PubMed Health⌕ Search

Biomedical subjects

Stephan Schiller

Publications and source records attributed to Stephan Schiller.

3 recordsLinked to original sources

Parts per trillion sensitivity for ethane in air with an optical parametric oscillator cavity leak-out spectrometer.

Spectroscopic detection of ethane in the 3-microm wavelength region was performed by means of a cw optical parametric oscillator and cavity leak-out. We achieved a minimum detectable absorption coefficient of 1.6 x 10(-10) cm 1/square root of Hz, corresponding to an ethane detection limit of 6 parts per trillion/square root of Hz. For 3-min integration time the detection limit was 0.5 parts per trillion. The levels are to our knowledge the best demonstrated so far. These frequency-tuning capabilities facilitated multigas analysis with simultaneous monitoring of ethane, methane, and water vapor in human breath.

Journal Article↗

Modern Michelson-Morley experiment using cryogenic optical resonators.

We report on a new test of Lorentz invariance performed by comparing the resonance frequencies of two orthogonal cryogenic optical resonators subject to Earth's rotation over approximately 1 yr. For a possible anisotropy of the speed of light c, we obtain Delta(theta)c/c(0)=(2.6+/-1.7)x10(-15). Within the Robertson-Mansouri-Sexl (RMS) test theory, this implies an isotropy violation parameter beta-delta-1 / 2=(-2.2+/-1.5)x10(-9), about 3 times lower than the best previous result. Within the general extension of the standard model of particle physics, we extract limits on seven parameters at accuracies down to 10(-15), improving the best previous result by about 2 orders of magnitude.

Journal Article↗

All-solid-state tunable continuous-wave ultraviolet source with high spectral purity and frequency stability.

We present a novel approach for the generation of higly frequency-stable, widely tunable, single-frequency cw UV light that is suitable for high-resolution spectroscopy. Sum-frequency generation (SFG) of two solid-state sources with a single cavity resonant for both fundamental waves is employed. Using a highly stable, narrow-linewidth frequency-doubled cw Nd:YAG laser as a master laser and slaving to it the SFG cavity and the other fundamental wave from a Ti:sapphire laser, we generate UV radiation of 33-mW output power around 313 nm. Alternatively, we use a diode laser instead of the Ti:sapphire laser and produce an output power of 2.1 mW at 313 nm. With both setups we obtain a continuous tunability of >15 GHz, short-term frequency fluctuations in the submegahertz range, a long-term frequency drift below 100 MHz/h, and stable operation for several hours. The theory of optimized doubly resonant SFG is also given.

Journal Article↗