Thrombosis of prosthetic heart valves: diagnosis and therapeutic considerations.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Stephane Lafitte.
Explore the source record for details and available documents.
A 44-year-old man presented with atypical chest pain and dyspnea. Investigation revealed the presence of a 15-mm rounded, well-vascularized left-ventricular mass. The mass was removed surgically and histopathologic evaluation identified a cardiac hemangioma.
OBJECTIVES: In normal hearts, the distribution of regional myocardial perfusion is altered by ventricular pacing. Little is known about the impact of ventricular pacing on regional myocardial perfusion in ischemic conditions. In this acute echocardiographic study, we compared the respective effects of right ventricular pacing (RVP), left ventricular pacing (LVP), and biventricular pacing (BVP) on regional perfusion in a swine model of graded ischemia. METHODS AND RESULTS: Ventricular pacing leads were placed at the apex of the right ventricle and on the lateral wall of the left ventricle in nine open-chest pigs. Myocardial contrast echocardiography was successively performed during spontaneous rhythm (SR), RVP, LVP, and BVP in random order at baseline and during three stages of incremental ischemia (left anterior descending + circumflex). At baseline, RVP decreased myocardial perfusion of the septal and inferior walls compared to SR (P < 0.05), whereas LVP decreased perfusion of the lateral wall (P < 0.05). No significant differences were observed in regional perfusion during BVP compared to SR. In ischemic conditions, RVP worsened myocardial perfusion in the ischemic anterior wall as well as in the septal and inferior walls (P < 0.05), whereas both LVP and BVP did not alter perfusion in the ischemic area compared to SR. CONCLUSION: Compared to baseline, in ischemic conditions, RVP has a more pronounced detrimental impact on perfusion abnormalities. In contrast, BVP induced a significant improvement in local myocardial perfusion. Therefore, BVP could be preferred to RVP in patients with ischemic cardiomyopathy.
OBJECTIVES: We sought to assess the effects of exercise on ventricular dyssynchrony in patients with normal and depressed left ventricular (LV) function. BACKGROUND: Asynchronous myocardial contraction adversely influences ventricular function and is associated with a poor prognosis in heart failure. Exercise-induced changes in ventricular dyssynchrony may be an important determinant of dynamic changes in cardiac output and mitral regurgitation. METHODS: A total of 65 consecutive heart failure patients and 50 matched healthy control patients underwent exercise echocardiography. Conventional and tissue Doppler parameters were measured before and during symptom-limited exercise. Left ventricular dyssynchrony was defined as the standard deviation of 12 LV segmental electromechanical delays. Analysis of the control group allowed delimitation of normal cutoff values. RESULTS: In patients with normal left ventricular function, exercise did not modify the extent of LV asynchrony. In contrast, in heart failure patients, LV dyssynchrony increased by at least 20% in 34%, remained stable in 37%, and decreased by at least 20% in 29%. Moreover, 26% of heart failure patients had either exercise induction or normalization of ventricular dyssynchrony. A significant association was found between exercise-induced changes in dyssynchrony and the presence of ischemic cardiomyopathy (p < 0.05). Rest-exercise differences in ventricular dyssynchrony were correlated with changes in cardiac output and mitral regurgitation (r = -0.63 and 0.56, respectively). CONCLUSIONS: In heart failure patients, exercise can alter the magnitude of ventricular dyssynchrony. Some patients have a response to exertion with induction of ventricular dyssynchrony, whereas others show normalization. Changes in ventricular dyssynchrony during exercise correlate with alterations in cardiac output and mitral regurgitation.
This prospective echocardiographic study investigated the respective impacts of left ventricular (LV) pacing and simultaneous and sequential biventricular pacing (BVP) on ventricular dyssynchrony during exercise in 23 patients with compensated heart failure and ventricular conduction delays. During exercise, LV pacing and BVP significantly (p <0.05) improved mitral regurgitation and LV dyssynchrony compared with spontaneous activation. LV segmental electromechanical delays were significantly prolonged during LV pacing, leading to increased systolic time (p <0.05), decreased LV filling time (p <0.05), and decreased stroke volume (p <0.05) compared with BVP. After optimization of the interventricular delay with sequential BVP, additional benefit was obtained during exercise in terms of stroke volume and mitral regurgitation (p <0.05). The optimal interventricular delay was different at rest and during exercise in 57% of the patients. Changes from at rest to exercise in LV dyssynchrony were correlated with changes in stroke volume (r = -0.61, p <0.01) and changes in mitral regurgitation (r = 0.60, p <0.01).
