Optical mapping of V(m) and Ca(i)(2+) in a model of arrhythmias induced by local catecholamine application in patterned cell cultures.

Catecholamines are known to provoke cardiac arrhythmias, but important aspects such as localization of the arrhythmia source in multicellular tissue and exact ionic mechanisms are not well-known. In this work, a multicellular model of arrhythmias caused by local epinephrine application was developed; V (m) and Ca(i)(2+) changes at the arrhythmia source were measured using fluorescent dyes and high-resolution optical mapping. Cultured strands of neonatal rat myocytes (width approximately 0.4 mm) were produced by patterned growth. Epinephrine (1 micromol/l) was applied over an area of 0.3-0.6 mm via two micropipettes, and strands were stimulated by burst pacing. Local epinephrine application caused triggered arrhythmias with cycle lengths of 202-379 ms and duration of >10 s in 9 out of 16 preparations. Optical V(m) mapping demonstrated that in 78% of cases, the source of arrhythmia was located at the boundary of the locally perfused area. Staining with Ca(i)(2+)-sensitive dye Fluo-4 prevented arrhythmia induction in most cases (85%) likely due to Ca(2+) buffering by the dye. Optical Ca(i)(2+) mapping revealed non-propagated Ca(i)(2+) oscillations at the boundary of the locally perfused area in 45% cases. In conclusion, we developed a new model of catecholamine-dependent arrhythmias allowing mapping of V(m) and Ca(i)(2+) at the arrhythmia source with microscopic resolution. The arrhythmias typically originated from the boundary of the epinephrine-perfused area. The location of the arrhythmia source correlated with localized Ca(i)(2+) oscillations suggesting that arrhythmias were caused by Ca(i)(2+) overload at these locations.

Aniline Compounds↗

Imaging of cardiac movement using ratiometric and nonratiometric optical mapping: effects of ischemia and 2, 3-butaneodione monoxime.

Transmembrane voltage-sensitive fluorescent dyes are used to study electrical activity in hearts. Green and red fluorescence emissions from di-4-ANEPPS excited with 488 nm light indicate both transmembrane voltage changes and heart movement. We have previously shown that the ratio, green fluorescence divided by red fluorescence, indicates the transmembrane voltage without effects of movement. Here we examine the feasibility of measuring the movement, which is useful for the study of cardiac function, by subtracting this ratiometric signal from the red or green fluorescence signal. The results of this subtraction show tissue movement and its relative changes during cardiac ischemia and perfusion with an electromechanical uncoupling agent. By incorporating the spatial variations in fluorescence intensity from the heart, tissue movement can be qualitatively mapped to examine relative changes, however, with limited ability to quantify absolute displacement. Since these maps are obtained simultaneously with corresponding transmembrane potentials, the method allows study of spatiotemporal cardiac movement patterns and their relationship to the action potential.

Algorithms↗

Use of translucent indium tin oxide to measure stimulatory effects of a passive conductor during field stimulation of rabbit hearts.

Biomathematical models and experiments have indicated that passive extracellular conductors influence field stimulation. Because metallic conductors prevent optical mapping under the conductor, we have evaluated a passive translucent indium tin oxide (ITO) thin-film conductor to allow mapping of transmembrane potential (V(m)) and stimulatory current under the conductor. A 1-cm ITO disk was patterned photolithographically and positioned between 0.3-cm(2) mesh shock electrodes on the ventricular epicardium of isolated perfused rabbit hearts stained with 4-{2-[6-(dibutylamino)-2-naphthylenal]ethenyl}-1-(3-sulfopropyl)-, hydroxide, inner salt (di-4-ANEPPS). For a 1-A, 10-ms shock during the action potential plateau, optical maps from fluorescence collected using emission ratiometry (excitation at 488 nm and emissions at 510-570 and >590 nm) indicated that the disk altered V(m) by as much as the height of an action potential. DeltaV(m) became more positive near the edge of the disk, where the ITO conductance gradient was parallel to applied current, and more negative near the opposite edge, where the gradient was not parallel to current. For diastolic shocks, the disk expedited membrane excitation at the sites of positive DeltaV(m) in the heart and in a cardiac model with realistic ITO disk surface and interfacial conductances. Optical maps of ITO transmittance and the model indicated that the disk introduced anodal and cathodal stimulatory current at opposite edges of the disk. Thus ITO allows study of the stimulatory effects of a passive conductor in an electric field.

Animals↗

Two-photon excitation of di-4-ANEPPS for optical recording of action potentials in rabbit heart.

