A basket full of mechanistic insights into pulmonary vein arrhythmogenicity: reentry, focal activity, or fibrillatory conduction?
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Stephan Willems.
Explore the source record for details and available documents.
AIMS: To investigate the effectiveness of additional substrate modification (SM) by left atrial (LA) linear lesions as compared with pulmonary vein isolation (PVI) alone in patients with persistent atrial fibrillation (AF) in a prospective randomized study. Percutaneous PVI has evolved as an accepted treatment for paroxysmal AF but seemed to be less effective in patients with persistent AF. The benefit of PVI alone and additional linear lesions has not been validated in a randomized study so far. METHODS AND RESULTS: Sixty-two patients with persistent AF (median duration 7, range 1-18 months) were randomly assigned to either PVI alone (n = 30) or additional SM (n =32) consisting of a roof line connecting both left superior and right superior PV and LA isthmus ablation between left inferior PV and mitral annulus. Procedures including SM were performed using a three-dimensional mapping system (EnSite NavX, St Jude Medical, St Paul, MN, USA). Anti-arrhythmic drugs were discontinued within 8 weeks after ablation in both groups. Follow-up included daily trans-telephonic ECG transmitted irrespective of the patient's symptoms. PVI was successful in 98% of all targeted veins in both groups. Additional SM did not increase fluoroscopy time (72.1+/-18.7 vs. 72.9+/-17.3 min, P=0.92) because of the use of three-dimensional navigation in the PVI+SM group. AF recurrences within the first 4 weeks following ablation were more common after PVI alone (77%) than additional SM (44%, P=0.002). After a follow-up time of 487 (429-570) days, only 20% of patients undergoing stand alone PVI remained in sinus rhythm when compared with 69% following PVI combined with SM (P=0.0001). Two patients assigned to PVI+SM experienced procedure-related complications (cardiac tamponade and minor stroke) which resolved without sequelae. CONCLUSION: PVI alone is insufficient in the treatment of persistent AF. However, additional left linear lesions increase the success rate significantly. Early AF-relapses are associated with a negative outcome after PVI alone but not following additional SM.
BACKGROUND: Pre-interventional three-dimensional (3D) reconstruction of the heart by CT or MRI provides important information on cardiac anatomy for electrophysiological interventions. However, updates of 3D-imaging modalities with high soft-tissue contrast are not available during ablation procedures. OBJECTIVE: We describe the development and first clinical testing of a close to real-time visualization of cardiac anatomy by intracardiac echocardiography (ICE). METHODS: An electronic phased-array 5-10 MHz ICE-catheter (AcuNav/Siemens/64 elements) was inserted via a straightened femoral vein sheath (12F) and placed in the right atrium in 5 pigs. A custom-made prototype stepper motor allowed automatic rotation around the longitudinal axis from 90 degrees to 360 degrees in 2-5 degrees steps. For every plane 2D images of a complete cardiac cycle were acquired, triggered by respiration and ECG. The ultrasound images were digitized and 3D-reconstruction was performed by a prototype software. After experimental validation the system was tested in 6 patients during electrophysiological studies. RESULTS: From a single location in the right atrium, 3D-acquisition and reconstruction of both atria and ventricles with good image quality were achieved within 3-5 minutes. Doppler-mode facilitated identification of the great vessels including the pulmonary veins and their entry into the heart. 3D-visualization of ablation catheters was also possible in all patients and pigs. CONCLUSION: Semi-automated 3D intracardiac echocardiography from a single site inside the right atrium provides the electrophysiologist with a detailed image of both atria and ventricles with repeated updates of the cardiac anatomy.
