A prospective registry to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions using the "crush technique".

The "crush technique" has been proposed as an alternative approach to treat bifurcation lesions because of its predictability and high procedural success rate. However, few data are available regarding its safety and long-term efficacy. We report the long-term clinical outcomes of patients with coronary bifurcation lesions treated with sirolimus-eluting stents using the crush technique. From April 2003 to May 2004, 120 patients with coronary bifurcation lesions were treated with sirolimus-eluting stents using the crush technique. Six months of clinical follow-up was completed in 95.8% of patients. Mean patient age was 64 years; 36% had diabetes mellitus, and the left anterior descending artery/diagonal was the most frequent bifurcation location (69%). Final kissing balloon inflation was performed in 87.5% of patients. Compared with the main vessel, side branch lesions were shorter, with a smaller reference diameter and final in-stent minimum lumen diameter. Procedural success was achieved in 97.5%. At 30 days of follow-up, 1 patient had died of noncardiac causes and 2 patients (1.7%) had subacute stent thrombosis. At 6 months of follow-up, target lesion revascularization was required in 13 patients (11.3%), all of whom had focal restenosis predominantly at the side branch ostium. In conclusion, the crush technique with final kissing balloon inflation can be safely used by experienced operators to treat highly complex bifurcation lesions with sirolimus-eluting stents. The safety profile of this technique is similar to that of other bifurcation stenting techniques reported thus far. Nonetheless, despite the excellent patency rates of the main vessel, the need for revascularization at the ostium of the side branch was not fully eliminated.

Angioplasty, Balloon, Coronary↗

IVUS makes important strides in 2005.

Researchers utilized intravascular ultrasound in unique ways in 2005, from assessing transplant vasculopathy to evaluating long-term drug-eluting stent outcomes to identifying predictors of stent thrombosis. These and other applications signify key developments in the field of intravascular imaging.

Blood Vessel Prosthesis Implantation↗

Bifurcation coronary lesions treated with the "crush" technique: an intravascular ultrasound analysis.

OBJECTIVES: We report intravascular ultrasound (IVUS) findings after crush-stenting of bifurcation lesions. BACKGROUND: Preliminary results with the crush-stent technique are encouraging; however, isolated reports suggest that restenosis at the side branch (SB) ostium continues to be a problem. METHODS: Forty patients with bifurcation lesions underwent crush-stenting with the sirolimus-eluting stent. Postintervention IVUS was performed in both branches in 25 lesions and only the main vessel (MV) in 15 lesions; IVUS analysis included five distinct locations: MV proximal stent, crush area, distal stent, SB ostium, and SB distal stent. RESULTS: Overall, the MV minimum stent area was larger than the SB (6.7 +/- 1.7 mm2 vs. 4.4 +/- 1.4 mm2, p < 0.0001, respectively). When only the MV was considered, the minimum stent area was found in the crush area (rather than the proximal or MV distal stent) in 56%. When both the MV and the SB were considered, the minimum stent area was found at the SB ostium in 68%. The MV minimum stent area measured <4 mm2 in 8% of lesions and <5 mm2 in 20%. For the SB, a minimum stent area <4 mm2 was found in 44%, and a minimum stent area <5 mm2 in 76%, typically at the ostium. "Incomplete crushing"--incomplete apposition of SB or MV stent struts against the MV wall proximal to the carina--was seen in >60% of non-left main lesions. CONCLUSIONS: In the majority of bifurcation lesions treated with the crush technique, the smallest minimum stent area appeared at the SB ostium. This may contribute to a higher restenosis rate at this location.

Angioplasty, Balloon, Coronary↗

Noninvasive tests for arterial structure, function, and compliance: do they identify risk or diagnose disease?