Cardiac action potentials have been measured with single-photon excitation (SPE) of transmembrane voltage-sensitive fluorescent dye. Two-photon excitation (TPE) may have advantages for localization and depth of the tissue region from which the action potential is measured. However measurements of action potentials with SPE have not been demonstrated. We sought to develop a method for TPE of di-4-ANEPPS and test whether the method yields voltage-dependent fluorescence in cardiac tissue. We modified our SPE and ratio-metric fluorescence recording system to use a femtosecond pulsed near-infrared laser. Modifications were made to enhance fluorescence collection efficiency and to block infrared laser light from entering the fluorescence collection system. Fluorescence was collected simultaneously in green (510-570 nm) and red (590-700 nm) wavelength bands. Action potentials were observed in the ratio of the green signal to the red signal, but were not observed above the noise level in either of the individual signals. Incorporation of a common-mode noise subtraction method revealed action potentials in green and red signals. We also found that the di-4-ANEPPS fluorescence emission spectrum for TPE at 930 nm was similar to the emission spectrum for SPE at 488 nm. The multiphoton method may be beneficial for highly localized cardiac optical measurements.

Action Potentials↗

Cardiac optical mapping under a translucent stimulation electrode.

Major effects of stimulation on cardiac transmembrane potentials (Vm) are thought to occur under the electrode, however these have not been optically mapped due to blockage of light by electrodes. Here we optically mapped under translucent indium tin oxide (ITO) electrodes in hearts stained with transmembrane voltage sensitive fluorescent dye, di-4-ANEPPS excited at 488 nm. Emissions in wavelength bands 510-570 nm and >590 nm were similarly affected by changes in ITO transmittance due to electrochemical effects of current at the electrode interface. Dual-wavelength ratiometric mapping with the two emission bands revealed Vm under the electrode during plateau-phase stimulation (220 mA). Changes in Vm were heterogeneous under the electrode, and were anisotropic with larger values along the fiber axis. These results explain early excitation sites for sufficiently strong diastolic stimulation, and agree with theoretical predictions based on summation of anisotropic effects of point stimulation and a linear 3-d cardiac bidomain computer model. The bidomain model and experiments disagree under the edge of the electrode, where modeled Vm is much larger. Thus, changes in Vm under an electrode are anisotropic with greater Vm in the direction parallel to fibers. Nonlinear effects of stimulation in hearts may limit changes in Vm under the electrode edge.

Animals↗

Emission ratiometry for simultaneous calcium and action potential measurements with coloaded dyes in rabbit hearts: reduction of motion and drift.

INTRODUCTION: Optical measurements of the cardiac calcium transient (Ca) and transmembrane action potential (AP) may be performed simultaneously with emission ratiometry to lessen motion artifacts and photobleaching effects. We examined changes in emission spectrum in perfused rabbit hearts coloaded with Rh237 and a green-emitting Ca dye (Fluo-4 or Oregon Green BAPTA 1) to determine wavelength bands for emission ratiometry and to test whether ratiometry reduces motion artifacts and drift. METHODS AND RESULTS: A 488-nm laser illuminated hearts while a spectrofluorometer collected fluorescence from 489 to 838 nm at 1 kHz. Ratiometry with the Ca- and AP-insensitive emission band 663 to 685 nm (IS) as denominator and the Ca-sensitive band 510 to 532 nm as numerator lessened motion artifacts, which was quantified as a 1.4-fold increase in relative amplitude of the Ca (P < 0.05). Ratiometry with the AP-sensitive band 772 to 794 nm as denominator and the IS as numerator produced a 1.7-fold increase in relative amplitude of the AP (P < 0.05). The ratiometry decreased photobleaching-dependent drift by a factor of 0.6 (P < 0.05) for Ca and 0.45 (P < 0.05) for AP. CONCLUSION: Simultaneous Ca and AP emission ratiometry reduces motion artifacts and drift in hearts with coloaded dyes.

Action Potentials↗

Simultaneous electrical and optical mapping in rabbit hearts.

Local cardiac excitation is measured from either extracellular voltage (Ve) or optical transmembrane voltage (Vm) with fluorescent dye. We used a transparent electrode array and a laser scanner to test whether Ve and coepicentral optical Vm give equivalent excitation times during epicardial pacing and sinus beats. To help explain time differences, we estimated interrogation width/depth ratios for Ve and optical Vm with dipole and Monte Carlo models. Magnitudes of time differences between excitation measured with Ve and optical Vm during pacing were 1.9 +/- 1.9 ms (n= 1,112 recording pairs). Deeper interrogation for optical Vm vs Ve was indicated with sinus beats that contained a transmural propagation component. When pacing produced propagation along epicardial fibers, excitation time measured from optical Vm was later than excitation time measured with epicardial Ve. When pacing produced propagation across epicardial fibers, excitation time measured from optical Vm was earlier than that measured with epicardial Ve. These time differences could be attributed to deeper optical interrogation and fiber rotation with depth in ventricles.

