A nanoliter-scale nucleic acid processor with parallel architecture.

The purification of nucleic acids from microbial and mammalian cells is a crucial step in many biological and medical applications. We have developed microfluidic chips for automated nucleic acid purification from small numbers of bacterial or mammalian cells. All processes, such as cell isolation, cell lysis, DNA or mRNA purification, and recovery, were carried out on a single microfluidic chip in nanoliter volumes without any pre- or postsample treatment. Measurable amounts of mRNA were extracted in an automated fashion from as little as a single mammalian cell and recovered from the chip. These microfluidic chips are capable of processing different samples in parallel, thereby illustrating how highly parallel microfluidic architectures can be constructed to perform integrated batch-processing functionalities for biological and medical applications.

Animals↗

A microfluidic rectifier: anisotropic flow resistance at low Reynolds numbers.

It is one of the basic concepts of Newtonian fluid dynamics that at low Reynolds number (Re) the Navier-Stokes equation is linear and flows are reversible. In microfluidic devices, where Re is essentially always low, this implies that flow resistance in microchannels is isotropic. Here we present a microfluidic rectifier: a microscopic channel of a special shape whose flow resistance is strongly anisotropic, differing by up to a factor of 2 for opposite flow directions. Its nonlinear operation at arbitrary small Re is due to non-Newtonian elastic properties of the working fluid, which is a 0.01% aqueous solution of a high molecular weight polymer. The rectifier works as a dynamic valve and may find applications in microfluidic pumps and other integrated devices.

Journal Article↗

Solvent-resistant photocurable liquid fluoropolymers for microfluidic device fabrication [corrected].

We report the first fabrication of a solvent-compatible microfluidic device based on photocurable "Liquid Teflon" materials. The materials are highly fluorinated functionalized perfluoropolyethers (PFPEs) that have liquidlike viscosities that can be cured into tough, highly durable elastomers that exhibit the remarkable chemical resistance of fluoropolymers such as Teflon. Poly(dimethylsiloxane) (PDMS) elastomers have rapidly become the material of choice for many recent microfluidic device applications. Despite the advantages of PDMS in relation to microfluidics technology, the material suffers from a serious drawback in that it swells in most organic solvents. The swelling of PDMS-based devices in organic solvents greatly disrupts the micrometer-sized features and makes it impossible for fluids to flow inside the channels. Our approach to this problem has been to replace PDMS with photocurable perfluoropolyethers. Device fabrication and valve actuation were accomplished using established procedures for PDMS devices. The additional advantage of photocuring allows fabrication time to be decreased from several hours to a matter of minutes. The PFPE-based device exhibited mechanical properties similar to those of Sylgard 184 before and after curing as well as remarkable resistance to organic solvents. This work has the potential to expand the field of microfluidics to many novel applications.

Journal Article↗

Behavior of complex knots in single DNA molecules.

We used optical tweezers to tie individual DNA molecules in knots. Although these knots become highly localized under tension, they remain surprisingly mobile and undergo thermal diffusion with classical random walk statistics. The diffusion constants of knots with different complexities correlate with theoretical calculations of knot sizes. We show that this correlation can be explained by a simple hydrodynamical model of "self-reptation" of the knot along a polymer.

Bacteriophage lambda↗

Solving the "world-to-chip" interface problem with a microfluidic matrix.

We report an effective solution to the macroscopic/microfluidic interface issue and demonstrate how microfluidics can achieve impressive economies of scale in reducing the complexity of pipetting operations. Using an N x N microfluidic matrix with N = 20, we performed N2 = 400 distinct PCR reactions with only 2N + 1 = 41 pipetting steps, compared with the 3N2 = 1200 steps required with conventional fluid handling. Each vertex of the matrix has a 3-nL reactor, and a single 2-microL aliquot of polymerase is amortized over all 400 independent reactions, thus dramatically reducing sample overhead and minimizing reagent consumption. Beyond PCR, the matrix chip provides a general method to perform chemical and biological experiments with precious reagents in a highly automated fashion.

Journal Article↗

Microfabricated fountain pens for high-density DNA arrays.

We used photolithographic microfabrication techniques to create very small stainless steel fountain pens that were installed in place of conventional pens on a microarray spotter. Because of the small feature size produced by the microfabricated pens, we were able to print arrays with up to 25,000 spots/cm2, significantly higher than can be achieved by other deposition methods. This feature density is sufficiently large that a standard microscope slide can contain multiple replicates of every gene in a complex organism such as a mouse or human. We tested carryover during array printing with dye solution, labeled DNA, and hybridized DNA, and we found it to be indistinguishable from background. Hybridization also showed good sequence specificity to printed oligonucleotides. In addition to improved slide capacity, the microfabrication process offers the possibility of low-cost mass-produced pens and the flexibility to include novel pen features that cannot be machined with conventional techniques.

