PubMed Health⌕ Search

Biomedical subjects

Stephan Miller

Publications and source records attributed to Stephan Miller.

At least 19 recordsLinked to original sources

Reproducibility of free-breathing cardiovascular magnetic resonance coronary angiography.

OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.

Adult↗

Three-dimensional morphological magnetic resonance imaging in infants and children with congenital heart disease.

BACKGROUND: Cardiac MRI has become a clinically useful supplement to ECHO and conventional X-ray angiography in the diagnostic work-up of patients with congenital heart disease (CHD). Three-dimensional (3D) sequences are capable of depicting both intracardiac and extracardiac structures with high accuracy in adults and adolescents. However, diagnostic image quality in infants and young children has not yet been reported. OBJECTIVE: To apply an optimized 3D steady-state free-precession (SSFP) MR sequence in infants and children with CHD. MATERIALS AND METHODS: In 20 patients (median age 1.8 years; ten male) with CHD, whole-chest imaging was performed with navigator-gated, isotropic 3D SSFP MRI at 1.5 T. Sequence parameters were adapted to special requirements in infancy. Measurements of intra- and extracardiac structures were performed by two independent observers and compared to spin-echo and cine gradient-recalled-echo sequences. RESULTS: Diagnostic image quality was achieved with the 3D SSFP technique in all patients, allowing the establishment of a diagnosis in all cases. Interobserver comparison of measurements from reformatted 3D SSFP datasets revealed only minor differences with standard deviations ranging from 0.3-1.3 mm for intracardiac and 0.3-0.7 mm for extracardiac anatomy (P = ns). CONCLUSION: Isotropic 3D SSFP MRI allows reliable and accurate assessment of CHD, even in free-breathing infants and young children.

Child↗

Affinity enhancement of an in vivo matured therapeutic antibody using structure-based computational design.

Improving the affinity of a high-affinity protein-protein interaction is a challenging problem that has practical applications in the development of therapeutic biomolecules. We used a combination of structure-based computational methods to optimize the binding affinity of an antibody fragment to the I-domain of the integrin VLA1. Despite the already high affinity of the antibody (Kd approximately 7 nM) and the moderate resolution (2.8 A) of the starting crystal structure, the affinity was increased by an order of magnitude primarily through a decrease in the dissociation rate. We determined the crystal structure of a high-affinity quadruple mutant complex at 2.2 A. The structure shows that the design makes the predicted contacts. Structural evidence and mutagenesis experiments that probe a hydrogen bond network illustrate the importance of satisfying hydrogen bonding requirements while seeking higher-affinity mutations. The large and diverse set of interface mutations allowed refinement of the mutant binding affinity prediction protocol and improvement of the single-mutant success rate. Our results indicate that structure-based computational design can be successfully applied to further improve the binding of high-affinity antibodies.

Amino Acid Substitution↗

Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: initial experience.

The purpose of this study was to prospectively evaluate an arterial spin-labeling technique, flow-sensitive alternating inversion-recovery (FAIR) true fast imaging with steady-state precession (FISP), for noninvasive quantification of renal perfusion in patients without a history of renal artery stenosis (RAS) and in patients with proved RAS. The study was approved by the local ethics committee, and all participants provided written informed consent. Six patients with hypertension but no history of renal artery disease and 12 patients with RAS underwent FAIR true FISP magnetic resonance (MR) imaging in a whole-body 1.5-T unit. RAS grade and scintigraphic perfusion data served as the reference standards. On the FAIR true FISP perfusion images, severe RAS (>70% luminal narrowing) could be clearly distinguished from no or mild RAS and moderate RAS (< or =70% luminal narrowing) (P < .005). Significant correlations between FAIR perfusion data and stenosis grade (r = -0.76) and between FAIR and single photon emission computed tomographic perfusion values (r = 0.83) were observed. FAIR true FISP was found to be suitable for quantitative perfusion imaging of the kidneys in patients with RAS.

Aged↗

High-resolution magnetic resonance angiography of the renal arteries using parallel imaging acquisition techniques at 3.0 T: initial experience.

