Steve Arscott

Publications and source records attributed to Steve Arscott.

5 recordsLinked to original sources

An open design microfabricated nib-like nanoelectrospray emitter tip on a conducting silicon substrate for the application of the ionization voltage.

This paper describes a novel emitter tip having the shape of a nib and based on an open structure for nano-electrospray ionization mass spectrometry (nanoESI-MS). The nib structure is fabricated with standard lithography techniques using SU-8, an epoxy-based negative photoresist. The tip is comprised of a reservoir, a capillary slot and a point-like feature, and is fabricated on a silicon wafer. We present here a novel scheme for interfacing such nib tips to MS by applying the ionization voltage directly onto the semi-conductor support. The silicon support is in direct contact with the liquid to be analyzed at the reservoir and microchannel level, thus allowing easy use in ESI-MS. This scheme is especially advantageous for automated analysis as the manual step of positioning a metallic wire into the reservoir is avoided. In addition, the analysis performance was enhanced compared with the former scheme, as demonstrated by the tests of standard peptides (gramicidin S, Glu-fibrinopeptide B). The limit of detection was determined to be lower than 10(-2) microM. Due to their enhanced performance, these microfabricated sources might be of great interest for analysis requiring very high sensitivity, such as proteomics analysis using nanoESI-MS.

Journal Article↗

Integrated microfabricated systems including a purification module and an on-chip nano electrospray ionization interface for biological analysis.

We report here on an integrated microfabricated device dedicated to the preparation of biological samples prior to their on-line analysis by electrospray ionization-mass spectrometry (ESI-MS). This microfluidic device is fabricated using the negative photoresist SU-8 by microtechnology techniques. The device includes a chromatographic module plus an ESI interface for MS. The chromatographic module is dedicated to sample purification and is based on a polymer monolithic phase which includes hydrophobic moieties. The ESI interface is integrated onto the chip and is based on a capillary slot. We present here the integration of these different modules onto a single system that is fabricated via a SU-8-based microtechnology route. We present also their testing for the purification of peptide samples. This started with a partial integration step with the combination of at least two of the modules (microsystem + monolith; microsystem + nib) and their test before the fabrication and testing of fully integrated microsystems.

Microscopy, Electron, Scanning↗

A novel nib-like design for microfabricated nanospray tips.

We present here novel tips for nanoelectrosray ionization-mass spectrometry (ESI-MS) applications. These ionization sources have a planar geometry in the shape of a nib. Their functioning is based on a principle much akin to that of a fountain pen in that fluids are actuated by capillarity. Once a voltage is applied, an electrospray is formed at the nib tip. The nib fabrication relies on micromachining techniques using the epoxy-based negative photoresist SU-8 and a double exposure photolithographic process. Two types of nib-like sources were fabricated; they were made either conductive by metallization with a nickel layer or non-conductive but hydrophilic by covering them with a SiO(2) layer. In the latter case, the HV was applied via a Pt wire inserted into the reservoir feature of the nib. The nib-like sources were tested on an ion trap mass spectrometer using Gramicidin S samples at concentrations as low as 1 microM and ionization voltages as low as 1.2 kV. We have observed a good overall stability of the spray during the tests with no marked decrease in the signal intensity even under extreme conditions.

Journal Article↗

A planar microfabricated nanoelectrospray emitter tip based on a capillary slot.

We report on the fabrication and testing of planar nib-like structures for nanoelectrospray ionization-mass spectrometry (nanoESI-MS) applications. The micro-nib structures were fabricated on silicon substrates using the negative photoresist SU-8; they include capillary slots with widths of 8 and 16 microm. A suitable wafer cleaving step made the nib-like structures overhang the edge of a silicon substrate to provide a robust interface for nanoESI-MS applications; this freeing of the nib tip from the wafer surface created a point-like structure that is essential to establish an electrospray. The micro-nib sources were successfully tested on an LCQ Deca XP+ ion trap mass spectrometer using peptide samples at concentrations down to 1 microM. The high voltage was applied using a platinum wire inserted in the sample reservoir upstream to the capillary slot. A Taylor cone was clearly seen at the nib tip. The micro-nibs performed well at voltages as low as 0.8 kV; such performances are state-of-the-art with respect to current micromachined ESI-MS interfaces and are conditions comparable to those used for standard emitter tips. In addition, we clearly observed the influence of the micro-nib slot width on the ionization performances: the narrower the slot, the better the performances.

Gramicidin↗

Two-dimensional microfabricated sources for nanoelectrospray.

The idea of a novel two-dimensional (2D) nanoelectrospray ionization emitter tip with the shape of a nib is explored here. This novel planar design is studied as an alternative to the needle-like standard emitter tips that suffer from a lack of reproducibility and robustness and from an inherent incompatibility with high-throughput analysis. The composition of the micro-nib sources is analogous to the working of a simple fountain pen, with a liquid reservoir linked to a micro-nib tip from which the sample is electrosprayed via a capillary slot. The micro-nib prototypes described here were fabricated using microtechnology techniques and using the epoxy-based negative photoresist SU-8. The resulting free-standing micro-nib structure was supported by a silicon wafer. We present here two series of such micro-nib sources, the latter series exhibiting improved characteristics such as a 8 micro m source width of the nib tip. They were tested in mass spectrometry experiments on an ion trap mass spectrometer (LCQ Deca XP+, Thermo Finnigan) using standard peptide samples having concentrations down to 1 micro M and with a high voltage (HV) supply around 1 kV for the second series of micro-nib sources. In addition to the stability of the spray, the obtained mass spectra showed the reliability of these sources for peptide analysis; the signal of the spectra was as intense and the signal-to-noise ratio (S/N) as high as that obtained with the use of standard emitter tips.

Gramicidin↗