PubMed Health⌕ Search

Biomedical subjects

Stephen J Valentine

Publications and source records attributed to Stephen J Valentine.

16 recordsLinked to original sources

An IMS-IMS analogue of MS-MS.

The development of a new ion mobility/mass spectrometry instrument that incorporates a multifield drift tube/ion funnel design is described. In this instrument, individual components from a mixture of ions can be resolved and selected on the basis of mobility differences prior to collisional activation inside the drift tube. The fragment ions that are produced can be dispersed again in a second ion mobility spectrometry (IMS) region prior to additional collisional activation and MS analysis. The result is an IMS-IMS analogue of MS-MS. Here, we describe the preliminary instrumental design and experimental approach. We illustrate the approach by examining the highly characterized bradykinin and ubiquitin systems. Mobility-resolved fragment ions of bradykinin show that b-type ions are readily discernible fragments, because they exist as two easily resolvable structural types. Current limitations and future directions are briefly discussed.

Bradykinin↗

IMS-IMS and IMS-IMS-IMS/MS for separating peptide and protein fragment ions.

Multidimensional ion mobility spectrometry (IMS-IMS and IMS-IMS-IMS) techniques have been combined with mass spectrometry (MS) and investigated as a means of generating and separating peptide and protein fragment ions. When fragments are generated inside a drift tube and then dispersed by IMS prior to MS analysis, it is possible to observe many features that are not apparent from MS analysis alone. The approach is demonstrated by examining fragmentation patterns arising from electrospray ion distributions of insulin chain B and ubiquitin. The multidimensional IMS approach makes it possible to select individual components for collisional activation and to disperse fragments based on differences in mobility prior to MS analysis. Such an approach makes it possible to observe many features not apparent by MS analysis alone.

Amino Acid Sequence↗

Coupling desorption electrospray ionization with ion mobility/mass spectrometry for analysis of protein structure: evidence for desorption of folded and denatured States.

A desorption electrospray ionization (DESI) source has been coupled to an ion mobility time-of-flight mass spectrometer for the analysis of proteins. Analysis of solid-phase horse heart cytochrome c and chicken egg white lysozyme proteins with different DESI solvents and conditions shows similar mass spectra and charge state distributions to those formed when using electrospray to analyze these proteins in solution. The ion mobility data show evidence for compact ion structures [when the surface is exposed to a spray that favors retention of "nativelike" structures (50:50 water:methanol)] or elongated structures [when the surface is exposed to a spray that favors "denatured" structures (49:49:2 water:methanol:acetic acid)]. The results suggest that the DESI experiment is somewhat gentler than ESI and under appropriate conditions, it is possible to preserve structural information throughout the DESI process. Mechanisms that are consistent with these results are discussed.

Absorption↗

Split-field drift tube/mass spectrometry and isotopic labeling techniques for determination of single amino acid polymorphisms.

A combination of split-field drift tube/mass spectrometry and isotopic labeling techniques is evaluated as a means of identifying single amino acid polymorphisms (SAAPs) in proteins. The method is demonstrated using cytochromec (equine and bovine) and hemoglobin (bovine and sheep). For these studies, proteins from different species are digested with trypsin, and the peptides are labeled at primary amine groups [using either a light (H(3))- or heavy (D(3))-isotopic reagent]. SAAP analysis is carried out by mixing the light-labeled peptides of one species with the heavy-labeled peptides of the other and electrospraying the resulting mixture into a split-field drift tube/mass spectrometer. Peptides having the same sequence in both species appear as doublets in the mass spectrum [shifted in mass-to-charge (m/z) according to the number of incorporated labels]; additionally, these species have identical mobility distributions. Peptides having sequences that differ by one amino acid appear as peaks in the mass spectrum that are shifted in m/z according to the mass difference associated with the SAAP and the number of incorporated labels. The ion mobility distributions for these peptides (differing by only a single amino acid) can often be rationalized by their expected similarities or differences providing additional evidence that they are related. In all, 12 and 26 peptide variants (between species) corresponding to 5 and 11 amino acid polymorphisms have been identified for the cytochrome c and hemoglobin protein samples, respectively.

