Exposure of churchgoers to airborne particles.

Particle mass and number measurements in a church indicate significant increases of indoor particle concentrations during the burning of incense. Generally, varying concentration regimes can be attributed to different "modes of indoor activity" and emission sources. While periods of candle burning are negligible concerning particle concentrations, increases by a factor of 6.9 and 9.1 during incense burning were observed for PM10 and PM1, respectively. At maximum, indoor PM10 shows an 8.1-fold increase in comparison to outdoor measurements. The increase of particles < 2 microm is significantly enhanced in comparison to larger particles. Due to a particle decay rate of 0.9 h(-1) post-service concentrations are elevated for a time span of approximately 24 h above indoor background concentrations.

Air Pollutants↗

Apoptotic vesicles crossprime CD8 T cells and protect against tuberculosis.

CD8 T lymphocytes are important effectors in protective immunity against Mycobacterium tuberculosis. We recently characterized the detour pathway of CD8 T cell activation in tuberculosis mediated by apoptotic vesicles from infected cells that transport mycobacterial antigens to dendritic cells (DCs). Here we demonstrate that apoptotic vesicles from mycobacteria-infected macrophages stimulate CD8 T cells in vivo. Homing of DCs to draining lymph nodes was critically required for effective crosspriming. Subsequent fate of vesicle-associated antigens in recipient DCs was characterized by endosomal mechanisms predominating over proteasomal processing. In addition, vesicle processing depended on the presence of saposins to disintegrate apoptotic membranes. Apoptotic vesicles displayed potent adjuvant activity by stimulating through Toll-like receptors (TLR). Ultimately, vaccination with vesicles from infected cells induced protection against M. tuberculosis infection. Taken together, we propose the detour pathway to represent a genuine immunological mechanism mediating crosspriming of CD8 T cells in vivo and protection against tuberculosis.

Adjuvants, Immunologic↗

Scant activation of CD8 T cells by antigen loaded on heat shock protein.

Heat shock proteins (HSP) not only function as chaperones for denatured proteins but also for antigenic peptides, thus inducing protective T cell responses. Here we show that vaccination with peptide-loaded HSP70 causes initial interferon-gamma production by murine CD8 T cells but no T cell expansion. These CD8 T cells lacked cytotoxic activity in vitro and in vivo, which was not due to apoptosis. Restimulation with peptide-pulsed dendritic cells both bypassed the proliferative block and suspended the non-protective state of CD8 T lymphocytes in an infection model with the bacterial pathogen, Listeria monocytogenes. Cotransfer of antigen-specific CD4 T cells circumvented the proliferative arrest of CD8 T cells. Our data suggest that HSP vaccines induce CD8 T cell unresponsiveness unless proficient help is provided. Assuming that this model reflects the antigenically experienced human condition where immunological space is restricted and any T cell response possibly leads to suppression of heterologous reactions, our findings bear implications for rational vaccination protocols including those for immunocompromised patients.

Antigens↗

MagScrew total artificial heart in vivo performance above 200 beats per minute.

PURPOSE: Downsizing pulsatile devices requires an increase of beat rate if flow capacity is to be maintained. We applied this concept to the preclinical MagScrew total artificial heart (TAH). DESCRIPTION: The device fills passively with a stroke volume of 45 ml and beat rates up to 250 beats per minute (bpm). EVALUATION: Stable hemodynamics were observed during a 30-day bovine implant with a flow of 8.7 +/- 1.2 L/min at beat rates of 204 +/- 18 bpm. Device filling was exceptional up to 250 bpm generating flow of greater than 12 L/min. Beat rate adapted to preload in a way similar to a Frank-Starling response. Left and right atrial pressures were balanced. The aortic pulse pressure was 49-70 mm Hg, which translates to a pulsatility index of 0.49-0.77. Organ functions were preserved and blood damage did not occur. CONCLUSIONS: Increasing the beat rate while downsizing the MagScrew TAH was successful with strong flow generation by passive filling. Pulsatility was maintained at high beat rates. This innovative approach may be used to develop small pulsatile pumps.

Animals↗

In vivo studies of the MagScrew total artificial heart in calves.

The purpose of this study was to evaluate the in vivo pump performance of our total artificial heart (TAH), the "MagScrew TAH." The TAH consists of a blood pump and control logic developed at the Cleveland Clinic and the MagScrew actuator and electronic control system developed by Foster-Miller Technologies, Inc. (Albany, NY). MagScrew TAH implantation was performed in two calves. Study durations were 50 and 5 days. The causes of termination were prosthetic valve endocarditis in one case and cable failure in the other. Mean left pump flow ranged from 8.0 to 9.7 L/min, with left atrial pressure of 3.0 to 16.0 mm Hg. Preload sensitivity of the MagScrew TAH demonstrated a Frank-Starling response to preload in automatic mode. The relationship between right and left atrial pressure was well balanced. Mean arterial pressure and mean pulmonary artery pressure were maintained within physiologic ranges over study duration. There were no signs of bleeding, hemolysis, or organ failure. The MagScrew TAH showed physiologic pump performance, and hemodynamics were well maintained without any organ failure. Further development testing will bring the MagScrew TAH to the point of preclinical readiness testing.

Animals↗

In vitro controllability of the MagScrew total artificial heart system.