OBJECTIVE: The purpose of this prospective study was to investigate the feasibility of high-resolution magnetic resonance angiography (MRA) of the kidneys at 3.0 T using parallel data acquisition. MATERIAL AND METHODS: Contrast-enhanced MRA of the renal arteries (RA) was performed in 12 volunteers and 12 consecutive patients (mean age 47.1 +/- 16.3 years) on a 3.0 T MR scanner. For CEMRA, a high-resolution 3-dimensional GRE FLASH sequence was implemented. Images were assessed subjectively on a 0 to 5 scoring scale by 2 reviewers. Quantitative evaluation was done by measuring the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). RESULTS: Diagnostic image quality was acquired in all individuals. In total, 62 RA were found, consisting of 48 main and 14 accessory RA. Overall visibility score for main RA was 4.82 +/- 0.38. RA were identified up to the third-order branches in 88%. In 3 of 12 patients, a hemodynamic relevant stenosis was found and proven by conventional angiogram. CONCLUSION: CEMRA at 3.0 T is advantageous in terms of better SNR and T1 weighting; therefore, measurement time can be reduced and spatial resolution can be increased without corruption of signal yield. Consequently, high-field MRA may be preferred for the evaluation of renal vascular anatomy in potential kidney donors or for the detection of renal artery stenosis.

Adult↗

Isotropic high spatial resolution magnetic resonance angiography of the supra-aortic arteries using two-dimensional parallel imaging (iPAT2) at 3 Tesla: a feasibility study.

OBJECTIVES: We sought to assess the feasibility of isotropic 3-dimensional contrast-enhanced magnetic resonance angiography (MRA) covering the supra-aortic and intracranial arteries with a MR sequence using parallel-imaging in phase- and slice-encoding directions. MATERIALS AND METHODS: Six volunteers and 5 patients with suspected cerebrovascular disease were examined at 3.0 T using a 16-element head-neck array. Contrast-enhanced 3-dimensional MRA (repetition time 3.2 milliseconds, echo time 1.2 milliseconds, flip angle 30 degrees , bandwidth 390 Hz/pixel) was acquired with integrated generalized autocalibrating partially parallel acquisition (GRAPPA), in both phase- and slice-encoding direction. Images were evaluated independently by 2 radiologists. Signal-to-noise ratio was calculated from phantom measurements. RESULTS: Signal-to-ratio levels of 8.7 +/- 2.2/48.7 +/- 10.2 with and without parallel-imaging (GRAPPA x 6) were measured, respectively. Scoring of image quality by observer 1/observer 2 on a 4-point-scale (range 0-3) yielded 2.5 +/- 1.0/2.4 +/- 1.0 and 2.1 +/- 1.0/2.0 +/- 1.1 for extracranial and intracranial vessel segments in volunteers and 2.8 +/- 0.6/2.7 +/- 0.7 and 2.0 +/- 1.2/2.1 +/- 1.1 in patients, respectively. The interobserver agreement was excellent (k = 0.82). CONCLUSIONS: This study shows that contrast-enhanced MRA, applying parallel-imaging in both phase- and slice-encoding direction (iPAT), is feasible at 3.0 T. Coverage of the carotid and vertebro-basilar circulation was achieved.

Adolescent↗

Cardiac cine imaging at 3 Tesla: initial experience with a 32-element body-array coil.

PURPOSE: We sought to assess the feasibility of cardiac cine imaging and evaluate image quality at 3 T using a body-array coil with 32 coil elements. MATERIALS AND METHODS: Eight healthy volunteers (3 men; median age 29 years) were examined on a 3-T magnetic resonance scanner (Magnetom Trio, Siemens Medical Solutions) using a 32-element phased-array coil (prototype from In vivo Corp.). Gradient-recalled-echo (GRE) cine (GRAPPAx3), GRE cine with tagging lines, steady-state-free-precession (SSFP) cine (GRAPPAx3 and x4), and SSFP cine(TSENSEx4 andx6) images were acquired in short-axis and 4-chamber view. Reference images with identical scan parameters were acquired using the total-imaging-matrix (Tim) coil system with a total of 12 coil elements. Images were assessed by 2 observers in a consensus reading with regard to image quality, noise and presence of artifacts. Furthermore, signal-to-noise values were determined in phantom measurements. RESULTS: In phantom measurements signal-to-noise values were increased by 115-155% for the various cine sequences using the 32-element coil. Scoring of image quality yielded statistically significant increased image quality with the SSFP-GRAPPAx4, SSFP-TSENSEx4, and SSFP-TSENSEx6 sequence using the 32-element coil (P < 0.05). Similarly, scoring of image noise yielded a statistically significant lower noise rating with the SSFP-GRAPPAx4, GRE-GRAPPAx3, SSFP-TSENSEx4, and SSFP-TSENSEx6 sequence using the 32-element coil (P < 0.05). CONCLUSION: This study shows that cardiac cine imaging at 3 T using a 32-element body-array coil is feasible in healthy volunteers. Using a large number of coil elements with a favorable sensitivity profile supports faster image acquisition, with high diagnostic image quality even for high parallel imaging factors.