Amino Acid Sequence↗

Toward plasma proteome profiling with ion mobility-mass spectrometry.

Differential, functional, and mapping proteomic analyses of complex biological mixtures suffer from a lack of component resolution. Here we describe the application of ion mobility-mass spectrometry (IMS-MS) to this problem. With this approach, components that are separated by liquid chromatography are dispersed based on differences in their mobilities through a buffer gas prior to being analyzed by MS. The inclusion of the gas-phase dispersion provides more than an order of magnitude enhancement in component resolution at no cost to data acquisition time. Additionally, the mobility separation often removes high-abundance species from spectral regions containing low-abundance species, effectively increasing measurement sensitivity and dynamic range. Finally, collision-induced dissociation of all ions can be recorded in a single experimental sequence while conventional MS methods sequentially select precursors. The approach is demonstrated in a single, rapid (3.3 h) analysis of a plasma digest sample where abundant proteins have not been removed. Protein database searches have yielded 731 high confidence peptide assignments corresponding to 438 unique proteins. Results have been compiled into an initial analytical map to be used -after further augmentation and refinement- for comparative plasma profiling studies.

Blood Proteins↗

Developing liquid chromatography ion mobility mass spectometry techniques.

When a packet of ions in a buffer gas is exposed to a weak electric field, the ions will separate according to differences in their mobilities through the gas. This separation forms the basis of the analytical method known as ion mobility spectroscopy and is highly efficient, in that it can be carried out in a very short time frame (micro- to milliseconds). Recently, efforts have been made to couple the approach with liquid-phase separations and mass spectrometry in order to create a high-throughput and high-coverage approach for analyzing complex mixtures. This article reviews recent work to develop this approach for proteomics analyses. The instrumentation is described briefly. Several multidimensional data sets obtained upon analyzing complex mixtures are shown in order to illustrate the approach as well as provide a view of the limitations and required future work.

Animals↗

Nanoflow LC/IMS-MS and LC/IMS-CID/MS of protein mixtures.

A simple ion trap/ion mobility/time-of-flight (TOF) mass spectrometer has been coupled with nanoflow liquid chromatography to examine the feasibility of analyzing mixtures of intact proteins. In this approach proteins are separated using reversed-phase chromatography. As components elute from the column, they are electrosprayed into the gas phase and separated again in a drift tube prior to being dispersed and analyzed in a TOF mass spectrometer. The mobilities of ions through a buffer gas depend upon their collision cross sections and charge states; separation based on these gas-phase parameters provides a new means of simplifying mass spectra and characterizing mixtures. Additionally it is possible to induce dissociation at the exit of the drift tube and examine the fragmentation patterns of specific protein ion charge states and conformations. The approach is demonstrated by examining a simple three-component mixture containing ubiquitin, cytochrome c, and myoglobin and several larger prepared protein mixtures. The potential of this approach for use in proteomic applications is considered.

Animals↗

Development of high throughput dispersive LC-ion mobility-TOFMS techniques for analysing the human plasma proteome.

A technique that combines ion mobility spectrometry (IMS) with reversed-phase liquid chromatography (LC), collision-induced dissociation (CID) and mass spectrometry (MS) has been developed. The approach is described as a high throughput means of analysing complex mixtures of peptides that arise from enzymatic digestion of protein mixtures. In this approach, peptides are separated by LC and, as they elute from the column, they are introduced into the gas phase and ionised by electrospray ionisation. The beam of ions is accumulated in an ion trap and then the concentrated ion packet is injected into a drift tube where the ions are separated again in the gas phase by IMS, a technique that differentiates ions based on their mobilities through a buffer gas. As ions exit the drift tube, they can be subjected to collisional activation to produce fragments prior to being introduced into a mass spectrometer for detection. The IMS separation can be carried out in only a few milliseconds and offers a number of advantages compared with LC-MS alone. An example of a single 21-minute LC-IMS-(CID)-MS analysis of the human plasma proteome reveals approximately 20,000 parent ions and approximately 600,000 fragment ions and evidence for 227 unique protein assignments.