Quantitative coronary angiography (QCA) is routinely performed before valve surgery for severe acquired valvular disease. This technique is relatively invasive, especially in a population with an average risk for significant coronary stenosis. Multidetector computed tomography (MDCT) coronary angiography allows the noninvasive evaluation of the coronary anatomy. The aim of this prospective study was to evaluate the predictive values of 16-slice MDCT in the detection of significant coronary stenosis (> or = 50%) before valve surgery in patients with severe valvular disease without known coronary artery disease and average risk, in comparison with conventional QCA. Forty patients with severe acquired valvular disease (mean age 70 +/- 8.6 years; 20 women; 27 with severe aortic stenosis) underwent coronary MDCT 2 days before cardiac catheterization with QCA. The mean heart rate was 64.7 +/- 8.8 beats/min (range 41 to 78). Four hundred fifty-eight of 600 coronary artery segments (77.3%) were considered assessable by MDCT. In a per-segment analysis, the sensitivity of MDCT for the detection of significant coronary lesions > or = 50% was 77.7%, the specificity was 98%, the positive predictive value was 42.4%, and the negative predictive value was 99%. The main cause of false-positive or false-negative results or nonassessable evaluations was severe coronary calcification. In a per-patient analysis, in comparison with QCA, MDCT correctly classified 33 of 40 patients (82.5%). In conclusion, in patients with an average risk for coronary stenosis before valve surgery, MDCT coronary angiography detected significant obstructive coronary artery disease, with a 99% NPV.
OBJECTIVES: Recently, a novel method to measure strain from standard two-dimensional images has been developed. Our goal was to characterize global and regional systolic function abnormalities using this technique in patients with hypertrophic cardiomyopathy (HCM). BACKGROUND: Strain has been proposed as a sensitive tool to detect early systolic function abnormalities in HCM. However, the clinical application of conventional Doppler-derived strain has been limited by poor reproducibility and angle dependency. METHODS: Echocardiographic examinations were performed in 26 patients with nonobstructive HCM and 45 healthy subjects. Using a dedicated software package, bidimensional acquisitions were analyzed to measure longitudinal and transverse strain in apical views and circumferential and radial strain in parasternal short-axis view. RESULTS: Despite apparently normal left ventricular systolic function, all components of strain were significantly reduced in HCM. Average longitudinal, transverse, circumferential, and radial strain in patients with HCM and controls were -15.1 +/- 6.2% versus -20.3 +/- 5.6%, 23.3 +/- 17.0% versus 27.2 +/- 14.9%, -16.8 +/- 7.1% versus 19.6 +/- 5.2%, and 25.2 +/- 13.9% versus 36.8 +/- 17.2%, respectively (all p < 0.001). In patients with asymmetrical HCM, longitudinal septal strain was significantly lower than for other left ventricular segments combined: -9.2 +/- 4.7% versus -12.7 +/- 7.1% (p = 0.001). Average interobserver and intraobserver variabilities were 11% and 11.3%, respectively. CONCLUSIONS: Two-dimensional strain is a new simple, rapid, and reproducible method to measure different components of systolic strain. This technique identified early abnormalities in patients with HCM that have apparently normal left ventricular systolic function.
