PubMed Health⌕ Search

Biomedical subjects

Stefan Krämer

Publications and source records attributed to Stefan Krämer.

9 recordsLinked to original sources

Spontaneous acute dissection of the internal carotid artery: high-resolution magnetic resonance imaging at 3.0 tesla with a dedicated surface coil.

PURPOSE: Magnetic Resonance Imaging (MRI) has become the method of choice in the evaluation of patients with suspected cervical artery dissection (CAD). However, reliable identification of acute CAD might be impaired by the limited spatial resolution of standard 1.5 T MRI. In this preliminary study, we implemented a multicontrast high-resolution noninvasive vessel wall imaging approach at 3.0 T in patients with spontaneous CAD. METHODS AND MATERIALS: Ten patients with CAD of the internal carotid artery (ICA) were included in the study. 3.0 T MRI (Gyroscan Intera, Philips) was acquired using a dedicated phased-array coil. MRI-protocol consisted of: (1) bright blood 3D inflow MRA (TR/TE/FA = 25 milliseconds/3.1 millisecond/16 degrees , 120 slices, reconstructed voxel size 0.3 x 0.3 x 0.8 mm); (2) black blood cardiac-gated water-selective T1w 3D spoiled GE (TR/TE/FA = 31 milliseconds/7.7 milliseconds/15 degrees , 36 slices, 0.3 x 0.3 x 1.0 mm); and (3) black blood cardiac triggered fat suppressed T2w TSE (TR/TE/ETL = 3 heart beats/44 milliseconds/7, 18 slices, 0.3 x 0.3 x 2 mm). Three observers in consensus performed image analysis. Special attention was paid to the integrity of the luminal and adventitial vessel boundary and the presence of a communicating intimal tear or flap. RESULTS: 3.0 T MRI provided excellent delineation of vessel lumen and vessel wall as a result of the nearly complete suppression of arterial blood signal. An intramural hematoma could be identified in all patients, confined between the luminal and adventitial vessel boundary. In no patient a communicating intimal tear could be identified. Clear distinction between intramural hematoma and thrombus was possible. CONCLUSION: High-resolution vessel wall imaging in patients with acute CAD is feasible. The increased signal-to-noise ratio at 3.0 T can be invested to obtain a higher spatial resolution, permitting depiction of intimal and adventitial vessel wall boundary and the intramural hematoma in the diseased vessel segment. The morphologic information that is gained is helpful in the understanding of the underlying pathomechanismen of CAD.

Adult↗

FLAIR imaging for multiple sclerosis: a comparative MR study at 1.5 and 3.0 Tesla.

The purpose of this study was (1) to identify the optimal TE for FLAIR-imaging at 3.0 T assessing three different echo times qualitatively and quantitatively and (2) to evaluate the diagnostic efficacy of high-field 3.0-T FLAIR imaging in comparison to conventional 1.5-T MRI in patients with multiple sclerosis (MS). Twenty-two patients with clinically definite MS underwent axial FLAIR imaging at 1.5 and 3.0 T. In 15 of these patients further FLAIR images with a TE of 100, 120 and 140 ms were acquired at 3.0 T. Imaging protocols were modified for 3.0 T using the increased SNR to acquire more and thinner slices while maintaining a comparable scan time. FLAIR images of either different TEs or different field strengths were ranked for each patient qualitatively by two observers. Signal intensity measurements were obtained in the gray and white matter, CSF and representative white matter lesions (WML). At 3.0 T, a TE of 100 and 120 ms proved superior in all qualitative categories when compared to 140 ms. In the quantitative assessment CNR of WML was highest for 120 ms (CNR: 19.8), intermediate for 100 ms (17.2) and lowest for 140 ms (15.3) (P<0.003). For lesion conspicuity and overall image quality, 3.0 T was judged superior to 1.5 T, whereas no difference was found for gray-white differentiation and image noise. With regard to artifacts, 3.0 T was inferior to 1.5 T. The CNR for WML was slightly lower at 3.0 T, but the difference was not significant (22.6 vs. 28.0, P=ns). However, significantly more WML were detected at 3.0 T than at 1.5 T (483 vs. 341, P<0.0001). The optimal echo time for FLAIR imaging at 3.0 T is 120 ms due to the significantly higher CNR of WML. By trading the higher SNR at 3.0 T for better spatial resolution, nearly the same CNR level could be maintained, increasing lesion detectability at 3.0 T compared to 1.5 T. Thus, high-field MRI may further strengthen the role of MRI as the most sensitive paraclinical test for the early diagnosis of MS.