Chromatography, Liquid↗

A split-field drift tube for separation and efficient fragmentation of biomolecular ions.

A new ion mobility instrument that incorporates a low-field region for ion separation and a high-field region for collisional activation is described. In this approach, mixtures of ions are separated based on differences in their mobilities in a approximately 20-cm-long low-field ( approximately 5 V cm(-)(1)) region of a drift tube. As the ions approach the drift tube exit, they are exposed to a large focusing potential drop; at high fields, ions are efficiently collisionally activated and dissociate as they exit the drift tube. We have demonstrated this approach by examining the fragmentation pattern for electrosprayed bradykinin ions. These studies show that the activation process is highly tunable; it is possible to modulate the field such that precursor ion mass spectra as well as several high-field collision-induced fragmentation patterns can be obtained. The approach also appears to be a simple means of activating protein ions, as demonstrated by examining electrosprayed myoglobin ions.

Bradykinin↗

Development of high-sensitivity ion trap ion mobility spectrometry time-of-flight techniques: a high-throughput nano-LC-IMS-TOF separation of peptides arising from a Drosophila protein extract.

A linear octopole trap interface for an ion mobility time-of-flight mass spectrometer has been developed for focusing and accumulating continuous beams of ions produced by electrospray ionization. The interface improves experimental efficiencies by factors of approximately 50-200 compared with an analogous configuration that utilizes a three-dimensional Paul geometry trap (Hoaglund-Hyzer, C. S.; Lee, Y. J.; Counterman, A. E.; Clemmer, D. E. Anal. Chem. 2002, 74, 992-1006). With these improvements, it is possible to record nested drift (flight) time distributions for complex mixtures in fractions of a second. We demonstrate the approach for several well-defined peptide mixtures and an assessment of the detection limits is given. Additionally, we demonstrate the utility of the approach in the field of proteomics by an on-line, three-dimensional nano-LC-ion mobility-TOF separation of tryptic peptides from the Drosophila proteome.

Animals↗

Development of high-throughput liquid chromatography injected ion mobility quadrupole time-of-flight techniques for analysis of complex peptide mixtures.

The development of a multidimensional approach involving high-performance liquid chromatography (LC), ion mobility spectrometry (IMS) and tandem mass spectrometry is described for the analysis of complex peptide mixtures. In this approach, peptides are separated based on differences in their LC retention times and mobilities (as ions drift through He) prior to being introduced into a quadrupole/octopole/time-of-flight mass spectrometer. The initial LC separation and IMS dispersion of ions is used to label ions for subsequent fragmentation studies that are carried out for mixtures of ions. The approach is demonstrated by examining a mixture of peptides generated from tryptic digestion of 18 commercially available proteins. Current limitations of this initial study and potential advantages of the experimental approach are discussed.

Amino Acid Sequence↗

Resolving isomeric peptide mixtures: a combined HPLC/ion mobility-TOFMS analysis of a 4000-component combinatorial library.

A reversed-phase high-performance liquid chromatography (HPLC) separation approach has been combined with ion mobility/time-of-flight (TOF) mass spectrometry in order to characterize a combinatorial peptide library designed to contain 4000 peptides of the general form NH2-Xxx-Xxx-XXX-CO2H, NH2-Ala-Xxx-Xxx-Xxx-CO2H, NH2-Ser-Ala-Xxx-Xxx-Xxx-CO2H and NH2-Leu-Ser-Ala-Xxx-Xxx-Xxx-CO2H (where Xxx represents a randomization over 10 different amino acids: Ala, Arg, Asp, Glu, Gly, Leu, Lys, Phe, Ser, and Val). Addition of the gas-phase mobility separation between the HPLC separation and TOF measurement dimensions makes it possible to resolve many peptide isomers that have identical retention times (and masses).

Chromatography, High Pressure Liquid↗

Temperature-dependent H/D exchange of compact and elongated cytochrome c ions in the gas phase.

