Marked improvement in left ventricular function and significant reverse left ventricular remodeling within 3 months of cardiac resynchronization therapy in patients with dilated cardiomyopathy.

We monitored reverse left ventricular (LV) remodeling and LV function during the first 6 months of cardiac resynchronization therapy (CRT) in 34 patients (mean age = 55.3 +/- 13.6 years, 28 men) with dilated cardiomyopathy (DCM), left bundle branch block, in stable New York Heart Association class III, and on fixed drug regimen who underwent implantation of CRT systems with or without cardioverter defibrillator back-up. QRS-complex duration was reduced from 169.69 +/- 19.6 ms (SD) to 144.1 +/- 23.4 ms during CRT. Parasternal M-mode and apical 2D-echocardiography was performed before and 3 and 6 months after device implantation. LV enddiastolic (EDD) and endsystolic (ESD) diameters were measured, and biplane LV enddiastolic (EDV), and endsystolic (ESV) volumes and ejection fractions (EF) were calculated using a modified Simpson formula. Significant decreases in LVEDD (P = 0.0064 at 3 months and P = 0.021 at 6 months), LVESD (P = 0.023 at 3 months, and P = 0.003 at 6 months), and LVESV (P = 0.006 resp. P = 0.007), and increases in LVEF (P = 0.003 at 3 months and P < 0.001 at 6 months) were observed. Mean LVEF increased from 23% at baseline to 39% at 6 months. CRT induced prominent reverse LV remodeling and significantly increased LVEF within a few months in patients with DCM.

Cardiac Pacing, Artificial↗

Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients.

BACKGROUND: Although more than 150,000 implantable cardioverter defibrillators (ICDs) are implanted yearly worldwide, only few studies systematically examined complications of ICD therapy in large patient cohorts. METHODS: We prospectively analyzed ICD-related complications in 440 consecutive patients who underwent first implantation of an ICD system for primary or secondary prevention of sudden cardiac death within the last 10 years at our institution. All study patients received pectoral nonthoracotomy ICD lead systems with the exception of one patient who had an artificial tricuspid valve. RESULTS: During 46 +/- 37 months follow-up, 136 of 440 patients (31%) experienced at least one complication including implant procedure-related complications in 43 patients (10%), ICD generator-related complications in 28 patients (6%), lead-related complications in 52 patients (12%), and inappropriate shocks in 54 patients (12%). The most serious complications included one perioperative death due to heart failure (0.2%), two ICD system infections necessitating device removal (0.5%) and two perioperative cerebrovascular strokes (0.5%). CONCLUSIONS: We conclude that more than one quarter of ICD patients experience complications during a mean follow-up of almost 4 years, although serious complications such as intraoperative death or ICD system infections are rare in patients with nonthoracotomy ICD systems. Recognition of these complications is the prerequisite for advances in ICD technology and management strategies to avoid their recurrence.

Death, Sudden, Cardiac↗