Establishment of a novel intervertebral disc/endplate culture model: analysis of an ex vivo in vitro whole-organ rabbit culture system.

STUDY DESIGN: Ex vivo in vitro study evaluating a novel intervertebral disc/endplate culture system. OBJECTIVES: To establish a whole-organ intervertebral disc culture model for the study of disc degeneration in vitro, including the characterization of basic cell and organ function. SUMMARY OF BACKGROUND DATA: With current in vivo models for the study of disc and endplate degeneration, it remains difficult to investigate the complex disc metabolism and signaling cascades. In contrast, more controlled but simplified in vitro systems using isolated cells or disc fragments are difficult to culture due to the unconstrained conditions, with often-observed cell death or cell dedifferentiation. Therefore, there is a demand for a controlled culture model with preserved cell function that offers the possibility to investigate disc and endplate pathologies in a structurally intact organ. METHODS: Naturally constrained intervertebral disc/endplate units from rabbits were cultured in multi-well plates. Cell viability, metabolic activity, matrix composition, and matrix gene expression profile were monitored using the Live/Dead cell viability test (Invitrogen, Basel, Switzerland), tetrazolium salt reduction (WST-8), proteoglycan and deoxyribonucleic acid quantification assays, and quantitative polymerase chain reaction. RESULTS: Viability and organ integrity were preserved for at least 4 weeks, while proteoglycan and deoxyribonucleic acid content decreased slightly, and matrix genes exhibited a degenerative profile with up-regulation of type I collagen and suppression of collagen type II and aggrecan genes. Additionally, cell metabolic activity was reduced to one third of the initial value. CONCLUSIONS: Naturally constrained intervertebral rabbit discs could be cultured for several weeks without losing cell viability. Structural integrity and matrix composition were retained. However, the organ responded to the artificial environment with a degenerative gene expression pattern and decreased metabolic rate. Therefore, the described system serves as a promising in vitro model to study disc degeneration in a whole organ.

Animals↗

Minimizing errors during in vitro testing of multisegmental spine specimens: considerations for component selection and kinematic measurement.

Apparatus-induced artifacts may invalidate standard spine testing protocols. Kinematic measurements may be compromised by the configuration of motion capture equipment. This study has determined: (1) the influence of machine design (component friction) on in vitro spinal kinetics; (2) the sensitivity of kinematic measurements to variations in the placement of motion capture markers. A spinal loading simulator has been developed to dynamically apply pure bending moments (three axes) with or without a simultaneous compressive preload. Two linear slider types with different friction coefficients, one with caged ball bearings and one with high-precision roller bearings on rails, were mounted and specimen response compared in sequential tests. Three different optoelectronic marker cluster configurations were mounted on the specimen and motion data was captured simultaneously from all clusters during testing. A polymer tube with a uniform bending stiffness approximately equivalent to a polysegmental lumbar spine specimen was selected to allow reproducible behavior over multiple tests. The selection of sliders for linear degrees of freedom had a marked influence on parasitic shear forces. Higher shear forces were recorded with the caged-bearing design than with the high-precision rollers and consequently a higher moment was required to achieve a given rotation. Kinematic accuracy varied with each marker configuration, but in general higher accuracy was achieved with larger marker spacings and situations where markers moved predominantly parallel to the camera's imaging plane. Relatively common alternatives in the mechanical components used in an apparatus for in vitro spine testing can have a significant influence on the measured kinematic and kinetics. Low-magnitude parasitic shear forces due to friction in sliders induces a linearly increasing moment along the length of the specimen, precluding the ideal of pure moment application. This effect is compounded in polysegmental specimens. Kinematic measurements are highly sensitive to marker design and placement, despite equivalent absolute precision of individual marker measurements, however marker configurations can be designed to minimize errors related to spatial distribution and system bias.

Artifacts↗

Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies.

