PubMed Health⌕ Search

Biomedical subjects

Stellan Hjertén

Publications and source records attributed to Stellan Hjertén.

11 recordsLinked to original sources

Universal method for synthesis of artificial gel antibodies by the imprinting approach combined with a unique electrophoresis technique for detection of minute structural differences of proteins, viruses, and cells (bacteria). III: gel antibodies against cells (bacteria).

Artificial antibodies in the form of gel granules were synthesized from the monomers acrylamide and N,N'-methylenebisacrylamide by the imprinting method in the presence of Echerichia coli bacteria as template. The electrophoretic migration velocities of the gel antibodies (i) saturated with the antigen (Escherichia coli MRE-600), (ii) freed of the antigen, and (iii) resaturated with bacteria, were determinated by electrophoresis in a rotating narrow-bore tube of 245 mm length and the 2.5 and 9.6 mm inner and outer diameters, respectively. Removal of bacteria from the gel antibodies was made by treatment with enzymes, followed by washing with SDS and buffer. Gel granules becoming charged by adsorption of bacteria move in an electrical field. We obtained a significant selectivity of gel antibodies for E. coli MRE-600, since the granules did not interact with Lactococcus lactis; and when E. coli BL21 bacteria were added to the gels selective for E. coli MRE-600, a significant difference in the migration rate of the complexes formed with the two strains was observed indicating the ability of differentiation between the two strains. The gel antibodies can be used repeatedly. The new imprinting method for the synthesis of artificial gel antibodies against bioparticles described herein, and the classical electrophoretic analysis technique employed, thus represent - when combined - a new approach to distinguish between different types and strains of bacteria. The application area can certainly be extended to cover other classes of cells.

Acrylamide↗

CE to monitor endotoxins by protein complexation.

A new CE method for fast and efficient analysis of bacterial endotoxins (lipopolysaccharides) is described. It is based on the strong interaction between proteins and endotoxins. The UV absorption of the protein component in the complex is used for the detection. The electrophoretic mobility of the complex hemoglobin/endotoxin can be employed for qualitative analysis of the endotoxin. For instance, the structural differences between "smooth" and "rough" lipopolysaccharides from Salmonella minnesota (wild-type), Salmonella minnesota R595 and Shigella sonnei R562H are reflected in the electrophoretic mobilities of their hemoglobin complex.

Bacterial Toxins↗

Monolithic beds of artificial gel antibodies.

The introductions of the continuous beds, now often called monoliths [S. Hjertén, J.-L. Liao, R. Zhang, J. Chromatogr. 473 (1989), 273-275] and the artificial, highly selective gel antibodies against antigens as large as proteins, viruses and cells [J.-L. Liao, Y. Wang, S. Hjertén, Chromatographia 42 (1996), 259-262] were breakthroughs in the design of chromatographic beds. This paper deals with a combination of these two methods, i.e., the artificial gel antibodies have been synthesized in the monolithic mode. As antigen we have used human hemoglobin. A comparison of the ion-exchange chromatograms of the eluates from the monolithic columns shows that the monolith prepared in the presence of hemoglobin adsorbed this protein, but not the other proteins in the sample (ribonuclease A and cytochrome c), i.e., this monolith was selective for hemoglobin, whereas the blank column (prepared in the absence of hemoglobin) had no selective properties, since none of the applied proteins were adsorbed. The diameter of the column was 6mm, but the same approach to synthesize a monolithic selective bed can very likely also be used for capillaries and microchips.

Antibodies↗

Influence of ignored and well-known zone distortions on the separation performance of proteins in capillary free zone electrophoresis with special reference to analysis in polyacrylamide-coated fused silica capillaries in various buffers. I. Theoretical studies.