Action Potentials↗

Spatial localization of cardiac optical mapping with multiphoton excitation.

Depth and radius of regions interrogated by cardiac optical mapping with a laser beam depend on photon travel inside the heart. It would be useful to limit the range of depth and radius interrogated. We modeled the effects of a condensing lens to concentrate laser light at a target depth inside the heart, and near infrared excitation to increase penetration and produce two-photon absorption. A Monte Carlo simulation that incorporated a 0.55-NA lens, and absorption and scattering of 1064- or 488-nm laser light in 3-D cardiac tissue indicated the distribution of excitation fluence inside the tissue. A subsequent simulation incorporating absorption and scattering of transmembrane voltage-sensitive fluorescence (wavelength 669 nm) indicated locations from which fluorescence photons exiting the tissue surface originated. The results indicate that mapping at depths up to 300 microm in hearts can provide significant improvement in localization over existing cardiac optical mapping. The estimated interrogation region is sufficiently small to examine cardiac events at a cellular or subcellular scale and may allow mapping at various depths in the heart.

Action Potentials↗

Modulation of triggered activity by uncoupling in the ischemic border. A model study with phase 1b-like conditions.

OBJECTIVE: Triggered beats during regional ischemia may depend upon the electrical source and sink charge interactions between adjacent regions of normal and ischemic cardiac tissue that are partly controlled by electrical coupling. METHODS: To study these relationships, we modified parameters in the Luo-Rudy dynamic membrane equations to reflect physiologic conditions associated with phase 1b arrhythmias. Superthreshold delayed afterdepolarizations (DADs) formed after pacing. Coupling contributions were then examined using: (i) a single phase 1b myocyte connected via a variable resistance to a single normal myocyte, and (ii) a multicellular fiber with a 1-cm segment of phase 1b myocytes connected to a 1-cm normal segment having resistance changes that were confined to the ischemic segment. Integration of ionic, capacitive and coupling currents during DAD initiation allowed charge quantification. RESULTS: In cell pairs, phase 1b myocyte DADs were suppressed at resistances where normal myocyte pacing resulted in phase 1b myocyte excitation. Coupling charge requirements limited capacitive charging in the phase 1b myocyte, which occurred in combination with diastolic hyperpolarization that shifted transmembrane potential from threshold. In multicellular fiber simulations, DADs were suppressed with strong coupling in the phase 1b segment. Moderate uncoupling of that segment allowed superthreshold DAD formation away from the border that initiated action potential propagation in the normal segment. With severe uncoupling, propagation failed at the border. CONCLUSIONS: These findings support the clinical and experimental observation that intermediate uncoupling is an important contributor to phase 1b arrhythmogenesis.

Calcium↗

Intelligent multichannel stimulator for the study of cardiac arrhythmias.

An intelligent multichannel stimulator (IMS) has been designed and built for use in a cardiac research environment. The device is capable of measuring and responding to cardiac electrophysiological phenomena in real time with carefully timed and placed electrical stimuli. The system consists of 16 channels of sense/stimulation electronics controlled by a digital signal processor (DSP) data acquisition card and a host computer and can be expanded to include more channels. The DSP allows for powerful and flexible algorithms to be implemented for real-time interaction with the cardiac tissue. Although a number of possible uses can be conceived for such a device, the initial motivation was to improve upon attempts to terminate fibrillation by pacing. The IMS was tested in an open-chest animal model, both in sinus rhythm and during fibrillation. It was shown to be an effective research tool by demonstrating the ability to measure and respond to cardiac activations in real time using complex numerical algorithms and appropriately timed stimuli.

Algorithms↗

Use of light absorbers to alter optical interrogation with epi-illumination and transillumination in three-dimensional cardiac models.

Cardiac optical mapping currently provides 2-D maps of transmembrane voltage-sensitive fluorescence localized near the tissue surface. Methods for interrogation at different depths are required for studies of arrhythmias and the effects of defibrillation shocks in 3-D cardiac tissue. We model the effects of coloading with a dye that absorbs excitation or fluorescence light on the radius and depth of the interrogated region with specific illumination and collection techniques. Results indicate radii and depths of interrogation are larger for transillumination versus epi-illumination, an effect that is more pronounced for broad-field excitation versus laser scanner. Coloading with a fluorescence absorber lessens interrogated depth for epi-illumination and increases it for transillumination, which is confirmed with measurements using transillumination of heart tissue slices. Coloading with an absorber of excitation light consistently decreases the interrogated depths. Transillumination and coloading also decrease the intensities of collected fluorescence. Thus, localization can be modified with wavelength-specific absorbers at the expense of a reduction in fluorescence intensity.