BACKGROUND: Experimental data of simultaneous acquired activation and motion (AM) propagation from human subjects are not available. OBJECTIVES: The purpose of this study was to demonstrate the feasibility of a novel mapping technique allowing combined analysis of AM timing in vivo and to delineate the influence of chronically ischemic tissue on cardiac AM propagation. METHODS: Ten patients with remote myocardial infarction and 4 control patients were studied during sinus rhythm using electroanatomic mapping (CARTO). Maps of the left ventricle were obtained via the retrograde aortic approach. Real-time catheter positions were extracted using custom-made software. Catheter motion was analyzed along a static line connecting the catheter tip with the apex. Tissue Doppler measurements in all patients provided data for validation. RESULTS: Four shapes of catheter motion curves were identified and correlated to healthy tissue with variable degrees of preloading, scar tissue and dyskinetic regions, e.g. aneurysms. An analysis of the AM-delay revealed areas of delayed activation in 7, and slow motion onset in 4 patients. Tissue Doppler data correlated well with local onset of motion (correlation coefficient 0,99). CONCLUSION: Activation delays as well as long AM-intervals that can be differentiated with the described mapping technique are responsible for asynchronous contraction in the ischemic heart. Myocardial wall motion abnormalities can be derived from catheter motion curves.
Explore the source record for details and available documents.
AIMS: Paroxysmal atrial fibrillation (PAF) is predominantly triggered by focal ectopies located within the pulmonary veins (PV). The BITMAP Study (Breakthrough and Isolation Trial: Mapping and Ablation of Pulmonary Veins) investigated prospectively the safety and efficacy of a catheter design with circumferential mapping and ablation electrodes. We report the phenomenon of ST-segment-elevation during catheter placement in the left atrium (LA) and superior PVs in this multi-centre study. METHODS AND RESULTS: Forty-three patients (57+/-10 years) with PAF were included in this study. Radiofrequency catheter (RFC) ablation supported by the 4F REVELATION Helix microcatheter (Cardima Inc., Freemont, CA, USA) with eight distal-coiled microelectrodes for bipolar mapping and ablation. RFC was applied at the ostial region of PV (30 W, 45-50 degrees C) with a maximum of four RFC applications per electrode. In four of the 43 patients from three centres, we recorded the occurrence of ST-segment-elevation greater than 0.2 mV and accompanying left thoracic discomfort. The ECG changes and the symptoms started abruptly and lasted for 4.2+/-2.2 min. Pericardial effusion could instantaneously be excluded by echocardiography in all cases. Coronary angiograms were performed in three patients with the longest episodes; no thrombotic material or air emboli were present. The symptoms and the ECG changes resolved completely in all patients. CONCLUSION: The phenomenon of ST-segment-elevation during LA- and PV-mapping in patients with PAF may be a common occurrence. In this prospective multi-centre trial, we demonstrated the reversibility of this phenomenon; no cardiovascular or cerebral damage was reported during both the procedure and the follow-up. Although the mechanism is still unclear, vasospasm may contribute to this phenomenon because of autonomic dysregulation.
INTRODUCTION: Currently, definition of success following atrial fibrillation (AF) ablation is commonly based on the lack of symptoms. The purpose of this study was to evaluate the correlation between symptoms and the underlying rhythm after AF ablation. METHODS AND RESULTS: Eighty consecutive patients (pts) were treated for paroxysmal episodes of AF by segmental ostial ablation of all pulmonary veins and right atrial isthmus ablation. For 6 months pts transmitted transtelephonic (T-) ECG recordings in combination with comments daily or in the event of symptoms. Eligible comments were classified as: (1) asymptomatic, (2) symptomatic. Analysis was performed at 1-month intervals, defining an acute (first month) and chronic period (second to sixth month) after ablation. Overall 6,835 T-ECGs were analyzed. Of these 5,437 (79.5%) showed sinus rhythm (SR) and 1,398 (20.5%) showed AF. Pts in SR reported symptoms for 593 (10.9%) episodes, whereas 4,844 (89.1%) episodes were asymptomatic. During AF, 646 (46.2%) episodes were associated with symptoms, and 752 (53.8%) episodes remained asymptomatic. Exclusively asymptomatic were 7 (8.8%) pts. In 30 (52.6%) of 57 pts with AF, arrhythmic events were confined to the acute phase. Of the remaining 27 pts 14 (52%) reported an improvement, 12 (44%) the same, and 1 (4%) worsened symptoms after 3 months. A significant change (P < 0.01) toward more asymptomatic episodes from the acute (43.5%) to the chronic (57.5 +/- 4.5%) period was evident. CONCLUSION: Assessment of success after AF ablation cannot be based on the absence of symptoms due to a high prevalence of asymptomatic episodes.
