PubMed Health⌕ Search

Biomedical subjects

Stephen C Harris

Publications and source records attributed to Stephen C Harris.

5 recordsLinked to original sources

Aminotransferase elevations in healthy adults receiving 4 grams of acetaminophen daily: a randomized controlled trial.

CONTEXT: During a clinical trial of a novel hydrocodone/acetaminophen combination, a high incidence of serum alanine aminotransferase (ALT) elevations was observed. OBJECTIVE: To characterize the incidence and magnitude of ALT elevations in healthy participants receiving 4 g of acetaminophen daily, either alone or in combination with selected opioids, as compared with participants treated with placebo. DESIGN, SETTING, AND PARTICIPANTS: A randomized, single-blind, placebo-controlled, 5-treatment, parallel-group, inpatient, diet-controlled (meals provided), longitudinal study of 145 healthy adults in 2 US inpatient clinical pharmacology units. INTERVENTION: Each participant received either placebo (n = 39), 1 of 3 acetaminophen/opioid combinations (n = 80), or acetaminophen alone (n = 26). Each active treatment included 4 g of acetaminophen daily, the maximum recommended daily dosage. The intended treatment duration was 14 days. Main Outcomes Serum liver chemistries and trough acetaminophen concentrations measured daily through 8 days, and at 1- or 2-day intervals thereafter. RESULTS: None of the 39 participants assigned to placebo had a maximum ALT of more than 3 times the upper limit of normal. In contrast, the incidence of maximum ALT of more than 3 times the upper limits of normal was 31% to 44% in the 4 treatment groups receiving acetaminophen, including those participants treated with acetaminophen alone. Compared with placebo, treatment with acetaminophen was associated with a markedly higher median maximum ALT (ratio of medians, 2.78; 95% confidence interval, 1.47-4.09; P<.001). Trough acetaminophen concentrations did not exceed therapeutic limits in any participant and, after active treatment was discontinued, often decreased to undetectable levels before ALT elevations resolved. CONCLUSIONS: Initiation of recurrent daily intake of 4 g of acetaminophen in healthy adults is associated with ALT elevations and concomitant treatment with opioids does not seem to increase this effect. History of acetaminophen ingestion should be considered in the differential diagnosis of serum aminotransferase elevations, even in the absence of measurable serum acetaminophen concentrations.

Acetaminophen↗

Rat toxicogenomic study reveals analytical consistency across microarray platforms.

To validate and extend the findings of the MicroArray Quality Control (MAQC) project, a biologically relevant toxicogenomics data set was generated using 36 RNA samples from rats treated with three chemicals (aristolochic acid, riddelliine and comfrey) and each sample was hybridized to four microarray platforms. The MAQC project assessed concordance in intersite and cross-platform comparisons and the impact of gene selection methods on the reproducibility of profiling data in terms of differentially expressed genes using distinct reference RNA samples. The real-world toxicogenomic data set reported here showed high concordance in intersite and cross-platform comparisons. Further, gene lists generated by fold-change ranking were more reproducible than those obtained by t-test P value or Significance Analysis of Microarrays. Finally, gene lists generated by fold-change ranking with a nonstringent P-value cutoff showed increased consistency in Gene Ontology terms and pathways, and hence the biological impact of chemical exposure could be reliably deduced from all platforms analyzed.

Animals↗

The MicroArray Quality Control (MAQC) project shows inter- and intraplatform reproducibility of gene expression measurements.

Over the last decade, the introduction of microarray technology has had a profound impact on gene expression research. The publication of studies with dissimilar or altogether contradictory results, obtained using different microarray platforms to analyze identical RNA samples, has raised concerns about the reliability of this technology. The MicroArray Quality Control (MAQC) project was initiated to address these concerns, as well as other performance and data analysis issues. Expression data on four titration pools from two distinct reference RNA samples were generated at multiple test sites using a variety of microarray-based and alternative technology platforms. Here we describe the experimental design and probe mapping efforts behind the MAQC project. We show intraplatform consistency across test sites as well as a high level of interplatform concordance in terms of genes identified as differentially expressed. This study provides a resource that represents an important first step toward establishing a framework for the use of microarrays in clinical and regulatory settings.

Equipment Design↗

Microarray scanner calibration curves: characteristics and implications.

BACKGROUND: Microarray-based measurement of mRNA abundance assumes a linear relationship between the fluorescence intensity and the dye concentration. In reality, however, the calibration curve can be nonlinear. RESULTS: By scanning a microarray scanner calibration slide containing known concentrations of fluorescent dyes under 18 PMT gains, we were able to evaluate the differences in calibration characteristics of Cy5 and Cy3. First, the calibration curve for the same dye under the same PMT gain is nonlinear at both the high and low intensity ends. Second, the degree of nonlinearity of the calibration curve depends on the PMT gain. Third, the two PMTs (for Cy5 and Cy3) behave differently even under the same gain. Fourth, the background intensity for the Cy3 channel is higher than that for the Cy5 channel. The impact of such characteristics on the accuracy and reproducibility of measured mRNA abundance and the calculated ratios was demonstrated. Combined with simulation results, we provided explanations to the existence of ratio underestimation, intensity-dependence of ratio bias, and anti-correlation of ratios in dye-swap replicates. We further demonstrated that although Lowess normalization effectively eliminates the intensity-dependence of ratio bias, the systematic deviation from true ratios largely remained. A method of calculating ratios based on concentrations estimated from the calibration curves was proposed for correcting ratio bias. CONCLUSION: It is preferable to scan microarray slides at fixed, optimal gain settings under which the linearity between concentration and intensity is maximized. Although normalization methods improve reproducibility of microarray measurements, they appear less effective in improving accuracy.

Calibration↗

The pharmacokinetics and safety of single escalating oral doses of eletriptan.

The pharmacokinetics, safety, and tolerability of the 5-HT(1B/1D) agonist eletriptan were characterized in a randomized, double-blind, placebo-controlled, dose escalation study. Healthy males received single oral doses of 10 to 120 mg. Following screening and baseline measurements, plasma and saliva eletriptan concentrations were measured at intervals over 48 hours and 24 hours, respectively. Samples were analyzed using high-performance liquid chromatography with ultraviolet detection. Both the maximum plasma concentration and the area under the plasma eletriptan concentration-time curve showed an essentially linear relationship to the administered dose. Eletriptan exhibited a median time to maximum plasma concentration of 1 to 1.25 hours and a mean elimination half-life of 3.6 to 7.0 hours. Mean salivary-plasma ratios for pharmacokinetic parameters generally remained constant across the 30 to 90 mg dose range. Eletriptan was well tolerated, with mostly mild and transient adverse events. In conclusion, oral doses of eletriptan in the therapeutic range were rapidly absorbed and exhibited essentially linear plasma and saliva pharmacokinetics.

Administration, Oral↗