OBJECTIVE: The aims of this study were to investigate absolute assessment of aortic valve area (AVA), before surgery for aortic stenosis, using cardiovascular magnetic resonance (CMR) in comparison with transesophageal echocardiography (TEE) and with effective AVA indirectly obtained by routine techniques i.e. transthoracic echocardiography (TTE) and cardiac catheterisation. MATERIALS AND METHODS: Absolute AVA planimetry was performed by TEE and CMR steady state free precession sequences obtained through the aortic valvular plane. Effective AVA was calculated by the continuity equation in TTE and by cardiac catheterisation (Gorlin formula). RESULTS: Thirty-nine patients with aortic valve stenosis, mean age 71.7 +/- 7.6 years, with a mean AVA of 0.93 +/- 0.31 cm2 as measured by TEE, were enrolled in the study. Mean differences were: between CMR and TEE planimetry: d = 0.01 +/- 0.14 cm2, between CMR and cardiac catheterisation: d = 0.05 +/- 0.13 cm2, between CMR and TTE: d = 0.10 +/- 0.17 cm2, between TTE and TEE: d = 0.10 +/- 0.18 cm2, between TTE and cardiac catheterisation: d = 0.06 +/- 0.16 cm2, and between TEE and cardiac catheterisation: d = 0.07 +/- 0.13 cm2. Mean intraobserver and interobserver differences of CMR planimetry were d = 0.02 +/- 0.07 cm2 and d = 0.03 +/- 0.14 cm2, respectively. CONCLUSION: CMR planimetry of the AVA is a noninvasive and reproducible technique to evaluate stenotic aortic valves and can be used as an alternative to echocardiography or cardiac catheterisation.
OBJECTIVES: To define the use of cineventriculography, cardiac magnetic resonance imaging (cMRI), and unenhanced and contrast-enhanced echocardiography for detection of left ventricular (LV) regional wall motion abnormalities (RWMA). BACKGROUND: Detection of RWMA is integral to the evaluation of LV function. METHODS: In 100 patients, cineventriculography and unenhanced and contrast-enhanced echocardiography were performed. Fifty-six of the patients underwent additional cMRI. RWMA were assessed referring to a 16-segment model for cMRI, unenhanced and contrast echocardiography. Cineventriculography was evaluated on a 7-segment model. Hypokinesia in one or more segments defined presence of RWMA. Interobserver agreement among three readers was determined within each imaging modality. Intermethod agreement between imaging modalities was analyzed. A standard of truth for the presence of RWMA was obtained by an independent expert panel decision (EPD) based on clinical data, electrocardiogram, coronary angiography, and blinded information from the imaging modalities. RESULTS: Sixty-seven patients were found to have an RWMA by EPD. Interobserver agreement expressed as kappa coefficient was 0.41 (range 0.37 to 0.44) for unenhanced echocardiography, 0.43 (range 0.29 to 0.79) for cMRT, 0.56 (range 0.44 to 0.70) for cineventriculography, and 0.77 (range 0.71 to 0.88) for contrast echocardiography. Contrast enhancement compared to unenhanced echocardiography improved agreement of echocardiography related to cMRI (kappa 0.46 vs. 0.29) and related to cineventriculography (kappa 0.59 vs. 0.28). Accuracy to detect EPD-defined RWMA was highest for contrast echocardiography, followed by cMRI, unenhanced echocardiography, and cineventriculography. CONCLUSIONS: Analysis of RWMA is characterized by considerable interobserver variability even using high-quality imaging modalities. Interobserver agreement on RWMA and accuracy to detect panel-defined RWMA is good using contrast echocardiography.
Cardiac support devices (CSD) offer a new therapeutic alternative to patients with end-stage refractory heart failure and severe left ventricle (LV) dilatation. Passive mechanical constraint has been shown to reduce LV dilatation as well as to improve LV function and patient symptoms. Using a new echocardiographic technique to evaluate myocardial strain from bidimensional acquisitions, we describe the case of a patient with significant improvement in global and regional LV functions, as well as LV dyssynchrony following CSD implantation.