Adult↗

Renal magnetic resonance angiography at 3.0 Tesla using a 32-element phased-array coil system and parallel imaging in 2 directions.

PURPOSE: The aim of the present study was to assess the feasibility of renal magnetic resonance angiography at 3.0 T using a phased-array coil system with 32-coil elements. Specifically, high parallel imaging factors were used for an increased spatial resolution and anatomic coverage of the whole abdomen. MATERIALS AND METHODS: Signal-to-noise values and the g-factor distribution of the 32 element coil were examined in phantom studies for the magnetic resonance angiography (MRA) sequence. Eleven volunteers (6 men, median age of 30.0 years) were examined on a 3.0-T MR scanner (Magnetom Trio, Siemens Medical Solutions, Malvern, PA) using a 32-element phased-array coil (prototype from In vivo Corp.). Contrast-enhanced 3D-MRA (TR 2.95 milliseconds, TE 1.12 milliseconds, flip angle 25-30 degrees , bandwidth 650 Hz/pixel) was acquired with integrated generalized autocalibrating partially parallel acquisition (GRAPPA), in both phase- and slice-encoding direction. Images were assessed by 2 independent observers with regard to image quality, noise and presence of artifacts. RESULTS: Signal-to-noise levels of 22.2 +/- 22.0 and 57.9 +/- 49.0 were measured with (GRAPPAx6) and without parallel-imaging, respectively. The mean g-factor of the 32-element coil for GRAPPA with an acceleration of 3 and 2 in the phase-encoding and slice-encoding direction, respectively, was 1.61. High image quality was found in 9 of 11 volunteers (2.6 +/- 0.8) with good overall interobserver agreement (k = 0.87). Relatively low image quality with higher noise levels were encountered in 2 volunteers. CONCLUSION: MRA at 3.0 T using a 32-element phased-array coil is feasible in healthy volunteers. High diagnostic image quality and extended anatomic coverage could be achieved with application of high parallel imaging factors.

Adult↗

Assessment of myocardial viability using delayed enhancement magnetic resonance imaging at 3.0 Tesla.

OBJECTIVE: Cardiac magnetic resonance imaging (MRI) at 3.0 T has recently become available and potentially provides a significant improvement of tissue contrast in T1-weighted imaging techniques relying on Gd-based contrast enhancement. Imaging at high-field strength may be especially advantageous for methods relying on strong T1-weighting and imaging after contrast material administration. The aim of this study was to compare cardiac delayed enhancement (DE) MRI at 3.0 T and 1.5 T with respect to image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) between infarcted and normal myocardium. MATERIALS AND METHODS: Forty consecutive patients with history of myocardial infarction were examined at 3.0 T (n = 20) or at 1.5 T (n = 20). Myocardial function was assessed using cine steady-state-free-precession (SSFP) sequences (TR 3.1 milliseconds, TE 1.6 milliseconds, flip angle 70 degrees , and a matrix of 168 x 256 at 1.5 T and TR 3.4 milliseconds, TE 1.7 milliseconds, flip angle 50 degrees and a matrix of 168 x 256 at 3.0 T), acquired in long- and short-axes views. DE images were obtained 15 minutes after the administration of 0.15 mmol of Gd-DTPA/kg body weight using a segmented inversion recovery prepared gradient echo sequence at 1.5 T (TR 9.6 milliseconds, TE 4.4 milliseconds, flip angle 25 degrees , matrix 160 x 256, bandwidth 140 Hertz/pixel) and at 3.0 T (TR 9.8 milliseconds, TE 4.3 milliseconds, flip angle 30 degrees , matrix 150 x 256, bandwidth 140 Hertz/pixel). For image analysis, standardized SNR and CNR measurements were performed in infarcted and remote myocardial regions. Two independent observers rated image quality on a 4-point scale (0 = poor image quality, 1 = sufficient image quality, 2 = good image quality, 3 = excellent image quality). RESULTS: High diagnostic image quality was obtained in all patients. Rating of mean image quality was 2.2 +/- 0.8 at 1.5 T and 2.5 +/- 0.6 at 3.0 T (P = 0.012) for observer 1 and 2.2 +/- 0.7 at 1.5 T and 2.6 +/- 0.6 at 3.0 T (P = 0.003) for observer 2, respectively. Interobserver agreement was good (kappa = 0.68 at 1.5 T and 0.78 at 3.0 T). SNR measurements yielded a mean SNR of 37.8 +/- 13.9/22.9 +/- 6.0 in infarcted myocardium (P < 0.001) and 5.6 +/- 2.2/5.9 +/- 2.4 in normal myocardium (P = 0.45) at 3.0 T/1.5 T, respectively. CNR measurements revealed mean values of 32.4 +/- 13.0/16.7 +/- 5.4 (P< 0.001) at 3.0 T/1.5 T, respectively. CONCLUSIONS: Delayed enhancement MRI at 3.0 T is feasible and provides superior image quality compared with 1.5 T. Furthermore, using identical contrast doses, increased SNR and CNR values were recorded at 3.0 T.

