CO2 rebreathing model in COPD: blood-to-gas equilibration.

Rebreathing in a closed system can be used to estimate mixed venous PCO2 (PvCO2) and cardiac output, but these estimates are affected by VA/Q heterogeneity. The purpose of this study was to validate a mathematical model of CO2 exchange during CO2 rebreathing in 29 patients with chronic obstructive pulmonary disease (COPD), with baseline arterial PCO2 (PaCO2) ranging from 28 to 60 mmHg. Rebreathing increased end-tidal PCO2 (PETCO2) by 20 mmHg over 2.2 min. This model employed baseline values for inspired (bag) PCO2, estimated PvCO2, distribution of ventilation and blood flow in one high VA/Q and one low VA/Q compartment, the ventilation increase and conservation of mass equations to simulate time courses of PICO2, PETCO2, PvCO2, and PaCO2. Measured PICO2 and PETCO2 during rebreathing differed by an average (SEM) of 1.4 (0.4) mmHg from simulated values. By end of rebreathing, predicted PvCO2 was lower than measured and predicted PaCO2, indicating gas to blood CO2 flux. Estimates of the ventilatory response to CO2, quantified as the slope (S) of the ventilation increase versus PETCO2, were inversely related to gas-to-blood PCO2 disequilibria due to VA/Q heterogeneity and buffer capacity (BC), but not airflow limitation. S may be corrected for these artifacts to restore S as a more valid noninvasive index of central CO2 responsiveness. We conclude that a rebreathing model incorporating baseline VA/Q heterogeneity and BC can simulate gas and blood PCO2 in patients with COPD, where VA/Q variations are large and variable.

Acid-Base Equilibrium↗

Validation of a two-compartment model of ventilation/perfusion distribution.

Ventilation (V (A)) to perfusion (Q ) heterogeneity (V (A)/Q ) analyses by a two-compartment lung model (2C), utilizing routine gas exchange measurements and a computer solution to account for O(2) and CO(2) measurements, were compared with multiple inert gas elimination technique (MIGET) analyses and a multi-compartment (MC) model. The 2C and MC estimates of V (A)/Q mismatch were obtained in 10 healthy subjects, 43 patients having chronic obstructive pulmonary disease (COPD) and in 14 dog experiments where hemodynamics and acid-base status were manipulated with gas mixtures, fluid loading and tilt-table stressors. MIGET comparisons with 2C were made on 6 patients and 32 measurements in healthy subjects before and after exercise at normoxia and altitude hypoxia. Statistically significant correlations for logarithmic standard deviations of V (A)/Q distributions (SD(V (A)/Q )) were obtained for all 2C comparisons, with similar values between 2C and both other methods in the 1.1-1.5 range, compatible with mild to moderate COPD. 2C tended to overestimate MC and MIGET values at low and underestimate them at high SD(V (A)/Q ) values. SD(V (A)/Q ) weighted by Q agreed better with MC and MIGET estimates in the normal range, whereas SD(V (A)/Q ) weighted by V (A) was closer to MC at higher values because the V (A)-weighted SD(V (A)/Q ) is related to blood-to-gas PCO(2) differences that are elevated in disease, thereby allowing better discrimination. The 2C model accurately described functional V (A)/Q characteristics in 26 normal and bronchoconstricted dogs during non-steady state rebreathing and could be used to quantify the effect of reduced O(2) diffusing capacity in diseased lungs. These comparisons indicate that 2C adequately describes V (A)/Q mismatch and can be useful in clinical or experimental situations where other techniques are not feasible.

Adult↗

Chemically selective NMR imaging of a 3-component (solid-solid-liquid) sedimenting system.

A novel magnetic resonance imaging (MRI) technique which resolves the separate components of the evolving vertical concentration profiles of 3-component non-colloidal suspensions is described. This method exploits the sensitivity of MRI to chemical differences between the three phases to directly image the fluid phase and one of the solid phases, with the third phase obtained by subtraction. 19F spin-echo imaging of a polytetrafluoroethylene (PTFE) oil was interlaced with 1H SPRITE imaging of low-density polyethylene (LDPE) particles. The third phase was comprised of borosilicate glass spheres, which were not visible while imaging the PTFE or LDPE phases. The method is demonstrated by performing measurements on 2-phase materials containing only the floating (LDPE) particles, with the results contrasted to the experimental behaviour of the individual phases in the full 3-phase system. All experiments were performed using nearly monodisperse particles, with initial suspension volume fractions, phi(i), of 0.1.