PubMed Health⌕ Search

Biomedical subjects

Steven G Boxer

Publications and source records attributed to Steven G Boxer.

27 records · Page 2Linked to original sources

Vibrational Stark effects calibrate the sensitivity of vibrational probes for electric fields in proteins.

Infrared spectroscopy is widely used to probe local environments and dynamics in proteins. The introduction of a unique vibration at a specific site of a protein or more complex assembly offers many advantages over observing the spectra of an unmodified protein. We have previously shown that infrared frequency shifts in proteins can arise from differences in the local electric field at the probe vibration. Thus, vibrational frequencies can be used to map electric fields in proteins at many sites or to measure the change in electric field due to a perturbation. The Stark tuning rate gives the sensitivity of a vibrational frequency to an electric field, and for it to be useful, the Stark tuning rate should be as large as possible. Vibrational Stark effect spectroscopy provides a direct measurement of the Stark tuning rate and allows a quantitative interpretation of frequency shifts. We present vibrational Stark spectra of several bond types, extending our work on nitriles and carbonyls and characterizing four additional bond types (carbon-fluorine, carbon-deuterium, azide, and nitro bonds) that are potential probes for electric fields in proteins. The measured Stark tuning rates, peak positions, and extinction coefficients provide the primary information needed to design amino acid analogues or labels to act as probes of local environments in proteins.

2-Naphthylamine↗

Arrays of mobile tethered vesicles on supported lipid bilayers.

We report a new system of laterally mobile, arrayed vesicles that are encoded with DNA to control tethering to fluid-supported phospholipid bilayers. The motion of individual fluorescently labeled vesicles, specifically bound, are easily visualized by fluorescence video microscopy and observed to collide reversibly on the surface. This system is an ideal model for studying interactions involving membranes, in particular integral membrane proteins.

Fluorescent Dyes↗

Polarized absorption spectra of green fluorescent protein single crystals: transition dipole moment directions.

Polarized absorption spectra of orthorhombic crystals of wild-type green fluorescent protein (GFP) were measured between 350 and 520 nm to obtain information on the directions of the electronic transition dipole moments ((-->)m) of the chromophore relative to the molecular axes. The transition dipole moment orientation is a basic spectroscopic parameter of relevance to biologists when interpreting Förster-type fluorescence resonance energy transfer data and for comparing absorbance and fluorescence spectra of GFP with quantum chemical calculations. Maximal extinction was obtained throughout the spectrum when the polarization direction of the electric vector of incident light was parallel to the c-axis of the crystal. The transition dipole moments were assumed to be parallel to the plane of the chromophore. With this assumption and the measured dichroic ratios in the crystals, the transition dipole moments associated with the neutral (lambda(max) = 398 nm) and anionic (lambda(max) = 478 nm) forms of the chromophore were found to subtend angles of approximately 26 degrees and 13 degrees (counterclockwise), respectively, with the vector that joins the phenolic and imidazolinone oxygen atoms of the chromophore.

Amino Acid Substitution↗

Green fluorescent protein variants as ratiometric dual emission pH sensors. 1. Structural characterization and preliminary application.

Novel dual emission, pH-sensitive variants of the green fluorescent protein (GFP) have been constructed and are suitable for ratiometric emission measurements in vivo. This new class of GFPs, termed deGPFs, results from substitution of wild-type residue 65 with threonine and residues 148 and/or 203 with cysteine. deGFPs display pK(a) values ranging from 6.8 to 8.0 and emission that switches from a green form (lambda(max) approximately 515 nm) to a blue form (lambda(max) approximately 460 nm) with acidifying pH. In this report we analyze in most detail the deGFP1 variant (S65T/H148G/T203C, pK(a) approximately 8.0) and the deGFP4 variant (S65T/C48S/H148C/T203C, pK(a) approximately 7.3). In the following paper [McAnaney, T. B., Park, E. S., Hanson, G. T., Remington, S. J., and Boxer, S. G. (2002) Biochemistry 41, 15489-15494], data obtained by ultrafast fluorescence upconversion spectroscopy can be described by a kinetic model that includes an excited-state proton-transfer pathway at high pH but not at low pH. Crystal structure analyses of deGFP1 at high-pH and low-pH conformations were performed to elucidate the basis for the dual emission characteristics. At low pH the structure does not contain a hydrogen bond network that would support rapid transfer of a proton from the excited state of the neutral chromophore to a suitable acceptor; hence blue emission is observed. At high pH, backbone rearrangements induced by changes in the associated hydrogen bond network permit excited-state proton transfer from the excited state of the neutral chromophore to the bulk solvent via Ser147 and bound water molecules, resulting in green emission from the anionic chromophore. Comparative analysis suggests that the basis for dual emission is elimination of the wild-type proton-transfer network by the S65T substitution, a general reduction in hydrogen-bonding opportunities, and a concomitant increase in the hydrophobic nature of the chromophore environment resulting from the cysteine substitutions. We evaluated the suitability of the deGFP4 variant for intracellular pH measurements in mammalian cells by transient expression in PS120 fibroblasts. The responses of deGFP4 and a commercially available pH-sensitive dye, SNARF-1, to changes in pH were compared in the same cells. Results show that the dynamic range of the emission ratio change is comparable between the two pH sensors over the range examined. Two-photon excitation was found to elicit a better deGFP4 fluorescent signal above cellular autofluorescence when compared to conventional confocal microscopy. Given their favorable optical characteristics, suitable pK(a)'s for the physiological pH range, and suitability for ratiometric measurements, dual emission GFPs should make excellent probes for studying pH in vivo.

Amino Acid Substitution↗

Green fluorescent protein variants as ratiometric dual emission pH sensors. 2. Excited-state dynamics.

