PubMed Health⌕ Search

Biomedical subjects

Stephan Mohr

Publications and source records attributed to Stephan Mohr.

8 recordsLinked to original sources

A micro-reactor for preparing uniform molecularly imprinted polymer beads.

In this study, uniform spherical molecularly imprinted polymer beads were prepared via controlled suspension polymerization in a spiral-shaped microchannel using mineral oil and perfluorocarbon liquid as continuous phases. Monodisperse droplets containing the monomers, template, initiator, and porogenic solvent were introduced into the microchannel, and particles of uniform size were produced by subsequent UV polymerization, quickly and without wasting polymer materials. The droplet/particle size was varied by changing the flow conditions in the microfluidic device. The diameter of the resulting products typically had a coefficient of variation (CV) below 2%. The specific binding sites that were created during the imprinting process were analysed via radioligand binding analysis. The molecularly imprinted microspheres produced in the liquid perfluorocarbon continuous phase had a higher binding capacity compared with the particles produced in the mineral oil continuous phase, though it should be noted that the aim of this study was not to optimize or maximize imprinting performance, but rather to demonstrate broad applicability and compatibility with known MIP production methods. The successful imprinting against a model compound using two very different continuous phases (one requiring a surfactant to stabilize the droplets the other not) demonstrates the generality of this current simple approach.

Equipment Design↗

Rapid chloride analysis using miniaturised isotachophoresis.

A new design of miniaturised separation device for performing isotachophoresis (ITP) has been produced. The device contains a simple arrangement of channels comprising a single separation channel with a 'double T' injection geometry. The device was produced in poly(methyl methacrylate) and incorporates an on-column conductivity detector. A new electrolyte system was developed to enable the rapid determination of chloride to be made. This electrolyte system uses a leading ion of 3.5 mM nitrate at pH 3.0 with 0.5 mM indium(III) added as a complexing agent. Use of this electrolyte system with the new separation device allowed chloride samples to be analysed in under 100 s, with a limit of detection (LOD) calculated to be 2.2 mg l(-1).

Chlorides↗

An integrated optical leaky waveguide sensor with electrically induced concentration system for the detection of bacteria.

An integrated, sensitive and rapid system was developed for the detection of bacteria. The system combined an optical metal-clad leaky waveguide (MCLW) sensor with an electric field. The electric field was used to concentrate Bacillus subtilis var. niger(BG) bacteria spores onto the immobilized anti-BG antibody on the MCLW sensor surface. This sensor combination has been characterised by detecting the scattering from bacterial spores, which are concentrated at the sensor surface, when they are illuminated at the coupling angle; and by detection of fluorescence from labelled antibodies added after the spores had been captured on the surface. The light scattering and fluorescence detection methods gave a detection limit of BG bacterial spores of 1 x 10(3) spores ml(-1) when the electric field was applied for 3 minutes.

Bacillus subtilis↗

An integrated disposable dye clad leaky waveguide sensor for micro-TAS applications.

An integrated, disposable, dye clad leaky waveguide (DCLW) device has been fabricated and tested for both refractive index and fluorescence detection in mu-TAS applications. The chip comprises the required flow geometry and optical coupling elements in a robust device that is relatively simple and inexpensive to fabricate. Disposable DCLW chips were fabricated at room temperature by spin-coating both the dye and silica sol-gel waveguiding layers on a polymer substrate which contained injection moulded grating coupler. These devices have been designed to increase the interaction of the evanescent field light at the channel wall and with the sample in the channel. The DCLW device has been used to detect changes in the refractive index of different percentages of glycerol solutions and to detect low concentrations down to 10(-12) M fluorescein using a grating coupler.

Journal Article↗

An integrated metal clad leaky waveguide sensor for detection of bacteria.

An integrated optical metal clad leaky waveguide (MCLW) sensor device has been developed for the detection of bacteria. This is more sensitive than waveguide sensors currently in use. The MCLW device has been fabricated to extend the evanescent field to provide significant light intensity over the entire volume of the bacteria bound on the chip surface within this field. This in turn increases the interaction of the light with the entire volume of the bacteria. MCLW devices have been used for detecting refractive index changes, scattering, and fluorescence from bacterial spores captured on an immobilized antibody. The detection limit of Bacillus subtilis var. niger bacterial spores using refractive index detection was 8 x10(4) spores/mL. The scattering intensity of the BG spores was found to be three times greater than the scattering intensity generated using surface plasmon resonance. The extended light propagation along the direction of flow for a few millimeters provides an effective interrogation approach to increase the area of detection to detect low concentrations down to 1 x 10(4) spores/mL. The sensor was then optimized by studying the key factors affecting sensor performance including changing the pH of the medium, type of antibody immobilization matrix, sensor surface regeneration approaches, and longevity of the sensor.

Bacteria↗

Fluorine-18-labeled fluorodeoxyglucose-positron emission tomography studies of acute brainstem Lyme neuroborreliosis [corrected] Case report.

The authors report on a patient suffering from acute Lyme borreliosis who underwent two consecutive [18F]fluorodeoxyglucose-positron emission tomography (FDG-PET) studies demonstrating the course of the disease. The first FDG-PET study revealed markedly increased glucose metabolism in the brainstem, matching exactly the signal abnormalities exhibited on magnetic resonance images and indicating a brainstem tumor. A second PET scan demonstrated no abnormality in this region, thus reflecting clinical remission following antibiotic therapy. Data in the present case indicate that hypermetabolic findings on FDG-PET studies in the brainstem region should be regarded with caution and that neuroborreliosis must be considered as a possible differential diagnosis.

Acute Disease↗

Bacteria detection using disposable optical leaky waveguide sensors.

Novel disposable absorbing material clad leaky waveguide sensor devices (LWD) have been developed for the detection of pathogenic particles such as bacteria. These chips are tailored to give the maximum extension of the evanescent field at the sensor surface in order to place the entire volume of the bacteria captured by immobilized antibodies on the chip surface within this field. This in turn increases the interaction of the light with the bacteria's bulk volume. Disposable LWD chips were fabricated at room temperature and without the use of expensive fabrication equipment. These LWDs have been characterised by detecting refractive index (RI) changes, scattering and fluorescence from bacterial spores at the sensor surface when illuminated at the coupling angle. The detection limit of Bacillus subtilis var. niger (BG) bacterial spores was 10(4) spores/ml and the illumination intensity of the spores was found to be three times greater than the illumination intensity generated using the surface plasmon resonance (SPR).

Bacillus↗

Rapid prototyping for injection moulded integrated microfluidic devices and diffractive element arrays.

This paper describes two fabrication procedures that makes it possible to design, fabricate and injection mold a microfluidic system with an on board coupling element or an optical array platform in less than four hours. Epoxy masters for the array and a single diffractive element were produced using conventional soft lithography techniques and a commercially available UV curable epoxy. The fabrication of the master for the integrated microfluidic device utilized the surface chemistry of polyester and its interaction with the anionic surfactant sodium dodecyl sulfate (SDS), to selectively inhibit the adhesion between the epoxy and the polyester film during the curing reaction. The transfer of a microfluidic design and the required coupling element (632 nm holographic grating) along the base of the channel was completed in a single step. The turnaround time from design to injection molded device whether a microchannel or array was 3.5 h.

Journal Article↗