Enhanced Glaucoma Staging System (GSS 2) for classifying functional damage in glaucoma.

PURPOSE: To introduce a new method, derived from the Glaucoma Staging System (GSS), for classifying glaucomatous visual field defects. PATIENTS AND METHODS: Four sample groups composed respectively of 471 (sample #1), 128 (sample #2), 185 (sample #3), and 131 (sample #4) patients with either ocular hypertension or chronic glaucoma were considered. The GSS 2 uses both the MD and CPSD/CLV or PSD/LV perimetric indices to classify visual field defect in 6 stages and in 3 types (generalized, localized, and mixed). The formulas were determined using sample #1. A new borderline stage was created, on the basis of sample #2. The relationship between the PSD/LV and CPSD/CLV values was studied on sample #3 to verify the possibility of using the uncorrected indices instead of the CPSD/CLV. The relationship with other classification methods was studied on sample #4. RESULTS: The GSS 2 showed a strong level of association with the AGIS and the Hodapp-Parrish-Anderson methods in staging defect severity. A good correlation was also found with a classification based on the Bebie curve. CONCLUSIONS: The GSS 2 was able to correctly classify both damage severity and perimetric defect type in the sample studied, using either the corrected or uncorrected visual field indices. It is a quick and easy method, and its formulas can be introduced in any software.

Adult↗

Lens epithelial cell reaction after implantation of different intraocular lens materials: two-year results of a randomized prospective trial.

PURPOSE: To determine the influence of intraocular lens (IOL) material on anterior capsular opacification and membrane growth over the anterior IOL surface in patients who have undergone standardized small-incision cataract surgery and foldable IOL implantation in the capsular bag. DESIGN: Randomized controlled trial. PARTICIPANTS: Eighty-eight cataract patients (88 eyes). METHODS: Patients were randomly assigned to receive one of four different foldable IOLs after phacoemulsification: Storz Hydroview H60M, Corneal ACR6D, AMO SI40NB, and Alcon AcrySof MA60BM. Examinations on days 7, 30, 90, 180, 360, and 720 after surgery included ophthalmologic examination, slit-lamp biomicroscopy, and photography using red reflex and focal illumination of the anterior IOL surface. MAIN OUTCOME MEASURES: Best-corrected visual acuity was measured at each examination. In addition, the anterior capsule opacification and the membrane growth on the anterior IOL surface were graded according to a subjective method by the same researcher. RESULTS: The fibrosis of the anterior capsule was more frequently observed in the group using Corneal ACR6D and AMO SI40NB. The Hydroview and ACR6D groups showed a higher percentage of cases with membrane growth from the rhexis edge on the anterior IOL surface. AcrySof showed the lowest presence of fibrosis of the anterior capsule, and no membrane growth was noted. CONCLUSIONS: Anterior capsule opacification is an index of IOL biocompatibility. The natural location of lens epithelial cells (LECs) precludes the possibility of the IOL's design influencing the anterior capsule behavior. The local response of LECs varies according to the IOL studied. This may be related to the chemical and physical properties of the materials used in the different IOLs.

Adult↗