PubMed Health⌕ Search

Biomedical subjects

Steven J Hoff

Publications and source records attributed to Steven J Hoff.

7 recordsLinked to original sources

Emissions of ammonia, hydrogen sulfide, and odor before, during, and after slurry removal from a deep-pit swine finisher.

It is a common practice in the midwestern United States to raise swine in buildings with under-floor slurry storage systems designed to store manure for up to one year. These so-called "deep-pit" systems are a concentrated source for the emissions of ammonia (NH3), hydrogen sulfide (H2S), and odors. As part of a larger six-state research effort (U.S. Department of Agriculture-Initiative for Future Agriculture and Food Systems Project, "Aerial Pollutant Emissions from Confined Animal Buildings"), realtime NH3 and H2S with incremental odor emission data were collected for two annual slurry removal events. For this study, two 1000-head deep-pit swine finishing facilities in central Iowa were monitored with one-year storage of slurry maintained in a 2.4 m-deep concrete pit (or holding tank) below the animal-occupied zone. Results show that the H2S emission, measured during four independent slurry removal events over two years, increased by an average of 61.9 times relative to the before-removal H2S emission levels. This increase persisted during the agitation process of the slurry that on average occurred over an 8-hr time period. At the conclusion of slurry agitation, the H2S emission decreased by an average of 10.4 times the before-removal emission level. NH3 emission during agitation increased by an average of 4.6 times the before-removal emission level and increased by an average of 1.5 times the before-removal emission level after slurry removal was completed. Odor emission increased by a factor of 3.4 times the before-removal odor emission level and decreased after the slurry-removal event by a factor of 5.6 times the before-removal emission level. The results indicate that maintaining an adequate barn ventilation rate regardless of animal comfort demand is essential to keeping gas levels inside the barn below hazardous levels.

Air Pollution, Indoor↗

Quality-assured measurements of animal building emissions: particulate matter concentrations.

Federally funded, multistate field studies were initiated in 2002 to measure emissions of particulate matter (PM) < 10 microm (PM10) and total suspended particulate (TSP), ammonia, hydrogen sulfide, carbon dioxide, methane, nonmethane hydrocarbons, and odor from swine and poultry production buildings in the United States. This paper describes the use of a continuous PM analyzer based on the tapered element oscillating microbalance (TEOM). In these studies, the TEOM was used to measure PM emissions at identical locations in paired barns. Measuring PM concentrations in swine and poultry barns, compared with measuring PM in ambient air, required more frequent maintenance of the TEOM. External screens were used to prevent rapid plugging of the insect screen in the PM10 preseparator inlet. Minute means of mass concentrations exhibited a sinusoidal pattern that followed the variation of relative humidity, indicating that mass concentration measurements were affected by water vapor condensation onto and evaporation of moisture from the TEOM filter. Filter loading increased the humidity effect, most likely because of increased water vapor adsorption capacity of added PM. In a single layer barn study, collocated TEOMs, equipped with TSP and PM10 inlets, corresponded well when placed near the inlets of exhaust fans in a layer barn. Initial data showed that average daily mean concentrations of TSP, PM10, and PM2.5 concentrations at a layer barn were 1440 +/- 182 microg/m3 (n = 2), 553 +/- 79 microg/m3 (n = 4), and 33 +/- 75 microg/m3 (n = 1), respectively. The daily mean TSP concentration (n = 1) of a swine barn sprinkled with soybean oil was 67% lower than an untreated swine barn, which had a daily mean TSP concentration of 1143 +/- 619 microg/m3. The daily mean ambient TSP concentration (n = 1) near the swine barns was 25 +/- 8 microg/m3. Concentrations of PM inside the swine barns were correlated to pig activity.

Air Pollutants↗

Quality assured measurements of animal building emissions: gas concentrations.

Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 microm in diameter, and total suspended particulate from swine and poultry production buildings in the United States. This paper focuses on the quasicontinuous gas concentration measurement at multiple locations among paired barns in seven states. Documented principles, used in air pollution monitoring at industrial sources, were applied in developing quality assurance (QA) project plans for these studies. Air was sampled from multiple locations with each gas analyzed with one high quality commercial gas analyzer that was located in an environmentally controlled on-farm instrument shelter. A nominal 4 L/min gas sampling system was designed and constructed with Teflon wetted surfaces, bypass pumping, and sample line flow and pressure sensors. Three-way solenoids were used to automatically switch between multiple gas sampling lines with > or =10 min sampling intervals. Inside and outside gas sampling probes were between 10 and 115 m away from the analyzers. Analyzers used chemiluminescence, fluorescence, photoacoustic infrared, and photoionization detectors for NH3, H2S, CO2, CH4, and NMHC, respectively. Data were collected using personal computer-based data acquisition hardware and software. This paper discusses the methodology of gas concentration measurements and the unique challenges that livestock barns pose for achieving desired accuracy and precision, data representativeness, comparability and completeness, and instrument calibration and maintenance.

Air Pollutants↗

Solid-phase microextraction as a novel air sampling technology for improved, GC-olfactometry-based assessment of livestock odors.