STUDY DESIGN: Systematic literature review. OBJECTIVE: To evaluate the safety and efficacy of vertebroplasty and kyphoplasty using the data presented in published clinical studies, with respect to patient pain relief, restoration of mobility and vertebral body height, complication rate, and incidence of new adjacent vertebral fractures. SUMMARY OF BACKGROUND DATA: Vertebroplasty and kyphoplasty have been gaining popularity for treating vertebral fractures. Current reviews provide an overview of the procedures but are not comprehensive and tend to rely heavily on personal experience. This article aimed to compile all available data and evaluate the clinical outcome of the 2 procedures. METHODS: This is a systematic review of all the available data presented in peer-reviewed published clinical trials. The methodological quality of included studies was evaluated, and data were collected targeting specific standard measurements. Where possible, a quantitative aggregation of the data was performed. RESULTS: A large proportion of subjects had some pain relief, including 87% with vertebroplasty and 92% with kyphoplasty. Vertebral height restoration was possible using kyphoplasty (average 6.6 degrees ) and for a subset of patients using vertebroplasty (average 6.6 degrees ). Cement leaks occurred for 41% and 9% of treated vertebrae for vertebroplasty and kyphoplasty, respectively. New fractures of adjacent vertebrae occurred for both procedures at rates that are higher than the general osteoporotic population but approximately equivalent to the general osteoporotic population that had a previous vertebral fracture. CONCLUSIONS: The problem with stating definitely that vertebroplasty and kyphoplasty are safe and effective procedures is the lack of comparative, blinded, randomized clinical trials. Standardized evaluative methods should be adopted.

Humans↗

Enhancing the mechanical integrity of the implant-bone interface with BoneWelding technology: determination of quasi-static interfacial strength and fatigue resistance.

The BoneWelding technology is an innovative bonding method, which offers new alternatives in the treatment of fractures and other degenerative disorders of the musculoskeletal system. The BoneWelding process employs ultrasonic energy to liquefy a polymeric interface between orthopaedic implants and the host bone. Polymer penetrates the pores of the surrounding bone and, following a rapid solidification, forms a strong and uniform bond between implant and bone. Biomechanical testing was performed to determine the quasi-static push-out strength and fatigue performance of 3.5-mm-diameter polymeric dowels bonded to a bone surrogate material (Sawbones solid and cellular polyurethane foam) using the BoneWelding process. Fatigue tests were conducted over 100,000 cycles of 20-100 N loading. Mechanical test results were compared with those obtained with a comparably-sized, commercial metallic fracture fixation screw. Tests in surrogate bone material of varying density demonstrated significantly superior mechanical performance of the bonded dowels in comparison to conventional bone screws (p < 0.01), with holding strengths approaching 700 N. Even in extremely porous host material, the performance of the bonded dowels was equivalent to that of the bone screws. For both cellular and solid bone analog materials, failure always occurred within the bone analog material surrounding and distant to the implant; the infiltrated interface was stronger than the surrounding bone analog material. No significant decrease in interfacial strength was observed following conditioning in a physiological saline solution for a period of 1 month prior to testing. Ultrasonically inserted implants migrated, on average, less than 20 microm over, and interfacial stiffness remained constant the full duration of fatigue testing. With further refinement, the BoneWelding technology may offer a quicker, simpler, and more effective method for achieving strong fixation and primary stability for fracture fixation or other orthopaedic and dental implant applications.

Biocompatible Materials↗

Influence of diurnal hyperosmotic loading on the metabolism and matrix gene expression of a whole-organ intervertebral disc model.

