PubMed Health⌕ Search

Biomedical subjects

Steve S Liu

Publications and source records attributed to Steve S Liu.

11 recordsLinked to original sources

Total hip arthroplasty with a cemented, polished, collared femoral stem and a cementless acetabular component. A follow-up study at a minimum of ten years.

BACKGROUND: Recent studies have suggested that cemented femoral components with a polished surface may provide superior long-term fixation when compared with femoral components with a roughened surface. The purpose of this study was to evaluate the results of total hip arthroplasty with a cemented femoral component with a polished surface finish and compare them with the results of total hip arthroplasty performed with a similar design of cemented femoral component with a rougher surface finish. METHODS: We retrospectively reviewed a consecutive group of 132 patients (149 hips) in whom primary total hip arthroplasty had been performed by one surgeon using a cemented collared femoral component with a polished (0.1-microm Ra) surface finish and a cementless acetabular component. Ninety-eight patients (115 hips) were followed for a minimum of ten years. We compared the survivorship of this prosthesis with that of a femoral component of similar design but with rougher surfaces (matte or grit-blasted). RESULTS: No polished stems were revised because of aseptic loosening or demonstrated radiographic evidence of loosening; however, eight hips (5.4%) with a polished stem demonstrated osteolysis distal to the greater or lesser tro-chanter. In contrast, six stems (2.0%) with a matte surface finish of 0.8-microm Ra were revised because of aseptic loosening, and an additional five stems were seen to be loose radiographically. Eleven stems (9.2%) with a grit-blasted surface finish of 2.1-microm Ra were revised because of aseptic loosening, and an additional four stems were seen to be loose radiographically. The difference in the prevalence of revision due to aseptic loosening between the group with the 0.1-microm Ra surface and the group with the 2.1-microm Ra surface was significant (p = 0.001), as was the difference between the prevalence of revision due to aseptic loosening between the group with the 0.8-microm Ra surface and the group with the 2.1-microm Ra surface (p = 0.001). No cups were revised because of aseptic loosening, and one hip had radiographic signs of acetabular loosening. CONCLUSIONS: This study demonstrated excellent durability of a prosthesis consisting of a cemented, collared, polished femoral component and a cementless acetabular component. While no hips were revised because of aseptic loosening, distal femoral osteolysis was observed in eight hips (5.4%), a higher prevalence than has been reported by others after similar durations of follow-up of tapered, collarless, polished femoral components.

Adult↗

Computer-assisted surgery: a wine before its time: in the affirmative.

A number of investigators have demonstrated, in their hands, the potential for computer-assisted navigation to improve precision and accuracy in obtaining optimal knee alignment in the total knee arthroplasty construct. However, it will be difficult to demonstrate improvement in revision and loosening rates. In addition, there are concerns for computer glitches, training of personnel, extra time requirements, and cost and ability to demonstrate improvements in clinical results to warrant these concerns. Reproducibility of these improvements in precision and accuracy in the hands of the less experienced surgeon must be documented.

Arthroplasty, Replacement, Knee↗

Internet promotion of MIS and CAOS in TKA By Knee Society members.

Minimally invasive surgery (MIS) and computer-assisted orthopaedic surgery (CAOS) options for total knee arthroplasty (TKA) have become increasingly popular. However, few controlled studies document their efficacy and safety. We examined the Internet for Knee Society members' websites to evaluate the level of promotion for these procedures in terms of direct (surgeon endorsed) and indirect (surgeon associated) information. On 92 websites, 22.7% made indirect reference to MIS TKA, while only 10.9% made a direct reference. Of the sites referencing MIS TKA, faster recovery was reported on 90% of indirect sites and 50% of direct sites. Specific risks were discussed on only 35% of indirect sites, and on only 20% of direct sites. CAOS TKA was discussed on 6.5% of indirect sites and on 5.4% of direct sites. Although MIS and CAOS TKA are frequently discussed on the Internet, only a small percentage of KS members directly promote these techniques (10.9% and 5.4%, respectively). Information was often indirectly associated with KS surgeons through institutional websites or hospital affiliations. Information indirectly associated with a surgeon may be mistaken as endorsing the procedure by a prospective patient.

Arthroplasty, Replacement, Knee↗

Improved results using extensively coated THA stems at minimum 5-year followup.

The Prodigy femoral component was extensively coated along its entire length, except for a smooth bullet-shaped distal tip. At a minimum 5 year followup we compared the results of that stem to those of a proximally coated first generation femoral component at comparable followup to address the question of which design performed better. For the extensively coated cohort, 86 patients (100 hips) underwent total hip arthroplasty by a single surgeon. At final followup, no patients were lost to followup and no hips were revised for aseptic loosening. Clinically, 3% of patients reported thigh pain (versus 15% in the proximally coated group). Radiographically, all hips had evidence of bone ingrowth (versus 94% in the PCA group). As expected with an extensively coated device there were fewer radiolucencies around the lower half of the prosthesis as well as less distal femoral lysis compared to the proximally coated stem.

Adolescent↗

Results of Charnley total hip arthroplasty with use of improved femoral cementing techniques. a concise follow-up, at a minimum of twenty-five years, of a previous report.