BACKGROUND: Isolated atrial fibrillation (AF) is associated with mild enlargement of the left atrium (LA) and left ventricular (LV) diastolic dysfunction. The impact of ablation of isolated AF on left chamber size and function is unclear, and whether diastolic dysfunction is the cause or the consequence of AF remains unknown. The objective of this prospective study was to evaluate the impact of sinus rhythm restoration by catheter ablation on LV diastolic dysfunction, LA morphology, and mechanical function. METHODS AND RESULTS: Forty-eight patients with isolated AF were studied by serial echocardiographic studies at baseline and at 1-, 3-, 6-, 9-, and 12-month intervals after radiofrequency ablation. LA dimensions and mechanical function and LV systolic and diastolic functions were evaluated at each time interval. Diastolic function was assessed with conventional Doppler parameters and new indexes such as tissue Doppler imaging, mitral flow propagation velocity, and combined criteria. LV diastolic dysfunction was present in paroxysmal and chronic AF patients with a reduction of tissue Doppler imaging lateral early diastolic peak velocity in 37% (P<0.001) and 48% (P<0.01), respectively, compared with healthy control subjects. At the end of the follow-up, LA area decreased significantly by 18% (P<0.001) in paroxysmal and 23% (P<0.05) in chronic AF patients. Diastolic function improved significantly with an increase in lateral early diastolic peak velocity of 29% (P<0.001) in paroxysmal AF and 46% (P<0.05) in chronic AF patients. A significant increase in LV ejection fraction was also noted for both groups: 7.7% and 18.8%, respectively. CONCLUSIONS: This study demonstrates reverse morphological remodeling of the LA and improvement of LV diastolic and systolic functions after restoration of sinus rhythm by ablation for isolated AF. Because patients with isolated AF have none of the traditional causes of LV diastolic dysfunction, our findings suggest that AF may be partly the cause rather than the consequence of diastolic dysfunction.
Explore the source record for details and available documents.
AIMS: To assess the agreement of left ventricular ejection fraction (LVEF) determinations from unenhanced echocardiography, contrast-enhanced echocardiography, magnetic resonance imaging (MRI), and cineventriculography as well as the inter-observer agreement for each method. METHODS AND RESULTS: In 120 patients, with evenly distributed EF-groups (> 55, 35-55, < 35%), cineventriculography, unenhanced echocardiography with second harmonic imaging, and contrast echocardiography at low mechanical index with iv administration of SonoVue were performed. In addition, cardiac MRI at 1.5 T using a steady-state free precession sequence was performed in a subset of 55 patients. On-site, and two blinded off-site assessments were performed for unenhanced and contrast echocardiography, cineventriculography, and MRI according to pre-defined standards. Intra-class correlation coefficients (ICCs) were determined to assess inter-observer reliability between all three readers (i.e. one on-site and two off-site). EF was 56.2 +/- 18.3% by cineventriculography, 54.1 +/- 12.9% by MRI, 50.9 +/- 15.3% by unenhanced echocardiography, and 54.6 +/- 16.8% by contrast echocardiography. Correlation on EF between cineventriculography and echocardiography increased from 0.72 with unenhanced echocardiography to 0.83 with contrast echocardiography (P < 0.05). Similarly, correlation on EF between MRI and echocardiography increased from 0.60 with unenhanced echocardiography to 0.77 with contrast echocardiography (P < 0.05). The inter-observer reliability ICC was 0.91 (95% CI 0.88-0.94) in contrast echocardiography, followed by cardiac MRI (0.86; 95% CI 0.80-0.92), cineventriculography (0.80; 95% CI 0.74-0.85), and unenhanced echocardiography (0.79; 95% CI 0.74-0.85). CONCLUSIONS: Unenhanced echocardiography resulted in slight underestimation of EF and only moderate correlation compared with cineventriculography and MRI. Contrast echocardiography resulted in more accurate EF and significantly improved correlation with cineventriculography and MRI. Contrast echocardiography significantly improved inter-observer agreement on EF compared with unenhanced echocardiography. Inter-observer reliability on EF using contrast echocardiography reaches a level comparable to MRI and is better than those obtained by cineventriculography.