It is generally agreed that the mechanical environment of intervertebral disc cells plays an important role in maintaining a balanced matrix metabolism. The precise mechanism by which the signals are transduced into the cells is poorly understood. Osmotic changes in the extracellular matrix (ECM) are thought to be involved. Current in-vitro studies on this topic are mostly short-term and show conflicting data on the reaction of disc cells subjected to osmotic changes which is partially due to the heterogenous and often substantially-reduced culture systems. The aim of the study was therefore to investigate the effects of cyclic osmotic loading for 4 weeks on metabolism and matrix gene expression in a full-organ intervertebral disc culture system. Intervertebral disc/endplate units were isolated from New Zealand White Rabbits and cultured either in iso-osmotic media (335 mosmol/kg) or were diurnally exposed for 8 hours to hyper-osmotic conditions (485 mosmol/kg). Cell viability, metabolic activity, matrix composition and matrix gene expression profile (collagen types I/II and aggrecan) were monitored using Live/Dead cell viability assay, tetrazolium reduction test (WST 8), proteoglycan and DNA quantification assays and quantitative PCR. The results show that diurnal osmotic stimulation did not have significant effects on proteoglycan content, cellularity and disc cell viability after 28 days in culture. However, hyperosmolarity caused increased cell death in the early culture phase and counteracted up-regulation of type I collagen gene expression in nucleus and annulus cells. Moreover, the initially decreased cellular dehydrogenase activity recovered with osmotic stimulation after 4 weeks and aggrecan gene down-regulation was delayed, although the latter was not significant according to our statistical criteria. In contrast, collagen type II did not respond to the osmotic changes and was down-regulated in both groups. In conclusion, diurnal hyper-osmotic stimulation of a whole-organ disc/endplate culture partially inhibits a matrix gene expression profile as encountered in degenerative disc disease and counteracts cellular metabolic hypo-activity.

Aggrecans↗

Effects of anatomic conformation on three-dimensional motion of the caudal lumbar and lumbosacral portions of the vertebral column of dogs.

OBJECTIVE: To determine the association between the 3-dimensional (3-D) motion pattern of the caudal lumbar and lumbosacral portions of the canine vertebral column and the morphology of vertebrae, facet joints, and intervertebral disks. SAMPLE POPULATION: Vertebral columns of 9 German Shepherd Dogs and 16 dogs of other breeds with similar body weights and body conditions. PROCEDURE: Different morphometric parameters of the vertebral column were assessed by computed tomography (CT) and magnetic resonance imaging. Anatomic conformation and the 3-D motion pattern were compared, and correlation coefficients were calculated. RESULTS: Total range of motion for flexion and extension was mainly associated with the facet joint angle, the facet joint angle difference between levels of the vertebral column in the transverse plane on CT images, disk height, and lever arm length. CONCLUSIONS AND CLINICAL RELEVANCE: Motion is a complex process that is influenced by the entire 3-D conformation of the lumbar portion of the vertebral column. In vivo dynamic measurements of the 3-D motion pattern of the lumbar and lumbosacral portions of the vertebral column will be necessary to further assess biomechanics that could lead to disk degeneration in dogs.

Animals↗

The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: experimental and finite-element analysis.

Polyetheretherketone (PEEK) is a novel polymer with potential advantages for its use in demanding orthopaedic applications (e.g. intervertebral cages). However, the influence of a physiological environment on the mechanical stability of PEEK has not been reported. Furthermore, the suitability of the polymer for use in highly stressed spinal implants such as intervertebral cages has not been investigated. Therefore, a combined experimental and analytical study was performed to address these open questions. A quasi-static mechanical compression test was performed to compare the initial mechanical properties of PEEK-OPTIMA polymer in a dry, room-temperature and in an aqueous, 37 degrees C environment (n=10 per group). The creep behaviour of cylindrical PEEK polymer specimens (n=6) was measured in a simulated physiological environment at an applied stress level of 10 MPa for a loading duration of 2000 hours (12 weeks). To compare the biomechanical performance of different intervertebral cage types made from PEEK and titanium under complex loading conditions, a three-dimensional finite element model of a functional spinal unit was created. The elastic modulus of PEEK polymer specimens in a physiological environment was 1.8% lower than that of specimens tested at dry, room temperature conditions (P<0.001). The results from the creep test showed an average creep strain of less than 0.1% after 2000 hours of loading. The finite element analysis demonstrated high strain and stress concentrations at the bone/implant interface, emphasizing the importance of cage geometry for load distribution. The stress and strain maxima in the implants were well below the material strength limits of PEEK. In summary, the experimental results verified the mechanical stability of the PEEK-OPTIMA polymer in a simulated physiological environment, and over extended loading periods. Finite element analysis supported the use of PEEK-OPTIMA for load-bearing intervertebral implants.