Adult↗

Atherosclerotic disease: whole-body cardiovascular imaging with MR system with 32 receiver channels and total-body surface coil technology--initial clinical results.

In this prospective study, the feasibility of a comprehensive cardiovascular imaging protocol with a dedicated whole-body 1.5-T magnetic resonance (MR) imager with 32 receiver channels in 34 patients with peripheral arterial occlusive disease was evaluated. Informed consent and institutional review board approval were obtained. Three-dimensional MR angiographic data sets were acquired with adapted injection protocol. Cardiac functional imaging and delayed-enhancement imaging were performed, as were fluid-attenuated inversion-recovery imaging of the brain and time-of-flight MR angiography of the intracranial blood vessels. Sensitivity and specificity for depiction of significant vascular stenosis (> 70%) were 96%, with conventional digital subtraction angiography as the standard. Substantial microangiopathic tissue alterations (n = 4) and/or cerebral infarction (n = 4) were diagnosed in seven patients. In seven patients, subendocardial or transmural delayed enhancement was detected in corresponding regions, indicating prior myocardial infarction. Previously unknown findings diagnosed with MR imaging required midterm follow-up or therapy in 24 patients, whereas change of therapy or immediate treatment was necessary in three. For patients suspected of having systemic atherosclerotic disease, comprehensive risk assessment is feasible within 30 minutes.

Adult↗

Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography.

OBJECTIVE: To assess functional parameters using multidetector-row computed tomography (MDCT) and echocardiography and to compare the results with magnetic resonance imaging (MRI). MATERIALS AND METHODS: End-diastolic-volume (EDV), end-systolic-volume (ESV), stroke-volume (SV), ejection-fraction (EF), and myocardial mass (MM) were calculated based on CT data sets from 52 patients. Echocardiography was performed in 24 of the 52 patients. The results from MDCT and echocardiography were compared with MRI. RESULTS: A strong correlation between MDCT and MRI (r=0.66-0.90) was found for all parameters. Echocardiography revealed a low or moderate correlation (0.05-0.59). Compared to MRI the average differences with MDCT were for EDV 15.1 ml, ESV 10.6 ml, SV 4.5 ml, EF 1.8%, and MM 8.2 g, for EDV determined by echocardiography 36.2 ml, ESV 6.8 ml, and EF 13.9%. Bland-Altman analysis revealed acceptable limits of agreement between MRI and MDCT. CONCLUSIONS: MDCT enables reliable quantification of left ventricular function. Echocardiography was found to have only a moderate agreement of functional parameters with MRI.

Coronary Angiography↗

Myocardial perfusion after angioplasty in patients suspected of having single-vessel coronary artery disease: improvement detected at rest-stress first-pass perfusion MR imaging--initial experience.

