Unusual VDD-pacing.

The case of an 80-year-old woman who underwent permanent VDD-pacemaker implantation for recurrent syncope in the presence of second-degree type 2 AV-block is reported. During follow-up, low atrial sensing with AV-synchrony of only 58-73% was noted. Four years after the pacemaker implantation, the patient was hospitalized for non-cardiac reasons and the chest radiograph showed displacement of the atrial dipole into the right ventricular outflow tract (RVOT). It is hypothesized that AV-synchrony was maintained by left atrial sensing due to the anatomic proximity of the RVOT to the left atrial appendage.

Aged, 80 and over↗

Right atrial pacing impairs cardiac function during resynchronization therapy: acute effects of DDD pacing compared to VDD pacing.

OBJECTIVES: We aimed to compare the hemodynamic effects of right-atrial-paced (DDD) and right-atrial-sensed (VDD) biventricular paced rhythm on cardiac resynchronization therapy (CRT). BACKGROUND: Cardiac resynchronization therapy improves hemodynamics in patients with severe heart failure and left ventricular (LV) dyssynchrony. However, the impact of active right atrial pacing on resynchronization therapy is unknown. METHODS: Seventeen CRT patients were studied 10 months (range: 1 to 46 months) after implantation. At baseline, the programmed atrioventricular delay was optimized by timing LV contraction properly at the end of atrial contraction. In both modes the acute hemodynamic effects were assessed by multiple Doppler echocardiographic parameters. RESULTS: Compared to DDD pacing, VDD pacing resulted in much better improvement of intraventricular dyssynchrony assessed by the septal-to-posterior wall motion delay (VDD 106 +/- 83 ms vs. DDD 145 +/- 95 ms; p = 0.001), whereas the interventricular mechanical delay (difference between onset of pulmonary and aortic outflow) did not differ (VDD 20 +/- 21 ms vs. DDD 18 +/- 17 ms; p = NS). Furthermore, VDD pacing significantly prolonged the rate-corrected LV filling period (VDD 458 +/- 123 ms vs. DDD 371 +/- 94 ms; p = 0.0001) and improved the myocardial performance index (VDD 0.60 +/- 0.18 vs. DDD 0.71 +/- 0.23; p < 0.01). CONCLUSIONS: Our findings suggest that avoidance of right atrial pacing results in a higher degree of LV resynchronization, in a substantial prolongation of the LV filling period, and in an improved myocardial performance. Thus, the VDD mode seems to be superior to the DDD mode in CRT patients.

Atrial Fibrillation↗

Cardiac resynchronization in severe heart failure and left bundle branch block: a single center experience.

OBJECTIVE: To assess the feasibility and longterm outcome of cardiac resynchronization therapy (CRT) in patients with impaired left ventricular function (LVEF <35%), left bundle branch block (QRS >120 ms) and dyspnoea NYHA 0 III at a single centre. METHODS AND RESULTS: Forty-seven patients were referred for implantation of a CRT device. In only 4 patients (9%) the device could not be implanted due to technical problems during the procedure. In the remaining 43 patients (65 +/- 10 years; 7 female) a CRT device was implanted. Follow-up time was 12 +/- 10 months. Twenty-one patients had dilated cardiomyopathy (DCM) and 22 patients had coronary artery disease (CAD). NYHA functional class improved from 3.0 +/- 1.4 to 2.5 +/- 0.7 (p <0.0001), accompanied by an improvement of LVEF [median 20% (range 15-25) vs 32% (range 20-40); p <0.0001]. A significant reduction of hospitalisation time for heart failure was found when the year before and the year after device implantation [18 days (range 5-27) vs 1 day (range 0-3); p <0.0001] were compared. Twelve (28%) patients, 9 with CAD, and 3 with DCM died. Two CAD patients and all patients with DCM who died had a combined CRT device with implantable cardioverter/defibrillator. CONCLUSION: In patients with severely impaired LVEF and wide QRS due to LBBB, CRT is feasible and safe. It improved dyspnoea and LVEF and reduced hospitalisation stays for heart failure during long-term follow-up.

Aged↗