BACKGROUND: Brachial artery reactivity (BAR), carotid intima-media thickness (IMT), and applanation tonometry for evaluation of total arterial compliance may provide information about preclinical vascular disease. We sought to determine whether these tests could be used to identify patients with coronary artery disease (CAD) without being influenced by their ability to identify those at risk for CAD developing. METHODS: We studied 100 patients and compared 3 groups: 35 patients with known CAD; 34 patients with symptoms and risk factors but no CAD identified by stress echocardiography (risk group); and 31 control subjects. BAR and IMT were measured using standard methods, and total arterial compliance was calculated by the pulse-pressure method from simultaneous radial applanation tonometry and pulsed wave Doppler of the left ventricular outflow. Ischemia was identified as a new or worsening wall-motion abnormality induced by stress. RESULTS: In a comparison between the control subjects and patients either at risk for developing CAD or with CAD, the predictors of risk for CAD were: age (P =.01); smoking history (P =.002); hypercholesterolemia (P =.002); and hypertension (P =.004) (model R = 0.82; P =.0001). The independent predictors of CAD were: IMT (P =.001); BAR (P =.04); sex (P =.005); and hypertension (P =.005) (model R = 0.80; P =.0001). CONCLUSION: IMT, BAR, and traditional cardiovascular risk factors appear to identify patients at risk for CAD developing. However, only IMT was significantly different between patients at risk for developing CAD and those with overt CAD.

Aged↗

Arterial wall strength after endovascular photodynamic therapy.

BACKGROUND AND OBJECTIVES: Vascular photodynamic therapy (PDT) inhibits intimal hyperplasia (IH) induced by angioplasty in rat iliac arteries by eradicating the proliferating smooth muscle cells. This process may jeopardise the structure and strength of the arterial wall, reflected by a decreased bursting pressure. STUDY DESIGN/MATERIALS AND METHODS: Thirty male Wistar rats of 250-300 g were subdivided into 3 groups (n = 10). In all groups, IH was induced by balloon injury (BI). One experimental group received PDT at 50 J/cm diffuser length, the other group at 100 J/cm diffuser length. The third group served as control group and received no PDT. In half of each group the bursting pressure was analyzed after 2 hours (n = 5), in the other half after 1 year. RESULTS: Two hours after the procedure the bursting pressure was 3.37 +/- 0.58 (+/-SEM) bar in the BI + PDT 50 and 3.96 +/- 0.43 bar in the BI + PDT 100 group, compared to 2.20 +/- 0.27 bar in the BI group (P < 0.05). After 1 year these values were 3.18 +/- 0.87 bar in the BI + PDT 50 (P < 0.05) and 2.02 +/- 0.31 bar in the BI + PDT 100 group, compared to 2.10 +/- 0.30 bar in the BI group (NS). In the BI + PDT 100 group, 3 out of 5 rats appeared to have aneurysmal dilatation after 1 year. CONCLUSIONS: Endovascular PDT increases the arterial wall strength as measured by the bursting pressure at short-term. After 1 year, wall strength is not diminished as measured by bursting pressure, but aneurysmal dilatation nevertheless developed with 100 J/cm. dl. This may limit the use of high energy PDT.

Aminolevulinic Acid↗

Quantitative IVUS blood flow: validation in vitro, in animals and in patients.

In recent years, a new method to measure transverse blood flow based on the decorrelation of the radiofrequency (RF) signals of intravascular ultrasound (IVUS) rotating single-element scanners was introduced. We report here in vitro, animal and patient testing to evaluate the correlation-based method using an IVUS array catheter. A new correlation-based method to dynamically correct the correlation coefficients for noise is implemented. The decorrelation due to noise was estimated from the correlation coefficients from flowing blood obtained at increasing time lags. First, blood flow experiments were carried out with different catheters in a tissue-mimicking flow phantom with an inner diameter ranging from 3.0 to 5.0 mm. A calibrated electromagnetic flow meter (EMF, range: 0 to 250 cc/min) was used as a reference. Good linear relationships were found between the IVUS-derived flow and the calibrated EMF (all R(2)> 0.96). The catheter position within the flow phantom and the size of the ring-down were theoretically analyzed. These elements, and noise in the RF signals, have an important influence on the IVUS blood flow measurements reflected by the offset and the slope of the linear relationships. By placing the IVUS catheter outside the flow phantom, parabolic blood flow profiles were also measured. Second, IVUS blood flow measurements were performed in the carotid artery of two Yorkshire pigs, which showed linear relationships (all R(2)> 0.85) between the IVUS-derived flow and the calibrated EMF. Experimentally, the offset was lower than 3 mL/min and the slope was close to 1. Third, IVUS blood flow measurements were performed in coronary arteries in patients. Preliminary results for the coronary flow reserve (CFR = high flow/baseline flow) in patients using the decorrelation method of RF signals of an array IVUS scanner were comparable with CFR based on Doppler measurements.