OBJECTIVES: We sought to evaluate the relationship between hemodynamic and ventricular dyssynchrony parameters in patients undergoing simultaneous and sequential biventricular pacing (BVP). BACKGROUND: Various echocardiographic parameters of ventricular dyssynchrony have been proposed to screen and optimize BVP therapy. METHODS: Forty-one patients with heart failure undergoing BVP implantation were studied. Echocardiography coupled with tissue tracking and pulsed Doppler tissue imaging (DTI) was performed before and after BVP implantation and after three months of optimized BVP. Indexes of inter- or intraventricular dyssynchrony were correlated with hemodynamic changes during simultaneous and sequential BVP (10 intervals of right ventricular [RV] or left ventricular [LV] pre-excitation). RESULTS: Variations in intra-LV delay(peak), intra-LV delay(onset), and index of LV dyssynchrony measured by pulsed DTI were highly correlated with those of cardiac output (r = -0.67, r = -0.64, and r = -0.67, respectively; p < 0.001) and mitral regurgitation (r = 0.68, r = 0.63, and r = 0.68, respectively; p < 0.001), whereas variations in the extent of myocardium displaying delayed longitudinal contraction (r = -0.48 and r = 0.51, respectively; p < 0.05) and the variations in septal-to-posterior wall motion delay (r = -0.41, p < 0.05 and r = 0.24, p = NS, respectively) were less correlated. The changes in interventricular dyssynchrony were not significantly correlated (p = NS). Compared with simultaneous BVP, individually optimized sequential BVP significantly increased cardiac output (p < 0.01), decreased mitral regurgitation (p < 0.05), and improved all parameters of intra-LV dyssynchrony (p < 0.01). At three months, a significant reverse mechanical LV remodeling was observed with significantly decreased LV volumes (p < 0.01) associated with an increased LV ejection fraction (p = 0.035). CONCLUSIONS: Specific echocardiographic measurements of ventricular dyssynchrony are highly correlated with hemodynamic changes and may be a useful adjunct in the selection and optimization of BVP. Individually optimized sequential BVP provided a significant early hemodynamic improvement compared with simultaneous BVP.
BACKGROUND: Although dual-chamber pacing improves cardiac function in patients with complete congenital atrioventricular block (CCAVB) by restoring physiological heart rate and atrioventricular synchronization, the long-term detrimental effect of asynchronous electromechanical activation induced by apical right ventricular pacing (RVP) has not been well clarified. METHODS AND RESULTS: Twenty-three CCAVB adults (24+/-3 years) with a DDD transvenous pacemaker underwent conventional echocardiography before implantation and, after at least 5 years of RVP, an exercise test and echocardiography coupled with tissue Doppler imaging and tissue tracking. They were compared with 30 matched healthy control subjects. After 10+/-3 years of RVP, CCAVB adults had significantly higher values versus controls in terms of intra-left ventricular (LV) asynchrony (respectively, 59+/-18 versus 19+/-9 ms, P<0.001), extent of LV myocardium displaying delayed longitudinal contraction (39+/-15% versus 10+/-7%, P<0.01), and septal-to-posterior wall-motion delay (84+/-26 versus 18+/-9 ms, P<0.01). The ratio of late-activated posterior to early-activated septal wall thickness was higher after long-term RVP than before (1.3+/-0.2 vs 1+/-0.1, P=0.05) and was higher than in controls (1+/-0.1, P<0.05). The percentage of patients with increased LV end-diastolic diameter was higher after long-term RVP than before implantation and was higher than in controls (57% versus 13%, P<0.05, and 57% versus 0%, P<0.01, respectively). CCAVB patients with long-term RVP had a lower cardiac output than controls (3.8+/-0.6 versus 4.9+/-0.8 L/min, P<0.05) and lower exercise performance (123+/-24 versus 185+/-39 W, P<0.001). CONCLUSIONS: Prolonged ventricular dyssynchrony induced by long-term endovenous RVP is associated with deleterious LV remodeling, LV dilatation, LV asymmetrical hypertrophy, and low exercise capacity. These new data highlight the importance of the ventricular activation sequence in all patients with chronic ventricular pacing.
UNLABELLED: We sought to assess right, left and biventricular pacing effects on myocardial function by using pulsed-Doppler tissue imaging (DTI) and automated border detection (ABD) techniques which provide electromechanical delay (EMD) assessment of the different left ventricular walls. METHODS: 15 patients (67+/-7 years) with drug-resistant primitive dilated cardiomyopathy and QRS> or =140 ms received a pacemaker for multisite ventricular pacing. Echocardiography was performed after 1 month of biventricular pacing (BVP). Echocardiographic measurements were recorded during spontaneous rhythm (SpR), right ventricular pacing (RVP), left ventricular pacing (LVP) and BVP. RESULTS: LV ejection fraction was statistically similar between the four rhythms. BVP showed a significant EMD decrease for the lateral LV wall vs. SpR, RVP and even LVP. LVP resulted in significantly longer aortic pre-ejection time vs. BVP while the EMD temporal dispersion (time between the shortest regional EMD and the longest one) was similar in the two modes. CONCLUSIONS: BVP and LVP substantially reduce the EMD temporal dispersion of the four LV walls, but with a longer aortic pre-ejection time for LVP. In RVP, LVP and BVP, the septal LV wall is always activated later than during SpR. BVP and LVP are associated with a mitral regurgitation reduction.