Electrochemistry↗

Microfluidic memory and control devices.

We demonstrate microscopic fluidic control and memory elements through the use of an aqueous viscoelastic polymer solution as a working fluid. By exploiting the fluid's non-Newtonian rheological properties, we were able to demonstrate both a flux stabilizer and a bistable flip-flop memory. These circuit elements are analogous to their solid-state electronic counterparts and could be used as components of control systems for integrated microfluidic devices. Such miniaturized fluidic circuits are insensitive to electromagnetic interference and may also find medical applications for implanted drug-delivery devices.

Journal Article↗

Sequence information can be obtained from single DNA molecules.

The completion of the human genome draft has taken several years and is only the beginning of a period in which large amounts of DNA and RNA sequence information will be required from many individuals and species. Conventional sequencing technology has limitations in cost, speed, and sensitivity, with the result that the demand for sequence information far outstrips current capacity. There have been several proposals to address these issues by developing the ability to sequence single DNA molecules, but none have been experimentally demonstrated. Here we report the use of DNA polymerase to obtain sequence information from single DNA molecules by using fluorescence microscopy. We monitored repeated incorporation of fluorescently labeled nucleotides into individual DNA strands with single base resolution, allowing the determination of sequence fingerprints up to 5 bp in length. These experiments show that one can study the activity of DNA polymerase at the single molecule level with single base resolution and a high degree of parallelization, thus providing the foundation for a practical single molecule sequencing technology.

Base Sequence↗

Microfluidics in structural biology: smaller, faster em leader better.

Microfluidic technologies promise unprecedented savings in cost and time through the integration of complex chemical and biological assays on a microfabricated chip. Recent advances are making elements of this vision a reality, facilitating the first large-scale integration of microfluidic plumbing with biological assays. The power of miniaturization lies not only in achieving an economy of scale, but also in exploiting the unusual physics of fluid flow and mass transport on small length scales to realize precise and efficient assays that are not accessible with macroscopic tools. Diverse applications ranging from time-resolved studies of protein folding to highly efficient protein crystal growth suggest that microfluidics may become an indispensable tool in biology.

Biological Assay↗

Quantifying double-strand breaks and clustered damages in DNA by single-molecule laser fluorescence sizing.

Fluorescence from a single DNA molecule passing through a laser beam is proportional to the size (contour length) of the molecule, and molecules of different sizes can be counted with equal efficiencies. Single-molecule fluorescence can thus determine the average length of the molecules in a sample and hence the frequency of double-strand breaks induced by various treatments. Ionizing radiation-induced frank double-strand breaks can thus be quantified by single-molecule sizing. Moreover, multiple classes of clustered damages involving damaged bases and abasic sites, alone or in combination with frank single-strand breaks, can be quantified by converting them to double-strand breaks by chemical or enzymatic treatments. For a given size range of DNA molecules, single-molecule sizing is as or more sensitive than gel electrophoresis, and requires several orders-of-magnitude less DNA to determine damage levels.

Bacteriophage T7↗

Integrated nanoliter systems.

Microfluidic chip platforms for manipulating liquid volumes in the nanoliter range are slowly inching their way into mainstream genomic and proteomic research. The principal challenge faced by these technologies is the need for high-throughput processing of increasingly smaller volumes, with ever higher degrees of parallelization. Significant advances have been made over the past few years in addressing these needs through electrokinetic manipulation, vesicle encapsulation and mechanical valve approaches. These strategies allow levels of integration density and platform complexity that promise to make them into serious alternatives to current robotic systems.

Chemistry Techniques, Analytical↗

Polyelectrolyte surface interface for single-molecule fluorescence studies of DNA polymerase.

We report the use of polyelectrolyte multilayers in a stable robust surface chemistry for specific anchoring of DNA to glass. The nonspecific binding of fluorescently tagged nucleotides is suppressed down to the single-molecule level, and DNA polymerase is active on the anchored DNA template. This surface-chemistry platform can be used for single-molecule studies of DNA and DNA polymerase and may be more broadly applicable for other situations in which it is important to have specific biomolecular surface chemistry with extremely low nonspecific binding.

Biotinylation↗

A robust and scalable microfluidic metering method that allows protein crystal growth by free interface diffusion.

Producing robust and scalable fluid metering in a microfluidic device is a challenging problem. We developed a scheme for metering fluids on the picoliter scale that is scalable to highly integrated parallel architectures and is independent of the properties of the working fluid. We demonstrated the power of this method by fabricating and testing a microfluidic chip for rapid screening of protein crystallization conditions, a major hurdle in structural biology efforts. The chip has 480 active valves and performs 144 parallel reactions, each of which uses only 10 nl of protein sample. The properties of microfluidic mixing allow an efficient kinetic trajectory for crystallization, and the microfluidic device outperforms conventional techniques by detecting more crystallization conditions while using 2 orders of magnitude less protein sample. We demonstrate that diffraction-quality crystals may be grown and harvested from such nanoliter-volume reactions.