Air sampling and characterization of odorous livestock gases is one of the most challenging analytical tasks. This is because of low concentrations, physicochemical properties, and problems with sample recoveries for typical odorants. Livestock operations emit a very complex mixture of volatile organic compounds (VOCs) and other gases. Many of these gases are odorous. Relatively little is known about the link between characteristic VOCs/gases and, specifically, about the impact of characteristic odorants downwind from sources. In this research, solid-phase microextraction (SPME) is used for field air sampling of odors downwind from swine and beef cattle operations. Sampling time ranges from 20 min to 1 h. Samples are analyzed using a commercial gas chromatography-mass spectrometry-olfactometry system. Odor profiling efforts are directed at odorant prioritization, with respect to distance from the source. The results indicate the odor downwind is increasingly defined by a smaller number of high-priority odorants. These "character defining" odorants appear to be dominated by compounds of relatively low volatility, high molecular weight, and high polarity. In particular, p-cresol alone appears to carry much of the overall odor impact for swine and beef cattle operations. Of particular interest is the character-defining odor impact of p-cresol as far as 16 km downwind of the nearest beef cattle feedlot. The findings are highly relevant to scientists and engineers working on improved air sampling and analysis protocols and on improved technologies for odor abatement. More research evaluating the use of p-cresol and a few other key odorants as a surrogate for overall odor dispersion modeling is warranted.

Animals↗

Characterization of volatile organic compounds and odorants associated with swine barn particulate matter using solid-phase microextraction and gas chromatography-mass spectrometry-olfactometry.

Swine operations can affect air quality by emissions of odor, volatile organic compounds (VOCs) and other gases, and particulate matter (PM). Particulate matter has been proposed to be an important pathway for carrying odor. However, little is known about the odor-VOCs-PM interactions. In this research, continuous PM sampling was conducted simultaneously with three collocated TEOM 1400a analyzers inside a 1000-head swine finish barn located in central Iowa. Each TEOM was fitted with total suspended particulate (TSP), PM-10, PM-2.5 and PM-1 preseparators. Used filters were stored in 40 mL vials and transported to the laboratory. VOCs adsorbed/absorbed to dust were allowed to equilibrate with vial headspace. Solid-phase microextraction (SPME) Carboxen/polydimethylsiloxane (PDMS) 85 microm fibers were used to extract VOCs. Simultaneous chemical and olfactometry analyses of VOCs and odor associated with swine PM were completed using a gas chromatography-mass spectrometry-olfactometry (GC-MS-O) system. Fifty VOCs categorized into nine chemical function groups were identified and confirmed with standards. Five of them are classified as hazardous air pollutants. VOCs were characterized with a wide range of molecular weight, boiling points, vapor pressures, water solubilities, odor detection thresholds, and atmospheric reactivities. All characteristic swine VOCs and odorants were present in PM and their abundance was proportional to PM size. However, the majority of VOCs and characteristic swine odorants were preferentially bound to smaller-size PM. The findings indicate that a significant fraction of swine odor can be carried by PM. Research of the effects of PM control on swine odor mitigation is warranted.

Animals↗

Prevalence and clinical course of pleural effusions at 30 days after coronary artery and cardiac surgery.

The present prospective study was designed to determine the prevalence of pleural effusion at approximately 28 days after cardiac surgery and their subsequent course. This consecutive case study included 389 patients; 312 had only coronary artery bypass graft surgery (CABG) surgery, 37 had both valve and CABG surgery, and 40 had only valve surgery. Chest radiographs were obtained approximately 28 days postoperatively. Patients were subsequently contacted by telephone 3, 6, and 12 months postoperatively and questioned about the presence of fluid in their chest and related symptoms. The prevalence of pleural effusions in the patients undergoing only CABG surgery (63%) or CABG surgery plus valve surgery (62%) was significantly (p = 0.05) higher than that in the patients undergoing valve surgery only (45%). The prevalence of effusions occupying more than 25% of the hemithorax was 9.7%. The primary symptom associated with these larger effusions was dyspnea. Chest pain and fever were uncommon. Over the 12-month follow-up, the effusions tended to resolve. In conclusion, the prevalence of pleural effusions occupying more than 25% of the hemithorax is approximately 10%, 28 days postoperatively. These larger pleural effusions produce dyspnea but not chest pain or fever, and most of the effusions disappear gradually over the subsequent months.

Coronary Artery Bypass↗

Coronary artery bypass in patients 80 years and over: is off-pump the operation of choice?

BACKGROUND: Octogenarians are at increased risk for perioperative morbidity and mortality after coronary artery bypass. In this study we compared our experience with patients undergoing on-pump coronary artery bypass (CAB) and those undergoing off-pump coronary artery bypass (OPCAB) to assess outcomes. METHODS: We used hospital database analysis in patients 80 years and older who underwent nonemergent coronary artery bypass with (N = 169) and without (N = 60) cardiopulmonary bypass from January 1999 through June 2001. RESULTS: Both groups were at increased perioperative risk based on the Society of Thoracic Surgeons risk model (7.7% OPCAB vs 5.8% CAB, p = 0.03). There were no operative deaths in the OPCAB group but there were eight (4.7%) in the CAB group (p = NS). Perioperative stroke (0% OPCAB vs 7.1% CAB, p = 0.04), prolonged ventilation (1.7% OPCAB vs 11.8% CAB, p = 0.02), and transfusion rate (33% OPCAB vs 70.4% CAB, p < 0.001) were all lower in the OPCAB group. A shorter hospital stay (6.3 days OPCAB vs 11.5 days CAB, p < 0.001) resulted in lower hospital cost in the OPCAB group ($9,363 OPCAB vs $12,312 CAB, p < 0.001). CONCLUSIONS: In this study, off-pump coronary artery bypass grafting in elderly patients was associated with fewer complications, a shorter hospital stay, and lower hospital cost. Off-pump coronary artery bypass grafting may be the operation of choice for octogenarians requiring surgical myocardial revascularization.

Aged↗