INTRODUCTION: Pulmonary veins (PVs) are the predominant location of triggers for atrial fibrillation (AF), but little is known about the electrophysiologic properties of PVs. In addition, the influence of amiodarone on the electrophysiologic properties of PVs has not been elucidated. METHODS AND RESULTS: Fifty-five patients with symptomatic and drug-resistant AF were divided into two groups: group 1 patients (n=29) without antiarrhythmic drug therapy at the time of electrophysiologic study (EPS), and group 2 patients (n=26) undergoing continuous long-term treatment with amiodarone. EPS including programmed stimulation of both atria and within the PVs was performed in both groups. In group 1, the effective refractory period (ERP) of all PVs (174 +/- 62 msec) was significantly shorter than the ERP of the left atrium ([LA] 254 +/- 30 msec, P=0.0001) and right atrium ([RA] 221 +/- 29 msec, P=0.0001). The same pattern was observed in group 2 (PV: 210 +/- 58 msec; LA: 259 +/- 35 msec, P=0.0001; RA: 246 +/- 37 msec, P=0.0255). The ERP of all stimulated PVs was significantly lower in group 1 (174 +/- 62 msec) than in group 2 (210 +/- 58 msec; P=0.0001). The ERP of the left superior and right superior PVs and RA but not the left inferior PV and LA were significantly increased in patients treated with amiodarone. Decremental conduction properties were observed in all stimulated PVs, and there were no significantly differences between the maximal decrement of both groups. CONCLUSION: The distinctive electrophysiologic properties of PVs are emphasized by amiodarone therapy. Long-term amiodarone treatment is responsible for heterogeneous alteration of the PV electrophysiology, which may account for the individual antiarrhythmic responses in a subset of patients with paroxysmal AF.
INTRODUCTION: Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common regular supraventricular tachycardia in the general population as well as in elderly patients. The purpose of the study was to investigate the success and complication rate particularly regarding the induction of an atrioventricular (AV) block by radiofrequency (RF) ablation in elderly patients with and without a preexisting AV block. METHODS AND RESULTS: Between February 1998 and July 2004, all patients with symptomatic AVNRT referred for slow-pathway ablation in our institution were included and divided into two groups: group 1 patients younger than 75 years (n = 508) and group 2 patients > or =75 years (n = 70). A preexisting prolonged PR interval was present in 17 (3.3%) patients of group 1 and in 26 (37%, P < 0.0001) patients of group 2. Following successful slow-pathway ablation (follow-up time group 1: 37 +/- 22, group 2: 37 +/- 24 months) no induction of an AV block was observed in group 2 but in four patients of group 1 (0.79%) a complete heart block was induced requiring a pacemaker implantation. In group 1, 15 (2.95%) patients with a recurrence of AVNRT were readmitted for a repeat ablation procedure. No recurrences occurred in group 2. CONCLUSION: Despite a higher incidence of preexisting prolonged PR intervals slow-pathway ablation in elderly patients is both effective and safe and should be considered as the first line therapy also in this patient population.
AIM: Sub-threshold stimulation (STS) applied during atrioventricular nodal re-entrant tachycardia (AVNRT) of the common (slow-fast) type has been shown to effectively characterise target sites suitable for slow pathway (SP) ablation but has not been investigated in the setting of fast-slow and slow-slow variants. METHODS AND RESULTS: Seventeen consecutive patients (52+/-16 years, 12 female) with sustained uncommon type AVNRT (fast-slow: n = 13, slow-slow: n = 4) were investigated. Mapping of the SP was started postero-septally close to the coronary sinus ostium and continued toward mid-septal sites, if required. Target sites for STS were selected according to established criteria including the recording of the earliest retrograde atrial activation during AVNRT. Long duration (5 s) constant current STS during AVNRT variants was performed in a stepwise manner (max 5 mA) at each site eligible for SP ablation until termination or capture occurred. Radiofrequency current (RFC) was delivered following successful STS termination of tachycardia (65 degrees C, 60 s) and exclusion of catheter dislodgement. Uncommon AVNRT with a mean cycle length of 405+/-70 ms was induced without spontaneous termination in all patients. Interruption of AVNRT variants due to selective STS-induced block of the retrograde (n = 12) or anterograde (n =2) SP occurred without capture in 14/17 (82%) patients. This was exclusively observed at sites with successful subsequent RFC application. AVNRT was rendered non-inducible in all patients after a median of 1 (1-11) RFC pulses without complications. CONCLUSIONS: Uncommon AVNRT can be interrupted by STS delivered at subsequently successful target sites for SP ablation in most patients (82%). The high positive and negative concordance between the effects of STS and following RFC application indicates that STS-mapping is also useful in the setting of AVNRT variants.