Benzophenones↗

Clinical measurements of cement injection pressure during vertebroplasty.

STUDY DESIGN: Clinical study of injection pressure during vertebroplasty. OBJECTIVES: To investigate the range of injection pressures during conventional vertebroplasty interventions and to study the influence of syringe design and cement polymerization time on injection pressure. SUMMARY OF BACKGROUND DATA: Vertebroplasty is an efficient procedure for the treatment of painful vertebral fractures. However, cement leakage is a potentially serious complication. Although injection pressure has been suggested as a factor for extravasation risk, to date, there are only anecdotal reports of pressure data for cement augmentation in the clinic. METHODS: Using a syringe holder instrumented with load and displacement transducers, injection pressure and volume were recorded in vivo during conventional cement augmentation. Wide (3 mm opening) and normal (1.8 mm opening) syringes were alternated such that each type was evaluated for early (300-500 seconds postmixing) and late (>500 seconds postmixing) cement polymerization time. The influence of syringe type and polymerization time on injection pressure was evaluated using a multifactorial analysis of variance followed by Scheffe post hoc comparison. RESULTS: The maximum peak injection pressure measured was 3215 kPa. The average pressure peaks for normal and wide syringes were 1693 +/- 653 kPa and 1727 +/- 597 kPa, respectively. No statistically significant differences were found between injection pressures with wide and normal syringes. Higher injection pressures were observed later in the polymerization process. CONCLUSIONS: High injection pressures approaching 20 atmospheres are reached during conventional vertebroplasty. Widening the syringe tip diameter did not significantly change injection pressures, whereas elapsed time did. Further research is needed to improve injection equipment and materials for vertebroplasty.

Aged↗

A novel computational method for real-time preoperative assessment of primary dental implant stability.

A novel methodology which allows for fast and fully automatic structural analysis during preoperative planning for dental implant surgery is presented. This method integrates a fully automatic fast finite element solver within the framework of new concepts in computer-assisted preoperative planning for implant surgery. The planning system including optimized structural planning was validated by experimental results. Nine implants were placed in pig mandibles and mechanically loaded using a testing rig. The resulting displacements were measured and compared with those predicted by numerical analysis during planning. The results show that there were no statistically significant differences (P = 0.65) between the results of the models and the experiments. The results show that fast structural analysis can be integrated with surgical planning software allowing the initial axial implant stability to be predicted in real time during planning. It is believed that such a system could be used to select patients for immediate implant loading and, when further developed, be useful in other areas of preoperative surgical planning.

Animals↗

Primary stability of a robodoc implanted anatomical stem versus manual implantation.

OBJECTIVE: To assess the initial stability of anatomical stems implanted in manually broached femoral cavities compared with that assessed in cavities milled with the robodoc system. DESIGN: The bone-prosthesis interface motion was measured in matched pairs of cadaveric femora to assess the initial stability of anatomical stems implanted with two different implantation techniques. BACKGROUND: The high costs of surgical robots and the increased perioperative efforts associated with their use can only be justified if measurable benefits for patients can be achieved. Increased initial stability of the stem as an early indicator for better bone ongrowth would be such a benefit. METHODS: Seven pairs of fresh frozen human cadaveric femora were used. One femur of each pair was randomly assigned to receive the robotic milling method; the other femur underwent manual broaching by an experienced surgeon. Initial micromotions of the anatomical stems were measured during simulated gait cycles with loads of < or =1500 N, and both groups underwent matched-pair analysis. Results. High motion of the prostheses was found for both implantation techniques. CONCLUSIONS: The robodoc system did not enhance the primary stability of the anatomical prosthesis compared with the manual broaching method.