Distortion of the starting zone upon its electrophoretic migration toward the detection window gives rise to both symmetrical zones caused by diffusion, sedimentation in the horizontal section of the capillary and the curvature of the capillary, and asymmetrical zones having their origin in Joule heating, sedimentation in the vertical section of the capillary, pH and conductivity differences between the sample zone and the surrounding buffer, solute adsorption onto the capillary wall, and association-dissociation of complexes between the analyte and a buffer constituent or between analytes. Interestingly and importantly a theoretical study shows that moderate pH and conductivity differences as well as adsorption and all of the above interactions when they are characterized by a fast on/off kinetics do not increase the zone broadening (or only slightly), because the sharpening of one boundary of the zone is about the same as the broadening of the other boundary. In addition the peak symmetry caused by a conductivity difference is in most experiments counteracted by a pH difference. The experimentally determined plate numbers in the absence of electroosmosis exceeded one million per meter in some experiments (Part II). These plate numbers are among the highest reported [Z. Zhao, A. Malik, M.L. Lee, Anal. Chem. 65 (1993) 2747; M. Gilges, K. Kleemiss, G. Schomburg, Anal. Chem. 66 (1994) 2038; H. Wan, M. Ohman, L.G. Blomberg, J. Chromatogr. A 924 (2001) 591 (plate numbers determined in the presence of electroosmosis may be higher, although the width of the zone in the capillary may be larger) [p. 680 in S. Hjertén, Electrophoresis 11 (1990) 665]). Capillary free zone electrophoresis is perhaps the only separation method, which, under optimum conditions, gives a plate number not far from the theoretical limit. A prerequisite for this high performance is that the polyacrylamide-coated capillary is washed with 2 M HCl between the runs and stored in water over night (Part II). The difference between the experimentally determined total variance and the sum of the calculated variances originating from the width of the starting zone, longitudinal diffusion, Joule heating, sedimentation in the vertical section of the capillary, curvature of the capillary (i.e., the sum of all other variances) was in our most successful experiments about 28% of the variance of diffusion. The zone broadening, 2sigma, caused by diffusion was estimated at 0.77 mm. The total zone width (2sigma) calculated from the experimentally determined plate number was as small as 1 mm when the migration distance was 40 cm. Accordingly, the only efficient way to reduce drastically the total zone width is to decrease the analysis time and, thereby, the diffusional broadening. An important finding was that the variance originating from the loops of the capillary is not always negligible in high-performance runs. Therefore, one should employ straight capillaries and avoid CE apparatus with cartridges that require a strong curvature of the capillary, common in most commercial instruments. Mathematical formulas have been derived for the sedimentation of the solute zone, the enrichment factor, and the migration time in experiments where the solute is dissolved in a dilute running buffer. This zone sharpening method gave very narrow starting zones (0.04-0.4 mm). However, upon high dilution of the buffer the enrichment becomes so strong that part of the sample zone probably sediments out of the capillary; the almost inevitable change in pH may decrease the mobility of the proteins and, thus, cause the enrichment factor to become still lower than expected. Diffusion of the protein in the very narrow starting zone (located close to the tip of the capillary) and sometimes the thermal expansion of the buffer in the capillary contributes to additional loss of protein in the enrichment step. In some buffers, the interaction between the protein and the buffer constituents is so slow that the peaks become broad. Therefore, different types of buffers should be tested when high resolution is required. The relation sigma2 (the variance of the interaction between a protein and the buffer constituents) = constant x u (the mobility) seems to be valid for all proteins in the applied sample, at least when they have similar molecular masses. To facilitate the understanding of the progress of a free zone electrophoresis experiment, we have discussed in simple terms how the concentrations of the background electrolytes become rearranged during a run and why the difference between the mobilities of the proteins and the mobilities of the background electrolyte determines whether a peak exhibits fronting or tailing. A theoretical analysis of zone broadening in capillary zone electrophoresis, chromatography, and electrochromatography indicates that electrochromatography in homogeneous gels might be the only chromatographic technique which can compete in performance with free electrophoresis. Using an equation, valid not only for electrophoresis, but also for chromatography and centrifugation, the mobility of a concentration boundary has been calculated for the first time and was, as expected, low. Equations based on the Kohlrausch regulating function do not permit such calculations. Another regulating function (the H function) and some of its characteristics are briefly discussed. The theoretical discussions in this paper and the experimental studies in Part II show that high-performance electrophoresis deserves its prefix when the runs are designed to give minimum zone broadening. Some guidelines are given to facilitate this optimization. The plate numbers are so high that the resolution cannot be increased by more than 30% even if they approach the theoretically maximum values.

Acrylic Resins↗

Influence of ignored and well-known zone distortions on the separation performance of proteins in capillary free zone electrophoresis with special reference to analysis in polyacrylamide-coated fused silica capillaries in various buffers. II. Experimental studies at acidic pH with on-line enrichment.