INTRODUCTION: Pulmonary vein (PV) isolation for the curative treatment of atrial fibrillation using conventional radiofrequency ablation (RF) catheters with the point by point technique is time consuming and carries a remaining risk for thrombembolic complications. AIMS OF THE STUDY: Aim of the present in vivo study was to evaluate feasibility and safety of a novel multipolar irrigated ablation catheter designed to create contiguous lesions encircling the PV ostium in a single ablation position. METHODS: The entire ablation section (tripolar, length of each electrode 22 mm, interelectrode distance 2 mm, helix radius: 9 and 10 mm) of the 7F RF catheter (Encirclr, Medtronic, MN, USA) was covered by a porous membrane (pore size 30 micron) providing continuous irrigation. The helical formed catheter was used in two different experimental settings. Initially, a thigh muscle preparation has been performed in 7 anesthetized sheep in order to evaluate the development of lesions at different power level (40-80 W) and RF duration (30-90 sec). The ablation catheter was placed at the surface of the thigh muscle in a perpendicular position (0.1 N contact pressure) and perfused with heparinized blood (250 ml/min, 37C degrees ). Irrigation was provided with a flow rate of 10 ml/min. The resulted lesion morphology was evaluated with regard to coagulum or crater formation and lesion depth and diameter. Subsequently in 9 anesthetized sheep intracardiac ablation has been achieved with 50 W and an irrigation flow of 10 ml/min. Transseptal puncture and RF ablations were guided using fluoroscopy and intracardiac echocardiography (ICE, Acuson, USA). Endpoint of the intracardiac RF applications was the reduction of local electrogram amplitude >50%. RF applications were achieved at both atrial appendages and in the orifices of the coronary sinus (CS), the vena cava inferior (VCI) and PV. Following RF ablation all animals were sacrificed and following in vivo staining (2% TTC) macroscopically and histologically investigations of the lesions were performed. RESULTS: At the thigh muscle preparation 57 RF applications have been performed. The lesion depth was homogeneous without gaps between the ablation electrodes. There was a significant increase comparing 30 with 90 sec of RF duration for 40, 50 and 60 W applications respectively: 40 W: 1.1 +/- 0.4 vs. 3.6 +/- 0.5; 50 W: 1.2 +/- 0.3 vs. 4.6 +/- 0.4 mm and 60 W: 2.6 +/- 0.6 vs. 4.8 +/- 0.5 mm. All applications with 80 W (n = 3) had to be terminated due to immediate increase of impedance >150 omega. Late impedance rises (>60 sec) without occurrence of coagulum formation have been observed in 1 out of 4 RF applications with 60 W.A total of 85 RF applications could be achieved intracardiacally in the right atrium (right atrial appendage n = 18, ostium of the coronary sinus n = 12, ostium of the inferior caval vein: n = 12) and in the left atrium (left atrial appendage: n = 15, ostium of the PV: n = 28). ICE guided positioning of the catheter and showed during all applications no coagulum formation at the electrode or impedance rise (>150 Omega). Reduction of local electrograms (>50%) were observed following 48 out 85 (56%) RF applications. The lesions showed a homogeneous depth of 4 +/- 2 mm and a width 5 +/- 2 mm at the surface. No charring or crater formation could be observed in any of the lesions. CONCLUSIONS: In the present in vivo studies it could be demonstrated that long irrigated ablation electrodes induce continuous lesions without the risk of thrombus formation at the electrode. Increase of RF duration from 30 to 90 seconds with power setting of 40-60 W, respectively, created deeper lesions without the risk of thrombus formation. Thus, the helical formed irrigated ablation catheter appears to be appropriate for simplified PV isolation.
