segments) and abdominal aortic aneurysms (AAA) (five segments). Of the 73 segments, 36 were deemed necessary for further investigation by means of focused MRA examinations; the diagnosis was confirmed in all cases. Within the 60-day follow-up period, interventional or surgical therapy outside the peripheral arterial tree was performed in nine patients (11 segments), including carotid endatherectomy and renal artery angioplasty. The outlined total-body 3D MRA approach permits a comprehensive evaluation of the arterial system in patients with atherosclerosis and does indeed have an impact on patient management in patients with PAOD.

Adult↗

Dark-lumen magnetic resonance colonography in patients with suspected sigmoid diverticulitis: a feasibility study.

To assess dark-lumen magnetic resonance colonography (MRC) for the evaluation of patients with suspected sigmoid diverticulitis. Forty patients with suspected sigmoid diverticulitis underwent MRC within 72 h prior to conventional colonoscopy (CC). A three-dimensional T1-weighted volumetric interpolated breath-hold examination sequence was acquired after an aqueous enema and intravenous administration of gadolinium-based contrast agents. All MRC data were evaluated by two radiologists. Based on wall thickness and focal uptake of contrast material and pericolic reaction including mesenteric infiltration on T1-weighted sequence the sigmoid colon was assessed for the presence of diverticulitis. MRC classified 17 of the 40 patients as normal with regard to sigmoid diverticulitis. However, CC confirmed the presence of light inflammatory signs in four patients which were missed in MRC. MRC correctly identified wall thickness and contrast uptake of the sigmoid colon in the other 23 patients. In three of these patients false-positive findings were observed, and MRC classified the inflammation of the sigmoid colon as diverticulitis whereas CC and histopathology confirmed invasive carcinoma. MRC detected additionally relevant pathologies of the entire colon and could be performed in cases where CC was incomplete. MRC may be considered a promising alternative to CC for the detection of sigmoid diverticulitis.

Aged↗

Magnetic resonance colonography without bowel cleansing using oral and rectal stool softeners (fecal cracking)--a feasibility study.

The aim of our study was to assess the effect of oral and rectal stool softeners on dark-lumen magnetic resonance (MR) colonography without bowel cleansing. Ten volunteers underwent MR colonography without colonic cleansing. A baseline examination was performed without oral or rectal administration of stool softeners. In a second set, volunteers ingested 60 ml of lactulose 24 h prior to MR examination. In a third examination, water as a rectal enema was replaced by a solution of 0.5%-docusate sodium (DS). A fourth MR examination was performed, in conjunction with both oral administration of lactulose and rectal application of DS. A T1-weighted data set was acquired at scanning times of 0, 5 and 10 min after colonic filling. A fourth data set was acquired 75 s after i.v. injection of contrast agent. Signal intensity of stool was calculated for all colonic segments. Without oral ingestion of lactulose or rectal enema with DS stool signal intensity was high and did not decrease over time. However, lactulose and DS caused a decrease in stool signal intensity. Both substances together led to a decreasing signal intensity of feces. Combination of lactulose and DS provided the lowest signal intensity of stool. Thus, feces could hardly be distinguished from dark rectal enema allowing for the assessment of the colonic wall.

Administration, Oral↗

Evaluation of steady state free precession imaging of the pancreas.

The aim of this work was to assess the diagnostic value of fast steady state free precession (SSFP) for the detection, characterization, and delineation of pancreatic lesions. Forty-eight patients referred for magnetic resonance (MR) imaging of the pancreas were included in the study. In addition to the standard protocol, axial pre-contrast SSFP slices of the pancreas were acquired. The standard of reference was defined as based on all imaging data other than SSFP, histopathology, surgery, and/or clinical follow-up. A randomized consensus reading of the SSFP data sets was retrospectively conducted by two board-certified radiologists. The presence of pancreatic lesions, local infiltration, and lymph node metastases was evaluated. Sensitivity and specificity were calculated and a receiver operating characteristic (ROC) analysis was performed. The overall sensitivity and specificity of SSFP were 0.93 and 0.77, respectively. Comparable values were achieved for lymph node detection (0.88/0.91) and assessment of vascular infiltration (0.94/0.91). The mean area under the ROC curve (Az) was 0.91. Owing to its potential to detect vascular infiltration and the rapid acquisition time, SSFP imaging should be supplemented as part of a standard MR protocol of the pancreas.

Contrast Media↗

Oral contrast agents for small bowel distension in MRI: influence of the osmolarity for small bowel distention.

To assess the effect of the osmolarity for small bowel distension in MRI, ten volunteers ingested at two separate occasions negative oral contrast agents with different quantity and osmolarity: (1) a water solution combined with 2.0% sorbitol and 0.2% locus bean gum (LBG) with a quantity of 1500 ml and an osmolarity of 148 mOsmol/l, (2) a water solution combined with 2.0% sorbitol and 2.0% barium sulphate with a quantity of 1000 ml and an osmolarity of 194 mOsmol/l. Small bowel distension was quantified on coronal 2D-TrueFISP images by measuring the small bowel diameters. There were no statistically significant differences in mean small bowel diameter between both contrast agents. The mean small bowel distension was 19.2 mm after ingestion of 1500 ml of sorbitol-LBG solution and 19.0 mm after ingestion of 1000-ml sorbitol-barium sulphate solution. Furthermore, all volunteers found the ingestion of 1000-ml solution more pleasant than the 1500-ml solution. The ingestion of 1000 ml of sorbitol-barium sulphate solution led to a sufficient small bowel distension compared to 1500 ml of sorbitol-LBG solution. The side effect rate of both solutions was low. Based on these data, we recommend a quantity of 1000 ml of sorbitol-barium sulphate solution as an alternative for 1500-ml sorbitol-LBG solution for optimal bowel distension.

Administration, Oral↗