Crystallization↗

Number, density, and surface/cytoplasmic distribution of GABA transporters at presynaptic structures of knock-in mice carrying GABA transporter subtype 1-green fluorescent protein fusions.

GABA transporter subtype 1 (GAT1) molecules were counted near GABAergic synapses, to a resolution of approximately 0.5 microm. Fusions between GAT1 and green fluorescent protein (GFP) were tested in heterologous expression systems, and a construct was selected that shows function, expression level, and trafficking similar to that of wild-type (WT) GAT1. A strain of knock-in mice was constructed that expresses this mGAT1-GFP fusion in place of the WT GAT1 gene. The pattern of fluorescence in brain slices agreed with previous immunocytochemical observations. [3H]GABA uptake, synaptic electrophysiology, and subcellular localization of the mGAT1-GFP construct were also compared with WT mice. Quantitative fluorescence microscopy was used to measure the density of mGAT1-GFP at presynaptic structures in CNS preparations from the knock-in mice. Fluorescence measurements were calibrated with transparent beads and gels that have known GFP densities. Surface biotinylation defined the fraction of transporters on the surface versus those in the nearby cytoplasm. The data show that the presynaptic boutons of GABAergic interneurons in cerebellum and hippocampus have a membrane density of 800-1300 GAT1 molecules per square micrometer, and the axons that connect boutons have a linear density of 640 GAT1 molecules per micrometer. A cerebellar basket cell bouton, a pinceau surrounding a Purkinje cell axon, and a cortical chandelier cell cartridge carry 9000, 7.8 million, and 430,000 GAT1 molecules, respectively; 61-63% of these molecules are on the surface membrane. In cultures from hippocampus, the set of fluorescent cells equals the set of GABAergic interneurons. Knock-in mice carrying GFP fusions of membrane proteins provide quantitative data required for understanding the details of synaptic transmission in living neurons.

Animals↗

Microfluidic large-scale integration.

We developed high-density microfluidic chips that contain plumbing networks with thousands of micromechanical valves and hundreds of individually addressable chambers. These fluidic devices are analogous to electronic integrated circuits fabricated using large-scale integration. A key component of these networks is the fluidic multiplexor, which is a combinatorial array of binary valve patterns that exponentially increases the processing power of a network by allowing complex fluid manipulations with a minimal number of inputs. We used these integrated microfluidic networks to construct the microfluidic analog of a comparator array and a microfluidic memory storage device whose behavior resembles random-access memory.

Biochemistry↗

Significance and statistical errors in the analysis of DNA microarray data.

DNA microarrays are important devices for high throughput measurements of gene expression, but no rational foundation has been established for understanding the sources of within-chip statistical error. We designed a specialized chip and protocol to investigate the distribution and magnitude of within-chip errors and discovered that, as expected from theoretical expectations, measurement errors follow a Lorentzian-like distribution, which explains the widely observed but unexplained ill-reproducibility in microarray data. Using this specially designed chip, we examined a data set of repeated measurements to extract estimates of the distribution and magnitude of statistical errors in DNA microarray measurements. Using the common "ratio of medians" method, we find that the measurements follow a Lorentzian-like distribution, which is problematic for subsequent analysis. We show that a method of analysis dubbed "median of ratios" yields a more Gaussian-like distribution of errors. Finally, we show that the bootstrap algorithm can be used to extract the best estimates of the error in the measurement. Quantifying the statistical error in such measurements has important applications for estimating significance levels, clustering algorithms, and process optimization.

Algorithms↗

An integrated microfabricated cell sorter.

We have developed an integrated microfabricated cell sorter using multilayer soft lithography. This integrated cell sorter is incorporated with various microfluidic functionalities, including peristaltic pumps, dampers, switch valves, and input and output wells, to perform cell sorting in a coordinated and automated fashion. The active volume of an actuated valve on this integrated cell sorter can be as small as 1 pL, and the volume of optical interrogation is approximately 100 fL. Different algorithms of cell manipulation, including cell trapping, were implemented in these devices. We have also demonstrated sorting and recovery of Escherichia coli cells on the chip.

Bacteriological Techniques↗

Velocity-independent microfluidic flow cytometry.

Pressure-driven flow in microfluidic channels is characterized by a distribution of velocities. This distribution makes it difficult to implement conventional flow cytometry data analysis. We have demonstrated a method to measure velocity as an independent parameter when performing microfluidic flow cytometry. This method allows velocity-independent analysis of particles such as beads or cells, and allows flow cytometry analysis of extended objects, such as long DNA molecules. It allows accurate flow cytometry in transient and nonuniform flows. This general measurement method could be used in the future to measure the velocity of particles in a variety of existing microfluidic devices without the need for changes in their design.

Bacteriophage lambda↗