PubMed Health⌕ Search

Biomedical subjects

Stephen D Davis

Publications and source records attributed to Stephen D Davis.

4 recordsLinked to original sources

Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source.

A new x-ray source, the model S700 Axxent X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, < 1 mm, use of the one-dimensional (1D) brachytherapy dosimetry formalism is not recommended due to polar anisotropy. Consequently, 1D brachytherapy dosimetry parameters were not sought. Calculated point-source model radial dose functions at gP(5) were 0.20, 0.24, and 0.29 for the 40, 45, and 50 kV voltage settings, respectively. For 1<r<7 cm, measured point-source model radial dose functions were typically within 4% of calculated results. Calculated values for F(r, theta) for all operating voltages were within 15% of unity along the distal end (theta=0 degree), and ranged from F(1 cm, 160 degrees) = 0.2 to F(15 cm, 175 degrees) = 0.4 towards the catheter proximal end. For all three operating voltages using the PTW chamber, measured dependence of output as a function of azimuthal angle, psi, was typically on average +/-3% for 0 degree < or = psi < or = 360 degrees. Excluding an energy response function, measurements of normalized photon energy spectra were made for three operating voltages, and were typically within 2% agreement with the normalized Monte Carlo calculated spectra. In general, the model S700 Source exhibited depth dose behavior similar to low-energy photon-emitting low dose rate sources 125I and l03Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages.

Brachytherapy↗

Do xylem fibers affect vessel cavitation resistance?

Possible mechanical and hydraulic costs to increased cavitation resistance were examined among six co-occurring species of chaparral shrubs in southern California. We measured cavitation resistance (xylem pressure at 50% loss of hydraulic conductivity), seasonal low pressure potential (P(min)), xylem conductive efficiency (specific conductivity), mechanical strength of stems (modulus of elasticity and modulus of rupture), and xylem density. At the cellular level, we measured vessel and fiber wall thickness and lumen diameter, transverse fiber wall and total lumen area, and estimated vessel implosion resistance using (t/b)(h)(2), where t is the thickness of adjoining vessel walls and b is the vessel lumen diameter. Increased cavitation resistance was correlated with increased mechanical strength (r(2) = 0.74 and 0.76 for modulus of elasticity and modulus of rupture, respectively), xylem density (r(2) = 0.88), and P(min) (r(2) = 0.96). In contrast, cavitation resistance and P(min) were not correlated with decreased specific conductivity, suggesting no tradeoff between these traits. At the cellular level, increased cavitation resistance was correlated with increased (t/b)(h)(2) (r(2) = 0.95), increased transverse fiber wall area (r(2) = 0.89), and decreased fiber lumen area (r(2) = 0.76). To our knowledge, the correlation between cavitation resistance and fiber wall area has not been shown previously and suggests a mechanical role for fibers in cavitation resistance. Fiber efficacy in prevention of vessel implosion, defined as inward bending or collapse of vessels, is discussed.

Biomechanical Phenomena↗

The limits to tree height.

Trees grow tall where resources are abundant, stresses are minor, and competition for light places a premium on height growth. The height to which trees can grow and the biophysical determinants of maximum height are poorly understood. Some models predict heights of up to 120 m in the absence of mechanical damage, but there are historical accounts of taller trees. Current hypotheses of height limitation focus on increasing water transport constraints in taller trees and the resulting reductions in leaf photosynthesis. We studied redwoods (Sequoia sempervirens), including the tallest known tree on Earth (112.7 m), in wet temperate forests of northern California. Our regression analyses of height gradients in leaf functional characteristics estimate a maximum tree height of 122-130 m barring mechanical damage, similar to the tallest recorded trees of the past. As trees grow taller, increasing leaf water stress due to gravity and path length resistance may ultimately limit leaf expansion and photosynthesis for further height growth, even with ample soil moisture.

Biological Transport↗

Freeze/thaw stress in Ceanothus of southern California chaparral.

Freeze/thaw stress was examined in chaparral shrubs of the genus Ceanothus to determine the interactive effects of freezing and drought and to consider which is the more vulnerable component, the living leaves (symplast) or the non-living water transport system (apoplast). We hypothesized that where Ceanothus species co-occurred, the more inland species C. crassifolius would be more tolerant of low temperatures than the coastal species C. spinosus, both in terms of leaf survival (LT(50), or the temperature at which there is 50% loss of function or viability) and in terms of resistance to freezing-induced embolism (measurements of percent loss hydraulic conductivity due to embolism following freeze/thaw). Cooling experiments on 2 m long winter-acclimated shoots resulted in LT(50) values of about -10 degrees C for C. spinosus versus -18 degrees C for C. crassifolius. Freeze-thaw cycles resulted in no change in embolism when the plants were well hydrated (-0.7 to -2.0 MPa). However, when plants were dehydrated to -5.0 MPa, C. spinosus became 96% embolized with freeze/thaw, versus only 61% embolism for C. crassifolius. Stems of C. crassifolius became 90% and 97% embolized at -6.6 and -8.0 MPa, respectively, meaning that even in this species, stems could be more vulnerable than leaves under conditions of extreme water stress combined with freeze/thaw events. The dominance of C. crassifolius at colder sites and the restriction of C. spinosus to warmer sites are consistent with both the relative tolerance of their symplasts to low temperatures and the relative tolerance of their apoplasts to freeze events in combination with drought stress.

Adaptation, Physiological↗