INTRODUCTION: EnSite NavX (NavX) is a novel mapping and navigation system that allows visualization of conventional catheters for diagnostic and ablative purposes and uses them to create a three-dimensional (3D) geometry of the heart. NavX is particularly suitable for ablation procedures utilizing an anatomic approach, as in the setting of common-type atrial flutter (AFL). The aim of this study was to compare NavX-guided and conventional ablation procedures for AFL. METHODS AND RESULTS: Forty consecutive patients (32 male, 59 +/- 12 years) with documented AFL were randomized to undergo fluoroscopy-guided (group I, 20 patients) or NavX-guided (group II, 20 patients) ablation, including 3D isthmus reconstruction. The same catheter setup was used in both groups. The endpoint of bidirectional isthmus block was obtained in all patients. Compared to conventional approaches, NavX-guided procedures significantly reduced fluoroscopy time (5.1 +/- 1.4 min vs 20 +/- 11 min, P < 0.01) and total x-ray exposure (5.1 +/- 3.1 Gycm2 vs 24.9 +/- 1.6 Gycm2, P < 0.01). Isthmus geometry reconstruction could be performed in all patients of group II. In 4 patients (20%) of group II, anatomic isthmus variations were detected by NavX. No significant differences in radiofrequency current applications and procedural times were found between the two groups. CONCLUSION: NavX technology allows geometry reconstruction of the cavotricuspid isthmus. NavX-guided ablation of AFL reduces total x-ray exposure compared to the fluoroscopy-guided approach but does not prolong procedure time.
INTRODUCTION: Open cooled-tip and solid 8-mm-tip catheters have demonstrated safety and effectiveness for radiofrequency current (RFC) ablation of typical atrial flutter (AFL). However, data from prospective and randomized studies in this setting are lacking. METHODS AND RESULTS: One hundred thirty consecutive patients (104 men; 61 +/- 11 years) with AFL were randomized to undergo RFC catheter ablation either using a solid 8-mm-tip catheter (group A, 65 degrees C, 70 W, 60 s) or an open irrigated-tip catheter (group B, 65 degrees C, 50 W, 60 s, 17 mL/min flow). Endpoint was bidirectional conduction isthmus block. In cases of repeated (two times) transient isthmus block, the catheter was changed (crossed over) to the catheter used in the other randomization arm, but patients remained in the original group following intention-to-treat analysis. The selected endpoint could be achieved in all patients after 12 +/- 6 RFC pulses in group A and 10 +/- 7 RFC pulses in group B (P = 0.11). Procedure times were longer (159 +/- 38 min vs 138 +/- 37 min, P = 0.002) and x-ray exposures higher in group A (fluoroscopy time 25 +/- 17 min vs 21 +/- 10 min, P = 0.08; x-ray dosage 3,133 +/- 2,576 cGy.cm2 vs 2,326 +/- 1,405 cGy.cm2, P = 0.03). Transient isthmus block was observed in 23 group A patients and 12 group B patients (P = 0.03). Onset time of transient isthmus block ranged from 0.5 to 27 minutes. Repeated transient isthmus block occurred in 8 of the 23 patients in group A after 19 +/- 3 RFC applications. After crossover to the cooled-tip catheter, the endpoint was reached another 5 +/- 1 RFC pulses. In group B, all patients could be treated without change of ablation catheter. After a follow-up of 14 +/- 2 months, 2 patients (3%) in group A and 1 patient (1.5%) in group B presented with AFL recurrence. CONCLUSION: Open cooled-tip catheters are more effective than solid large-tip catheters for AFL ablation. The greater effectiveness is evident in cases showing repeated conduction recovery within the cavotricuspid isthmus. Primary use of open irrigated-tip catheters should be considered for AFL ablation.
This case report describes a patient with a sustained monomorphic VT after surgical repair of a tetralogy of Fallot (TOF). In combination with the three-dimensional electroanatomic mapping system, CARTO, and conventional mapping techniques the VT was identified as a macro-reentrant tachycardia circling around the border between pulmonary graft and right ventricular outflow tract (RVOT). A y-shaped ablation line crossing this zone was created. The VT terminated during RF application and was not inducible again. This case underlines the use of a combined conventional and three-dimensional electroanatomic mapping technique can be helpful for catheter ablation of ventricular arrhythmias in TOF patients.