OBJECTIVES: We sought to assess the electromechanical parameters, using tissue Doppler echocardiography, as potential independent predictors of heart failure (HF) worsening. BACKGROUND: Ventricular conduction disorders worsen the prognosis for HF patients. However, the relationships between the QRS width and morphology, hemodynamic parameters, and presence and magnitude of intra-left ventricular (LV) and inter-ventricular (V) asynchrony have not been well clarified. METHOD: A total of 104 patients with an LV ejection fraction (EF) </=45% and stabilized HF, without myocardial infarction (MI), underwent echocardiography coupled with tissue Doppler imaging and were followed for one year. The protocol analyzed the incidence of worsening HF (hospitalization for cardiac decompensation). Inter-V and regional electromechanical delays for the anterior, septal, inferior, and lateral LV walls were correlated with the QRS morphology and duration. The intra-LV and inter-V asynchrony values of these patients were compared with those of healthy subjects matched by gender and age criteria to determine the respective normal ranges. RESULTS: The presence of intra-LV (but not inter-V) asynchrony was identified as an independent predictor of severe cardiac events (hazard ratio 3.39, p < 0.0001), independent of the LVEF and QRS width. Of patients with a QRS width <120 ms (55%; n = 57), 56% presented with major intra-LV asynchrony and 12% with inter-V asynchrony. Intra-LV asynchrony was observed in 84% of left bundle branch block patients, but also in 83% of right bundle branch block patients (p = NS). There was a poor correlation between the QRS width and intra-LV or inter-V asynchrony (r = 0.36, p = NS and r = 0.43, p = 0.05, respectively). CONCLUSIONS: In HF patients without MI, patients with intra-LV asynchrony are those with a significantly higher risk of cardiac events, independent of the QRS width and LVEF. Accordingly, such patients should be more actively identified for early intensive treatment and survey.
OBJECTIVES: We assessed the effect of glycoprotein IIb/IIIa inhibition (GPI) on microvascular flow after coronary occlusion/reperfusion using quantitative myocardial contrast echocardiography (QMCE). BACKGROUND: Platelets may play a major role in the dissociation of epicardial artery recanalization and tissue-level reperfusion, referred to as the "no-reflow phenomenon." Therefore, GPI might improve myocardial reperfusion, distinct from its effects on epicardial patency.T METHOD: hree-hour occlusion of the left anterior descending coronary artery (LAD) was followed by 3-h reperfusion in 16 open-chest dogs: 8 controls and 8 given a continuous infusion of the GPI tirofiban, starting 45 min before LAD reopening. Perfusion of the LAD bed was quantified by the rate of intensity rise (b) by QMCE; myocardial blood flow (MBF) was assessed by fluorescent microspheres. RESULTS: No differences in b or MBF were observed within the risk area between the control and GPI groups at baseline or occlusion. However, b and MBF were higher in GPI dogs than in controls during reperfusion, despite similar epicardial flow (p < 0.05 at 30, 60, and 90 min; p = NS at 180 min). Infarct area size was significantly reduced in GPI dogs compared with non-treated dogs (26.9 +/- 10.5% vs. 49.0 +/- 11.1% of at-risk area, respectively). CONCLUSIONS: As demonstrated by QMCE, GPI improves microvascular flow and reduces the infarct area after coronary occlusion/reperfusion, independent of epicardial flow. These data demonstrate the usefulness of QMCE in assessing microvascular flow, provide novel evidence for the role of platelets in the early phase of reperfusion injury, and show that GPI is of value in preserving microvascular perfusion after coronary reperfusion.