Adult↗

Simulated influence of osteoporosis and disc degeneration on the load transfer in a lumbar functional spinal unit.

As life expectancy increases, age-related disorders and the search for related medical care will expand. Osteoporosis is the most frequent skeletal disease in this context with the highest fracture risk existing for vertebrae. The aging process is accompanied by systemic changes, with the earliest degeneration occurring in the intervertebral discs. The influence of various degrees of disc degeneration on the load transfer was examined using the finite element method. The effect of different possible alterations of the bone quality due to osteoporosis was simulated by adjusting the corresponding material properties and their distribution and several loadings were applied. An alteration of the load transfer, characterised by changed compression stiffness and strain distributions as well as magnitudes, due to osteoporotic bone and degenerated discs was found. When osteoporosis was simulated, the stiffness was substantially decreased, larger areas of the cancellous bone were subjected to higher strains and strain maxima were increased. Increasing ratios of transverse isotropy in the osteoporotic bone yielded smaller effects than reduced bone properties. Including a degenerated disc mainly altered the strain distribution. Combining osteoporosis and degenerated discs reduced the areas of cancellous bone subjected to substantial strain. Based on these results, it can be concluded that the definition of a healthy disc in osteoporotic spines might be considered as a worst-case scenario. One attempt to evaluate the progress of osteoporosis can be made by introducing increasing degrees of anisotropy. If several parameters in a model are changed to simulate degeneration, it should be pointed out how each individual definition influences the overall result.

Bone Density↗

Fluid flow and convective transport of solutes within the intervertebral disc.

Previous experimental and analytical studies of solute transport in the intervertebral disc have demonstrated that for small molecules diffusive transport alone fulfils the nutritional needs of disc cells. It has been often suggested that fluid flow into and within the disc may enhance the transport of larger molecules. The goal of the study was to predict the influence of load-induced interstitial fluid flow on mass transport in the intervertebral disc. An iterative procedure was used to predict the convective transport of physiologically relevant molecules within the disc. An axisymmetric, poroelastic finite-element structural model of the disc was developed. The diurnal loading was divided into discrete time steps. At each time step, the fluid flow within the disc due to compression or swelling was calculated. A sequentially coupled diffusion/convection model was then employed to calculate solute transport, with a constant concentration of solute being provided at the vascularised endplates and outer annulus. Loading was simulated for a complete diurnal cycle, and the relative convective and diffusive transport was compared for solutes with molecular weights ranging from 400 Da to 40 kDa. Consistent with previous studies, fluid flow did not enhance the transport of low-weight solutes. During swelling, interstitial fluid flow increased the unidirectional penetration of large solutes by approximately 100%. Due to the bi-directional temporal nature of disc loading, however, the net effect of convective transport over a full diurnal cycle was more limited (30% increase). Further study is required to determine the significance of large solutes and the timing of their delivery for disc physiology.

Animals↗

Three-dimensional motion pattern of the caudal lumbar and lumbosacral portions of the vertebral column of dogs.

OBJECTIVE: To evaluate the 3-dimensional motion pattern including main and coupled motions of the caudal lumbar and lumbosacral portions of the vertebral column of dogs. ANIMALS: Vertebral columns of 9 German Shepherd Dogs (GSDs) and 16 dogs of other breeds with similar body weights and body conditions. PROCEDURE: Main and coupled motions of the caudal lumbar and lumbosacral portions of the vertebral column (L4 to S1) were determined by use of a testing apparatus that permitted precise application of known pure moments to the vertebral column. Motion was compared between GSDs and dogs of other breeds. RESULTS: All specimens had a similar motion pattern consisting of main motion and a certain amount of coupled motion including translation. Vertebral columns of GSDs had significantly less main motion in all directions than that of dogs of other breeds. Translation was similar in GSDs and dogs of other breeds and was smallest at the lumbosacral motion segment. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that motion in the caudal lumbar and lumbosacral portions of the vertebral column of dogs is complex and provided a basis for further studies evaluating abnormal vertebral columns.