Adult↗

3.0 T vs. 1.5 T MR angiography: in vitro comparison of intravascular stent artifacts.

PURPOSE: To evaluate the signal characteristics of different iliac artery stents in MR angiography (MRA) at 3 T in comparison with 1.5 T. MATERIALS AND METHODS: Sixteen iliac artery stents were implanted in plastic tubes filled with a solution of Gd-DTPA and imaged at 3 T and 1.5 T using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis included a subjective assessment of artifact characteristics, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements in stented and unstented vessel parts, and quantitative measurements of total artifact size. RESULTS: The pattern of stent artifacts inside the stents evidently did not differ at 3 T and 1.5 T. The average total size of the artifact areas surrounding the stents was significantly larger at 3 T (P < 0.03). However, within the stented part of the vessel phantom, the signal of the lumen and its contrast to modeled surrounding tissue was significantly higher at the higher field. The mean SNR of the lumen increased from 95.5 at 1.5 T to 127.3 at 3 T, and the CNR of the vessel increased from 70.3 to 93. CONCLUSION: Assessment of the stent lumen in iliac artery stents in a phantom model is not compromised by imaging at 3 T compared to 1.5 T. The signal gain inside the stented part of the vessel lumen at higher field compensates for the higher degree of stent artifacts seen in stents made of steel or cobalt.

Artifacts↗

Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique.

OBJECTIVE: The aim of this study was to compare the visualization of different coronary artery stents and the detectability of in-stent stenoses during 4-slice and 16-slice computed tomography (CT) angiography in a vessel phantom. MATERIAL AND METHODS: Ten coronary stents were introduced in a coronary artery vessel phantom (plastic tubes with an inner diameter of 3 mm, filled with iodinated contrast material diluted to 220 Hounsfiled Units [HU], surrounded by oil [60 HU]). CT scans were obtained perpendicular to the stent axes on a 4-slice scanner (detector collimation 4x1 mm; table feed 1.5 mm/rotation, mAs 300, kV 120, medium-smooth kernel) and a 16-slice scanner (detector collimation 12x0.75 mm; table feed 2.8 mm/rotation, mAs 370, kV 120, reconstruction with a standard and an optimized sharp kernel). Longitudinal multiplanar reformations were evaluated regarding visible lumen diameters and intraluminal attenuation values. Additionally, the stents were scanned with the same parameters after implantation of 60% stenoses (HU 30). RESULTS: Using the same medium-smooth kernel reconstruction with 4-slice and 16-slice CT, there was a slight increase in the average visible lumen area (26% versus 31%) and less increase of average intraluminal attenuation values (380 HU versus 349 HU). Significant improvement of lumen visualization (54%, P<0.01) and attenuation values (250, P<0.01) was observed for the 16-slice scans using the sharp kernel reconstruction. In-stent stenoses could be more reliably identified (or ruled out) by 16-slice CT and sharp reconstruction kernel when compared with the other 2 methods. CONCLUSION: 16-slice CT using a dedicated sharp kernel for image reconstruction facilitates improved visualization of coronary artery stent lumen and detection of in-stent stenoses.

Coronary Angiography↗

Thromboembolic complications after endovascular aortic aneurysm repair.

PURPOSE: To evaluate the frequency and significance of thromboembolic complications following endovascular treatment of aortic aneurysms. METHODS: One hundred seventy-four patients (153 men; mean 71.4 years, range 26-90) underwent endovascular repair of aneurysms of the thoracic (n = 38) or abdominal (n = 136) aorta using a variety of endografts. All patients were examined preprocedurally using 3-phase helical computed tomography (CT) to determine appropriate endograft size. To exclude the occurrence of infarction in parenchymal organs, the first postprocedural CT scan was compared with preoperative findings. Newly recognized perfusion deficits were taken as evidence of procedure-related infarction. RESULTS: Infarctions were detected in 16 (9.2%) patients: 13 in the kidneys, 2 in the spleen, with 1 in the mesentery; only the mesenteric infarction was clinically symptomatic. Both splenic infarctions were associated with deployment of stent-grafts in the thoracic aorta (5.3% of the 38 patients), while the mesenteric and 13 renal infarctions were seen in patients with infrarenal abdominal aortic aneurysms (0.7% and 9.6%, respectively, of 136 patients). One patient experienced complete thromboembolic occlusion of a renal artery, which was partially recanalized with intraoperative lysis. CONCLUSIONS: Thromboembolic complications of endovascular aortic aneurysm repairs are not uncommon, and although usually asymptomatic, these sequelae have the potential to be life threatening. Perfusion abnormalities may respond to immediate lytic therapy with complete dissolution of the thrombus in certain isolated cases.

Aged↗

Initial experience with intentional stent-graft coverage of the subclavian artery during endovascular thoracic aortic repairs.