UNLABELLED: The current study was performed to determine the status, at a minimum of twenty-five years, of a prospective, single-surgeon series of patients treated with primary Charnley total hip arthroplasty with a contemporary femoral cementing technique that included use of a distal cement plug and a retrograde cement-delivery system. Since our review at a minimum of twenty years postoperatively, two primary total hip prostheses were revised (one because of acetabular loosening, and one because of femoral loosening). Of the original cohort of 357 hips (320 patients), ten (2.8%) had revision of the femoral stem because of aseptic loosening. Forty-nine patients (fifty-two hips, 14.6%) who had been in the initial study group were still living at the time of the present review. Five hips (10%) in living patients had required a femoral revision because of aseptic loosening. Including those that were revised, eight femoral components (17%) in living patients were seen to be loose radiographically. Although this study demonstrates the remarkable durability of the femoral fixation obtained with the polished flatback Charnley prosthesis and the contemporary cementing technique, there was some deterioration of the results with time. These results provide a standard for comparison with cementless fixation after hips treated with that technique have been followed for a similar duration. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.

Adult↗

The role of implant constraint in revision total knee arthroplasty: not too little, not too much.

The goal of revision total knee arthroplasty is to restore the anatomical alignment of the knee and to provide a stable joint. Joint stability is obtained by balancing the various knee ligaments remaining at the time of revision surgery and by using an implant with added stability if necessary. Understanding the limits of the various designs available (cruciate retaining, cruciate substituting, valgus-varus constraining, and linked) should help the surgeon construct a stable and durable construct.

Arthroplasty, Replacement, Knee↗

Blood management: issues and options.

Blood management in the perioperative period of the total joint arthroplasty procedure has evolved over the last 3 decades. Strategies have changed and are changing based on a better understanding of blood loss and blood replacement options in this patient population. Patient-specific options based on preoperative hemoglobin levels and patient comorbidities as well as anticipated blood loss have been developed and studied. Patient-specific blood management programs have provided cost-efficient care with low morbidity.

Algorithms↗

The John Insall Award: unicompartmental knee replacement: a minimum twenty-one-year followup, end-result study.

UNLABELLED: We report the results of a minimum 21-year followup of a consecutive series of 103 patients who had 136 Marmor cemented unicompartmental knee replacements done between 1975 and 1982. Patients were evaluated clinically and radiographically. At minimum 21-year followup 14 patients (19 knees) were alive, 87 patients (115 knees) had died, and only two patients (two knees) were lost to followup. The average age at surgery was 70.9 years. The average followup Hospital for Special Surgery knee score was 58. The average Knee Society final followup clinical and functional scores averaged 72 and 53 points, respectively. Nineteen knees (14%) were revised during the 21-year followup period: nine for progression of disease, eight for loosening, and two for pain, at an average of 10.6 years (range, 1-22 years). Of the 19 knees in the 14 patients who were still alive at final followup, seven (37%) were revised: two for tibial loosening, four for disease progression, and one for pain. Unicompartmental knee replacements in this relatively older age group of patients performed well at minimum 21-year followup. Although we are encouraged by these results, only 22% were done in patients who were younger than 65 years at the time of surgery and the results in this group were significantly less durable. LEVEL OF EVIDENCE: Therapeutic study, Level IV-1 (case series). See the Guidelines for Authors for a complete description of levels of evidence.

Aged↗

Cemented rotating-platform total knee replacement. a concise follow-up, at a minimum of fifteen years, of a previous report.

We previously evaluated 119 consecutive total knee arthroplasties that were performed in eighty-six patients with use of the cemented LCS (low contact stress) rotating-platform system with an all-polyethylene patellar component. The average age of the patients at the time of surgery was seventy years (range, thirty-seven to eighty-eight years). The purpose of this study was to report the updated results at a minimum follow-up of fifteen years. Thirty-seven patients (fifty-three knees) were living, and no patient was lost to follow-up. No knee was revised because of loosening, osteolysis, or wear. Three knees required a reoperation (two for periprosthetic fractures and one for infection). No component was revised as a part of the reoperations. Osteolysis was present in three knees. No knee had radiographic signs of component loosening, and there were no dislocated bearings. The average range of motion was from 1 degrees of extension to 105 degrees of flexion. The average clinical and functional Knee Society scores were 43 and 49, respectively, at the preoperative evaluation and 85 and 58 at the time of the final follow-up. We concluded that the cemented LCS rotating-platform knee performed well, with durable clinical and radiographic results at a minimum follow-up of fifteen years.

Activities of Daily Living↗

Results of Charnley total hip arthroplasty at a minimum of thirty years. A concise follow-up of a previous report.

The purpose of the current study was to update the results of a prospective, single-surgeon series of primary Charnley total hip arthroplasties performed with cement. This investigation is one of the first studies in which hips treated with total hip arthroplasty with cement were followed for a minimum of thirty years. Twenty-seven patients (thirty-four [10.3%] of the hips in the initial study group) were alive at a minimum of thirty years postoperatively. These patients served as the focus of the present study. Revision because of aseptic loosening of the acetabular component was performed in 7.3% (twenty-three) of the hips from the original study group (excluding those revised because of infection or dislocation) and 26% (eight) of the hips in the living cohort. Revision because of aseptic loosening of the femoral component was performed in 3.2% (ten) of the hips from the original study group (excluding those revised because of infection or dislocation) and 10% (three) of the hips in the living patients. Since the twenty-five-year review, three hips were revised (one because of acetabular loosening, one because of femoral loosening, and one because of instability). This end-result study demonstrated the remarkable durability of cemented Charnley total hip replacements over a span of three decades, with 88% of the original prostheses intact at the time of the final follow-up or at the patient's death.

Aged↗