In the preceding paper [Hanson, G. T., McAnaney, T. B., Park, E. S., Rendell, M. E. P., Yarbrough, D. K., Chu, S., Xi, L., Boxer, S. G., Montrose, M. H., and Remington, S. J. (2002) Biochemistry 41, 15477-15488], novel mutants of the green fluorescent protein (GFP) that exhibit dual steady-state emission properties were characterized structurally and discussed as potential intracellular pH probes. In this work, the excited-state dynamics of one of these new dual emission GFP variants, deGFP4 (C48S/S65T/H148C/T203C), is studied by ultrafast fluorescence upconversion spectroscopy. Following excitation of the high-energy absorption band centered at 398 nm and assigned to the neutral form of the chromophore, time-resolved emission was monitored from the excited state of both the neutral and intermediate anionic chromophores at both high and low pH and upon deuteration of exchangeable protons. The time-resolved emission dynamics and isotope effect appear to be very different from those of wild-type GFP [Chattoraj, M., King, B. A., Bublitz, G. U., and Boxer, S. G. (1996) Proc. Natl. Acad. Sci. U.S.A. 93, 8362-8367]; however, due to overlapping emission bands, the apparent difference can be analyzed quantitatively within the same framework used to describe GFP excited-state dynamics. The results indicate that the pH-sensitive steady-state emission characteristics of deGFP4 are a result of a pH-dependent modulation of the rate of excited-state proton transfer. At high pH, a rapid interconversion from the excited state of the higher energy neutral chromophore to the lower energy intermediate anionic chromophore is achieved by proton transfer. At low pH, excited-state proton transfer is slowed to the point where it is no longer rate limiting.

Animals↗

Probing protein electrostatics with a synthetic fluorescent amino acid.

Electrostatics affect virtually all aspects of protein structure and activity and are particularly important in proteins whose primary function is to stabilize charge. Here we introduce a fluorescent amino acid, Aladan, which can probe the electrostatic character of a protein at multiple sites. Aladan is exceptionally sensitive to the polarity of its surroundings and can be incorporated site-selectively at buried and exposed sites, in both soluble and membrane proteins. Steady-state and time-resolved fluorescence measurements of Aladan residues at different buried and exposed sites in the B1 domain of protein G suggest that its interior is polar and heterogeneous.

2-Naphthylamine↗

Early steps of supported bilayer formation probed by single vesicle fluorescence assays.

We have developed a single vesicle assay to study the mechanisms of supported bilayer formation. Fluorescently labeled, unilamellar vesicles (30-100 nm diameter) were first adsorbed to a quartz surface at low enough surface concentrations to visualize single vesicles. Fusion and rupture events during the bilayer formation, induced by the subsequent addition of unlabeled vesicles, were detected by measuring two-color fluorescence signals simultaneously. Lipid-conjugated dyes monitored the membrane fusion while encapsulated dyes reported on the vesicle rupture. Four dominant pathways were observed, each exhibiting characteristic two-color fluorescence signatures: 1) primary fusion, in which an unlabeled vesicle fuses with a labeled vesicle on the surface, is signified by the dequenching of the lipid-conjugated dyes followed by rupture and final merging into the bilayer; 2) simultaneous fusion and rupture, in which a labeled vesicle on the surface ruptures simultaneously upon fusion with an unlabeled vesicle; 3) no dequenching, in which loss of fluorescence signal from both dyes occur simultaneously with the final merger into the bilayer; and 4) isolated rupture (pre-ruptured vesicles), in which a labeled vesicle on the surface spontaneously undergoes content loss, a process that occurs with high efficiency in the presence of a high concentration of Texas Red-labeled lipids. Vesicles that have undergone content loss appear to be more fusogenic than intact vesicles.

Adsorption↗

Micropattern formation in supported lipid membranes.

Phospholipid vesicles exhibit a natural tendency to fuse and assemble into a continuous single bilayer membrane on silica and several other substrate materials. The resulting supported membrane maintains many of the physical and biological characteristics of free membranes, including lateral fluidity. Recent advances, building on the supported membrane configuration, have created a wealth of opportunities for the manipulation, control, and analysis of membranes and the reaction environments they provide. The work reviewed in this Account, which can be broadly characterized as the science and technology of membrane patterning, contains three basic components: lateral diffusion control (barriers), membrane deposition techniques (microarrays), and electric field-induced lateral reorganization. Collectively, these preparative and analytical patterned membrane techniques offer a broad experimental platform for the study and utilization of lipid membranes.

Diffusion↗

Proximal ligand motions in H93G myoglobin.

Resonance Raman spectroscopy has been used to observe changes in the iron-ligand stretching frequency in photoproduct spectra of the proximal cavity mutant of myoglobin H93G. The measurements compare the deoxy ferrous state of the heme iron in H93G(L), where L is an exogenous imidazole ligand bound in the proximal cavity, to the photolyzed intermediate of H93G(L)*CO at 8 ns. There are significant differences in the frequencies of the iron-ligand axial out-of-plane mode nu(Fe-L) in the photoproduct spectra depending on the nature of L for a series of methyl-substituted imidazoles. Further comparison was made with the proximal cavity mutant of myoglobin in the absence of exogenous ligand (H93G) and the photoproduct of the carbonmonoxy adduct of H93G (H93G-*CO). For this case, it has been shown that H2O is the axial (fifth) ligand to the heme iron in the deoxy form of H93G. The photoproduct of H93G-*CO is consistent with a transiently bound ligand proposed to be a histidine. The data presented here further substantiate the conclusion that a conformationally driven ligand switch exists in photolyzed H93G-*CO. The results suggest that ligand conformational changes in response to dynamic motions of the globin on the nanosecond and longer time scales are a general feature of the H93G proximal cavity mutant.

Animals↗