Isotopic exchange reactions of compact and elongated conformations of gaseous cytochrome c ions (+5 and +9 states) with D2O have been measured as a function of temperature (from 300 to approximately 440 K) using ion mobility techniques. Rate constants for those sites that exchange at high temperatures (>400 K) are about an order of magnitude smaller than rate constants for sites that exchange at 300 K. Although the exchange rates decrease, the maximum exchange levels for rapidly exchanging sites increase with temperature. At 300 K, exchange levels of 53 +/- 3 and 63 +/- 3 are measured for the compact and elongated states, respectively. From 300 to 335 K, the exchange levels increase slightly to approximately 60 to 70 hydrogens. Above 335 K, the levels increase to a value of approximately 200 for the +5 state and approximately 190 for the +9 state, near the maximum possible levels, 200 and 204 for these respective charge states. Molecular dynamics simulations have been carried out on structures having calculated cross sections that are near the experimental values in order to explore the exchange process. Overall, it appears that charge site and exchange site proximities are important factors in the exchange profiles for the elongated +9 ion and the compact +5 ion.

Algorithms↗

Development of field modulation in a split-field drift tube for high-throughput multidimensional separations.

A field modulation approach for high-throughput ion mobility/time-of-flight analyses of complex mixtures has been developed using a split-field drift tube. In this approach, complex mixtures of peptides, such as those that arise from tryptic digestion of protein mixtures, are separated by nanocolumn liquid chromatography, ionized by electrospray ionization, and analyzed by ion mobility/time-of-flight techniques. The split-field drift tube allows parent ions to be separated based on differences in their low-field mobilities through the first-field region before entering the second region. For increased throughput, the magnitude of the field in the second region can be modulated throughout an LC separation in order to favor transmission of different types of ions: parent ions at low fields; fragments from primarily [M+3H]3+ peptides at moderate fields; or, fragmentation of [M+3H]3+ and [M+2H]2+ species at higher fields. We demonstrate the approach with two examples: a mixture of tryptic peptides from digestion of hemoglobin; and a complex mixture of tryptic peptides from digestion of human plasma.

Blood Proteins↗

Proteome profiling for assessing diversity: analysis of individual heads of Drosophila melanogaster using LC-ion mobility-MS.

The proteomes of three heads of individual Drosophila melanogaster organisms have been analyzed and compared by a combination of liquid chromatography, ion mobility spectrometry, and mass spectrometry approaches. In total, 197 proteins are identified among all three individuals (an average of 120 +/- 20 proteins per individual), of which at least 101 proteins are present in all three individuals. Within all three datasets, more than 25 000 molecular ions (an average of 9000 +/- 2000 per individual) corresponding to protonated precursor ions of individual peptides have been observed. A comparison of peaks among the datasets reveals that peaks corresponding to protonated peptides that are found in all heads are more intense than those features that appear between pairs of or within only one of the individuals. Moreover, there is little variability in the relative intensities of the peaks common among all individuals. It appears that it is the lower abundance components of the proteome that play the most significant role in determining unique features of individuals.

Animals↗

Mapping the proteome of Drosophila melanogaster: analysis of embryos and adult heads by LC-IMS-MS methods.

Multidimensional separations combined with mass spectrometry are used to study the proteins that are present in two states of Drosophila melanogaster: the whole embryo and the adult head. The approach includes the incorporation of a gas-phase separation dimension in which ions are dispersed according to differences in their mobilities and is described as a means of providing a detailed analytical map of the proteins that are present. Overall, we find evidence for 1133 unique proteins. In total, 780 are identified in the head, and 660 are identified in the embryo. Only 307 proteins are in common to both developmental stages, indicating that there are significant differences in these proteomes. A comparison of the proteome to a database of mRNAs that are found from analysis by cDNA approaches (i.e., transcriptome) also shows little overlap. All of this information is discussed in terms of the relationship between the predicted genome, and measured transcriptomes and proteomes. Additionally, the merits and weaknesses of current technologies are assessed in some detail.

Animals↗