PubMed Health⌕ Search

Biomedical subjects

Stephen J Norton

Publications and source records attributed to Stephen J Norton.

4 recordsLinked to original sources

Can ultrasound be used to stimulate nerve tissue?

BACKGROUND: The stimulation of nerve or cortical tissue by magnetic induction is a relatively new tool for the non-invasive study of the brain and nervous system. Transcranial magnetic stimulation (TMS), for example, has been used for the functional mapping of the motor cortex and may have potential for treating a variety of brain disorders. METHODS AND RESULTS: A new method of stimulating active tissue is proposed by propagating ultrasound in the presence of a magnetic field. Since tissue is conductive, particle motion created by an ultrasonic wave will induce an electric current density generated by Lorentz forces. An analytical derivation is given for the electric field distribution induced by a collimated ultrasonic beam. An example shows that peak electric fields of up to 8 V/m appear to be achievable at the upper range of diagnostic intensities. This field strength is about an order of magnitude lower than fields typically associated with TMS; however, the electric field gradients induced by ultrasound can be quite high (about 60 kV/m2 at 4 MHz), which theoretically play a more important role in activation than the field magnitude. The latter value is comparable to TMS-induced gradients. CONCLUSION: The proposed method could be used to locally stimulate active tissue by inducing an electric field in regions where the ultrasound is focused. Potential advantages of this method compared to TMS is that stimulation of cortical tissue could be highly localized as well as achieved at greater depths in the brain than is currently possible with TMS.

Electric Stimulation↗

Optoacoustic diffraction tomography: analysis of algorithms.

We consider the problem of using the photoacoustic effect to image the optical properties of tissue. A region of tissue is assumed to be illuminated by frequency-modulated light that creates an ultrasonic wave of the same frequency. This wave is detected on a passive array of receiving transducers distributed over a circular or a cylindrical aperture. If the frequency is swept over a broad band (or, equivalently, if we illuminate with a pulse and Fourier transform the response), then a spatial map of a parameter that depends on the optical absorption coefficient of the tissue can be recovered. Analytical inversion formulas are derived in both two and three dimensions. The effects of band-limited data on image quality are also investigated.

Algorithms↗

Synthetic aperture imaging with arrays of arbitrary shape--part I: General case.

The problem of synthesizing full-aperture resolution with linear transmitting and receiving arrays of arbitrary shape is considered. The arrays are assumed to lie in the same plane and can be open (e.g., curved or straight line segments) or closed (e.g., circles). It is shown that a full (area) aperture can be synthesized by suitably weighting the transmitted and received signals. This weighting turns out to be the Jacobian of a transformation that yields uniform coverage in the spatial-frequency domain. If the Jacobian is factorable, then full-aperture resolution can be achieved in a single transmission. The theory is illustrated with two annular arrays of different diameter: one that transmits and one that receives. If the radii of the annular arrays are a and b, then the synthesized point-spread function (PSF) is shown to be equivalent to that of a filled circular aperture of radius a + b.

Journal Article↗

Synthetic aperture imaging with arrays of arbitrary shape--part II: The annular array.

It has been previously shown that full aperture resolution can be achieved with an annular transducer array by transmitting and receiving between all pairs of elements around the array circumference and applying an appropriate weighting function. If there are N elements in the array, this requires N transmissions. This paper shows that full aperture resolution can be obtained with a much smaller number of transmissions (two to four) by using a certain aperture phase weighting on transmit and receive. Thus, full aperture, real-time imaging from an annular array should be feasible.

Journal Article↗