Pulmonary vein (PV) isolation for the treatment of atrial fibrillation is limited by procedure related complications, such as PV stenosis and occlusions. We report about a PV isolation using a circumferential cryoablation catheter which applies the ablation energy simultaneously at the entire circumference by cooling down to a minimal temperature of -80 degrees C.
We report the case of a 31-year-old woman with a 4-year history of recurrent palpitations, presenting with an increased frequency of paroxysms caused by ventricular tachycardias during pregnancy. A cardiac tumor of unknown origin infiltrating the right ventricle was diagnosed. Three weeks after prophylactic abrasion the tumor was totally excised with the use of cardiopulmonary bypass including restoration of the right ventricular wall and the tricuspid valve. Histology confirmed diagnosis of a benign cardiac lipoma. The postoperative course was uneventful and the patient was discharged 7 days after surgery. There was no episode of ventricular tachycardias during the 6-month follow-up.
The most widely accepted criterion for successful radiofrequency catheter (RFC) ablation of typical atrial flutter is the development of bi-directional isthmus block. In a subset of patients, conventional RFC ablation fails to achieve this endpoint because deeper and wider lesions are required. We investigated the efficacy of a long 8-mm tip catheter in these cases. One hundred and seventy-four consecutive patients (137 male; 61 +/- 9 years) with recurrent typical atrial flutter underwent conventional RFC ablation first with a standard 4 mm tip catheter. In resistant cases (n = 52), ablation was continued using a large tip 8-mm catheter when the 4-mm tip catheter failed. Resistant atrial flutter was identified when 21 RFC pulses failed to reach the selected endpoint of bi-directional isthmus block or in cases of transient bi- directional block (at least 3 episodes). In 122 of the 174 patients (70%) conventional atrial flutter ablation was successfully performed with 13 +/- 5 RFC applications. In the remaining 52 subjects (30%), the ablation procedure was completed using the large tip electrode catheter. In 30 of these 52 patients (58%), the catheter was changed because of persistent intra-atrial conduction after 21 RFC pulses and in 22 (42%) because of intermittent conduction block after 11 +/- 5 applications. Using the large tip electrode catheter, the selected endpoint was achieved in all patients of both groups with 3 +/- 2 RFC pulses (power output of 50-60 W, pulse duration of 60 sec). No post-procedure complications were observed. After 15 +/- 5 months of follow-up, 16 patients (9%) had recurrence of atrial flutter. Five of the patients had been in the resistant group. In patients with atrial flutter resistant to conventional ablation therapy, the long tip (8-mm) catheter appears to be a safe and effective alternative to use of the conventional 4-mm tip catheter.
The present study sought to investigate the electrophysiological properties of isolated pulmonary veins following successful radiofrequency (RF) catheter ablation in patients with paroxysmal atrial fibrillation (PAF). Overall, 71 pulmonary veins in 37 consecutive patients (age: 56 +/- 9 years) with recurrent PAF were targeted for RF ablation at the ostial region in order to achieve a complete functional block. Following disconnection, the incidence of dissociated pulmonary vein (PV) activity and its response to orciprenalin were studied. RF ablation abolished conduction in 67 (94%) of 71 potentially arrhythmogenic PVs after a mean of 10.7 +/- 6.4 RF applications for each PV. After ablation, spontaneous dissociated automatic activity (9 to 52 beats/min, median 27) was found in 6 out of 67 isolated PVs (left superior: n = 1, left inferior: n = 1, right superior: n = 2, common left PV: n = 2). Slight acceleration (13 to 68 beats/min, median 29) of dissociated PV activity was observed during infusion of orciprenalin. Following isolation, initiation of sustained or nonsustained local fibrillation was recorded in only two cases of the common left sided PV with preceding automatic activity. In one patient PV fibrillation occurred during orciprenalin infusion following a repetitive response to a dissociated automatic rhythm with increasing duration as well as destabilization. In the other patient, PV fibrillation occurred immediately after the occurrence of PV automaticity. Slow dissociated automatic rhythms are detectable within 9% of disconnected PVs. The unique anatomic substrate of common left PVs seem to favor the occurrence of local fibrillation following isolation. The initiation pattern of fibrillation within the isolated PV has pathophysiological implications and underlines the contribution of multiple factors to the onset and sustenance of PAF.