Animals↗

Biomechanics of the aging spine.

The human spine is composed of highly specific tissues and structures, which together provide the extensive range of motion and considerable load carrying capacity required for the physical activities of daily life. Alterations to the form and composition of the individual structures of the spine with increasing age can increase the risk of injury and can have a profound influence on the quality of life. Cancellous bone forms the structural framework of the vertebral body. Individual trabeculae are oriented along the paths of principal forces and play a crucial role in the transfer of the predominantly compressive forces along the spine. Age-related changes to the cancellous core of the vertebra includes a loss of bone mineral density, as well as morphological changes including trabecular thinning, increased intratrabecular spacing, and loss of connectivity between trabeculae. Material and morphological changes may lead to an increased risk of vertebral fracture. The vertebral endplate serves the dual role of containing the adjacent disc and evenly distributing applied loads to the underlying cancellous bone and the cortex of the vertebra. With aging, thinning of the endplate, and loss of bone mineral density increases the risk of endplate fracture. Ossification of the endplate may have consequences for the nutritional supply and hydration of the intervertebral disc. The healthy intervertebral disc provides mobility to the spine and transfers load via hydrostatic pressurization of the hydrated nucleus pulposus. Changes to the tissue properties of the disc, including dehydration and reorganization of the nucleus and stiffening of the annulus fibrosus, markedly alter the mechanics of load transfer in the spine. There is no direct correlation between degenerative changes to the disc and to the adjacent vertebral bodies. Furthermore, advancing age is not the sole factor in the degeneration of the spine. Further study is crucial for understanding the unique biomechanical function of the aging spine.

Aged↗

Posterior thoracic extrapedicular fixation: a biomechanical study.

STUDY DESIGN: In vitro biomechanical testing of thoracic spine specimens using a standardized three-dimensional spine flexibility protocol. OBJECTIVES: To compare the mechanical stability of the intrapedicular and extrapedicular technique for pedicle screw placement. The hypothesis was that extrapedicular screw placement provides an equally rigid construct. SUMMARY OF BACKGROUND DATA: Pedicle screws provide rigid fixation of instabilities in the lumbar and lumbosacral spine. Anatomic considerations and the potential risk of neurologic complications are the main reasons to hesitate using pedicle screws in the thoracic spine. Extrapedicular fixation would allow safer insertion due to an increased distance to the spinal canal. METHODS: Twelve human cadaveric thoracic spines (six intra-, six extrapedicular) were instrumented with the USS system, using computed tomography-based computer navigation to ensure accurate placement. The specimens were tested in flexion-extension, torsion, and lateral bending. The ROM was measured using an optoelectronic system, and the two methods were compared before and after implantation of the USS construct and before and after fatigue testing of the construct. RESULTS: The ROM of the instrumented spine was reduced to less than 50% that of its original ROM. There were no statistically significant differences in the ROM reduction between the intra- and the extrapedicular technique. Cyclic fatiguing of the construct did not significantly increase the ROM. CONCLUSIONS: The extrapedicular technique provides a construct for stabilization of the thoracic spine that is as rigid as the conventional intrapedicular technique, but has the advantage of a safer surgical screw insertion.

Adult↗

The importance of the endplate for interbody cages in the lumbar spine.