Animals↗

A new intracoronary measurement catheter, MetriCath, compared to intravascular ultrasound and quantitative coronary angiography in a stented porcine coronary model.

The purpose of this study was to compare measurements by MetriCath to intravascular ultrasound (IVUS) and quantitative coronary angiography (QCA). The MetriCath system consists of a low-pressure (200 mm Hg) balloon catheter connected to a pressure transducer and infusion pump linked to a computer that records pressure-volume curves. Cross-sectional area of blood vessels is obtained directly from the unrestrained and in-stent pressure-volume measurements. We compared stent cross-sectional area measurements by MetriCath, IVUS, and QCA in a porcine stented coronary artery model. Comparison of area measurements in 14 stents showed no significant differences between the three methods (P = 0.66). On average, values differed 0.37 +/- 0.60 mm(2) between MetriCath and QCA, 0.13 +/- 0.55 mm(2) between MetriCath and IVUS, and 0.22 +/- 0.80 mm(2) between IVUS and QCA. This corresponds to 6.2% +/- 10%, 3.0% +/- 9.0%, and 3.1% +/- 12.9% relative difference from the average of two corresponding measurements. Linear regression analysis showed excellent correlation between measurements (r = 0.99 for all comparisons). The differences in in-stent area measurements between MetriCath and both QCA and IVUS were small. Considering the ease and rapidity of obtaining MetriCath results, this technique may form an alternative to the others in evaluating stent expansion. Based on these findings, clinical evaluation seems warranted.

Animals↗

High shear stress after successful balloon angioplasty is associated with restenosis and target lesion revascularization.

BACKGROUND: Vascular wall shear stress (WSS) has been implied in the pathogenesis of atherosclerosis and vascular remodeling. Our aim was to calculate WSS after balloon angioplasty and evaluate its predictive value for long-term outcome. METHODS: WSS was calculated proximal to, in, and distal to the lesion after angiographically successful balloon dilatation and at follow-up with the Hagen-Poiseuille formula (WSS = 4 microQ/piR3) in 202 patients. Volumetric blood flow (Q) and lumen radius (R) were derived from Doppler scanning velocities and videodensitometric cross-sectional areas. RESULTS: Postprocedural proximal and in-lesion values were higher in vessels that developed restenosis (n = 72; 1.22 +/- 0.61 N/m2 and 3.61 +/- 2.38 N/m2, respectively) than in those without restenosis (n = 130, 1.05 +/- 0.51 N/m2 and 2.46 +/- 1.39 N/m2, respectively; P <.05). In-lesion WSS was revealed to be predictive of restenosis by means of logistic regression analysis (odds ratio [OR] = 1.42, P <.05), whereas WSS of the proximal segment was associated with an increased rate of target lesion revascularization (OR = 2.33, P <.005). In the multivariate regression model, WSS of the proximal segment was the only independent predictor when entered with known predictors such as diameter stenosis and coronary flow reserve (OR = 2.15, P <.05). CONCLUSIONS: WSS in the lesion after balloon angioplasty is predictive of angiographic restenosis. Moreover, the proximal value is an independent predictor of target lesion revascularization. This study opens perspectives for the on-line use of WSS as a combined parameter of anatomy and physiology to assess the necessity of adjunctive therapy after successful balloon dilatation.

Angina Pectoris↗

Application of beta-irradiation through the struts of a previously deployed stent.

The application of beta-radiation in coronary arteries is a promising new technique for the treatment of in-stent restenosis. This is the first case in which the 5 F. delivery catheter of the Beta-Cath trade mark system was advanced through the struts of a stent, previously deployed in an adjacent branch, so as to deliver radiation to the target vessel.

Journal Article↗