Simplified analysis of mixtures of small molecules by chromatographic NMR spectroscopy.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Stefano Caldarelli.
Explore the source record for details and available documents.
We tested the potential of High-Resolution MAS NMR spectroscopy to study 20 samples of Emmental cheeses from 7 different geographical regions. Principal component analysis (PCA) and discriminant analysis (DA) were used to analyze the data set of 1H HRMAS NMR spectra and succeeded in grouping the studied samples according to their geographical origins.
The diffusional properties of molecules in solution vary dramatically upon addition of a solid chromatographic phase. This effect can be monitored via pulsed-gradient spin-echo NMR used in conjunction with moderately fast rotation of the sample (high-resolution magic angle spinning) to produce exploitable spectra. The molecular diffusion coefficients observed in this condition are averages reflecting the equilibrium population distribution among the different phases. It is thus possible to use this information for investigating a crucial step of reversed-phase chromatography, namely, the partitioning of the analyte between different phases. In this work, we describe the evolution of the apparent diffusion coefficient of typical solutes for water/acetonitrile solvent mixtures of varying proportions.
Analytical methods based on solid-state NMR are becoming increasingly popular. However, these flourishing activities bring up the issue of how accurately NMR can assess an analyte proportion in a solid sample. The use of a chemical intensity reference for this purpose is a natural but often unsuitable choice, due to sample stability or preciousness. We propose here a protocol to perform quantitative measurements in solid-state NMR, by calibration of the circuit response through a low-power pulse injected during the acquisition (the so-called ERETIC method). Although this method has been in use for some time in liquid-phase and in vivo NMR, we point out here some peculiarities and useful applications typical of solids. Namely, the temperature dependence of the signal intensity imposes care in the application to MAS experiments.
We performed a preliminary NMR investigation on grated Parmigiano Reggiano cheese of different ripening ages. Principal component analysis (PCA) and discriminant analysis (DA) were able to successfully group the analyzed samples according to their respective ages.
High-resolution magic angle spinning (HRMAS) NMR is probably the most apt NMR method to analyze complex materials involving a solid phase, e.g. foodstuffs. We present here an HRMAS analysis of grated cheese (Parmigiano Reggiano). A full NMR characterization of this cheese allows the identification of the presence of fatty acids (saturated and unsaturated), amino acids and other small organic molecules. Since the presence and relative concentration of these molecules have previously been shown to correlate with organoleptic, origin and age characterization, HRMAS NMR of cheese is likely to provide a good complimentary tool for the analysis of this food material.
We introduce an analytical method that combines in one pot the advantages of column chromatography separation and NMR structural analysis. The separation of the NMR spectra of the components of a mixture can be achieved according to their apparent diffusion rates [James, T. L. and McDonald, G. G. (1973) J. Magn. Reson. 58, 58-61]. We show that the separation of the spectral components, corresponding to single molecular species, can be enhanced by order of magnitudes upon addition of a typical stationary phase used in HPLC. The solid phase imbibed by the mixture for analysis is an heterogeneous ensemble, so that solid-state NMR methods (high-resolution magic angle spinning) are necessary to recover high-resolution spectra. We demonstrate applications of this combination of high-resolution magic angle spinning and NMR diffusometry on test mixtures for direct (silica gel) and inverse (C18) columns. However, many common chromatographic supports available for HPLC should be readily adaptable for use with this technique.