PURPOSE: To prospectively assess myocardial perfusion before and after successful intervention in patients suspected of having single-vessel coronary artery disease by using a steady-state free precession (SSFP) perfusion magnetic resonance (MR) imaging sequence. MATERIALS AND METHODS: Local ethics committee approval and informed consent were obtained. Rest-stress perfusion MR imaging studies were performed in 18 patients with coronary artery disease (12 men, six women; mean age, 58.6 years +/- 13.6 [standard deviation]; range, 30-79 years) at 1.5 T with a multisection saturation-recovery SSFP sequence and 0.025 mmol gadopentetate dimeglumine per kilogram of body weight. MR studies were performed before (n = 18), several days after (n = 18), and 8 months after (n = 10) coronary intervention. Nine patients underwent percutaneous transluminal coronary angioplasty (PTCA) alone, and nine patients underwent PTCA with stent placement. Myocardial perfusion reserve index (MPRI) was calculated by dividing results of myocardial perfusion at maximal vasodilation by results at rest. The standard for myocardial perfusion was technetium 99m tetrofosmin single photon emission computed tomography. Statistical significance was tested with univariate variance analysis and Student t tests. RESULTS: In the area of the stenosed vessel, MPRI was 1.04 +/- 0.24 before treatment and 2.18 +/- 0.57 several days afterward (P < .001). In remote areas, MPRI was 2.42 +/- 0.44. In the stent group, MPRI increased by 156%, from 0.99 +/- 0.20 before stent placement to 2.53 +/- 0.53 after (P < .001). Similarly, in the PTCA only group, MPRI increased by 72%, from 1.08 +/- 0.27 before PTCA to 1.87 +/- 0.39 after (P < .001). At follow-up in patients without recurring chest pain, MPRI was 2.14 +/- 0.37 in the area of the treated artery and 2.29 +/- 0.47 in remote areas (P = .06). CONCLUSION: The MPRI, derived from rest-stress examinations, can provide information on success of interventional procedures in stenosed coronary arteries.

Adult↗

Glial cell line-derived neurotrophic factor (GDNF) receptor alpha-1 (GFR alpha 1) is highly selective for GDNF versus artemin.

To clarify whether glial cell line-derived neurotrophic factor (GDNF) receptor alpha-1 (GFRalpha1), the glycosylphosphatidylinositol (GPI)-linked coreceptor for GDNF, is also a functional coreceptor for artemin (ART), we have studied receptor binding, signaling, and neuronal survival. In cell-free binding studies, GFRalpha1-Ig displayed strong preferential binding to GDNF, though in the presence of soluble RET, weak binding to ART could also be detected. However, using GFRalpha1-transfected NB41A3 cells, ART showed no detectable competition against the binding of (125)I-labeled GDNF. Moreover, ART failed to induce phosphorylation of extracellular signal-related kinase (ERK) and Akt in these cells and was >10(4)-fold less potent than GDNF in stimulating RET phosphorylation. When rat primary dorsal root ganglion (DRG) neurons were used, only the survival promoting activity of GDNF and not that of ART was blocked by an anti-GFRalpha1 antibody. These results indicate that although ART can interact weakly with soluble GFRalpha1 constructs under certain circumstances in vitro, in cell-based functional assays GFRalpha1 is at least 10 000-fold selective for GDNF over ART. The extremely high selectivity of GFRalpha1 for GDNF over ART and the low reactivity of ART for this receptor suggest that GFRalpha1 is not likely to be a functional coreceptor for ART in vivo.

Animals↗

Diagnosis of vascular rings and slings using an interleaved 3D double-slab FISP MR angiography technique.

BACKGROUND: Congenital upper airway obstruction and dysphagia may be caused by vascular rings and slings. Often, invasive and radiation-dependent diagnostic procedures are needed to clarify the diagnosis. OBJECTIVE: To evaluate the diagnostic utility of high-resolution, free-breathing three-dimensional double-slab fast imaging with steady precession magnetic resonance angiography (3D FISP MRA) in infants and children with respiratory upper airway obstruction and/or dysphagia for detection or exclusion of vascular rings and slings. MATERIALS AND METHODS: Eleven patients (median age 1.3 years; range 5.1 months to 15.8 years) were investigated prospectively with 3D FISP MRA and spin-echo techniques. Additional diagnostic data were available from surgery (n=7), cardiac catheterization (n=5), CT (n=2), barium swallow (n=3) and bronchoscopy/oesophagoscopy (n=4). RESULTS: In one case, diagnosis was missed with low-resolution spin-echo sequences, but high-resolution 3D FISP MRA revealed a double aortic arch. 3D FISP MRA accurately found (n=8) or excluded (n=3) vascular rings or slings in all patients. Using a five-level grading system for 3D FISP MRA image quality (1=non-diagnostic; 5=excellent), the mean grade was 4.3+/-0.7 with no significant grade difference between two independent observers (P=0.81). CONCLUSIONS: High-resolution 3D FISP MRA accurately defined or excluded vascular rings and slings in patients with respiratory symptoms and/or dysphagia. This technique may provide a non-invasive, radiation-free alternative without contrast agents for diagnosis of vascular rings and slings in free-breathing infants and children.