The separation of acidic and basic model proteins was studied in capillary free zone electrophoresis in a polyacrylamide-coated, electroosmosis-free capillary at pH below their isoelectric points (pI) using various buffers at pH 2.7-4.8 with UV detection at 200 nm. The separation performance was significantly dependent on the coating quality, which may even differ within the same batch of capillaries. In addition, a washing step with 2 M HCl and the storage of the capillary in distilled water was essential for the performance. For high efficiency and resolution the choice of buffer constituents was extremely important which is discussed in quantitative terms in Part I. The most promising buffers were ammonium acetate and ammonium hydroxyacetate at pH 4 (ionic strengths: 0.12 and 0.15 M, respectively) with plate numbers up to 1,700,000 plates/m, corresponding to a zone width (2sigma) of only 1 mm in a capillary with 40 cm effective length, when the injected samples were dissolved in a 10-fold diluted background electrolyte (BGE), a zone even narrower than those obtained in polyacrylamide gel electrophoresis, the characteristic feature of which is remarkably thin zones. In the experiment giving this plate number, the calculated variance for longitudinal diffusion was larger than all the other calculated variances (those for the width of the starting zone, Joule heating, sedimentation and the curvature of the capillary). Interestingly, the effect of capillary curvature was significant. In addition, the sum of all other imaginable variances (corresponding to various types of slow on/off kinetics and hyper-sharp peaks) was in the most successful experiments only 28-50% of the variance for longitudinal diffusion. One hundred- to two hundred-fold dilution of the BGE improved the detection limits and provided high precision in both migration times and peak areas with ammonium hydroxyacetate and ammonium acetate as background electrolytes. However, that high dilution increased the variance 140-400% for these buffers, respectively, at least partly due to conductivity or pH differences between the sample and buffer zones (hyper-sharp peaks). Sedimentation of the enriched sample, a factor that has not previously been treated theoretically or experimentally, was probably another reason for our finding that peak heights did not increase when the sample was dissolved in a buffer diluted more than 200-fold, although pH changes and in some cases thermal expansion in the capillary also may contribute. Loss of protein may occur at the ionic strength 0.01 and lower due to precipitation. Limits of detection were in the range 4-17 pmol of proteins with ammonium acetate as BGE. No indication of denaturation of proteins at pH 4 was observed. However, the separation performance at pH 3 was not satisfactory and loss of proteins was observed, possibly indicating such problems. The protein mobilities decreased unexpectedly from pH 4 to 3--a further indication of conformation changes.

Acrylic Resins↗

Hybrid microdevice electrophoresis of peptides, proteins, DNA, viruses, and bacteria in various separation media, using UV-detection.

Recently we described the design of a hybrid microdevice for micro(nano)electrophoresis and electrochromatography, discussed its advantages and disadvantages compared to conventional microdevices and presented a few applications with low-molecular-weight samples. In this paper, we demonstrate the broad application range of this device using UV-based analyses of (i) peptides by free-zone electrophoresis and electrophoresis in a recently introduced gel (polyacrylamide cross-linked with allyl-beta-cyclodextrin), (ii) proteins by electrophoretic molecular-sieving in a polymer solution supplemented with SDS, (iii) DNA fragments by electrophoresis in the above gel, (iv) virus particles in this gel, as well as in free buffer and (v) bacteria in free buffer. To illustrate the advantages of the hybrid microdevice we can mention that electrophoresis of proteins in a polymer-containing buffer, supplemented with sodium dodecyl sulfate (SDS), in a 4.30 (2.75) cm long channel gave a resolution similar to that in conventional capillary electrophoresis in a 23.5 (18.6) cm long capillary and analysis times which were 15-fold shorter.

Bacteria↗

High-resolution capillary zone and gel electrophoresis of structurally similar amphipathic glutathione conjugates based on interaction with beta-cyclodextrins.

The tripeptide glutathione is a prominent intracellular constituent that provides protection against genotoxic and carcinogenic electrophiles and is also a component of several biological signal substances. Glutathione conjugates, free glutathione, and glutathione disulfide contain charged amino acid residues, which contribute to solubility in aqueous media. However, the amphipathic nature of glutathione conjugates and the small differences that may distinguish the S substituents, pose analytical problems in their resolution. The present study demonstrates how homologous S-alkyl and S-benzyl conjugates of high structural similarity can be efficiently resolved by capillary electrophoresis. Inclusion of beta-cyclodextrins in the buffer or in a polyacrylamide gel affords baseline separation of the analytes. The separation methods described are applicable to enzyme assays in vitro and to the identification and quantification of glutathione conjugates of importance in toxicology and physiology. The contribution of beta-cyclodextrin to the separation is primarily based on interactions between its hydrophobic cavity and the S-alkyl and S-benzyl groups of the analytes.