PURPOSE: To investigate the extent to which clinical status is affected by covering the left subclavian artery (LSA) with stent-grafts in the thoracic aorta. METHODS: Stent-graft reconstruction of the thoracic aorta was performed in 23 patients (20 men; mean age 50.8 years, range 17-77) for management of rupture (n = 11), type B dissection (n = 9), or aneurysm (n = 3). All patients had bilaterally equal systolic and diastolic blood pressures (141.3+/-19.8 and 78.9+/-11.0 mmHg, respectively). Twenty Gore TAG and 1 Talent thoracic endografts were used; 2 cases required a combination of prostheses. In all patients, the stent-graft was intentionally placed to cover the LSA. Follow-up included clinical examination with blood pressure measurements and computed tomography during the first postoperative week and at 3-month intervals thereafter. RESULTS: After coverage of the LSA by the stent-graft, systolic pressure fell by a mean 48.3+/-23.4 mmHg. In 4 cases of proximal endoleak, however, systolic pressure fell by only 25.0+/-15.0 mmHg. Twenty (78.5%) patients reported no complaints during a mean follow-up of 12.1+/-7.3 months. Postinterventional complaints reported by 3 patients included exercise-dependent paresthesias; nonexercise-dependent, intermittent, and completely reversible dizziness; and a temperature difference between the upper extremities with no decrease in strength. CONCLUSIONS: Covering the LSA is generally well tolerated by patients and increases the landing zone for the placement of thoracic stent-grafts. Long-term studies, however, must investigate the hemodynamic effects of this procedure on the vertebrobasilar circulation.

Adolescent↗

Prognostic significance of serum HER2 and CA 15-3 at the time of diagnosis of metastatic breast cancer.

BACKGROUND: Serum HER2 testing allows the determination of real-time HER2 status during clinical course. The aim of this investigation was: (1) to study the prognostic significance of serum HER2 at the time of first diagnosis of metastatic breast cancer and (2) to evaluate its relationship to CA15-3 which is a surrogate marker for tumor load. MATERIALS AND METHODS: Serum samples of 120 breast cancer patients were assayed for HER2 and CA15-3 at the onset of metastatic disease. RESULTS: Forty-seven out of 120 (39%) metastatic breast cancer patients had elevated serum HER2 levels. The positivity rate of CA15-3 was 51%. The median survival after relapse (SAR) for HER2-positive patients was shorter (10 months, 95%-CI: 6-14 months) compared to the SAR of HER2-negative patients (19 months, 95%-CI:15-23 months) (p<0.01). The median survival of patients with increased CA15-3 was 13 months (95%-CI: 9-17 months) compared to 18 months (95%-CI: 15-21 months) for patients with normal CA15-3 concentrations (p<0.05). In the multivariate analysis serum HER2 was an independent prognostic marker for SAR even when adjusted for tumor load measured by CA15-3 levels. CONCLUSION: Serum HER2 is a strong independent prognostic factor for survival after relapse in metastatic breast cancer even when adjusted for tumor load. Therefore, the prognostic significance of serum HER2 may not only be related to the tumor load but also to the biological behavior of the tumor.

Biomarkers, Tumor↗

Evaluation of CA125, physical and radiological findings in follow-up of ovarian cancer patients.

The majority of ovarian cancer patients will suffer from intraabdominal relapse within the first five years after surgery. Today various diagnostic tools, including ultrasound or CT, are available to detect an ovarian cancer recurrence. Radiological examinations at regular time-intervals may lead to the detection of tumor relapse, however these procedures have limited sensitivity and specificity. Moreover, imaging procedures are costly. CA125 is a tumor marker with high sensitivity in ovarian cancer patients. Tumor marker determination is a simple, reproducible technique, and may therefore be useful in routine follow-up in ovarian cancer patients, supplemented with additional imaging procedures. In a retrospective analysis of 58 patients with recurrent ovarian cancer, the sensitivity of clinical examination and tumor marker analysis was compared to radiological findings. Physical interview and physical examination were performed for all patients. CA125 levels were determined in 54 out of 58 patients at the time of diagnosis of recurrence. Forty-seven out of 58 patients received a vaginal ultrasound and 42 were examined by CT scan. In 45 out of 54 (83%) patients, CA 125 was elevated at the time of recurrence. In 45 out of the 58 (78%) patients, a tumor was detected by physical examination. Forty-two out of the 58 patients had CT scans. Pathological findings were seen in 33 out of these patients (80%) Ultrasound revealed tumor recurrence in 33 out of 47 patients (70%). By a follow-up based on physical examination and CA125 determination, 53 out of 54 (98%) patients with recurrences could be identified. In patients with a pelvic recurrence, vaginal examination had the highest sensitivity in comparison to vaginal ultrasound and CT scan. Imaging techniques did not add clinically relevant information during follow-up and should therefore only be performed prior to surgical or therapeutical intervention.

Biomarkers, Tumor↗