Adolescent↗

Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: first clinical experience.

PURPOSE: To demonstrate the feasibility of detecting atherosclerotic vascular disease using an innovative magnetic resonance angiography (MRA) protocol in combination with a dedicated whole-body MR scanner with new surface coil technology. MATERIALS AND METHODS: A total of 10 volunteers and eight patients with peripheral arterial occlusive disease (PAOD) were examined at 1.5 T. Conventional digital subtraction angiography (DSA) of the symptomatic region was available as a reference standard in all eight patients. Depending on subjects' size, four to five three-dimensional data sets were acquired using an adapted injection protocol. Images were assessed independently by two readers for vascular pathology. Additionally, signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were measured. RESULTS: Whole-body MRA yielded excellent sensitivity and specificity of more than 95% for both readers with high interobserver agreement (k = 0.93). Surface coil signal reception rendered a high SNR (mean 151.28 +/- 54.04) and CNR (mean 120.75 +/- 46.47). Despite lower SNR and CNR of the cranial and cervical vessels, a two-step injection protocol exhibited less venous superposition and therefore proved to be superior compared to single-bolus injection. CONCLUSION: Our approach provides accurate noninvasive high-resolution imaging of systemic atherosclerotic disease, covering the arterial vasculature from intracranial arteries to distal runoff vessels. The recently introduced MR scanner and coil technology is feasible to significantly increase the performance of whole-body MRA.

Adult↗

Assessment of minimally invasive direct coronary artery bypass grafting of the left internal thoracic artery by means of magnetic resonance imaging.

OBJECTIVES: We sought to evaluate graft patency, flow, and flow reserve in patients with minimally invasive direct coronary artery bypass surgery of internal thoracic artery grafts by a combined magnetic resonance protocol with a phase-contrast technique and magnetic resonance angiography. METHODS: At 1.5 T (Magnetom Sonata, Siemens), 30 symptomatic patients with 30 left internal thoracic artery grafts were examined 6 years after minimally invasive surgical intervention. Navigator-gated magnetic resonance angiography and contrast-enhanced FLASH-3D magnetic resonance angiography (0.2 mmol gadopentate-diethylene triamine pentetic acid [Gd-DTPA]/kg body weight) was used to assess bypass patency. Phase-contrast flow measurements with retrospective gating were performed in the internal thoracic artery grafts at rest and after stress induction with dipyridamole (0.57 mg/kg body weight). Graft patency was evaluated by means of multidetector computed tomography (Sensation 16, Siemens). RESULTS: Internal thoracic artery grafts were occluded in 5 of 30 patients. In 6 patients the anastomosis to the left anterior descending artery was highly stenotic (>70 % ) at multidetector computed tomography. In patients with regular grafts (multidetector computed tomography), a significant improvement of graft flow ( P < .001) and diastolic/systolic peak velocity ratio ( P < .001) after stress induction was detected. Magnetic resonance angiography combined with flow reserve measurements could differentiate between occluded-stenotic and regular minimally invasive direct coronary artery bypass grafts. CONCLUSIONS: Magnetic resonance imaging allows a combined assessment of bypass patency and flow with flow reserve in patients after the minimally invasive direct coronary artery bypass operation. The protocol of this study might be applicable for the evaluation of graft status in symptomatic patients after revascularization.

Aged↗

Magnetic resonance elastography of the breast: correlation of signal intensity data with viscoelastic properties.

OBJECTIVES: We sought to investigate the potential value of magnetic resonance (MR) elastography to improve the differentiation between benign and malignant tumors. MATERIAL AND METHODS: Measurements of 5 patients with 6 malignant lesions, 11 patients with benign lesions, and 4 patients with no lesions at all were performed at 1.5 Tesla. After breast MR imaging, MR elastography was performed as a targeted measurement. Low-frequency mechanical waves (65 Hz) were transmitted into the breast tissue using an oscillator and were displayed by means of a MR sequence within the phase of the MR image. After reconstruction, the viscoelastic information was correlated with the signal intensity and morphology data. RESULTS: All examinations were technically successful realized in approximately 25 minutes. Malignant tumors documented higher values of elasticity than benign corresponding with signal intensity and morphologic data. CONCLUSION: A good separation exists between benign and malignant lesions in elasticity, corresponding with specific signal intensity and morphologic data. Further clinical studies with a larger number of patients are needed for extended validation.

Adolescent↗