The purpose of this study was to evaluate the in vitro responses to preload and afterload of our total artificial heart (TAH), the MagScrew TAH. The TAH consists of two blood pumps and a control logic, developed at the Cleveland Clinic, OH, and the MagScrew actuator and its electronic control system, developed by Foster-Miller Technologies, Inc., Albany, NY. Tests were performed on a mock circulatory loop, using water as a test fluid. Preload sensitivity of the Mag-Screw TAH demonstrated a Frank-Starling response to preload in automatic mode. A peak flow of 10 L/min was obtained, with a left atrial pressure of 13 mm Hg. The relationship between right atrial pressure and left atrial pressure was well balanced when tested with a left bronchial shunt flow of 5% and a range of pulmonary artery and aortic pressures. With respect to afterload response, the left pump showed a relatively low sensitivity, which allowed the pump to maintain perfusion over a wide range of aortic pressures. The right pump, on the other hand, was much more sensitive to pulmonary artery pressure, which provided a measure of protection against pulmonary congestion. The very effective physiologic response of the MagScrew TAH is believed to result from employment of a left master, alternating ejection control logic, high inherent sensitivity of the blood pumps to atrial pressure, a lower effective stroke volume for the right pump, and a scaling of right side motor ejection voltage to 80% of that used for the left side ejection.

Aorta↗

In vivo performance and biocompatibility of the MagScrew ventricular assist device.

Currently available ventricular assist devices (VADs) have limitations in long-term durability and blood compatibility. We evaluated a prototype of a pulsatile MagScrew VAD for in vivo hemodynamic performance and biocompatibility. The device is composed of an actuator, blood pump housing, diaphragm, pusher plate, and bioprosthetic valves. Its protein-coated ("biolized") blood-contacting surface inhibits clot formation. Forces between moving parts of the actuator are transmitted magnetically, eliminating a primary source of friction and wear. The pump fills passively and is highly preload sensitive. The device was implanted into three calves for 90, 10, and 57 days, respectively. No anticoagulants were given postoperatively. The device functioned without technical problems during the entire course of each experiment, with mean device flow ranging between 5.4 and 9.0 L/min. Autopsy of the first two calves revealed no sign of embolization and clean blood-contacting surfaces of the devices. The third experiment was complicated by a prosthetic valve endocarditis with infectious embolization, and a few small depositions were found in the pump. In conclusion, the MagScrew VAD has demonstrated a high level of performance and biocompatibility in three calves studied for 10-90 days. Vigorous development is in progress to bring this device to preclinical readiness and thus provide surgeons with the VAD of choice for permanent implantation.

Animals↗

Performance and reliability of the CPB/ECMO Initiative Forward Lines Casualty Management System.

The Cleveland Clinic Foundation CPB/ECMO Initiative Forward Casualty Management System is an economical, compact, transportable, disposable system designed to permit a rapid expansion of trauma management services requiring cardiopulmonary bypass (CPB) or extracorporeal membrane oxygenation (ECMO) pulmonary support. The system, composed of a rotary blood pump, a pump motor driver, and an electronic control console as the blood pumping subsystem, also includes commonly used compatible commercial oxygenators, venous reservoirs, and cannulae. In vitro durability testing accumulated over 100 hours without failure. In vivo reliability was tested in 10 calves under general anesthesia during 6 hours of CPB and ECMO under full heparinization at nominal operating conditions of 4-5 l/min and 2-4 l/min blood flow respectively, and mean arterial pressures between 65 and 100 mm Hg. A mean time to failure of 57 hours was reached during the animal series. Results of these test series demonstrated that this system has the capability to reliably operate during a 6-hour conventional CPB or ECMO procedure, while providing flexibility and ease of use for the operator.

Animals↗

MagScrew TAH: an update.

The MagScrew Total Artificial Heart (TAH) system is the result of a close collaboration among the Cleveland Clinic Foundation, Foster Miller Technologies, Wilson Greatbatch Ltd, and Whalen Biomedical Inc. The system components are the thoracic blood pumping unit with attached compliance chamber and refill port, implantable electronic control unit, implantable battery pack, transcutaneous energy transmission system, external battery pack, and a telemetry system for communication with the electronic control unit. System in vitro tests are underway for system characterization and durability demonstration, whereas in vivo tests were conducted to evaluate system performance and biocompatibility under physiologic conditions. The passively filling pump uses a left master alternate left and right ejection control mode and has a Starling law-like response to venous pressure. The in vitro tests documented excellent hydraulic pump performance with high device output of over 9 l/min at left atrial pressures below 12 mm Hg. Atrial balance was well maintained under all test conditions. The in vivo tests demonstrated good biocompatibility without use of anticoagulant therapy. Experimental durations have ranged between 0 and 92 days. Postexplant evaluation of tissue samples did not reveal any sign of thromboembolic events or tissue damage due to device operation.

Animals↗

Replacement of the left-side valves of an implanted total artificial heart.

The MagScrew total artificial heart (TAH) is under development. Despite its anticipated durability and reliability, the possibility of a bioprosthetic valve malfunction exists. As a result, the potential for valve replacement surgery, instead of device replacement, would be desirable after a TAH implant. In two of our 90-day animal experiments, we successfully replaced the left-side valves through a left thoracotomy opposite to the right-sided incision site for the initial TAH implant. The results of these cases suggest that the left-side valves could also be replaced through a left thoracotomy approach in humans. To confirm the ability to access the left-side valves in humans, four human cadaver studies were performed with the use of a mock pump designed for human application. This report describes the operative techniques for left-side valve replacement in animals and discusses the advantages of a left thoracotomy in clinical situations, based on results from the human cadaver studies.

Animals↗