Intervertebral cages in the lumbar spine represent an advancement in spinal fusion to relieve low back pain. Different implant designs require different endplate preparations, but the question of to what extent preservation of the bony endplate might be necessary remains unanswered. In this study the effects of endplate properties and their distribution on stresses in a lumbar functional spinal unit were investigated using finite-element analyses. Three-dimensional finite-element models of L2-L3 with and without a cage were used. An anterior approach for a monobloc, box-shaped cage was modelled. The results showed that inserting a cage increased the maximum von Mises stress and changed the load distribution in the adjacent structures. A harder endplate led to increased concentration of the stress peaks and high stresses were propagated further into the vertebral body, into areas that would usually not experience such stresses. This may cause structural changes and provide an explanation for the damage occurring to the underlying bone, as well as for the subsequent subsidence of the cage. Stress distributions were similar for the two endplate preparation techniques of complete endplate preservation and partial endplate removal from the centre. It can be concluded that cages should be designed such that they rely on the strong peripheral part of the endplate for support and offer a large volume for the graft. Furthermore, the adjacent vertebrae should be assessed to ensure that they show sufficient density in the peripheral regions to tolerate the altered load transfer following cage insertion until an adequate adaptation to the new loading situation is produced by the remodelling process.

Computer Simulation↗

The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis.

STUDY DESIGN: The effect of cement augmentation on an osteoporotic lumbar functional spinal unit was investigated using finite-element analysis. OBJECTIVE: To evaluate the influence of cement augmentation on load transfer, stresses, and strains. SUMMARY OF BACKGROUND DATA: Osteoporosis is the most frequent skeletal disease of the elderly, leading to weakness of the bony structures. Cement injection into vertebral bodies has been used to treat osteoporotic compression fractures of the spine. The clinical results are encouraging. Experimental biomechanical studies showed significant increases in stiffness and strength of treated bodies. However, little is known about the consequences for the adjacent, nontreated levels. METHODS: Three-dimensional finite-element models of L2-L3 were developed and the material properties adapted to simulate osteoporosis. The influence of augmentation level as well as uni- and bipedicular filling with polymethylmethacrylate were investigated. Compression, flexion, and lateral bending were simulated. RESULTS: Augmentation increased the pressure in the nucleus pulposus and the deflection of the adjacent endplate. The stresses and strains in the vertebrae next to an augmentation were increased, and their distribution was changed. Larger areas were subjected to higher stresses and strains. The treatment clearly altered the load transfer. Changes to the overall stress and strain distribution were less pronounced for unipedicular augmentation. CONCLUSIONS: Cement augmentation restores the strength of treated vertebrae, but leads to increased endplate bulge and an altered load transfer in adjacent vertebrae. This supports the hypothesis that rigid cement augmentation may facilitate the subsequent collapse of adjacent vertebrae. Further study is required to determine the optimal reinforcement material and filling volume to minimize this effect.

Biomechanical Phenomena↗

Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis.

Intervertebral cages in the lumbar spine have been an advancement in spinal fusion to relieve low back pain. Even though initial stability is accepted as a requirement for fusion, there are other factors. The load transfer and its effect on the tissues adjacent to the cage may also play an essential role, which is not easily detectable with experimental tests. In this study the effects of an intervertebral cage insertion on a lumbar functional spinal unit were investigated using finite element analyses. The influences of cage material, cancellous bone density and spinal loading for the stresses in a functional spinal unit were evaluated. Three-dimensional (3D) finite element models of L2-L3 were developed for this purpose. An anterior approach for a monobloc, box-shaped cage was modelled. Models with cage were compared to the corresponding intact ones. The results showed that inserting a cage increased the maximum von Mises stress and changed the load transfer in the adjacent structures. Varying the cage material or the loading conditions had a much smaller influence than varying the cancellous bone density. The denser the cancellous bone, the more the stress was concentrated underneath the cage, while the remaining regions were unloaded. This study showed that the density of the underlying cancellous bone is a more important factor for the biomechanical behaviour of a motion segment stabilized with a cage, and its eventual clinical success, than the cage material or the applied load. Inserting an intervertebral cage markedly changed the load transfer. The altered stress distribution may trigger bone remodelling and explain damage of the underlying vertebrae.

Adult↗