Alkylation↗

Stable homogeneous gel for molecular-sieving of DNA fragments in capillary electrophoresis.

A polyacrylamide gel crosslinked with allyl-beta-cyclodextrin can be used repeatedly for several weeks for the separation of DNA fragments, since bubbles are not generated during a run. Allyl-beta-cyclodextrin can easily be synthesized in one step from allylglycidylether and beta-cyclodextrin. The plate numbers for DNA fragments, up to about 1500 bp, are high: for the separation of pBR322/HaeIII fragments they were in the range 450,000-1,600,000 m(-1). The resolution was almost independent of the concentration of the crosslinker (allyl-beta-cyclodextrin)--in sharp contrast to gels crosslinked with N,N'-methylenebisacrylamide.

Base Pairing↗

A hybrid microdevice for electrophoresis and electrochromatography using UV detection.

We have designed a new class of microdevices composed of a supporting plastic (polyvinyl chloride, PVC) plate integrated with a groove for a piece of fused silica capillary (the separation channel), a slit for on-tube detection, an "islet" for the application of sample, electrode vessels and platinum electrodes. The design permits electrophoretic, electrochromatographic and chromatographic separations with on-tube UV detection. The efficient heat dissipation allows relatively high field strengths. This article is the first one dealing with microdevices where polymer solutions are replaced by homogeneous gels. A new type of gels synthesized from acrylamide and 2-hydroxy-3-allyloxy-propyl-beta-cyclodextrin (allyl-beta-CD) as a cross-linker was employed for electrophoresis and electrochromatography. 2-Acrylamido-2-methylpropanesulfonic acid was added to the monomer solution to create a high electroendosmotic flow in electrochromatographic runs. These gels have excellent electrochromatographic and electrophoretic properties for low-molecular-weight compounds and DNA, as shown previously, namely high resolution combined with high stability. The unique cross-linker can be used for specific interaction with the alkyl and phenyl groups. The tripeptide glutathione (gamma-L-glutamyl-L-cysteinyl-glycine) and its benzyl conjugates were selected as model compounds to study the resolving power of the gel because they are difficult to separate by free zone electrophoresis. The limit of detection (LOD) for S-benzyl-glutathione was determined (ca. 7 microM). Run-by-run reproducibility was high (the separation factor of glutathione in the gel was 0.3 with 2.5% coefficient of variation, CV). Neutral compounds (acetone, acetophenone, propiophenone and butyrophenone) were separated electrochromatographically in the gel. The influence of organic solvent (acetonitrile) on the electroendosmotic mobility was similar to that in reversed-phase separations, although the separation mechanism is different. ATP, ADP and AMP were separated in less than 10 s by free-zone electrophoresis.

Chromatography, Micellar Electrokinetic Capillary↗

Tripeptide interference with human immunodeficiency virus type 1 morphogenesis.

Capsid assembly during virus replication is a potential target for antiviral therapy. The Gag polyprotein is the main structural component of retroviral particles, and in human immunodeficiency virus type 1 (HIV-1), it contains the sequences for the matrix, capsid, nucleocapsid, and several small polypeptides. Here, we report that at a concentration of 100 micro M, 7 of 83 tripeptide amides from the carboxyl-terminal sequence of the HIV-1 capsid protein p24 suppressed HIV-1 replication (>80%). The three most potent tripeptides, glycyl-prolyl-glycine-amide (GPG-NH(2)), alanyl-leucyl-glycine-amide (ALG-NH(2)), and arginyl-glutaminyl-glycine-amide (RQG-NH(2)), were found to interact with p24. With electron microscopy, disarranged core structures of HIV-1 progeny were extensively observed when the cells were treated with GPG-NH(2) and ALG-NH(2). Furthermore, nodular structures of approximately the same size as the broad end of HIV-1 conical capsids were observed at the plasma membranes of treated cells only, possibly indicating an arrest of the budding process. Corresponding tripeptides with nonamidated carboxyl termini were not biologically active and did not interact with p24.

Capsid Proteins↗