Role of Purkinje conducting system in triggering of idiopathic ventricular fibrillation.

Ventricular fibrillation is the main mechanism of sudden cardiac death, but the source of its spontaneous initiation has not been mapped. 16 patients were investigated by electrography and radiofrequency ablation after resuscitation from recurrent idiopathic ventricular fibrillation. Triggers of ventricular fibrillation originated from various locations within the Purkinje system in 12 patients and from the ordinary myocardial muscle in four. The accuracy of mapping was confirmed by acute elimination of triggers by radiofrequency delivery, and there was no recurrence of ventricular fibrillation in 14 patients. Long-term follow-up is necessary to establish that ablation is curative and avoids use of a defibrillator.

Adolescent↗

Benefit of atrial pacing in sleep apnea syndrome.

BACKGROUND: Many patients with sleep apnea syndrome have nocturnal bradycardia, paroxysmal tachyarrhythmias, or both, which can be prevented by permanent atrial pacing. We evaluated the effect of using cardiac pacing to increase the heart rate during sleep in patients with sleep apnea syndrome. METHODS: We studied 15 patients (11 men and 4 women; mean [+/-SD] age, 69+/-9 years) with central or obstructive sleep apnea who had received permanent atrial-synchronous ventricular pacemakers for symptomatic sinus bradycardia. All patients underwent three polysomnographic evaluations on consecutive nights, the first night for base-line evaluation and then, in random order, one night in spontaneous rhythm and one in dual-chamber pacing mode with atrial overdrive (basic rate, 15 beats per minute faster than the mean nocturnal sinus rate). The total duration and number of episodes of central or obstructive sleep apnea or hypopnea were analyzed and compared. RESULTS: The mean 24-hour sinus rate during spontaneous rhythm was 57 +/- 5 beats per minute at base line, as compared with 72 +/- 3 beats per minute with atrial overdrive pacing (P<0.001). The total duration of sleep was 321 +/- 49 minutes in spontaneous rhythm, as compared with 331 +/- 46 minutes with atrial overdrive pacing (P=0.48). The hypopnea index (the total number of episodes of hypopnea divided by the number of hours of sleep) was reduced from 9 +/- 4 in spontaneous rhythm to 3 +/-3 with atrial overdrive pacing (P<0.001). For both apnea and hypopnea, the value for the index was 28 +/- 22 in spontaneous rhythm, as compared with 11 +/- 14 with atrial overdrive pacing (P<0.001). CONCLUSIONS: In patients with sleep apnea syndrome, atrial overdrive pacing significantly reduces the number of episodes of central or obstructive sleep apnea without reducing the total sleep time.

Aged↗

Performance of a rate responsive accelerometer-based pacemaker with autocalibration during standardized exercise and recovery.

The rate responsiveness of a single chamber, accelerometer-based pacemaker with an autocalibration function (Opus G VVIR pacemaker, ELA Medical) was studied with a daily life protocol developed to automatically optimize the programming of accelerometer-based sensors. This new sensor was compared with two other body activity sensors that were manually optimized patient by patient. Forty-three pacemaker recipients (mean age 71 +/- 11 years), paced > 95% of the time, underwent a daily life protocol consisting of rapid walking for 6 minutes (W), climbing upstairs for 1.5 minutes (U), and downstairs for 1.5 minutes (D), alternated by recovery phases. The results were compared with performances measured in a control population of healthy subjects and in two paced patient populations (one equipped with a Dash Intermedics VVIR pacemaker and the other equipped with a Sensolog III Pacesetter/St. Jude VVIR pacemaker). Sex distribution and mean age between paced patients and control subjects were statistically comparable. The mean heartrate achieved by all paced patients at each time sample was compared with the normograms, assigning acceleration (slope) and rate (rate) scores for exercise and recovery phases. Scores ranged from -10 (hypochronotropic) to +10 (hyperchronotropic). Zero represents exact concordance with the responses of healthy individuals, and values between -2.5 and +2.5 were considered statistically similar to normal. During W, although the overall performances of the Dash, Sensolog, and Opus G did not statistically differ from healthy controls, the scores obtained by the Opus G were significantly closer to controls than those of the two other pacemakers (P = 0.02). For U, the three sensors were hypochronotropic (P = 0.03), though the Opus G was associated with a heart rate response closer to that of healthy controls (P = 0.04). D provided similar mean heart rate scores for the Opus G and the Dash compared with healthy controls, in contrast with the hyperchronotropic behavior of the Sensolog (P = 0.02). Opus G revealed a physiological modulation of the heart rate for W and D tests with a slightly hypochronotropic behavior during U. The Opus G autocalibration function provided daily life performances closer to those of healthy controls than two other pacemakers equipped with a body activity sensor that were manually optimized.

Aged↗